ANSI INCITS ISO IEC 29109-9-2011 Information technology - Conformance testing methodology for biometric data interchange formats defined in ISO IEC 19794 - Part 9 Vascular image da.pdf

上传人:lawfemale396 文档编号:436428 上传时间:2018-11-14 格式:PDF 页数:14 大小:125.57KB
下载 相关 举报
ANSI INCITS ISO IEC 29109-9-2011 Information technology - Conformance testing methodology for biometric data interchange formats defined in ISO IEC 19794 - Part 9 Vascular image da.pdf_第1页
第1页 / 共14页
ANSI INCITS ISO IEC 29109-9-2011 Information technology - Conformance testing methodology for biometric data interchange formats defined in ISO IEC 19794 - Part 9 Vascular image da.pdf_第2页
第2页 / 共14页
ANSI INCITS ISO IEC 29109-9-2011 Information technology - Conformance testing methodology for biometric data interchange formats defined in ISO IEC 19794 - Part 9 Vascular image da.pdf_第3页
第3页 / 共14页
ANSI INCITS ISO IEC 29109-9-2011 Information technology - Conformance testing methodology for biometric data interchange formats defined in ISO IEC 19794 - Part 9 Vascular image da.pdf_第4页
第4页 / 共14页
ANSI INCITS ISO IEC 29109-9-2011 Information technology - Conformance testing methodology for biometric data interchange formats defined in ISO IEC 19794 - Part 9 Vascular image da.pdf_第5页
第5页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、 INCITS/ISO/IEC 29109-9:2011 2013 ISO/IEC 29109-9:2011 Information technology Conformance testing methodology for biometric data interchange formats defined in ISO/IEC 19794 Part 9: Vascular image data INCITS/ISO/IEC 29109-9:2011 2013 PDF disclaimer This PDF file may contain embedded typefaces. In a

2、ccordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobe

3、s licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for p

4、rinting. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. Adopted by INCITS (InterNational Committee for Information Technology S

5、tandards) as an American National Standard. Date of ANSI Approval: 2/25/2013 Published by American National Standards Institute, 25 West 43rd Street, New York, New York 10036 Copyright 2013 by Information Technology Industry Council (ITI). All rights reserved. These materials are subject to copyrigh

6、t claims of International Standardization Organization (ISO), International Electrotechnical Commission (IEC), American National Standards Institute (ANSI), and Information Technology Industry Council (ITI). Not for resale. No part of this publication may be reproduced in any form, including an elec

7、tronic retrieval system, without the prior written permission of ITI. All requests pertaining to this standard should be submitted to ITI, 1250 Eye Street NW, Washington, DC 20005. Printed in the United States of America ii ITIC 2013 All rights reserved ISO/IEC 29109-9:2011(E) ISO/IEC 2011 All right

8、s reserved iiiForeword ISO (the International Organization for Standardization) and IEC (the International Electrotechnical Commission) form the specialized system for worldwide standardization. National bodies that are members of ISO or IEC participate in the development of International Standards

9、through technical committees established by the respective organization to deal with particular fields of technical activity. ISO and IEC technical committees collaborate in fields of mutual interest. Other international organizations, governmental and non-governmental, in liaison with ISO and IEC,

10、also take part in the work. In the field of information technology, ISO and IEC have established a joint technical committee, ISO/IEC JTC 1. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of the joint technical committee is to

11、prepare International Standards. Draft International Standards adopted by the joint technical committee are circulated to national bodies for voting. Publication as an International Standard requires approval by at least 75 % of the national bodies casting a vote. Attention is drawn to the possibili

12、ty that some of the elements of this document may be the subject of patent rights. ISO and IEC shall not be held responsible for identifying any or all such patent rights. ISO/IEC 29109-9 was prepared by Joint Technical Committee ISO/IEC JTC 1, Information technology, Subcommittee SC 37, Biometrics.

13、 ISO/IEC 29109 consists of the following parts, under the general title Information technology Conformance testing methodology for biometric data interchange formats defined in ISO/IEC 19794: Part 1: Generalized conformance testing methodology Part 2: Finger minutiae data Part 4: Finger image data P

14、art 5: Face image data Part 6: Iris image data Part 7: Signature/sign time series data Part 8: Finger pattern skeletal data Part 9: Vascular image data Part 10: Hand geometry silhouette data The following parts are under preparation: Part 14: DNA data Finger pattern spectral data, signature/sign pro

15、cessed dynamic data and voice data will form the subjects of future parts. ISO/IEC 29109-9:2011(E) iv ISO/IEC 2011 All rights reservedIntroduction ISO/IEC 19794-9:2007 specifies a data record interchange format for exchange of human vascular image data among systems within a Common Biometric Exchang

16、e Formats Framework (CBEFF) data structure. The data stored in a vascular data record often contains the metadata storing the subject-specific and image-specific, as well as the technology being used. This part of ISO/IEC 29109 establishes tests for checking the correctness of the binary record. Whe

17、n vascular image data is transmitted among systems, it can be interfered with by noise due to the transmission line. The received data might be incorrect during the exchange process. Therefore, there is a need to conduct conformance tests of commercial products to determine whether the data conform

18、to ISO/IEC 19794-9:2007 before using the data for other purposes. Vascular biometric technology is emerging or is under development by many research organizations. The vascular image resources are also being used by many vendors, who have utilized the vascular technology as a recognition or verifica

19、tion method in their systems. Currently, however, there is no standardized method for conducting conformance tests of vascular image data that supports ISO/IEC 19794-9:2007 during the exchange of vascular image data among systems. Application developers and implementers of different organizations ca

20、n interpret ISO/IEC 19794-9:2007 in different manners. Therefore, a standardized conformance testing methodology is necessary for achieving interoperability among implementations. This part of ISO/IEC 29109 supports those applications that require use of vascular image data according to ISO/IEC 1979

21、4-9:2007. It defines a testing methodology to ensure conformance of a vendors application or service to ISO/IEC 19794-9:2007. Thus, it is intended to: establish elements of the conformance testing methodology framework that are specific to the vascular image-based data record requirements of ISO/IEC

22、 19794-9:2007 conformance testing; define requirements and guidelines for specifying conformance test suites and related test methods for measuring conformity of products and services to the vascular image data record requirements of ISO/IEC 19794-9:2007; and define testing and reporting procedures

23、to be followed before, during, and after conformance testing. This part of ISO/IEC 29109 is applicable to the development and use of conformity test method specifications, conformity test suites for ISO/IEC 19794-9:2007 records, and conformance testing programs for ISO/IEC 19794-9:2007 conformant pr

24、oducts. It is intended primarily for use by testing organizations, but can be applied by developers and users of test method specifications and test method implementations. INTERNATIONAL STANDARD ISO/IEC 29109-9:2011(E) ISO/IEC 2011 All rights reserved 1Information technology Conformance testing met

25、hodology for biometric data interchange formats defined in ISO/IEC 19794 Part 9: Vascular image data 1 Scope This part of ISO/IEC 29109 specifies elements of conformance testing methodology, test assertions, and test procedures as applicable to ISO/IEC 19794-9. It specifies test assertions of the st

26、ructure of the vascular image data format as specified in ISO/IEC 19794-9:2007 (Type A Level 1 as defined in ISO/IEC 29109-1), test assertions of internal consistency by checking the types of values that can be contained within each field (Type A Level 2 as defined in ISO/IEC 29109-1). It does not s

27、pecify a test of conformance of CBEFF structures required by ISO/IEC 19794-9:2007, a test of consistency with an input biometric data record (Level 3), a test of other characteristics of biometric products or other types of testing of biometric products (e.g. acceptance, performance, robustness, sec

28、urity), a test of conformance of systems that do not produce ISO/IEC 19794-9:2007 records. 2 Conformance Biometric data interchange format conformance tests conform to this part of ISO/IEC 29109 if they satisfy all of the normative requirements related to Clause 6. Specifically, they shall use the t

29、est methodology specified in Clauses 6, 7 and 8 of ISO/IEC 29109-1:2009, and all Level 1 and Level 2 tests shall use the assertions defined in Table 2 in this part of ISO/IEC 29109. Implementations of ISO/IEC 19794-9:2007 tested according to the specified methodology shall be able to claim conforman

30、ce only to those Biometric Data Record (BDR) requirements specified in ISO/IEC 19794-9:2007 that are tested by the test methods established by this methodology. Implementations of ISO/IEC 19794-9:2007 do not necessarily need to conform to all possible aspects of ISO/IEC 19794-9:2007, but only to tho

31、se ISO/IEC 19794-9:2007 requirements that are claimed to be supported by the implementation in an Implementation Conformance Statement (ICS), filled out in accordance with Clause 8 of ISO/IEC 29109-1:2009 and Table 1 in this part of ISO/IEC 29109. NOTE Level 3 and higher are not tested. ISO/IEC 2910

32、9-9:2011(E) 2 ISO/IEC 2011 All rights reserved3 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any a

33、mendments) applies. ISO/IEC 19794-9:2007, Information technology Biometric data interchange formats Part 9: Vascular image data ISO/IEC 29109-1:2009, Information technology Conformance testing methodology for biometric data interchange formats defined in ISO/IEC 19794 Part 1: Generalized conformance

34、 testing methodology 4 Terms and definitions For the purposes of this document, the terms and definitions given in ISO/IEC 29109-1 apply. 5 Symbols and abbreviated terms For the purposes of this document, the symbols and abbreviations given in ISO/IEC 29109-1 apply. 6 Conformance testing methodology

35、 6.1 General The testing methodology specified in Clauses 6, 7 and 8 of ISO/IEC 29109-1:2009 applies. The content of the tables below is based on the conformance testing methodology outlined in ISO/IEC 29109-1 and shall only be used in the context of that testing methodology. 6.2 Table of requiremen

36、ts in the base standard The normative requirements of ISO/IEC 19794-9:2007 are listed in Table 1. The supplier of the implementation under test (IUT) can explain which optional components of ISO/IEC 19794-9:2007 are supported and the testing laboratory can note the results of the test. ISO/IEC 29109

37、-9:2011(E) ISO/IEC 2011 All rights reserved 3Table 1 Requirements of the base standard (ISO/IEC 19794-9:2007) Requirement ID Reference in Base Standard Requirement Summary Level Status IUT Support Supported Range Test Result R-1 6.1 The quantities in all records and vascular biometric image elements

38、 (pixel data), if represented as multibyte quantities, are represented in big-endian format. 1 M N/A R-2 6.1 The order for transmission shall also be the most significant byte first and the least significant byte last. Within a byte, the order of transmission shall be the most significant bit first

39、and the least significant bit last. 3C O-1 N/A N/T R-3 6.2 The scan sequence shall be raster scan order. 3C O-1 N/A N/T R-4 7.1 The spatial resolution of the captured image shall be represented in terms of pixels per centimetre. 3C O-1 N/A N/T R-5 7.2 The image shall have a dynamic range spanning at

40、 least 128 gray scale levels, allocating at least one byte (8 bits) per intensity value and providing at least 7 bits of useful intensity information. 1 M N/A R-6 7.5 The captured image shall be an orthographic projection of the body area being imaged. 3C O-1 N/A N/T R-7 7.6.2 If lossless compressio

41、n is used the image data shall be compressed in accordance with the JPEG-LS lossless compression algorithm specified in ISO/IEC 14495 or the JPEG2000 compression algorithm specified in ISO/IEC 15444. 3C O-1 N/A N/T R-8 7.6.3 If lossy compression is used the image shall be compressed in accordance wi

42、th the JPEG compression algorithm specified in ISO/IEC 10918 or the JPEG2000 compression algorithm specified in ISO/IEC 15444. 3C O-1 N/A N/T R-9 7.6.4 Images captured with more than three sensing channels shall be stored in accordance with the JPEG2000 compression algorithm as specified in ISO/IEC

43、15444. 3C O-1 N/A N/T R-10 7.7 The location of human body used for imaging shall be specified in the format. 1 M N/A R-11 7.7 The direction (left/right) of hand and/or finger index (thumb, index, middle, ring, and little) shall be specified. 1 M N/A R-12 8.2.1 The format identifier for the vascular

44、biometric image standard record shall consist of the three ASCII characters “VIR“ followed by a null character (0x00). 1 M N/A R-13 8.2.2 The number for the version of this standard used for constructing the image record shall be placed in four bytes. This version number shall consist of three ASCII

45、 numerals followed by a zero byte as a NULL string terminator. The first and second characters will represent the major version number, while the third character will represent the minor revision number. The current version number shall be 010 indicating the version 1 with no revision. 1 M N/A R-14

46、8.2.3 The combined length in bytes for the entire record shall be recorded in these four bytes. 1 M R-15 8.2.3 This count shall be total length of record block including record header and image headers. 2 M R-16 8.2.4 The capture device ID shall be recorded in two bytes. A value of all zeros shall b

47、e acceptable and will indicate that the device ID is unreported. The vendor determines the value for this field. Application developers may obtain the values for these codes from the respective vendors. 1 M ISO/IEC 29109-9:2011(E) 4 ISO/IEC 2011 All rights reservedR-17 8.2.5 The number of vascular i

48、mages included in the data block shall be recorded in two bytes. 2 M R-18 8.2.5 It is required that all images in a single vascular image data block be from the same imaging device. If two images are captured by two different devices with different capture device IDs, they shall be stored in separat

49、e data blocks, not in the same block. 3C O-1 N/A N/T R-19 8.3.2 This four-byte field shall specify the total length of the image block including the image header and data. 1 M R-20 8.3.2 This four-byte field shall specify the total length of the image block including the image header and data. 2 M R-21 8.3.3 These two fields specify the horizontal and vertical image size in pixels, in two bytes

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1