ANSI ISA 75.10.02-2014 Installed Face-to-Face Dimensions for Dual Pinch Flanged Clamp or Pinch Valves (Classes 125 and 150).pdf

上传人:花仙子 文档编号:436970 上传时间:2018-11-14 格式:PDF 页数:14 大小:250.76KB
下载 相关 举报
ANSI ISA 75.10.02-2014 Installed Face-to-Face Dimensions for Dual Pinch Flanged Clamp or Pinch Valves (Classes 125 and 150).pdf_第1页
第1页 / 共14页
ANSI ISA 75.10.02-2014 Installed Face-to-Face Dimensions for Dual Pinch Flanged Clamp or Pinch Valves (Classes 125 and 150).pdf_第2页
第2页 / 共14页
ANSI ISA 75.10.02-2014 Installed Face-to-Face Dimensions for Dual Pinch Flanged Clamp or Pinch Valves (Classes 125 and 150).pdf_第3页
第3页 / 共14页
ANSI ISA 75.10.02-2014 Installed Face-to-Face Dimensions for Dual Pinch Flanged Clamp or Pinch Valves (Classes 125 and 150).pdf_第4页
第4页 / 共14页
ANSI ISA 75.10.02-2014 Installed Face-to-Face Dimensions for Dual Pinch Flanged Clamp or Pinch Valves (Classes 125 and 150).pdf_第5页
第5页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、 AMERICAN NATIONAL STANDARD ANSI/ISA-75.10.02-2014 Supercedes ANSI/ISA-75.10.02-2008 Installed Face-to-Face Dimensions for Dual Pinch Flanged Clamp or Pinch Valves (Classes 125 and 150) Approved 15 April 2014 ANSI/ISA-75.10.02-2014, Installed Face-to-Face Dimensions for Dual Pinch Flanged Clamp or P

2、inch Valves (Classes 125 and 150) ISBN: 978-0-876640-84-5 Copyright 2014 by the International Society of Automation (ISA). All rights reserved. Not for resale. Printed in the United States of America. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any

3、form or by any means (electronic mechanical, photocopying, recording, or otherwise), without the prior written permission of the Publisher. ISA 67 Alexander Drive P.O. Box 12277 Research Triangle Park, North Carolina 27709- 3 - ANSI/ISA-75.10.02-2014 Preface This preface, as well as all footnotes an

4、d annexes, is included for information purposes and is not part of ANSI/ISA-75.10.02-2014. This document has been prepared as part of the service of ISA toward a goal of uniformity in the field of instrumentation. To be of real value, this document should not be static but should be subject to perio

5、dic review. Toward this end, the Society welcomes all comments and criticisms and asks that they be addressed to the Secretary, Standards and Practices Board; ISA; 67 Alexander Drive; P. O. Box 12277; Research Triangle Park, NC 27709; Telephone (919) 549-8411; Fax (919) 549-8288; E-mail: standardsis

6、a.org. The ISA Standards and Practices Department is aware of the growing need for attention to the metric system of units in general, and the International System of Units (SI) in particular, in the preparation of instrumentation standards. The Department is further aware of the benefits to USA use

7、rs of ISA standards of incorporating suitable references to the SI (and the metric system) in their business and professional dealings with other countries. Toward this end, this Department will endeavor to introduce SI-acceptable metric units in all new and revised standards, recommended practices,

8、 and technical reports to the greatest extent possible. Standard for Use of the International System of Units (SI): The Modern Metric System, published by the American Society for Testing & Materials as IEEE/ASTM SI 10-97, and future revisions, will be the reference guide for definitions, symbols, a

9、bbreviations, and conversion factors. It is the policy of ISA to encourage and welcome the participation of all concerned individuals and interests in the development of ISA standards, recommended practices, and technical reports. Participation in the ISA standards-making process by an individual in

10、 no way constitutes endorsement by the employer of that individual, of ISA, or of any of the standards, recommended practices, and technical reports that ISA develops. CAUTION ISA DOES NOT TAKE ANY POSITION WITH RESPECT TO THE EXISTENCE OR VALIDITY OF ANY PATENT RIGHTS ASSERTED IN CONNECTION WITH TH

11、IS DOCUMENT, AND ISA DISCLAIMS LIABILITY FOR THE INFRINGEMENT OF ANY PATENT RESULTING FROM THE USE OF THIS DOCUMENT. USERS ARE ADVISED THAT DETERMINATION OF THE VALIDITY OF ANY PATENT RIGHTS, AND THE RISK OF INFRINGEMENT OF SUCH RIGHTS, IS ENTIRELY THEIR OWN RESPONSIBILITY. PURSUANT TO ISAS PATENT P

12、OLICY, ONE OR MORE PATENT HOLDERS OR PATENT APPLICANTS MAY HAVE DISCLOSED PATENTS THAT COULD BE INFRINGED BY USE OF THIS DOCUMENT AND EXECUTED A LETTER OF ASSURANCE COMMITTING TO THE GRANTING OF A LICENSE ON A WORLDWIDE, NON-DISCRIMINATORY BASIS, WITH A FAIR AND REASONABLE ROYALTY RATE AND FAIR AND

13、REASONABLE TERMS AND CONDITIONS. FOR MORE INFORMATION ON SUCH DISCLOSURES AND LETTERS OF ASSURANCE, CONTACT ISA OR VISIT WWW.ISA.ORG/STANDARDSPATENTS. OTHER PATENTS OR PATENT CLAIMS MAY EXIST FOR WHICH A DISCLOSURE OR LETTER OF ASSURANCE HAS NOT BEEN RECEIVED. ISA IS NOT RESPONSIBLE FOR IDENTIFYING

14、PATENTS OR PATENT APPLICATIONS FOR WHICH A LICENSE MAY BE REQUIRED, FOR CONDUCTING INQUIRIES INTO THE LEGAL VALIDITY OR SCOPE OF PATENTS, OR DETERMINING WHETHER ANY LICENSING TERMS OR CONDITIONS PROVIDED IN CONNECTION WITH SUBMISSION OF A LETTER OF ASSURANCE, IF ANY, OR IN ANY LICENSING AGREEMENTS A

15、RE REASONABLE OR NON-DISCRIMINATORY. ANSI/ISA-75.10.01-2014 - 4 - ISA REQUESTS THAT ANYONE REVIEWING THIS DOCUMENT WHO IS AWARE OF ANY PATENTS THAT MAY IMPACT IMPLEMENTATION OF THE DOCUMENT NOTIFY THE ISA STANDARDS AND PRACTICES DEPARTMENT OF THE PATENT AND ITS OWNER. ADDITIONALLY, THE USE OF THIS D

16、OCUMENT MAY INVOLVE HAZARDOUS MATERIALS, OPERATIONS OR EQUIPMENT. THE DOCUMENT CANNOT ANTICIPATE ALL POSSIBLE APPLICATIONS OR ADDRESS ALL POSSIBLE SAFETY ISSUES ASSOCIATED WITH USE IN HAZARDOUS CONDITIONS. THE USER OF THIS DOCUMENT MUST EXERCISE SOUND PROFESSIONAL JUDGMENT CONCERNING ITS USE AND APP

17、LICABILITY UNDER THE USERS PARTICULAR CIRCUMSTANCES. THE USER MUST ALSO CONSIDER THE APPLICABILITY OF ANY GOVERNMENTAL REGULATORY LIMITATIONS AND ESTABLISHED SAFETY AND HEALTH PRACTICES BEFORE IMPLEMENTING THIS DOCUMENT. THE USER OF THIS DOCUMENT SHOULD BE AWARE THAT THIS DOCUMENT MAY BE IMPACTED BY

18、 ELECTRONIC SECURITY ISSUES. THE COMMITTEE HAS NOT YET ADDRESSED THE POTENTIAL ISSUES IN THIS VERSION. The following people served as members of ISA75.10: NAME COMPANY A. Abromaitis, Chair S&T Design W. Weidman, Managing Director WCW Consulting L. Aanonsen General Rubber Corporation J. Allman EVR Pr

19、oducts J. Faramarzi Control Components Inc. E. Feldmann RF Valves Inc. D. Gardellin Onyx Valve Company G. Liu Consultant T. Loudin Flowrox Inc. V. Mezzano Fluor Corporation G. Richards Richards Industries Inc. J. Young The Dow Chemical Company The following people served as members of ISA Committee

20、ISA75: NAME COMPANY J. Young, Chair The Dow Chemical Company W. Weidman, Managing Director WCW Consulting L. Al-Awami Saudi Aramco H. Baumann HB Services Partners LLC J. Beall Emerson Process Management M. Bober Copes-Vulcan H. Boger GE Oil & Gas G. Borden Consultant S. Boyle Metso Automation USA In

21、c. F. Cain Flowserve Corporation R. Duimstra Fisher Controls International Inc. J. Faramarzi* Control Components Inc. J. George Richards Industries C. Hergert Kellogg Brown & Root H. Hoffmann Consultant J. Jamison Spectra Energy Ltd. J. Kiesbauer Samson Aktiengesellschaft A. Libke DeZurik G. Liu Con

22、sultant T. Loudin Flowrox Inc. - 5 - ANSI/ISA-75.10.02-2014 H. Maxwell Bechtel Power Corporation J. McCaskill Expro Group R. McEver Consultant V. Mezzano Fluor Corporation H. Miller* Control Components Inc. T. Molloy CMES Inc. A. Sahraei Enbridge Pipelines Inc. LP E. Skovgaard Control Valve Solution

23、s _ *One vote per company. This standard was approved for publication by the ISA Standards and Practices Board on 14 January 2014. NAME COMPANY E. Cosman, Vice President The Dow Chemical Company D. Bartusiak ExxonMobil Chemical Company P. Brett Honeywell Inc. J. Campbell Consultant M. Coppler Det No

24、rske Veritas Certification Inc. B. Dumortier Schneider Electric D. Dunn Consultant J. Federlein Federlein & Assoc. Inc. J. Gilsinn Kenexis Consulting E. Icayan Atkins J. Jamison Spectra Energy Ltd. K. Lindner Endress+Hauser Process Solutions AG V. Maggioli Feltronics Corporation T. McAvinew Instrume

25、ntation and Control Engineering LLC V. Mezzano Fluor Corporation C. Monchinski Automated Control Concepts Inc. R. Reimer Rockwell Automation S. Russell Valero Energy Corporation N. Sands DuPont H. Sasajima Azbil Corporation T. Schnaare Rosemount Inc. J. Tatera Tatera & Associates Inc. I. Verhappen I

26、ndustrial Automation Networks Inc. W. Weidman WCW Consulting J. Weiss Applied Control Solutions LLC M. Wilkins Yokogawa IA Global Marketing USMK D. Zetterberg Chevron Energy Technology Company This page intentionally left blank. - 7 - ANSI/ISA-75.10.02-2014 Contents 1 Scope 9 2 Purpose . 9 3 Table 1

27、 - Pinch valve design in inches (in millimeters), face-to-face dimensions and tolerances 10 4 Dimensional data of installed pinch valves . 11 5 Definitions 11 6 References 12 This page intentionally left blank. - 9 - ANSI/ISA-75.10.02-2014 1 Scope This document applies to valves, sizes NPS (DN 15) t

28、hrough NPS 26 (DN 650), of the clamp or pinch valve design incorporating clamp or pinch elements. 2 Purpose The purpose of this document is to aid users in piping design by providing installed face -to-face dimensions for control valves that incorporate clamp or pinch elements and have flanges that

29、mate with ANSI B16.1 Class 125 and/or ANSI B16.5 Class 150 flanges. This document also applies to handwheel-operated pinch valves, which have flanges that mate with Classes 125 and 150, but excludes solenoid-actuated valves and direct fluid-actuated valves. Due to the extensive variety in applicatio

30、ns for pinch valves, it is not reasonable to standardize on only one set. Some applications are better suited to a shorter face-to-face, whereas others need extra length. Users of pinch valves are advised to discuss with the pinch valve manufacturers based on their requirements, their unique process

31、 conditions, and the type of elastomer or rubber used. All face-to-face dimensions in this document have been applied successfully throughout industry. ANSI/ISA-75.10.01-2014 - 10 - 3 Table 1 - Pinch valve design in inches (in millimeters), face-to-face dimensions and tolerances Table 1 - Full bore

32、design pinch valves in inches (in millimeters) and tolerances in inches (in millimeters) Size Short Medium Long Tolerances 0.5 4.25 (108) 7.25 (184) +/- 0.062 in. (+/- 1.575 mm) 0.75 4.82 (122) 7.25 (184) 1 5.5 (140) 6.5 (165) 7.25 (184) 1.5 6.5 (165) 8.75 (222) 2 6.5 (165) 7 (178) 10 (254) 2.5 6.5

33、(165) 7.5 (191) 10.87 (276) 3 8 (203) 11.75 (298) 4 9 (229) 10 (254) 13.87 (352) +/- 0.125 in. (+/- 3.175 mm) 5 10 (254) 12.2 (310) 17.75 (451) 6 10.5 (267) 15 (381) 17.75 (451) 8 18 (457) 19.75 (502) 21.37 (543) 10 21 (533) 24.75 (629) 26.5 (673) +/-0.187 in. (+/- 4.750 mm) 12 24 (610) 29 (737) 29.

34、75 (756) 14 27 (686) 28 (711) 35 (889) 16 30 (762) 32 (813) 39.5 (1,003) 18 34 (864) 36 (914) 44.5 (1,130) +/- 0.250 in. (+/- 6.350 mm) 20 36 (914) 40 (1,016) 49.5 (1,257) 24 42 (1,067) 48 (1,219) 59 (1,499) 26 64 (1,626) +/- 0.118 in. (+/- 3 mm) - 11 - ANSI/ISA-75.10.02-2014 4 Dimensional data of i

35、nstalled pinch valves For face-to-face dimensions (A), for flanged clamp or pinch valves, see Table 1 in inches (in millimeters). Figure 1 Installed face-to-face dimension “A“ 5 Definitions For definitions of terms used in this document, see ANSI/ISA-75.05.01, Control Valve Terminology. 5.1 one-piec

36、e element clamp or pinch valve a valve consisting of a one-piece flexible element or liner installed in a body with the element or liner extending over the flange faces and acting as a gasket between the valve and connecting piping. Valves may be specified in any of the common face-to-face dimension

37、s shown in Table 1 in inches (in millimetres). 5.2 two-piece element clamp or pinch valve: a two-piece element clamp or pinch valve is a valve consisting of two flexible elastomeric elements or liners installed between a two-piece flanged body. The flexible elements or liners also extend over the fl

38、ange faces and act as gaskets between the valve and the connecting piping. 5.3 face-to-face: each of the face-to-face dimensions in Table 1 is to be applied to the installed length of the valve after installation into a piping system. The free length face-to-face dimension of a valve before installa

39、tion into a piping system may be slightly longer than dimensions shown in each of the tables. The free length face-to-face dimension of a pinch valve before installation into a piping system (known as the soft face-to-face dimension in pinch valves) is often longer than the dimensions in Table 1 to

40、allow for installed compression of the elastomeric liner face. ANSI/ISA-75.10.01-2014 - 12 - 6 References The American Society of Mechanical Engineers (ASME), ASME/ANSI B16.1 Cast Iron Pipe Flanges and Flanged Fittings - Class 125 ASME, ASME/ANSI B16.5 Pipe Flanges and Flanged Fittings ASME, ANSI/AS

41、ME B16.10, Face-to-Face and End-to-End Dimensions of Valves. ISA, ANSI/ISA-75.05.01, Control Valve Terminology. Manufacturers Standardization Society of the Valve and Fittings Industry, Inc. (MSS), SP-72, Ball Valves with Flanged or Butt-Welding Ends for General Service. Developing and promulgating

42、sound consensus standards, recommended practices, and technical reports is one of ISAs primary goals. To achieve this goal the Standards and Practices Department relies on the technical expertise and efforts of volunteer committee members, chairmen and reviewers. ISA is an American National Standard

43、s Institute (ANSI) accredited organization. ISA administers United States Technical Advisory Groups (USTAGs) and provides secretariat support for International Electrotechnical Commission (IEC) and International Organization for Standardization (ISO) committees that develop process measurement and control standards. To obtain additional information on the Societys standards program, please write: ISA Attn: Standards Department 67 Alexander Drive P.O. Box 12277 Research Triangle Park, NC 27709 ISBN: 978-0-876640-84-5

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1