1、 INCITS/ISO/IEC 19785-2:2006/Amd1: 2010 2010 ISO/IEC 19785-2:2006/Amd1:2010 Information technology Common Biometric Exchange Formats Framework Part 2: Procedures for the operation of the Biometric Registration Authority AMD 1: Additional registrations Reaffirmed as INCITS/ISO/IEC 19785-2:2006/AM 1:2
2、010 R2015INCITS/ISO/IEC 19785-2:2006/Amd1:2010 2010 PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the compute
3、r performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create
4、this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Ce
5、ntral Secretariat at the address given below. Adopted by INCITS (InterNational Committee for Information Technology Standards) as an American National Standard. Date of ANSI Approval: 9/29/2010 Published by American National Standards Institute, 25 West 43rd Street, New York, New York 10036 Copyrigh
6、t 2010 by Information Technology Industry Council (ITI). All rights reserved. These materials are subject to copyright claims of International Standardization Organization (ISO), International Electrotechnical Commission (IEC), American National Standards Institute (ANSI), and Information Technology
7、 Industry Council (ITI). Not for resale. No part of this publication may be reproduced in any form, including an electronic retrieval system, without the prior written permission of ITI. All requests pertaining to this standard should be submitted to ITI, 1250 Eye Street NW, Washington, DC 20005. Pr
8、inted in the United States of America ii ITIC 2010 All rights reserved ISO/IEC 19785-2:2006/Amd.1:2010(E) ISO/IEC 2010 All rights reserved iiiForeword ISO (the International Organization for Standardization) and IEC (the International Electrotechnical Commission) form the specialized system for worl
9、dwide standardization. National bodies that are members of ISO or IEC participate in the development of International Standards through technical committees established by the respective organization to deal with particular fields of technical activity. ISO and IEC technical committees collaborate i
10、n fields of mutual interest. Other international organizations, governmental and non-governmental, in liaison with ISO and IEC, also take part in the work. In the field of information technology, ISO and IEC have established a joint technical committee, ISO/IEC JTC 1. International Standards are dra
11、fted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of the joint technical committee is to prepare International Standards. Draft International Standards adopted by the joint technical committee are circulated to national bodies for voting. Publication as an Inte
12、rnational Standard requires approval by at least 75 % of the national bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO and IEC shall not be held responsible for identifying any or all such patent rights.
13、Amendment 1 to ISO/IEC 19785-2:2006 was prepared by Joint Technical Committee ISO/IEC JTC 1, Information technology, Subcommittee SC 37, Biometrics. ISO/IEC 19785-2:2006/Amd.1:2010(E) ISO/IEC 2010 All rights reserved 1Information technology Common Biometric Exchange Formats Framework Part 2: Procedu
14、res for the operation of the Biometric Registration Authority AMENDMENT 1: Additional registrations Page iv, Foreword, in the list of parts replace: The following part is under preparation: Part 3: Patron Format Specifications with: Part 3: Patron format specifications Part 4: Security Block Specifi
15、cations Page v, Introduction Replace the first two paragraphs with the following: Biometric-based authentication systems and applications are expected to support multiple biometric devices, multiple biometric data formats, and multiple algorithms for feature extraction, comparison, quality determina
16、tion and compression, possibly each from a different vendor. The Common Biometric Exchange Formats Framework (CBEFF) promotes interoperability of biometric-based application programs and systems developed by different vendors by facilitating biometric data interchange. This part of ISO/IEC 19785 sup
17、ports such exchanges by providing unambiguous identification of biometric organizations, formats and products, with separate registration of identifiers for components of products that are capture devices, feature extraction algorithms, comparison algorithms, quality algorithms and compression algor
18、ithms. This part of ISO/IEC 19785 specifies procedures for a Registration Authority that is responsible for the assignment of ASN.1 object identifier components to identify biometric organizations, CBEFF patrons, biometric information record formats, biometric data block formats, security block form
19、ats, biometric products capture devices, feature extraction algorithms, comparison algorithms, quality algorithms and compression algorithms to provide globally unambiguous identification in the context of the CBEFF ASN.1 object identifier. Page 1, Scope Replace the text with the following (where ch
20、anges to existing text are highlighted with a grey background): This part of ISO/IEC 19785 specifies the procedures to be followed by the Biometric Registration Authority in preparing, maintaining, and publishing registers of identifiers for biometric organizations, CBEFF patron formats, BDB formats
21、, security block formats, biometric products, and specialized biometric products. ISO/IEC 19785-2:2006/Amd.1:2010(E) 2 ISO/IEC 2010 All rights reservedPage 1, 3.1 Delete the following terms from the list: biometric sample; CBEFF biometric organization identifier; CBEFF patron; CBEFF patron format; s
22、ecurity block format identifier. and add the following terms: capture device; capture device identifier; comparison algorithm; comparison algorithm identifier; feature extraction algorithm; feature extraction algorithm identifier; quality algorithm; quality algorithm identifier. Page 2, 3.2 Replace
23、the introductory sentence with the following: For the purposes of this document, in addition to those terms given in 3.1 the following terms and definitions apply. Page 2, after 3.2.5 Insert the following: 3.2.6 specialized biometric product biometric product which is in one of the categories: captu
24、re device, feature extraction algorithm, comparison algorithm, quality algorithm, or compression algorithm (see the definitions of these terms) NOTE A specialized biometric product can be registered both as a specialized biometric product of the appropriate category and also as a (general) biometric
25、 product. ISO/IEC 19785-2:2006/Amd.1:2010(E) ISO/IEC 2010 All rights reserved 3Page 2, 5.1 e) Replace the list item with the following: e) Biometric products (including specialized biometric products) supported by an organization that is a registered biometric organization. Page 3, 5.5 Delete the la
26、st sentence of the second paragraph: “Arcs identified by CBEFF biometric organization identifiers do not have arc names.” Page 4, 5.7 Change the second part of the paragraph (following the arc name) to read as follows (where changes to existing text are highlighted with a grey background): and enabl
27、es publication of a reference to the specification of that BIR format (CBEFF patron format). The is either the decimal value of the sixteen-bit CBEFF patron identifier of the definer of the CBEFF patron format, or is an arc identifier followed by the decimal value in parentheses. The allocated objec
28、t identifier value is worldwide unambiguous, but the BIR format identifier can also be used alone in contexts where the preceding arcs are implied. Page 4, 5.8 Change the second part of the paragraph (following the arc name) to read as follows (where changes to existing text are highlighted with a g
29、rey background): and enables publication of a reference to the specification of that BDB format. The is either the decimal value of the sixteen-bit CBEFF biometric organization identifier of the definer of the BDB format, or is an arc identifier followed by the decimal value in parentheses. The allo
30、cated object identifier value is worldwide unambiguous, but the BDB format value can also be used alone in contexts where the preceding arcs are implied. Page 4, 5.10 Change the second part of the paragraph (following the arc name) to read as follows (where changes to existing text are highlighted w
31、ith a grey background): The is either the sixteen-bit CBEFF biometric organization identifier of the owner of the biometric product, or is an arc identifier followed by the decimal value in parentheses. The allocated object identifier value is worldwide unambiguous, but the biometric product identif
32、ier can also be used alone in contexts where the preceding arcs are implied. ISO/IEC 19785-2:2006/Amd.1:2010(E) 4 ISO/IEC 2010 All rights reservedPage 4, after 5.10 Insert the following new subclause and renumber 5.11, 5.12, 5.13 and 5.14 as 5.12, 5.13, 5.14 and 5.15 respectively: 5.11 Successful re
33、gistration of a specialized biometric product by a CBEFF biometric organization records that the specialized biometric product is identified (within its category) by an arc with a CBEFF biometric product identifier allocated by the Registration Authority. This is a sixteen-bit binary value (that can
34、 be interpreted as a positive integer) for an ASN.1 object identifier arc under one of the arcs: iso registration-authority cbeff(19785) organizations(0) capture-device(4) iso registration-authority cbeff(19785) organizations(0) feature-extraction-algorithm(5) iso registration-authority cbeff(19785)
35、 organizations(0) comparison-algorithm(6) iso registration-authority cbeff(19785) organizations(0) quality-algorithm(7) iso registration-authority cbeff(19785) organizations(0) compression-algorithm(8) according to the category of the specialized product. The is either the sixteen-bit CBEFF biometri
36、c organization identifier of the owner of the biometric product, or is an arc identifier followed by the decimal value in parentheses. The allocated object identifier value is worldwide unambiguous, but the biometric product identifier can also be used alone in contexts where the category of the spe
37、cialized product (and earlier arcs) is implied. Page 7, Clause 9 Replace the clause title with the following (where changes to existing text are highlighted with a grey background): 9 Registration procedures for BIR formats, BDB formats, SB formats, biometric products and specialized biometric produ
38、cts and replace the content of 9.1.1 and 9.1.2 with the following: 9.1.1 This clause specifies the procedures to be followed in the registration of BIR formats (CBEFF patron formats), BDB formats, SB formats, biometric products and specialized biometric products. The procedures are designed to provi
39、de simple registration, with minimal administrative overhead. 9.1.2 The biometric product identifier for a biometric product or specialized biometric product is typically combined with the CBEFF biometric organization identifier that has been assigned to the owner of the biometric product. The biome
40、tric product identifier or specialized biometric product identifier is uniquely assigned by a biometric organization within the context of its biometric organization identifier (and category of specialized biometric product) and can be optionally registered and published by the RA. Registration is o
41、ptonal, but is strongly recommended for specialized biometric products, as the identification of these secialized biometric products is carried in fields of many BDB formats, and provides information that can assist in the later processing of the BDB. ISO/IEC 19785-2:2006/Amd.1:2010(E) ISO/IEC 2010
42、All rights reserved 5NOTE Implementations of these values are encoded as determined by the CBEFF patron (the body specifying a BIR format). There are no restrictions on data encoding. The representation and assignment as 4 hexadecimal digits is not intended to specify an encoding method. and replace
43、 the title of 9.2 with the following (where changes to existing text are highlighted with a grey background): 9.2 Application for registration of a BIR format, BDB format, SB format, biometric product, or specialized biometric product Page 8, 10.3 Replace the subclause title with the following (wher
44、e changes to existing text are highlighted with a grey background): 10.3 Application for registration of a BIR format, BDB format, SB format, biometric product or specialized biometric product Page 9, 10.3 b) Insert the following new list item: 5) The category of the specialized biometric product an
45、d its identifier (unique within its category) to be registered and a document in an RA-approved document format specifying the details of the specialized biometric product for which registration is requested. Page 9, 11.1 Replace the entire subclause with the following (where changes to existing tex
46、t are highlighted with a grey background): The RA shall maintain ten registers to include the following: a) biometric organizations, indicating whether they are accepted as CBEFF patrons or not; b) registered CBEFF patron formats; c) registered BDB formats; d) registered SB formats; e) registered pr
47、oducts; f) a separate register for each of the five categories of specialized biometric product. Each entry shall give the identifier information, together with a link to the full details provided in the approved application. Page 9, 11.2 In the first sentence, insert the word “ten” before the word
48、“registers”. ISO/IEC 19785-2:2006/Amd.1:2010(E) 6 ISO/IEC 2010 All rights reservedPage 9, 11.3 Replace the entire subclause with the following (where changes to existing text are highlighted with a grey background): 11.3 The registers shall contain full details of approved applications, together wit
49、h a copy of any information that is referenced by a non-permanent reference, such as a URL, of any RA allocations made to the applicant, and of any subsequent identifiers allocated and registered by a registered biometric organization. The registers shall be capable of interrogation using the value of the RA allocation that has been made, or by a combination of an RA allocation of a biometric organizati