ANSI IEEE C37.90-2005 Relays and Relay Systems Associated with Electric Power Apparatus.pdf

上传人:testyield361 文档编号:435313 上传时间:2018-11-14 格式:PDF 页数:29 大小:154.23KB
下载 相关 举报
ANSI IEEE C37.90-2005 Relays and Relay Systems Associated with Electric Power Apparatus.pdf_第1页
第1页 / 共29页
ANSI IEEE C37.90-2005 Relays and Relay Systems Associated with Electric Power Apparatus.pdf_第2页
第2页 / 共29页
ANSI IEEE C37.90-2005 Relays and Relay Systems Associated with Electric Power Apparatus.pdf_第3页
第3页 / 共29页
ANSI IEEE C37.90-2005 Relays and Relay Systems Associated with Electric Power Apparatus.pdf_第4页
第4页 / 共29页
ANSI IEEE C37.90-2005 Relays and Relay Systems Associated with Electric Power Apparatus.pdf_第5页
第5页 / 共29页
亲,该文档总共29页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、IEEE Std C37.90-2005(Revision ofIEEE Std C37.90-1989)IEEE Standard for Relays andRelay Systems Associated withElectric Power ApparatusI E E E3 Park Avenue New York, NY 10016-5997, USA31 January 2006IEEE Power Engineering SocietySponsored by thePower System Relaying CommitteeCopyright 2001 IEEE. All

2、rights reserved. 1IEEE Std C37.90-2005(R2011)(Revision of IEEE Std C37.90-1989)IEEE Standard for Relays andRelay Systems Associated withElectric Power ApparatusSponsorPower System Relaying Committeeof the IEEE Power Engineering SocietyApproved 22 September 2005Reaffirmed 31 March 2011IEEE-SA Standar

3、ds BoardApproved 23 May 2012 American National Standards InstituteThe Institute of Electrical and Electronics Engineers, Inc.3 Park Avenue, New York, NY 10016-5997, USACopyright 2006 by the Institute of Electrical and Electronics Engineers, Inc.All rights reserved. Published 31 January 2006. Printed

4、 in the United States of America.IEEE is a registered trademark in the U.S. Patent (978) 750-8400. Permission to photocopy portions of any individual standard for educationalclassroom use can also be obtained through the Copyright Clearance Center.Note: Attention is called to the possibility that im

5、plementation of this standard may require use of subject mat-ter covered by patent rights. By publication of this standard, no position is taken with respect to the existence orvalidity of any patent rights in connection therewith. The IEEE shall not be responsible for identifying patentsfor which a

6、 license may be required by an IEEE standard or for conducting inquiries into the legal validity orscope of those patents that are brought to its attention.ivCopyright 2006 IEEE. All rights reserved.IntroductionThis revision of IEEE Std C37.90 contains significant changes in content and organization

7、 so it willharmonize more closely with currently published IEC standards whenever possible. The standard has alsobeen updated to include many changes to provide for a more effective document that is now representativeof currently manufactured relay products used in the industry. The changes are as d

8、escribed in the followinglist. a) Clause 2, Normative references, has been added where required. b) Clause 3, Definitions, has been revised to provide for alphabetical classification by function. c) Clause 4, Service conditions, has been revised to provide categories for specific temperature rangesa

9、nd differentiation of ambient and extreme temperature ranges. Relative humidity now specifiesrelay or relay systems. Other conditions have been changed to show numeric designations. d) Clause 5, Electrical ratings, specifies additional standard current and voltage ratings and notes,applicable to Tab

10、le 3. Table 4 specifies additional maximum design voltages for dc control. Table 7and Table 8 specify coil resistance/burden at ambient temperature 25 C. A subclause has beenadded to address latching current requirements. e) Clause 6, Heating limits of temperature rise for coils, has been revised to

11、 add information on howthe temperature rise of the coils is to be determined. f) Clause 7, Mechanical requirements, has been added to provide information on the mechanicaldurability of relays, plug-in feature requirements, and relay setting controls to harmonize withcurrent IEC requirements. g) Clau

12、se 8, Insulation tests, was changed from Dielectric tests and now includes the requirement foran impulse voltage test as a design test. Table 9 and Figure 1 have been added to this clause. h) An annex of International Electrotechnical Commission (IEC) standards, relevant to IEEE Std C37.90,has been

13、added to provide additional information for clarification and harmonization with IECstandards. In preparing this standard, consideration has been given to the work of other committees,and especially to international standards that have been published or that are under preparation byTechnical Committ

14、ee 95 of IEC. Notice to usersErrataErrata, if any, for this and all other standards can be accessed at the following URL: http:/standards.ieee.org/reading/ieee/updates/errata/index.html. Users are encouraged to check this URL forerrata periodically.InterpretationsCurrent interpretations can be acces

15、sed at the following URL: http:/standards.ieee.org/reading/ieee/interp/index.html.This introduction is not part of IEEE Std C37.90-2005, IEEE Standard for Relays and Relay Systems Associatedwith Electric Power Apparatus.vCopyright 2006 IEEE. All rights reserved.PatentsAttention is called to the poss

16、ibility that implementation of this standard may require use of subject mattercovered by patent rights. By publication of this standard, no position is taken with respect to the existence orvalidity of any patent rights in connection therewith. The IEEE shall not be responsible for identifying paten

17、tsor patent applications for which a license may be required to implement an IEEE standard or for conductinginquiries into the legal validity or scope of those patents that are brought to its attention.ParticipantsAt the time this standard was completed, the C37.90 Working Group had the following me

18、mbership:Mario Ranieri, ChairJames Teague, Vice-ChairThe following members of the individual balloting committee voted on this standard. Balloters may have voted for approval, disapproval, or abstention. Robert W. BeckwithThomas R. BeckwithJeffrey BurnworthJohn W. Chadwick, Jr.Clifford L. DownsJohn

19、J. HorwathJames D. Huddleston, IIIGerald F. JohnsonPeter A. KotosMichael J. McDonaldRobert PettigrewWilliam M. StrangRobert J. SullivanJohn TengdinDavid ViersHanna Abdallah William AckermanSteve AlexandersonRichard F. AngleStan J. ArnotMunnu BajpaiGeorge BartokRobert W. BeckwithRobert BereshMichael

20、BioStuart BoucheyGustavo BrunelloJeffrey BurnworthMark CarpenterCarlos CastroJohn W. Chadwick, Jr.Tommy CooperRatan DasRonald DaubertByron DavenportClifford L. DownsPaul DrumWalter ElmoreAmir El-SheikhJames EvansKenneth FoderoMarcel FortinTrilok GargFrank GerleveJeffrey G. GilbertMietek GlinkowskiRu

21、ss GonnamRobert GoodinStephen GrierErik GuillotRoger HeddingJerry HohnEdward Horgan Jr.John J. HorwathJames D. Huddleston, III Chris HuntleyDavid Jackson George KalacherryHermann KochJoseph L KoepfingerPeter A. KotosTerry KrummreyLuther KurtzMarc LacroixCarl LaPlaceStephen R. LambertRoger LawrenceJa

22、son LinAlbert LivshitzWilliam LoweGregory LuriWilliam MajeskiThomas McCaffreyJohn McDonaldMichael J. McDonaldMark McGranaghanMichael MeisingerA. MeliopoulosGary MichelDean MillerCharles MozinaBruce MuschlitzAnthony NapikoskiT. W. OlsenRussell PattersonCarlos PeixotoKostas PervolarakisRobert Pettigre

23、wPaul PillitteriMario RanieriRoger RayCharles RogersJames RuggieriMohindar S. SachdevMiriam SandersDavid SchemppThomas SchossigTony SeegersTarlochan SidhuH. Jin SimMark SimonVeselin SkendzicJames SmithJames StonerWilliam M. StrangCharles SufanaRobert J. SullivanMalcolm SwansonRichard TaylorJames Tea

24、gueJohn TengdinShanmugan ThamilarasanDemetrios TziouvarasEric UdrenCharles WagnerRonald Westfall Kenneth WhiteMurty YallaDonald W. ZipseviCopyright 2006 IEEE. All rights reserved.When the IEEE-SA Standards Board approved this guide on 22 September 2005, it had the followingmembership:Steve M. Mills,

25、 ChairRichard H. Hulett, Vice ChairDon Wright, Past ChairJudith Gorman, Secretary*Member EmeritusAlso included are the following nonvoting IEEE-SA Standards Board liaisons:Satish K. Aggarwal, NRC RepresentativeRichard DeBlasio, DOE RepresentativeAlan H. Cookson, NIST RepresentativeJennie SteinhagenI

26、EEE Standards Project EditorMark D. BowmanDennis B. BrophyJoseph BruderRichard CoxBob DavisJulian Forster*Joanna N. GueninMark S. HalpinRaymond HapemanWilliam B. HopfLowell G. JohnsonHerman KochJoseph L. Koepfinger*David J. LawDaleep C. MohlaPaul NikolichT. W. OlsenGlenn ParsonsRonald C. PetersenGar

27、y S. RobinsonFrank StoneMalcolm V. ThadenRichard L. TownsendJoe D. WatsonHoward L. WolfmanContents 1. Overview 1 1.1 Scope . 1 1.2 Purpose 2 2. Normative references 2 3. Special terms 2 4. Service conditions 2 4.1 Usual service conditions 2 4.2 Unusual service conditions 4 5. Electrical ratings. 5 5

28、.1 Standard current and voltage ratings for relays . 5 5.2 Maximum design voltage and current for relays . 6 5.3 Allowable variations from rated voltage for voltage operated auxiliary relays. 6 5.4 Allowable variation from rated voltage and current for protective relays . 7 5.5 Allowable ac componen

29、t in dc control voltage supply 8 5.6 Short time thermal withstand. 8 5.7 Make, carry, and interrupt ratings for tripping output circuits.9 5.8 Make, carry, and interrupt ratings for output circuits not rated for tripping 10 5.9 Published data for auxiliary relays. 10 6. Heating limits of temperature

30、 rise for coils 12 7. Mechanical requirements 12 7.1 Mechanical durability of relay operation. 12 7.2 Mechanical durability of plug-in relays. 12 7.3 Mechanical durability of relay setting controls . 12 7.4 Shock and vibration. 13 8. Insulation tests 13 8.1 General requirements. 13 8.2 Dielectric po

31、wer frequency tests 13 8.3 Impulse voltage tests . 15 Annex A (informative) Applicable IEC standards . 17 vii Copyright 2006 IEEE. All rights reserved. IEEE Standard for Relays and Relay Systems Associated with Electric Power Apparatus 1. 1.1Overview This standard specifies standard service conditio

32、ns, standard ratings, performance requirements, and testing requirements for relays and relay systems used to protect and control power apparatus. The standard establishes a common reproducible basis for designing and evaluating relay and relay systems. Annex A provides a cross-reference to the appl

33、icable IEC standards. Certain specific tests required for relays and relay systems are covered in separate IEEE standards as noted below. Required surge tests are documented in IEEE Std C37.90.1-20021. Standardized test waveforms that are representative of surges observed and measured in actual inst

34、allations are applied to the terminals of the system. The relay or relay system must be able to withstand the applied surges without damage to components and without operating incorrectly. Required susceptibility tests are documented in IEEE Std C37.90.2-1995. The tests establish a method to evaluat

35、e the susceptibility of the relay under test to single frequency electromagnetic fields in the radio frequency domain, such as those generated by portable or mobile radio transceivers. Required electrostatic discharge tests are documented in IEEE Std C37.90.3-2001. Generators which that produce a st

36、andard waveform are used to apply discharges to conductive and non-conductive points on equipment under test. The test is performed to confirm that relays and relay systems will not misoperate or be damaged when installed, energized, and/or subjected to a specified electrostatic discharge. Scope Thi

37、s standard specifies standard service conditions, standard ratings, performance requirements, and testing requirements for relays and relay systems used to protect and control power apparatus. A relay system may include computer interface equipment and/or communications interface equipment, such as

38、a carrier transmitter/receiver or audio tone equipment. It does not cover relays designed primarily for industrial control, for switching communication or other low-level signals, or any other equipment not intended for control of power apparatus. 1Information about the documents referenced in this

39、clause can be found in Annex A. 1 Copyright 2006 IEEE. All rights reserved. IEEE Std C37.90-2005 IEEE Standard for Relays and Relay Systems Associated with Electric Power Apparatus 1.22. 3.a) b) c) d) e) f) 4.4.1Purpose The purpose of this standard is to establish a common reproducible basis for des

40、igning and evaluating relays and relay systems. Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any a

41、mendments or corrigenda) applies. IEEE Std C37.100, IEEE Standard Definitions for Power Switchgear.2,3Special terms A relay is an electric device designed to respond to input conditions in a prescribed manner and, after specified conditions are met, to cause contact operation or similar abrupt chang

42、e in associated electric control circuits. A relay may consist of several relay units, each responsive to a specified input, with the combination of units providing the desired overall performance characteristic of the relay. Inputs are usually electrical but may be mechanical, thermal, other quanti

43、ties, or a combination of quantities. Limit switches and similar simple devices are not relays. Relay terminology covers a wide area from the detailed relay structural principles through complex power system relay applications. The following basic areas of power system relay applications provide a c

44、onvenient method of classification by function: Protective Monitoring Regulating Auxiliary Reclosing Sync check Definitions of other relay terms are not included in this standard. Refer to IEEE Std C37.1004. Service conditions Usual service conditions Relays and relay systems conforming to this stan

45、dard shall be suitable for operation under the conditions described in 4.1.1, 4.1.2, 4.1.3, and 4.1.4. 2The IEEE standards or products referred to in this standard are trademarks of the Institute of Electrical and Electronics Engineers, Inc. 3IEEE publications are available from the Institute of Ele

46、ctrical and Electronics Engineers, Inc., 445 Hoes Lane, Piscataway, NJ 08854, USA (http:/standards.ieee.org/). 4Information on references can be found in Clause 2. 2 Copyright 2006 IEEE. All rights reserved. IEEE Std C37.90-2005 IEEE Standard for Relays and Relay Systems Associated with Electric Pow

47、er Apparatus 4.1.1a) b) c) d) 4.1.2a) b) c) d) 4.1.34.1.4Operational temperature range This is the temperature of the still air (i.e., no forced-air movement) measured 30 cm from the front surface of the unit (relay or relay system) enclosure and cover. The manufacturer shall declare the operational

48、 range of ambient temperature for which the relay or relay system is rated. The temperature range shall be selected from the following: 40 C to +70 C 30 C to +65 C 20 C to +55 C Range defined by manufacturer, but must encompass 20 C to +55 C The characteristics of the relay shall not vary more than

49、the published tolerances for temperatures in the selected range. The manufacturer shall declare the effects of temperature on component parts of the relay or relay system that may result in a visual change but not the operational accuracy of the functions included within the package (i.e., an LCD display may become dark, or unreadable due to the ambient temperature; however, this condition does not affect the proper operation of the included protection or other packaged functions.) The manufacturer shall declare whether operation at

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
  • BS PD CLC TR 50479-2007 Electrical installation guide — Selection and erection of electrical nequipment — Wiring systems — Limitation of temperature rise of nconnecting in.pdf BS PD CLC TR 50479-2007 Electrical installation guide — Selection and erection of electrical nequipment — Wiring systems — Limitation of temperature rise of nconnecting in.pdf
  • BS PD CLC TR 50481-2009 Recommendations on filters nfor shielded enclosures《屏蔽室用过滤器的建议》.pdf BS PD CLC TR 50481-2009 Recommendations on filters nfor shielded enclosures《屏蔽室用过滤器的建议》.pdf
  • BS PD CLC TR 50484-2009 2500 Recommendations for nshielded enclosures《屏蔽室操作建议》.pdf BS PD CLC TR 50484-2009 2500 Recommendations for nshielded enclosures《屏蔽室操作建议》.pdf
  • BS PD CLC TR 50485-2010 Electromagnetic compatibility — nEmission measurements in fully nanechoic chambers《电磁兼容性 全电波暗室发射测定》.pdf BS PD CLC TR 50485-2010 Electromagnetic compatibility — nEmission measurements in fully nanechoic chambers《电磁兼容性 全电波暗室发射测定》.pdf
  • BS PD CLC TR 50501-1-2007 Railway applications — Rolling stock — Intercommunication nbetween vehicles and train wayside — Part 1 Data dictionary and rules for functional .pdf BS PD CLC TR 50501-1-2007 Railway applications — Rolling stock — Intercommunication nbetween vehicles and train wayside — Part 1 Data dictionary and rules for functional .pdf
  • BS PD CLC TR 50506-1-2007 Railway applications — Communication signalling and processing systems — Application Guide for EN 50129 — Part 1 Cross-acceptance《轨道交通 通信 信号和处理系.pdf BS PD CLC TR 50506-1-2007 Railway applications — Communication signalling and processing systems — Application Guide for EN 50129 — Part 1 Cross-acceptance《轨道交通 通信 信号和处理系.pdf
  • BS PD CLC TR 50506-2-2009 3750 Railway applications — nCommunication signalling and nprocessing systems — Application nguide for EN 50129《轨道交通 通信 信号和处理系统 EN 50129使用指南》.pdf BS PD CLC TR 50506-2-2009 3750 Railway applications — nCommunication signalling and nprocessing systems — Application nguide for EN 50129《轨道交通 通信 信号和处理系统 EN 50129使用指南》.pdf
  • BS PD CLC TR 50507-2007 Railway applications — nInterference limits of nexisting track circuits nused on European nrailways《轨道交通 用于欧洲铁路的现有轨道电路的干扰极限》.pdf BS PD CLC TR 50507-2007 Railway applications — nInterference limits of nexisting track circuits nused on European nrailways《轨道交通 用于欧洲铁路的现有轨道电路的干扰极限》.pdf
  • BS PD CLC TR 50511-2007 Railway applications — nCommunications nsignalling and nprocessing systems — nERTMS ETCS — nExternal signalling for nlines equipped with nERTMS ET.pdf BS PD CLC TR 50511-2007 Railway applications — nCommunications nsignalling and nprocessing systems — nERTMS ETCS — nExternal signalling for nlines equipped with nERTMS ET.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1