第5页 / 共26页
亲,该文档总共26页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、u d d ANSI/TIA/EIA-455-1lC-2002 Approved: June 6, 2002 TIA/EIA STANDARD FOTP-11 Vibration Test Procedure for Fiber Optic Components and Cables TIMEIA-455-1 1C 1 (Revision of TIA/EIA-455-1lB) JUNE 2002 TELECOMMUNICATIONS INDUSTRY ASSOCIATION Representing the telecommunications industry in association

2、 with the Electronic Industries Alliance Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NOTICE TIA/EIA Engineering Standards and Publications are designed to serve the public i

3、nterest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Publi

4、cations shall not in any respect preclude any member or nonmember of TIA/EIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than TIA/EIA members, whether

5、the standard is to be used either domestically or internationally. Standards and Publications are adopted by TIA/EIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, TIA/EIA does not assume any liability to any patent owner, nor does it assume any ob

6、ligation whatever to parties adopting the Standard or Publication. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practic

7、es and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No. 3-4638-RV3, formulated under the cognizance of the TIA FO-6.3 Subcommittee on Interconnecting Devices and Passive Components.) Published by TELECOMMUNICATIONS INDUSTRY ASSOCIATION 2002 Standa

8、rds and Technology Department 2500 Wilson Boulevard Arlington, VA 22201 U.S.A. PRICE: Please refer to current Catalog of EIA ELECTRONIC INDUSTRIES ALLIANCE STANDARDS and ENGINEERING PUBLICATIONS or call Global Engineering Documents, USA and Canada (1 -800-854-7 179) International (303-397-7956) All

9、rights reserved Printed in U.S.A. Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for

10、 ResaleNo reproduction or networking permitted without license from IHS-,-,-NOTICE OF DISCLAIMER AND LIMITATION OF LIABILITY The document to which this Notice is affixed has been prepared by one or more Engineering Committees of the Telecommunications Industry Association (“TIA”). TIA is not the aut

11、hor of the document contents, but publishes and claims copyright to the document pursuant to licenses and permission granted by the authors of the contents. TIA Engineering Committees are expected to conduct their affairs in accordance with the TIA Engineering Manual (“Manual”), the current and pred

12、ecessor versions of which are available at http:/www.tiaonline.orZr/standards/sfZr/engineering manual.ch. TIAS function is to administer the process, but not the content, of document preparation in accordance with the Manual and, when appropriate, the policies and procedures of the American National

13、 Standards Institute (“ANSI”). THE USE OR PRACTICE OF CONTENTS OF THIS DOCUMENT MAY INVOLVE THE USE OF INTELLECTUAL PROPERTY RIGHTS (“IPR), INCLUDING PENDING OR ISSUED PATENTS, OR COPYRIGHTS, OWNED BY ONE OR MORE PARTIES. TIA MAKES NO SEARCH OR INVESTIGATION FOR IPR. WHEN IPR CONSISTING OF PATENTS A

14、ND PUBLISHED PATENT APPLICATIONS ARE CLAIMED AND CALLED TO TIAS ATTENTION, A STATEMENT FROM THE HOLDER THEREOF IS REQUESTED, ALL IN ACCORDANCE WITH THE MANUAL. TIA TAKES NO POSITION WITH REFERENCE TO, AND DISCLAIMS ANY OBLIGATION TO INVESTIGATE OR INQUIRE INTO, THE SCOPE OR VALIDITY OF ANY CLAIMS OF

15、 IPR. ALL WARRANTIES, EXPRESS OR IMPLIED, ARE DISCLAIMED, INCLUDING WITHOUT LIMITATION, ANY AND ALL WARRANTIES CONCERNING THE ACCURACY OF THE CONTENTS, ITS FITNESS OR APPROPRIATENESS FORA PARTICULAR PURPOSE PARTYS INTELLECTUAL PROPERTY RIGHTS. TIA EXPRESSLY DISCLAIMS ANY AND ALL RESPONSIBILITIES FOR

16、 THE ACCURACY OF THE CONTENTS AND MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE CONTENTS COMPLIANCE WITH ANY APPLICABLE STATUTE, RULE OR REGULATION. OR USE, ITS MERCHANTABILITY AND ITS NON-INFRINGEMENT OF ANY THIRD TIA SHALL NOT BE LIABLE FOR ANY AND ALL DAMAGES, DIRECT OR INDIRECT, ARISING F

17、ROM OR RELATING TO ANY USE OF THE CONTENTS CONTAINED HEREIN, INCLUDING WITHOUT LIMITATION ANY AND ALL INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF BUSINESS, LOSS OF PROFITS, LITIGATION, OR THE LIKE), WHETHER BASED UPON BREACH OF CONTRACT, BREACH OF WARRANTY,

18、TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE FOREGOING NEGATION OF DAMAGES IS A FUNDAMENTAL ELEMENT OF THE USE OF THE CONTENTS HEREOF, AND THESE CONTENTS WOULD NOT BE PUBLISHED BY TIA WITHOUT SUCH LIMITATIONS. Copyright Telecomm

19、unications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TINEIA-455-1 1 C FOTP-11 Vibration test procedure for fi ber optic components and cables Contents Foreword III 1 Introduction 1 2 Applicable docume

20、nts 1 3 Apparatus 2 4 Sampling and specimens 5 Procedure 2 4 6 Calculations or interpretation of results 14 7 Documentation 14 8 Specification information 15 Annex A (informative) Comparison between FOTP-11 and IEC, ISO, AND ITU/T req u ire men ts 16 I Copyright Telecommunications Industry Associati

21、on Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TINEIA-455-1 1 C This page left blank. II Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking pe

22、rmitted without license from IHS-,-,-TINEIA-455-1 1 C FOTP-11 Vibration test procedure for fi ber optic components and cables Foreword (This foreword is informative and is not part of this standard.) From TIA Standards Proposal No. 4638-RV3, formulated under the cognizance of TIA FO-6.3, Subcommitte

23、e on Fiber Optic Interconnecting Devices, and FO- 6.7, Subcommittee on Fiber Optic Cable. This FOTP is part of the series of test procedures included within Recommended Standard TINEIA-455. NOTE - This FOTP was previously published in TINEIA-455-1 1 B as FOTP-11. . 111 Copyright Telecommunications I

24、ndustry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TINEIA-455-1 1 C This page left blank. iv Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction

25、 or networking permitted without license from IHS-,-,-TINEIA-455-1 1 C 1 Introduction 1.1 Intent The intent of this test is to determine the effects of vibration within the sinusoidal and random vibration environments that may be encountered during the life of the fiber optic component. The procedur

26、e is applicable to all types of fiber, cable or cable assemblies, and fiber optic devices including connectors, splices, passive branching devices (couplers), etc. 1.2 Failure Modes Typical indications of damage resulting from this test include, but are not limited to: a) Loss of optical continuity,

27、 and or degradation of optical transmission either during or at the end of the test b) Breakage or damage of fiber and/or other components c) For cables, damage to outer sheath such as cracks, splits, and kinks d) For connecting devices, inability to mate or unmate, broken parts or accessories, dama

28、ge to seals 2 Applicable documents The following documents form a part of this FOTP to the extent specified herein: E I AIT I A-455- B Standard Test Procedures for Fiber Optic Fibers, Cables, Transducers, Sensors, Connecting and Terminating Devices, and Other Fiber Optic Components FOTP-13 (TIA/EIA-

29、455-13A) Visual and Mechanical Inspection of Fiber Optic Components, Devices, and Assemblies FOTP-20 (TIA/EIA-455-20A) Measurement of Change in Optical Transmittance FOTP-32 (TIA/EIA-455-32A) Fiber Optic Circuit Discontinuities 1 Copyright Telecommunications Industry Association Provided by IHS unde

30、r license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TINEIA-455-1 1 C FOTP-53 (TIA/EIA-455-53A) Attenuation by Substitution Measurement for Multimode Graded-Index Optical Fibers or Fiber Assemblies Used in Long Length Communication Systems MI L-STD-134

31、4A IEC 61300-2-1 Test Methods for Electrical Connectors Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal) 3 Apparatus 3.1 Vibration The vibration system (consisting of the vibration machine together with its

32、auxiliary test equipment), shall be capable of generating either a sinusoidal or random excitation. Test equipment for random vibration shall produce random excitation that possesses a Gaussian (normal) amplitude distribution, except that the instantaneous acceleration magnitudes of the peak values

33、may be limited to a minimum of three times the rms three sigma (s) limits. 3.2 Other equipment Optical and other test equipment shall be available as required by FOTPs -13, - 20, -32, or -53 (or other). 4 Sampling and specimens 4.1 Samples When a vibration test sample consists of a fully terminated

34、device (e.g., connector and associated hardware) the cable length shall be specified by the Detail Specification. When the vibration test sample consists of a section of completed cable with or without cable connectors, the cable length shall be specified by the Detail Specification but shall be no

35、less than 21 meters (69 ft). Longer cable lengths of up to 100 meters (325 ft) may be required, depending upon optical measurements to be made. When the vibration test sample consists of an unterminated cable, the fibers of a multi-fibered cable may be 2 Copyright Telecommunications Industry Associa

36、tion Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TINEIA-455-1 1 C concatenated to provide longer test lengths where increased measurement sensitivity is desired. When the vibration test sample consists of a terminated cable

37、, the fibers in a multi-fibered cable may not be concatenated. 4.2 Specimen preparation Each test sample shall be prepared with optical fiber and other materials or processes, simulating field usage. When testing long cable lengths, the test cable may be placed on a reel with wraps sufficiently tigh

38、t to prevent movement. Cable ends shall be prepared for testing to allow attachment to appropriate attenuation equipment. If normal connector mating depends upon forces external to the connector, such forces and mounting arrangements shall be in the housing specified by the manufacturer or duplicate

39、d as closely as possible. If mating is achieved by normal locking means, then only normal locking means shall be used. Test samples shall be visually examined for chips, cracks, tears, splits, loose or missing parts, proper lubrication, proper assembly and mateability. Refer to FOTP-13. Unless other

40、wise specified, test samples shall be terminated with fiber of the type and configuration specified by the applicable Detail Specification, or if not in the Detail Specification, by that recommended by the manufacturer. 4.3 Method of mounting The test specimen shall be attached to a fixture capable

41、of transmitting the vibration conditions specified. The test fixture shall be designed such that resonant vibration(s) inherent in the fixture within the frequency range specified shall be minor. The magnitude of the applied vibration shall be monitored on the test fixture near the specimen mounting

42、 points. If the specimen is a cable, the magnitude of the vibration shall be determined as the maximum amplitude envelope. The test specimen shall be mounted rigidly to the test fixture and simulate as closely as possible normal mounting. A minimum of 20 cm (7.9 inches) of optical fiber, jacketed ca

43、ble, jumpers, etc. shall be unsupported on both ends of the specimen under test and attached, free of tension, to the vibrating surface. When the device under test is a cable, the length to be mounted shall be a minimum of 1 m (3.2 ft), unless longer lengths are specified by the Detail Specification

44、. Additionally for cable, the end of the cable shall be no closer than 10 meters (33 ft) from the test mount device. For specimens with attached brackets, one of the vibration-test directions shall be parallel to the mounting surface of the bracket. Vibration input shall be monitored on the mounting

45、 fixture in the proximity of the support points of the specimen. 3 Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TINEIA-455-1 1 C I II III IV V VI I VI I 5 Procedure 5.1 Measu

46、rements Tests and measurements before, during, and after vibration shall be as required in the Detail Specification. Test or inspection requirements may include, but are not limited to those given in 2. 5.2 Test conditions, general 5.2.1 Sinusoidal vibration conditions Test conditions I, II, III, IV

47、 and V are Sinusoidal Vibrations. Vibration conditions shall be in accordance with Table I and Figure 1, as applicable, unless otherwise specified in the Detail Specification. Table I - Vibration conditions G Level F req ue n cy Range (Hz) Test 1 Vibration Type Cond i tion Sinusoidal Sinusoidal Sinu

48、soidal Sinusoidal Sinusoidal Random Random 5.2.2 Random vi brations conditions 10 to 55 10 to 500 10 to 2,000 1 o to 2,000 5 to 500 - - - IO (Peak) 15 (Peak) 20 (Peak) 1 (Peak) Table II(RMS) , Table III(RMS) Test conditions VI and VI1 are random vibrations. Vibration conditions shall be in accordanc

49、e with Figures 2 and 3 and with Tables II and III. 4 Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TINEIA-455-1 1 C Table II - Values for test-condition VI1 Test Condition Letter A B C D

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1