ANSI ST24-1999 Automatic general purpose ethylene oxide sterilizers and ethylene oxide sterilant sources intended for use in health care facilities.pdf

上传人:inwarn120 文档编号:438011 上传时间:2018-11-14 格式:PDF 页数:32 大小:266.45KB
下载 相关 举报
ANSI ST24-1999 Automatic general purpose ethylene oxide sterilizers and ethylene oxide sterilant sources intended for use in health care facilities.pdf_第1页
第1页 / 共32页
ANSI ST24-1999 Automatic general purpose ethylene oxide sterilizers and ethylene oxide sterilant sources intended for use in health care facilities.pdf_第2页
第2页 / 共32页
ANSI ST24-1999 Automatic general purpose ethylene oxide sterilizers and ethylene oxide sterilant sources intended for use in health care facilities.pdf_第3页
第3页 / 共32页
ANSI ST24-1999 Automatic general purpose ethylene oxide sterilizers and ethylene oxide sterilant sources intended for use in health care facilities.pdf_第4页
第4页 / 共32页
ANSI ST24-1999 Automatic general purpose ethylene oxide sterilizers and ethylene oxide sterilant sources intended for use in health care facilities.pdf_第5页
第5页 / 共32页
亲,该文档总共32页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、ANSI/AAMI ST24:1999/(R)2013Automatic, general purposeethylene oxide sterilizers and ethylene oxide sterilant sources intended for use in health care facilities American National StandardObjectives and uses of AAMI standards and recommended practices It is most important that the objectives and poten

2、tial uses of an AAMI product standard or recommended practice are clearly understood. The objectives of AAMIs technical development program derive from AAMIs overall mission: the advancement of medical instrumentation. Essential to such advancement are (1) a continued increase in the safe and effect

3、ive application of current technologies to patient care, and (2) the encouragement of new technologies. It is AAMIs view that standards and recommended practices can contribute significantly to the advancement of medical instrumentation, provided that they are drafted with attention to these objecti

4、ves and provided that arbitrary and restrictive uses are avoided. A voluntary standard for a medical device recommends to the manufacturer the information that should be provided with or on the product, basic safety and performance criteria that should be considered in qualifying the device for clin

5、ical use, and the measurement techniques that can be used to determine whether the device conforms with the safety and performance criteria and/or to compare the performance characteristics of different products. Some standards emphasize the information that should be provided with the device, inclu

6、ding performance characteristics, instructions for use, warnings and precautions, and other data considered important in ensuring the safe and effective use of the device in the clinical environment. Recommending the disclosure of performance characteristics often necessitates the development of spe

7、cialized test methods to facilitate uniformity in reporting; reaching consensus on these tests can represent a considerable part of committee work. When a drafting committee determines that clinical concerns warrant the establishment of minimum safety and performance criteria, referee tests must be

8、provided and the reasons for establishing the criteria must be documented in the rationale. A recommended practice provides guidelines for the use, care, and/or processing of a medical device or system. A recommended practice does not address device performance per se, but rather procedures and prac

9、tices that will help ensure that a device is used safely and effectively and that its performance will be maintained. Although a device standard is primarily directed to the manufacturer, it may also be of value to the potential purchaser or user of the device as a frame of reference for device eval

10、uation. Similarly, even though a recommended practice is usually oriented towards healthcare professionals, it may be useful to the manufacturer in better understanding the environment in which a medical device will be used. Also, some recommended practices, while not addressing device performance c

11、riteria, provide guidelines to industrial personnel on such subjects as sterilization processing, methods of collecting data to establish safety and efficacy, human engineering, and other processing or evaluation techniques; such guidelines may be useful to health care professionals in understanding

12、 industrial practices. In determining whether an AAMI standard or recommended practice is relevant to the specific needs of a potential user of the document, several important concepts must be recognized: All AAMI standards and recommended practices are voluntary (unless, of course, they are adopted

13、 by government regulatory or procurement authorities). The application of a standard or recommended practice is solely within the discretion and professional judgment of the user of the document. Each AAMI standard or recommended practice reflects the collective expertise of a committee of health ca

14、re professionals and industrial representatives, whose work has been reviewed nationally (and sometimes internationally). As such, the consensus recommendations embodied in a standard or recommended practice are intended to respond to clinical needs and, ultimately, to help ensure patient safety. A

15、standard or recommended practice is limited, however, in the sense that it responds generally to perceived risks and conditions that may not always be relevant to specific situations. A standard or recommended practice is an important reference in responsible decision-making, but it should never rep

16、lace responsible decision-making. Despite periodic review and revision (at least once every five years), a standard or recommended practice is necessarily a static document applied to a dynamic technology. Therefore, a standards user must carefully review the reasons why the document was initially d

17、eveloped and the specific rationale for each of its provisions. This review will reveal whether the document remains relevant to the specific needs of the user. Particular care should be taken in applying a product standard to existing devices and equipment, and in applying a recommended practice to

18、 current procedures and practices. While observed or potential risks with existing equipment typically form the basis for the safety and performance criteria defined in a standard, professional judgment must be used in applying these criteria to existing equipment. No single source of information wi

19、ll serve to identify a particular product as “unsafe“. A voluntary standard can be used as one resource, but the ultimate decision as to product safety and efficacy must take into account the specifics of its utilization and, of course, cost-benefit considerations. Similarly, a recommended practice

20、should be analyzed in the context of the specific needs and resources of the individual institution or firm. Again, the rationale accompanying each AAMI standard and recommended practice is an excellent guide to the reasoning and data underlying its provision. In summary, a standard or recommended p

21、ractice is truly useful only when it is used in conjunction with other sources of information and policy guidance and in the context of professional experience and judgment. INTERPRETATIONS OF AAMI STANDARDS AND RECOMMENDED PRACTICES Requests for interpretations of AAMI standards and recommended pra

22、ctices must be made in writing, to the AAMI Vice President, Standards Policy and Programs. An official interpretation must be approved by letter ballot of the originating committee and subsequently reviewed and approved by the AAMI Standards Board. The interpretation will become official and represe

23、ntation of the Association only upon exhaustion of any appeals and upon publication of notice of interpretation in the “Standards Monitor“ section of the AAMI News. The Association for the Advancement of Medical Instrumentation disclaims responsibility for any characterization or explanation of a st

24、andard or recommended practice which has not been developed and communicated in accordance with this procedure and which is not published, by appropriate notice, as an official interpretation in the AAMI News. American National Standard ANSI/AAMI ST24:1999/(R)2013(Revision of ANSI/AAMI ST24:1992)Aut

25、omatic, general-purpose ethylene oxidesterilizers and ethylene oxide sterilant sourcesintended for use in health care facilitiesDeveloped byAssociation for the Advancement of Medical InstrumentationApproved 27 May 1999 and reaffirmed 26 November 2013 byAmerican National Standards Institute, Inc.Abst

26、ract: This standard covers minimum labeling, safety, performance, and testing requirements forethylene oxide sterilizers that are intended for general-purpose use in health care facilities andthat have automatic controls. It also covers labeling, product composition, and containerrequirements for et

27、hylene oxide sterilant sources, as well as labeling, performance, safety, andinstallation requirements for ethylene oxide emission control systems.Keywords: ethylene oxide sterilization, ethylene oxide emission controlAAMI StandardThis Association for the Advancement of Medical Instrumentation (AAMI

28、) standard implies a consensus of thosesubstantially concerned with its scope and provisions. The existence of an AAMI standard does not in any respectpreclude anyone, whether they have approved the standard or not, from manufacturing, marketing, purchasing, or usingproducts, processes, or procedure

29、s not conforming to the standard. AAMI standards are subject to periodic review, andusers are cautioned to obtain the latest editions.CAUTION NOTICE: This AAMI standard may be revised or withdrawn at any time. AAMI procedures require that actionbe taken to reaffirm, revise, or withdraw this standard

30、 no later than 5 years from the date of publication. Interestedparties may obtain current information on all AAMI standards by calling or writing AAMI.Published byAssociation for the Advancement of Medical Instrumentation1110 N. Glebe Road, Suite 220Arlington, VA 22201-5762 2000 by the Association f

31、or the Advancement of Medical InstrumentationAll Rights ReservedThis publication is subject to copyright claims of AAMI. No part of this publication may be reproduced or distributed in anyform, including an electronic retrieval system, without the prior written permission of AAMI. All requests perta

32、ining to thisdraft should be submitted to AAMI. It is illegal under federal law (17 U.S.C. 101, et seq.) to make copies of all or any partof this document (whether internally or externally) without the prior written permission of the Association for theAdvancement of Medical Instrumentation. Violato

33、rs risk legal action, including civil and criminal penalties, and damagesof $100,000 per offense. For permission regarding the use of all or any part of this document, contact Kurt C. Larrick,Director, Technical Publishing, at AAMI, 1110 N. Glebe Road, Suite 220, Arlington, VA 22201. Phone: (703) 52

34、5-4890,Ext. 239; Fax: (703) 525-1067.Printed in the United States of AmericaISBN 1-57020-119-6ContentsPageCommittee representation. vAcknowledgmentviiForeword .viii1 Scope. 11.1 General 11.2 Inclusions 11.3 Exclusions . 12 Normative references. 13 Definitions, symbols, and abbreviations. 24 Requirem

35、ents. 34.1 Requirements for EO sterilizers. 34.1.1 Labeling. 34.1.2 Sterilizer construction, components, and accessories 44.1.3 Sterilizer safety 44.1.4 Process monitoring devices 54.1.5 Physical performance of sterilizers . 54.1.6 Biological performance of sterilizers . 54.1.7 Certification and rec

36、ordkeeping 54.2 Requirements for EO sterilant sources 54.2.1 Registration. 54.2.2 Labeling. 64.2.3 Container safety 64.2.4 Product composition 64.2.5 Shipping 64.3 Requirements for EO emission control systems 64.3.1 System approvals 64.3.2 Labeling. 64.3.3 Performance requirements 74.3.4 Safety requ

37、irements 74.3.5 Installation requirements. 75 Tests 7AnnexesA Rationale for the development and provisions of this standard . 11B Calculating chamber relative humidity . 15C Calculating chamber ethylene oxide concentration17D Bibliography 21Tables1 Test pack number and location for empty-chamber tes

38、ting . 92 Number of test packs for simulated-load testing 9B.1 Temperature versus saturation pressure of water vapor 15C.1 EO/diluent constants and molecular weights 18C.2 Gas constants (R = PV/nt) 18FigureB.1 Relative humidity versus partial pressure for two common sterilization temperatures. 16 19

39、99 Association for the Advancement of Medical Instrumentation onesansinv ANSI/AAMI ST24:1999 vCommittee representationAssociation for the Advancement of Medical InstrumentationSterilization Standards CommitteeThis standard was developed by the AAMI Hospital EO Sterilizer Working Group under the ausp

40、ices of the AAMISterilization Standards Committee. Committee approval of the standard does not necessarily mean that allcommittee and working group members voted for its approval.The AAMI Sterilization Standards Committee has the following members:Cochairs: Virginia C. Chamberlain, PhDWilliam E. You

41、ngMembers: Carl W. Bruch, PhD, Consultant, Hudson, WIVirginia C. Chamberlain, PhD, VC Chamberlain and Associates, Hendersonville, NCNeal E. Danielson, Ds Enterprise, Wichita, KSJudith Dowler, Medical Devices Bureau, Health Canada, Ottawa, ONFrank B. Engley, Jr., PhD, University of Missouri, Columbia

42、, MOVictoria Hitchins, PhD, U.S. Food and Drug AdministrationRobert Morrissey, PhD, Johnson “should” indicates that among several possibilities one is recommended as particularly suitable,without mentioning or excluding others, or that a certain course of action is preferred but not necessarily requ

43、ired, orthat (in the negative form) a certain possibility or course of action should be avoided but is not prohibited; “may” isused to indicate that a course of action is permissible within the limits of the standard; and “can” is used as astatement of possibility and capability. “Must” is used only

44、 to describe “unavoidable” situations, including thosemandated by government regulation.This standard should be considered flexible and dynamic. As technology advances and as new data are broughtforward, the standard will be reviewed and, if necessary, revised.Suggestions for improving this standard

45、 are invited. Comments and suggested revisions should be sent to TechnicalPrograms, AAMI, 3330 Washington Boulevard, Suite 400, Arlington, VA 22201-4598.NOTEThis foreword does not contain provisions of the American National Standard, Automatic, general-purposeethylene oxide sterilizers and ethylene

46、oxide sterilant sources intended for use in health care facilities (ANSI/AAMIST24:1999), but it does provide important information about the development and intended use of the document. 1999 Association for the Advancement of Medical Instrumentation onesansinv ANSI/AAMI ST24:1999 1American National

47、 Standard ANSI/AAMI ST24:1999/(R)2013Automatic, general-purpose ethylene oxidesterilizers and ethylene oxide sterilant sourcesintended for use in health care facilities1 Scope1.1 GeneralThis standard applies to automatic, general-purpose ethylene oxide (EO) sterilizers and EO sterilant sources that

48、areintended for use in hospitals and other health care facilities.NOTEFor purposes of this standard, “health care facilities” means hospitals, nursing homes, extended-care facilities,freestanding surgical centers, clinics, and medical and dental offices. For convenience, the term “hospital” is somet

49、imes used inthis recommended practice; in all instances, this term should be taken to encompass all other health care facilities.1.2 InclusionsThis standard covers minimum labeling, safety, performance, and testing requirements for EO sterilizers that areintended for general-purpose use in health care facilities and that have automatic controls. For purposes of thisstandard, a “general-purpose” EO sterilizer is defined as a chamber-type sterilization system that injects water vaporto adjust humidity during the cycle, generally employs excursions in pressure from a

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1