ANSI ISA 75.08.08-2015 Face-to-Centerline Dimensions for Flanged Globe-Style Angle Control Valve Bodies (Classes 150 300 and 600).pdf

上传人:bowdiet140 文档编号:436966 上传时间:2018-11-14 格式:PDF 页数:14 大小:334.23KB
下载 相关 举报
ANSI ISA 75.08.08-2015 Face-to-Centerline Dimensions for Flanged Globe-Style Angle Control Valve Bodies (Classes 150 300 and 600).pdf_第1页
第1页 / 共14页
ANSI ISA 75.08.08-2015 Face-to-Centerline Dimensions for Flanged Globe-Style Angle Control Valve Bodies (Classes 150 300 and 600).pdf_第2页
第2页 / 共14页
ANSI ISA 75.08.08-2015 Face-to-Centerline Dimensions for Flanged Globe-Style Angle Control Valve Bodies (Classes 150 300 and 600).pdf_第3页
第3页 / 共14页
ANSI ISA 75.08.08-2015 Face-to-Centerline Dimensions for Flanged Globe-Style Angle Control Valve Bodies (Classes 150 300 and 600).pdf_第4页
第4页 / 共14页
ANSI ISA 75.08.08-2015 Face-to-Centerline Dimensions for Flanged Globe-Style Angle Control Valve Bodies (Classes 150 300 and 600).pdf_第5页
第5页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、 AMERICAN NATIONALSTANDARD ANSI/ISA-75.08.08-2015 Formerly ANSI/ISA-75.22-1999 Face-to-Centerline Dimensions for Flanged Globe-Style Angle Control Valve Bodies (Classes 150, 300, and 600) Approved 30 December 2015 ANSI/ISA-75.08.08-2015 Face-to-Centerline Dimensions for Flanged Globe-Style Angle Con

2、trol Valve Bodies (Classes 150, 300, and 600) ISBN: 978-1-941546-85-7 Copyright 2015 by ISA. All rights reserved. Not for resale. Printed in the United States of America. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means (electron

3、ic mechanical, photocopying, recording, or otherwise), without the prior written permission of the Publisher. ISA 67 Alexander Drive P.O. Box 12277 Research Triangle Park, North Carolina 27709 - 3 - ANSI/ISA-75.08.08-2015 Preface This preface, as well as all footnotes and annexes, is included for in

4、formation purposes and is not part of ANSI/ISA-75.08.08-2015. This document has been prepared as part of the service of ISA towards a goal of uniformity in the field of instrumentation. To be of real value, this document should not be static but should be subject to periodic review. Toward this end,

5、 the Society welcomes all comments and criticisms and asks that they be addressed to the Secretary, Standards and Practices Board; ISA; 67 Alexander Drive; P. O. Box 12277; Research Triangle Park, NC 27709; Telephone (919) 549-8411; Fax (919) 549-8288; E-mail: standardsisa.org. The ISA Standards and

6、 Practices Department is aware of the growing need for attention to the metric system of units in general, and the International System of Units (SI) in particular, in the preparation of instrumentation standards. The Department is further aware of the benefits to USA users of ISA standards of incor

7、porating suitable references to the SI (and the metric system) in their business and professional dealings with other countries. Toward this end, this Department will endeavor to introduce SI-acceptable metric units in all new and revised standards, recommended practices, and technical reports to th

8、e greatest extent possible. Standard for Use of the International System of Units (SI): The Modern Metric System, published by the American Society for Testing & Materials as IEEE/ASTM SI 10-97, and future revisions, will be the reference guide for definitions, symbols, abbreviations, and conversion

9、 factors. It is the policy of ISA to encourage and welcome the participation of all concerned individuals and interests in the development of ISA standards, recommended practices, and technical reports. Participation in the ISA standards-making process by an individual in no way constitutes endorsem

10、ent by the employer of that individual, of ISA, or of any of the standards, recommended practices, and technical reports that ISA develops. CAUTION ISA DOES NOT TAKE ANY POSITION WITH RESPECT TO THE EXISTENCE OR VALIDITY OF ANY PATENT RIGHTS ASSERTED IN CONNECTION WITH THIS DOCUMENT, AND ISA DISCLAI

11、MS LIABILITY FOR THE INFRINGEMENT OF ANY PATENT RESULTING FROM THE USE OF THIS DOCUMENT. USERS ARE ADVISED THAT DETERMINATION OF THE VALIDITY OF ANY PATENT RIGHTS, AND THE RISK OF INFRINGEMENT OF SUCH RIGHTS, IS ENTIRELY THEIR OWN RESPONSIBILITY. PURSUANT TO ISAS PATENT POLICY, ONE OR MORE PATENT HO

12、LDERS OR PATENT APPLICANTS MAY HAVE DISCLOSED PATENTS THAT COULD BE INFRINGED BY USE OF THIS DOCUMENT AND EXECUTED A LETTER OF ASSURANCE COMMITTING TO THE GRANTING OF A LICENSE ON A WORLDWIDE, NON-DISCRIMINATORY BASIS, WITH A FAIR AND REASONABLE ROYALTY RATE AND FAIR AND REASONABLE TERMS AND CONDITI

13、ONS. FOR MORE INFORMATION ON SUCH DISCLOSURES AND LETTERS OF ASSURANCE, CONTACT ISA OR VISIT WWW.ISA.ORG/STANDARDSPATENTS. OTHER PATENTS OR PATENT CLAIMS MAY EXIST FOR WHICH A DISCLOSURE OR LETTER OF ASSURANCE HAS NOT BEEN RECEIVED. ISA IS NOT RESPONSIBLE FOR IDENTIFYING PATENTS OR PATENT APPLICATIO

14、NS FOR WHICH A LICENSE MAY BE REQUIRED, FOR CONDUCTING INQUIRIES INTO THE LEGAL VALIDITY OR SCOPE OF PATENTS, OR DETERMINING WHETHER ANY LICENSING TERMS OR CONDITIONS PROVIDED IN CONNECTION WITH SUBMISSION OF A LETTER OF ASSURANCE, IF ANY, OR IN ANY LICENSING AGREEMENTS ARE REASONABLE OR NON-DISCRIM

15、INATORY. ANSI/ISA-75.08.08-2015 - 4 - ISA REQUESTS THAT ANYONE REVIEWING THIS DOCUMENT WHO IS AWARE OF ANY PATENTS THAT MAY IMPACT IMPLEMENTATION OF THE DOCUMENT NOTIFY THE ISA STANDARDS AND PRACTICES DEPARTMENT OF THE PATENT AND ITS OWNER. ADDITIONALLY, THE USE OF THIS DOCUMENT MAY INVOLVE HAZARDOU

16、S MATERIALS, OPERATIONS OR EQUIPMENT. THE DOCUMENT CANNOT ANTICIPATE ALL POSSIBLE APPLICATIONS OR ADDRESS ALL POSSIBLE SAFETY ISSUES ASSOCIATED WITH USE IN HAZARDOUS CONDITIONS. THE USER OF THIS DOCUMENT MUST EXERCISE SOUND PROFESSIONAL JUDGMENT CONCERNING ITS USE AND APPLICABILITY UNDER THE USERS P

17、ARTICULAR CIRCUMSTANCES. THE USER MUST ALSO CONSIDER THE APPLICABILITY OF ANY GOVERNMENTAL REGULATORY LIMITATIONS AND ESTABLISHED SAFETY AND HEALTH PRACTICES BEFORE IMPLEMENTING THIS DOCUMENT. THE USER OF THIS DOCUMENT SHOULD BE AWARE THAT THIS DOCUMENT MAY BE IMPACTED BY ELECTRONIC SECURITY ISSUES.

18、 THE COMMITTEE HAS NOT YET ADDRESSED THE POTENTIAL ISSUES IN THIS VERSION. The following people served as members of ISA Subcommittee ISA75.08 and approved ANSI/ISA-75.08.08-2015: NAME COMPANY W. Weidman, Chair Consultant H. Baumann H B Services Partners LLC G. Borden Consultant F. Cain Flowserve Co

19、rporation R. Duimstra Fisher Controls International LLC V. Mezzano Fluor Corporation J. Young The Dow Chemical Company The following people served as members of ISA Committee ISA75 and approved ANSI/ISA-75.08.08-2015: NAME COMPANY J. Young, Chair The Dow Chemical Company W. Weidman, Managing Directo

20、r Consultant A. Abromaitis S&T Design H. Baumann H B Services Partners LLC J. Beall Emerson Process Management M. Bober Copes-Vulcan H. Boger Consultant S. Boyle Metso Automation USA Inc. F. Cain Flowserve Corporation R. Duimstra Fisher Controls International LLC J. Faramarzi Control Components Inc.

21、 C. Hergert Kellogg Brown & Root H. Hoffmann Consultant J. Kiesbauer Samson Aktiengesellschaft A. Libke DeZURIK G. Liu Consultant T. Loudin Larox Flowsys Inc. D. Martin Valve Solutions Ltd. H. Maxwell Bechtel Power Corp. R. McEver Consultant V. Mezzano Fluor Corporation - 5 - ANSI/ISA-75.08.08-2015

22、H. Miller Consultant A. Sahraei Enbridge Pipelines Inc LP E. Skovgaard Consultant This standard was approved by the ISA Standards and Practices Board on 21 December 2015: NAME COMPANY N. Sands, Vice President DuPont D. Bartusiak ExxonMobil Research & Engineering P. Brett Honeywell Inc. E. Cosman OIT

23、 Concepts, LLC D. Dunn Phillips 66 J. Federlein Federlein & Assoc. Inc. B. Fitzpatrick Wood Group Mustang J. Gilsinn Kenexis Consulting J. Hauet KB Intelligence J. Jamison Encana Corp. K. P. Lindner Endress + Hauser Process Solutions AG V. Maggioli Feltronics Corp. T. McAvinew Instrumentation and Co

24、ntrol Engineering, LLC V. Mezzano Fluor Corporation C. Monchinski Automated Control Concepts Inc. H. Sasajima Azbil Corp. T. Schnaare Rosemount Inc. J. Tatera Tatera & Associates Inc. K. Unger Stone Technologies Inc. I. Verhappen Orbis Engineering Field Services W. Weidman WCW Consulting J. Weiss Ap

25、plied Control Solutions LLC M. Wilkins Yokogawa IA Global Marketing (USMK) D. Zetterberg Chevron Energy Technology Co. This page intentionally left blank. - 7 - ANSI/ISA-75.08.08-2015 CONTENTS 1 Scope . 9 2 Purpose 9 3 Definition . 9 4 Dimensional data 9 Annex A References . 11 This page intentional

26、ly left blank. - 9 - ANSI/ISA-75.08.08-2015 1 Scope This standard applies to raised-face flanged globe-style angle control valves, 1 inch through 8 inches. 2 Purpose The purpose of this standard is to aid users in their piping design by providing Classes 150, 300, and 600 raised-face flanged globe-s

27、tyle angle control valve face-to-centerline dimensions without giving special considerations to the equipment manufacturer to be used. 3 Definition This standard introduces no new terms requiring definition. Terms used are defined in ANSI/ISA-75.05.01, Control Valve Terminology. 4 Dimensional data F

28、or face-to-centerline dimensions for raised-face globe-style angle control valves, see Table 1. ANSI/ISA-75.08.08-2015 - 10 - Table 1 Angle valves Nominal valve size Dimensions A and B* Class 150 Class 300 Class 600 Tolerance mm inches mm inches mm inches mm inches mm inches 25 1 92 3.62 99 3.88 105

29、 4.12 01.6 0.062 40 1 111 4.37 117 4.62 125 4.94 01.6 0.062 50 2 127 5.00 133 5.25 143 5.62 01.6 0.062 80 3 149 5.88 159 6.25 168 6.62 01.6 0.062 100 4 176 6.94 184 7.25 197 7.75 01.6 0.062 150 6 226 8.88 236 9.31 254 10.00 01.6 0.062 200 8 272 10.69 284 11.19 305 12.00 01.6 0.062 *See Figure 1 Figu

30、re 1 Dimensions A and B and centerline - 11 - ANSI/ISA-75.08.08-2015 Annex A References The following bibliography is included for the definition of pressure classes, flange dimensions, material identification, and cross reference. AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) ANSI/ASME B16.5-2003

31、 Pipe Flanges and Flanged Fittings: NPS through 24 ANSI/ASME B16.34-2004 Valves Flanged, Threaded, and Welding End Available from: ASME Two Park Avenue New York, NY 10016-5990 Tel: (800) 843-2763 Email: infocentralasme.org INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) IEC 60534-3-1 (2000) Industri

32、al-Process Control Valves - Part 3-1: Dimensions - Face-to-Face Dimensions for Flanged, Two-Way, Globe-Type, Straight Pattern and Centre-to-Face Dimensions for Flanged, Two-Way, Globe-Type, Angle Pattern Control Valves Available from: IEC 3, rue de Varemb P.O. Box 131 CH - 1211 Geneva 20 Switzerland

33、 http:/www.iec.ch This page intentionally left blank. Developing and promulgating technically sound consensus standards, recommended practices, and technical reports is one of ISAs primary goals. To achieve this goal, the Standards and Practices Department relies on the technical expertise and effor

34、ts of volunteer committee members, chairmen, and reviewers. ISA is an American National Standards Institute (ANSI) accredited organization. ISA administers United States Technical Advisory Groups (USTAGs) and provides secretariat support for International Electrotechnical Commission (IEC) and Intern

35、ational Organization for Standardization (ISO) committees that develop process measurement and control standards. To obtain additional information on the Societys standards program, please write: ISA Attn: Standards Department 67 Alexander Drive P.O. Box 12277 Research Triangle Park, NC 27709 ISBN: 978-1-941546-85-7

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1