1、 International Code Council500 New Jersey Avenue, NW, 6thFloorWashington, D.C. 20001Approved October 7, 2014American National Standards Institute1899 L Street, NW, 11thFloorWashington, D.C. 20036ICC 500-2014ICC/NSSA Standard for the Design and Construction of Storm SheltersAmerican National Standard

2、14-10014_NSSA-ICC_500-2014_StormShelter_Stndrd_TP_Final.indd 1 10/29/2014 12:03:50 PMICC/NSSA Standard for the Design and Construction of Storm Shelters2014(ICC 5002014)First Printing: December 2014ISBN: 978-1-60983-402-9Copyright 2014byINTERNATIONAL CODE COUNCIL, INC.ALL RIGHTS RESERVED. This ICC/N

3、SSA Standard for the Design and Construction of Storm Shelters2014 (ICC 500) is acopyrighted work owned by the International Code Council, Inc. Without advance written permission from the copyright owner,no part of this book may be reproduced, distributed, or transmitted in any form or by any means,

4、 including, without limitation,electronic, optical or mechanical means (by way of example, and not limitation, photocopying, or recording by or in an informa-tion storage retrieval system). For information on permission to copy material exceeding fair use, please contact: Publications,4051 Flossmoor

5、 Road, Country Club Hills, IL 60478. Phone 1-888-ICC-SAFE (422-7233).Trademarks: “ICC,” the “International Code Council” logo and “Standard for the Design and Construction of Storm Shelters(ICC 5002014)” are trademarks of the International Code Council, Inc. The “NSSA” logo is a trademark of the Nat

6、ionalStorm Shelter Association.PRINTED IN THE U.S.A.STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS2014 iiiAmericanNationalStandardApproval of an American National Standard requires verification by ANSI that the requirements for due process, consensus andother criteria for approval have b

7、een met by the standards developer.Consensus is established when in the judgment of the ANSI Board of Standards Review, substantial agreement has been reachedby directly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarilyunanimity. Con

8、sensus requires that all views and objections be considered, and that a concerted effort be made toward their res-olution.The use of American National Standards is completely voluntary; their existence does not in any respect preclude anyone,whether he or she has approved the standards or not, from

9、manufacturing, marketing, purchasing or using products, processes orprocedures not conforming to the standards.The American National Standards Institute does not develop standards and will in no circumstances give an interpretation of anyAmerican National Standard. Moreover, no person shall have the

10、 right or authority to issue an interpretation of an AmericanNational Standard in the name of the American National Standards Institute. Requests for interpretations should be addressed tothe secretariat or sponsor whose name appears on the title page of this standard.CAUTION NOTICE: This American N

11、ational Standard may be revised or withdrawn at any time. The procedures of the Ameri-can National Standards Institute require that action be taken periodically to reaffirm, revise or withdraw this standard. Purchasersof American National Standards may receive current information on all standards by

12、 calling or writing the American NationalStandards Institute. iv STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS2014 STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS2014 vICC/NSSAStandard for the Design and Construction of Storm SheltersFOREWORDThe information contained in this

13、foreword is not part of this American National Standard (ANS) and has not been processed inaccordance with ANSIs requirements for an ANS. As such, this foreword may contain material that has not been subjected topublic review or a consensus process. In addition, it does not contain requirements nece

14、ssary for conformance to this standard.IntroductionIn May of 2002 the International Code Council (ICC) and the National Storm Shelter Association (NSSA) initiated a joint proj-ect to write a standard for the design and construction of storm shelters. A standard development committee was created, and

15、 thefirst meeting of that committee was in May of 2003. The scope of the standard is to provide minimum design and constructionrequirements for storm shelters that provide a safe refuge from storms that produce high winds, hurricanes and tornadoes. Hurri-canes and tornadoes generate high winds that

16、produce wind pressures on buildings and structures and that create flying debris atlevels and intensities than are higher than those for which most commercial building and residences are designed. The magni-tude of the wind speeds associated with these storms are such that building occupants and res

17、idents are required to evacuate thearea or seek protection in a shelter designed for resistance to extraordinary loads and flying debris. This standard provides designrequirements for the main wind-resisting structural system and components and cladding of these shelters, and provides basicoccupant

18、life safety and health requirements for these shelters, including means of egress, lighting, sanitation, ventilation, firesafety and minimum required floor space for occupants.DevelopmentThis is the second edition of the International Code Council (ICC) and National Storm Shelter Associations (NSSA)

19、 Standardfor the Design and Construction of Storm Shelters. This standard was developed by the ICC/NSSA Consensus Committee onStorm Shelters (IS-STM) that operates under ANSI Approved ICC Consensus Procedures for the Development of ICC Stan-dards. The consensus process of ICC for promulgating standa

20、rds is accredited by ANSI. The Storm Shelter Committee is a bal-anced committee formed and operated in accordance with ICC rules and procedures.The meetings of the ICC/NSSA IS-STM Consensus Committee were open to the public and interested individuals and organiza-tions from across the country partic

21、ipated. The technical content of currently published documents on storm shelters, includingdocuments of the National Storm Shelter Association, the Federal Emergency Management Agency (FEMA), the Red Cross,and the State of Florida, was reviewed and considered by the committee. The information from t

22、hese documents helped form abasis for the regulations installed in this standard, but the exact provisions adopted by the committee were determined basedupon the scope and intent of this standard. The requirements of ICC/NSSA 500 are based on the intent to establish provisionsconsistent with the sco

23、pe of the ICC family of codes and standards that are written to adequately protect public health, safety andwelfare; provisions that do not necessarily increase construction costs; provisions that do not restrict the use of new materials,products or methods of construction; and provisions that do no

24、t give preferential treatment to particular types or classes of mate-rials, products or methods of construction.AdoptionICC/NSSA 500 Standard for the Design and Construction of Storm Shelters is available for adoption and use by any jurisdic-tion. Its use within a governmental jurisdiction is intend

25、ed to be accomplished through adoption by reference in accordance withproceedings establishing the jurisdictions laws. At the time of adoption, jurisdictions should insert the appropriate informationin provisions requiring specific local information, such as the name of the jurisdiction.vi STANDARD

26、FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS2014InterpretationsRequests for Interpretations on the provisions of ICC 5002014 should be addressed to: ICC, Central Regional Office, 4051Flossmoor Road, Country Club Hills, IL 60478.Maintenance Submittal of ProposalsAll ICC standards are periodicall

27、y updated as required by ANSI. Proposals for revising this edition are welcome. Please visit theICC website at www.iccsafe.org for the official “Call for Proposals” announcement. A proposal form and instructions can alsobe downloaded from www.iccsafe.org.ICC, its members and those participating in t

28、he development of ICC 5002014 do not accept any liability resulting from com-pliance or noncompliance with the provisions of ICC 5002014. ICC does not have the power or authority to police or enforcecompliance with the contents of this standard. Only the governmental body that enacts this standard i

29、nto law has such authority.International Code Council/National Storm Shelter Association Consensus Committee onStorm Shelters (IS-STM)Consensus Committee SCOPE: The ICC/NSSA Consensus Committee on Storm Shelters (IS-STM) shall have primaryresponsibility for minimum requirements to safeguard the publ

30、ic health, safety and general welfare through design, constructionand installation requirements for storm shelters.This standard was processed and approved for submittal to ANSI by the ICC/NSSA Consensus Committee on Storm Shelters(IS-STM). Committee approval of the standard does not necessarily imp

31、ly that all committee members voted for its approval.Representatives on the Consensus Committee are classified in one of three voting interest categories. The committee has beenformed in order to achieve consensus as required by ANSI Essential Requirements. At the time it approved this standard, the

32、 IS-STM Consensus Committee consisted of the following members:General Interest (G) - User Interest (U) - Producer Interest (P)Mr. Julian Amaya (G), Housing Department City of Los Angeles, South Gate, CAMr. Brian Bishop (G), Iowa Department of Public SafetyState Fire Marshals Office, Des Moines, IAM

33、r. Gary J. Ehrlich, P.E. (P), National Association of Home Builders, Washington, DCMr. Carlos M. Flores, AIA, NCARB, CGC (P), CMF International Group Inc., Miami, FL Ms. Cheri Bright Hainer, CBO (G), City of Virginia Beach/Planning/Permits including a drawing or image indicating theentire facility.1

34、2. A storm shelter section or elevation indicating theheight of the storm shelter relative to the finishedgrade, finished floor and the host building, whereapplicable.13. The lowest shelter floor elevation and correspond-ing datum, except for residential shelters outside ofspecial flood hazard areas

35、.APPLICATION AND ADMINISTRATIONSTANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS2014 314. The occupant load of the storm shelter.15. The usable storm shelter floor area.16. Venting area (square inches) provided and locationsin the shelter.17. Calculations for the number of sanitation facili

36、tiesfor community shelters.18. Minimum foundation capacity requirements.19. Shelter installation requirements, including anchorlocation and minimum required capacity for eachanchor.20. For hurricane shelters, the rainfall rate of the roofprimary drainage system.21. For hurricane shelters, the rainfa

37、ll rate of the roofsecondary (overflow) drainage system whererequired.22. For hurricane shelters, the rainwater drainagedesign rainfall rate for facilities subject to rainwaterimpoundment. 107.2.2 Enclosure. When a storm shelter is to be con-structed as a portion of a host building, the walls andflo

38、ors enclosing the shelter shall be clearly indicated onthe drawings.107.2.3 Signage. The type and location of signs requiredby this standard shall be indicated on the floor plans.107.2.4 Inspections. Where any special details are utilizedin the design of the structure, or where any special investi-g

39、ations are required in addition to those required by theapplicable building code, the construction documents shallcontain a schedule of the inspections required and the cri-teria for the special installation.107.2.5 Special details. The construction documents shallprovide or include any special manu

40、facturers details orinstallation instructions for systems or equipment designedfor the storm shelter.107.2.6 Special instructions. The construction documentsshall provide or include any special details or specialinstructions required for the functional operation of thestorm shelter, such as:1. Type

41、and location of equipment and amenitiesrequired within the shelter, including water supply,sanitary facilities, fire extinguishers, batteries,flashlights, special emergency lighting equipmentor any other equipment required to be installed inthe shelter.2. Specifications for any alarm system to be in

42、stalled.3. Instructions for the installation or deployment ofany special protection equipment such as shutters,screens, special latching of doors or windows, anyequipment or switching for mechanical, electricaland plumbing equipment.107.3 Quality assurance plan. The construction documentsfor communi

43、ty shelters shall contain a quality assurance planin accordance with Sections 107.3.1 through 107.3.3.107.3.1 Detailed requirements. A quality assurance planshall be provided for the following:1. Roof cladding, soffits and roof framing connec-tions.2. Wall connections to roof and floor diaphragms an

44、dframing.3. Roof and floor diaphragm systems, including con-nectors, drag struts and boundary elements.4. Main windforce-resisting systems, including bracedframes, moment frames and shear walls.5. Main windforce-resisting system connections to thefoundation. 6. Fabrication and installation of compon

45、ents andassemblies of the shelter envelope required to meetmissile impact test requirements of Chapter 3.7. Wall cladding and wall cladding connections. 8. Corrosion resistance or protection of exposed metalconnectors providing load path continuity.9. Critical support systems and connections and deb

46、risimpact protection of the components and connec-tions.10. Foundation design.11. Prefabricated shelter installation requirements,including anchor location and minimum requiredcapacity for each type of anchor.12. Prefabricated shelter minimum foundation capacityrequirements.107.3.2 Quality assurance

47、 plan preparation. A qualityassurance plan prepared by a registered design profes-sional shall be provided for each main windforce-resistingsystem and each wind-resisting component.The quality assurance plan shall identify the following:1. The main windforce-resisting systems and wind-resisting comp

48、onents.2. The special inspections and testing to be required inaccordance with Section 106.2.3. The type and frequency of testing required.4. The type and frequency of special inspectionsrequired.5. The structural observations to be performed inaccordance with Section 106.4.6. The required distribut

49、ion, type and frequency ofreports of test, inspections and structural observa-tions.107.3.3 Contractor responsibility. Each contractorresponsible for the construction, fabrication or installationof a main windforce-resisting system or any componentAPPLICATION AND ADMINISTRATION4 STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS2014listed in the quality assurance plan shall submit a writtenstatement of r

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1