1、NEMA Standards PublicationNational Electrical Manufacturers AssociationANSI/NEMA C29.11-2012Composite Insulators Test MethodsC29.11-2012 Page i Copyright 2012 by National Electrical Manufacturers Association ANSI/NEMA C29.11-2012 American National Standard Composite Insulators Test Methods Secretari

2、at: National Electrical Manufacturers Association Approved: June 2012 Published: October 11, 2012 American National Standards Institute, Inc. C29.11-2012 Page ii Copyright 2012 by National Electrical Manufacturers Association NOTICE AND DISCLAIMER The information in this publication was considered t

3、echnically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this document. American National Standards I

4、nstitute (ANSI) standards and guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards development process. This process brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by t

5、his publication. While NEMA administers the process and establishes rules to promote fairness in the development of consensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments cont

6、ained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance

7、 on this document. NEMA disclaims and makes no guaranty or warranty, express or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. NEMA does

8、not undertake to guarantee the performance of any individual manufacturer or sellers products or services by virtue of this standard or guide. In publishing and making this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or entity,

9、nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumst

10、ances. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not covered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with t

11、he contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any health or safetyrelated information in this document shall not be attributable to NEMA and is solely th

12、e responsibility of the certifier or maker of the statement.C29.11-2012 Page iii Copyright 2012 by National Electrical Manufacturers Association AMERICAN NATIONAL STANDARD Approval of an American National Standard requires verification by ANSI that the requirements for due process, consensus, and ot

13、her criteria for approval have been met by the standards developer. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means much more than a simple majority

14、, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effort be made toward their resolution. The use of American National Standards is completely voluntary; their existence does not in any respect preclude anyone, whether he has approv

15、ed the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. The American National Standards Institute does not develop standards and will in no circumstances give an interpretation of any American National Standard.

16、 Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standards Institute. Requests for interpretations should be addressed to the secretariat or sponsor whose name appears on the title page of this sta

17、ndard. Caution Notice: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken periodically to reaffirm, revise, or withdraw this standard. Purchasers of American National Standards may receive

18、current information on all standards by calling or writing the American National Standards Institute. Published by National Electrical Manufacturers Association 1300 North 17th Street, Rosslyn, VA 22209 g164 Copyright 2012 by National Electrical Manufacturers Association All rights reserved includin

19、g translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American Copyright Conventions. No part of this publication may be reproduced in any form, in an electronic ret

20、rieval system or otherwise, without the prior written permission of the publisher. Printed in the United States of America. C29.11-2012 Page iv Copyright 2012 by National Electrical Manufacturers Association FOREWORD (This Foreword is not part of American National Standard C29.11-2012.) The first ed

21、ition of this standard was based on a NEMA proposed standards publication for composite insulators used on overhead transmission lines. It was developed at the request of American National Standards Committee on Insulators for Electric Power Lines, ASC C-29. This standard was processed and approved

22、for submittal to ANSI by ASC C-29. Committee approval of the standard does not necessarily imply that all committee members voted for approval. At the time it approved this standard, the ASC C-29 Committee had the following members: Rob Christman, Chairman Steve Griffith, Secretary Organization Repr

23、esented: Name of Representative: Edison Electric Institute B. Freimark R. ChristmnEleckley M. GarsWAvey J. Varnr(alt) R. Kluge (alt)G. Obenchain (alt) Institute of Electrical and Electronic Engineers T. Grisham J Hildeth A. Jagtiani J. Kufel A. PhillipsE. Gnandt (alt) National Electrical Manufacture

24、rs Association P. Maloney A. BakerRA. nstorf GPowel . AStwart EKres (l)Z. Lodi (alt) E. Niedospial (alt) A. Schwalm lt)Tennessee Valley Authority J. Nelson Western Area Power Administration R. Clark C29.11-2012 Page v Copyright 2012 by National Electrical Manufacturers Association C29.11-2012 Page v

25、i Copyright 2012 by National Electrical Manufacturers Association TABLE OF CONTENTS Page FOREWORD iv 1 SCOPE . 1 2 NORMATIVE REFERENCES . 1 2.1 Referenced American National Standards 1 2.2 Other standards 1 3 DEFINITIONS . 1 3.1 Insulators and Parts 1 3.1.1 Insulator . 1 3.1.2 Line and Apparatus Pos

26、t Insulator . 2 3.1.3 Suspension Insulator 2 3.1.4 Composite Insulator . 2 3.1.5 Core . 2 3.1.6 Housing 2 3.1.7 Weathersheds 2 3.1.8 End Fittings 2 3.1.9 Coupling Zone 2 3.1.10 Interfaces . 2 3.2 Terms Related to Exposure 2 3.2.1 Tracking . 2 3.2.2 Erosion . 3 3.3 Electrical Terms 3 3.3.1 Low-Freque

27、ncy . 3 3.3.2 Low-Frequency Flashover Voltage . 3 3.3.3 Low-Frequency Withstand Voltage 3 3.3.4 Impulse Voltages 3 3.4 Mechanical Terms . 4 3.4.1 Specified Mechanical Load (SML) . 4 3.4.2 Routine Test Load (RTL) 4 3.4.3 Specified Cantilever Load (SCL) . 4 3.4.4 Cantilever Breaking Load (CBL) 4 3.4.5

28、 Reference Cantilever Load (RCL) 4 3.4.6 Ultimate Mechanical Strength.4 3.4.7 Specified Tensile Load (STL) .4 3.5 Miscellaneous 5 3.5.1 Test Specimen . 5 3.5.2 Leakage Distance 5 3.5.3 Dry-Arcing Distance 5 3.5.4 Radio-Influence Voltage . 5 4 CLASSIFICATION OF TESTS . 6 4.1 Prototype Tests . 6 4.2 D

29、esign Tests . 6 4.2.1 Electrical Design 6 4.2.2 Mechanical Design . 6 4.3 Sample Tests 6 4.4 Routine Tests 6 C29.11-2012 Page vii Copyright 2012 by National Electrical Manufacturers Association 5 DIMENSIONS . 6 6 MARKING 7 7 PROTOTYPE TESTS . 7 7.1 Tests on Interfaces and Connection of End Fittings

30、. 7 7.1.1 Test Specimens . 7 7.1.2 Low Frequency Dry Flashover Voltage Test 7 7.1.3 Sudden Load Release Test-Suspension Insulators Only . 7 7.1.4 Thermal Mechanical Tests . 8 7.1.5 Water Penetration Test 8 7.1.6 Verification Tests 9 7.2 Core Time-Load Test 9 7.2.1 Suspension Insulators 9 7.2.2 Line

31、Posts 10 7.3 Housing Tracking and Erosion Tests 10 7.3.1 Test Specimens . 10 7.3.2 Test Chamber 10 7.3.3 Test Conditions 11 7.3.4 Evaluation . 12 7.4 Core Material Tests . 12 7.4.1 Dye Penetration Test 12 7.4.2 Water Diffusion Test 13 7.5 Flammability Test 13 8 DESIGN TESTS . 13 8.1 Test-Specimen Mo

32、unting for Electrical Tests . 13 8.1.1 Suspension Insulators 14 8.1.2 Line Insulators (Post) . 14 8.1.3 Apparatus Insulators (Post) 14 8.2 Electrical Tests 15 8.2.1 Low-Frequency Voltage Dry Flashover Test 15 8.2.2 Low-Frequency Voltage Wet Flashover Test . 17 8.2.3 Low-Frequency Voltage Dry Withsta

33、nd Test 17 8.2.4 Low-Frequency Wet Withstand Test 18 8.2.5 Switching Critical-Impulse Flashover Test . 20 8.2.6 Impulse Flashover Voltage Tests . 20 8.2.7 Impulse Withstand Voltage Test 20 8.2.8 Radio-Influence Voltage Tests . 21 8.3 Mechanical Tests 22 8.3.1 Ultimate Mechanical-Strength Tests 22 8.

34、3.2 Compression Withstand Load Test (Post) . 23 9 SAMPLE TESTS 24 9.1 Sample Selection 24 9.2 Verification of Dimensions . 24 9.3 Verification of the Locking System 24 9.4 Mechanical Load Test-Tension . 24 9.4.1 Test Samples . 24 9.4.2 Suspension Insulators (SML) . 24 9.4.3 Line Post Insulators (STL

35、) . 25 9.5 Verification of Cantilever Strength Test (Pin, Post) . 25 9.5.1 Test Setup 25 9.5.2 Cantilever Strength Verification 25 9.5.3 Cantilever Breaking Load (CBL) Test 25 C29.11-2012 Page viii Copyright 2012 by National Electrical Manufacturers Association 9.6 Galvanizing Test 25 9.7 Retest Pro

36、cedure for Sample Tests 26 10 ROUTINE TESTS . 26 10.1 Mechanical Tests 26 10.1.1 Suspension Insulators 26 10.1.2 Line and Apparatus Post Insulators . 26 10.2 Visual Examinations 26 ANNEX AA-1 FIGURES 10-1 LOW-FREQUENCY HUMIDITY CORRECTION FACTORS . 27 10-2 IMPULSE HUMIDITY CORRECTION FACTORS . 27 10

37、-3 THERMAL MECHANICAL TEST (SUSPENSION INSULATORS). . 28 10-4 THERMAL MECHANICAL TEST (LINE POST). . 29 10-5 THERMAL MECHANICAL TEST (LINE POST 70 KV) . 30 10-6 ELECTRODES FOR CORE MATERIAL TEST . 31 C29.11-2012 Page ix Copyright 2012 by National Electrical Manufacturers Association C29.11-2012 Page

38、 1 Copyright 2012 by National Electrical Manufacturers Association Composite InsulatorsTest Methods 1 SCOPE This standard comprises a manual of test methods to be followed in making tests to determine the characteristics of composite electrical power insulators, as defined herein. 2 NORMATIVE REFERE

39、NCES 2.1 Referenced American National Standards This standard is intended to be used in conjunction with the following American National Standards. When these standards are superseded by a revision approved by the American National Standards Institute, the revision shall apply. ANSI C29.1-1988 (R200

40、2, R2012) Test Methods of Electrical Power Insulators ANSI/IEEE 4-1995 Techniques for High-Voltage Testing ANSI/IEEE 100-1984 Dictionary of Electrical and Electronics Terms 2.2 Other Standards IEC 60695-11-10 Fire Hazard Testing Part 11-10: Test Flames 50 W Horizontal and Vertical Flame Test Methods

41、 NEMA 107-1987 (R1993) Methods of Measurement of Radio Influence Voltage (RIV) of High-Voltage Apparatus ISO-3452-1: 2008 Non-Destructive TestingPenetrant Testing Part 1: General Principles ASTM B499-09 Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method; Nonmagnetic C

42、oatings on Magnetic Basis Metals. 3 DEFINITIONS 3.1 Insulators and Parts 3.1.1 InsulatorTypes 3.1.1.1 Composite Insulator A composite insulator is made of at least two insulating parts - a core and a housing. It is equipped with end fittings. A composite insulator is a manufactured device intended t

43、o give flexible or rigid mechanical support to electric conductors or equipment while electrically separating these conductors or equipment from ground or from other conductors or equipment. 3.1.1.2 Line and Apparatus Post Insulators A post insulator is an insulator with attached metal parts having

44、means for direct and rigid mounting to a supporting structure and for semi-rigidly supporting conductors. AMERICAN NATIONAL STANDARD ANSI/NEMA C29.11-2012 C29.11-2012 Page 2 Copyright 2012 by National Electrical Manufacturers Association 3.1.1.3 Suspension Insulator A suspension insulator is an insu

45、lator with attached metal parts having means for non-rigidly supporting electric conductors. 3.1.2 Insulator Parts 3.1.2.1 Core The core is the internal insulating part of a composite insulator. It is intended to carry the mechanical load. It consists mainly of glass fibers positioned in a resin mat

46、rix to develop mechanical strength. 3.1.2.2 Housing The housing is external to the core and protects it from the weather, it may be equipped with weathersheds. Some designs of composite insulators employ a sheath made of insulating material between the weathersheds and the core. This sheath is part

47、of the housing. 3.1.2.3 Weathersheds Weathersheds are insulating parts projecting from the housing or sheath that are intended to increase the leakage distance and to provide an interrupted path for water drainage. 3.1.2.4 End Fittings End fittings transmit the mechanical load to the core. 3.1.2.5 C

48、oupling Zone The coupling zone is the part of the end fitting that transmits the load to the line, to the structure, or to another insulator. It does not include the interface between the core and the end fitting. 3.1.2.6 Interfaces An interface is the surface between different materials. Examples o

49、f interfaces in composite insulators are as follows: a) Glass fiber/impregnating resin b) Filler/polymer c) Core/housing d) Weathershed/weathershed e) Weathershed/sheath f) Housing/end fittings g) Core/end fittings Note: Definitions as given in this section apply specifically to the subjects treated in this standard. For additional definitions, see ANSI/IEEE 100-1984. 3.2 Terms Related to Exposure 3.2.1 Tracking Tracking is the formation of

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1