ANSI TIA-607-C-1-2017 Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises (Addendum to TIA-607-C).pdf

上传人:李朗 文档编号:438640 上传时间:2018-11-14 格式:PDF 页数:14 大小:654.37KB
下载 相关 举报
ANSI TIA-607-C-1-2017 Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises (Addendum to TIA-607-C).pdf_第1页
第1页 / 共14页
ANSI TIA-607-C-1-2017 Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises (Addendum to TIA-607-C).pdf_第2页
第2页 / 共14页
ANSI TIA-607-C-1-2017 Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises (Addendum to TIA-607-C).pdf_第3页
第3页 / 共14页
ANSI TIA-607-C-1-2017 Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises (Addendum to TIA-607-C).pdf_第4页
第4页 / 共14页
ANSI TIA-607-C-1-2017 Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises (Addendum to TIA-607-C).pdf_第5页
第5页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、 TIA-607-C-1 (Addendum to TIA-607-C) January 2017Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises Addendum 1- Bonding in Multi-tenant Buildings ANSI/TIA-607-C-1-2017 APPROVED: DECEMBER 27, 2016 NOTICE TIA Engineering Standards and Publications are designed to serve t

2、he public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for their particular need. The existence of such St

3、andards and Publications shall not in any respect preclude any member or non-member of TIA from manufacturing or selling products not conforming to such Standards and Publications. Neither shall the existence of such Standards and Publications preclude their voluntary use by Non-TIA members, either

4、domestically or internationally. Standards and Publications are adopted by TIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, TIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the

5、Standard or Publication. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of r

6、egulatory limitations before its use. Any use of trademarks in this document are for information purposes and do not constitute an endorsement by TIA or this committee of the products or services of the company. (From Standards Proposal No. ANSI/TIA-PN-607-C-1, formulated under the cognizance of the

7、 TIA TR-42 Telecommunications Cabling Systems, TR-42.16 Subcommittee on Premises Telecommunications Bonding (b) there is no assurance that the Document will be approved by any Committee of TIA or any other body in its present or any other form; (c) the Document may be amended, modified or changed in

8、 the standards development or any editing process. The use or practice of contents of this Document may involve the use of intellectual property rights (“IPR”), including pending or issued patents, or copyrights, owned by one or more parties. TIA makes no search or investigation for IPR. When IPR co

9、nsisting of patents and published pending patent applications are claimed and called to TIAs attention, a statement from the holder thereof is requested, all in accordance with the Manual. TIA takes no position with reference to, and disclaims any obligation to investigate or inquire into, the scope

10、 or validity of any claims of IPR. TIA will neither be a party to discussions of any licensing terms or conditions, which are instead left to the parties involved, nor will TIA opine or judge whether proposed licensing terms or conditions are reasonable or non-discriminatory. TIA does not warrant or

11、 represent that procedures or practices suggested or provided in the Manual have been complied with as respects the Document or its contents. If the Document contains one or more Normative References to a document published by another organization (“other SSO”) engaged in the formulation, developmen

12、t or publication of standards (whether designated as a standard, specification, recommendation or otherwise), whether such reference consists of mandatory, alternate or optional elements (as defined in the TIA Procedures for American National Standards) then (i) TIA disclaims any duty or obligation

13、to search or investigate the records of any other SSO for IPR or letters of assurance relating to any such Normative Reference; (ii) TIAs policy of encouragement of voluntary disclosure (see TIA Procedures for American National Standards Annex C.1.2.3) of Essential Patent(s) and published pending pa

14、tent applications shall apply; and (iii) Information as to claims of IPR in the records or publications of the other SSO shall not constitute identification to TIA of a claim of Essential Patent(s) or published pending patent applications. TIA does not enforce or monitor compliance with the contents

15、 of the Document. TIA does not certify, inspect, test or otherwise investigate products, designs or services or any claims of compliance with the contents of the Document. ALL WARRANTIES, EXPRESS OR IMPLIED, ARE DISCLAIMED, INCLUDING WITHOUT LIMITATION, ANY AND ALL WARRANTIES CONCERNING THE ACCURACY

16、 OF THE CONTENTS, ITS FITNESS OR APPROPRIATENESS FOR A PARTICULAR PURPOSE OR USE, ITS MERCHANTABILITY AND ITS NONINFRINGEMENT OF ANY THIRD PARTYS INTELLECTUAL PROPERTY RIGHTS. TIA EXPRESSLY DISCLAIMS ANY AND ALL RESPONSIBILITIES FOR THE ACCURACY OF THE CONTENTS AND MAKES NO REPRESENTATIONS OR WARRAN

17、TIES REGARDING THE CONTENTS COMPLIANCE WITH ANY APPLICABLE STATUTE, RULE OR REGULATION, OR THE SAFETY OR HEALTH EFFECTS OF THE CONTENTS OR ANY PRODUCT OR SERVICE REFERRED TO IN THE DOCUMENT OR PRODUCED OR RENDERED TO COMPLY WITH THE CONTENTS. TIA SHALL NOT BE LIABLE FOR ANY AND ALL DAMAGES, DIRECT O

18、R INDIRECT, ARISING FROM OR RELATING TO ANY USE OF THE CONTENTS CONTAINED HEREIN, INCLUDING WITHOUT LIMITATION ANY AND ALL INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF BUSINESS, LOSS OF PROFITS, LITIGATION, OR THE LIKE), WHETHER BASED UPON BREACH OF CONTRACT,

19、 BREACH OF WARRANTY, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE FOREGOING NEGATION OF DAMAGES IS A FUNDAMENTAL ELEMENT OF THE USE OF THE CONTENTS HEREOF, AND THESE CONTENTS WOULD NOT BE PUBLISHED BY TIA WITHOUT SUCH LIMITATION

20、S. ANSI/TIA-607-C-1 i Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises Addendum 1 Bonding in Multi-tenant Buildings Table of Contents FOREWORD . ii 1 SCOPE 1 2 NORMATIVE REFERENCES . 1 3 DEFINITIONS, ACRONYMS AND ABBREVIATIONS, UNITS OF MEASURE 1 3.1 General 1 3.2 De

21、finitions 1 3.3 Acronyms and abbreviations 1 3.4 Units of measure 1 4 OVERVIEW OF THE TELECOMMUNICATIONS BONDING INFRASTRUCTURE 1 4.1 General 1 4.2 Common bonding infrastructure . 3 4.2.1 General . 3 4.2.2 Common bonding busbar (CBB) . 3 4.2.3 Telecommunications bonding conductor (TBC) . 3 4.2.4 Com

22、mon telecommunications bonding backbone (CTBB) 3 4.2.5 Secondary bonding busbar (SBB) . 3 4.2.6 Backbone bonding conductor (BBC) . 4 4.3 Tenant bonding infrastructure 4 4.3.1 General . 4 4.3.2 Bonding of the primary bonding busbar. 4 4.3.2.1 Common bonding infrastructure present 4 4.3.2.2 Common bon

23、ding infrastructure not present 4 List of Figures Figure 1 Illustrative example of a multi-tenant building 2 ANSI/TIA-607-C-1 ii FOREWORD (This foreword is not considered part of this Standard) This Addendum was developed by TIA Subcommittee TR-42.16. Approval of this Addendum This Addendum was appr

24、oved by TIA Subcommittee TR-42.16, TIA Engineering Committee TR-42, and the American National Standards Institute (ANSI). ANSI/TIA reviews standards every 5 years. At that time, standards are reaffirmed, withdrawn, or revised according to the submitted updates. Updates to be included in the next rev

25、ision should be sent to the committee chair or to ANSI/TIA. Documents superseded None. Purpose The purpose of this Addendum is to specify requirements for a generic telecommunications bonding infrastructure in multi-tenant buildings Introduction ANSI/TIA-607-C describes bonding and grounding for bui

26、ldings which typically serve a single tenant. This has led to confusion as to how the requirements of the Standard are to be imple-mented in multi-tenant buildings. This Addendum describes a common bonding infrastructure intended to provide bonding for equipment providing shared services and for the

27、 bonding infra-structures in tenant spaces. It also describes the connection of the tenant bonding infrastruc-tures to the common bonding infrastructure, if present, or to the equipment (power) ground when a common bonding infrastructure is not present. ANSI/TIA-607-C-1 1 1 SCOPE This Addendum speci

28、fies requirements for a generic telecommunications bonding infrastructure in multi-tenant buildings. This Standard may also be used as a guide for the renovation or retro-fit of existing systems. 2 NORMATIVE REFERENCES None. 3 DEFINITIONS, ACRONYMS AND ABBREVIATIONS, UNITS OF MEASURE 3.1 General For

29、 the purposes of this Addendum, the definitions, acronyms, abbreviations and units of meas-ure of ANSI/TIA-607-C and the following apply. 3.2 Definitions common bonding busbar: A bonding busbar serving one or more common telecommunica-tions bonding backbones in a multi-tenant building. common distri

30、butor room: A distributor room that services tenants in a multi-tenant building. common telecommunications bonding backbone: A conductor that interconnects the com-mon bonding busbar of a multi-tenant building to the secondary bonding busbars for shared services and the primary bonding busbars in te

31、nant spaces. 3.3 Acronyms and abbreviations CBB common bonding busbar CTBB common telecommunications bonding backbone 3.4 Units of measure None 4 OVERVIEW OF THE TELECOMMUNICATIONS BONDING INFRASTRUCTURE 4.1 General The telecommunications bonding infrastructure in a multi-tenant building consists of

32、 the com-mon bonding infrastructure and the tenant bonding infrastructures. Figure 1 shows the relation-ship between the two. ANSI/TIA-607-C-1 2 C o m m o n e q u i p m e n tE q u i p m e n tC o m m o n e q u i p m e n tS B BC o m m o n d i s t r i b u t o rr o o mT e n a n t s p a c eT e l e c o m

33、m u n i c a t i o n s e n t r a n c e f a c i l i t y ( T E F )E l e c t r i c a l e n t r a n c e f a c i l i t yP a t h w a y sB a c k b o n e b o n d i n g c o n d u c t o r ( B B C )E q u i p m e n tE q u i p m e n tE q u i p m e n tP r i m a r y b o n d i n g b u s b a r ( P B B )T e n a n t s

34、p a c eT e n a n t s p a c eT e n a n t s p a c eC o m m o n b o n d i n g b u s b a r ( C B B )T e l e c o m m u n i c a t i o n s b o n d i n g c o n d u c t o r ( T B C )G r o u n d i n g E l e c t r o d e C o n d u c t o rG r o u n d i n g e l e c t r o d e s y s t e mC o m m o n t e l e c o m m

35、 u n i c a t i o n s b o n d i n g b a c k b o n e ( C T B B )B u s b a rS e r v i c e e q u i p m e n tP a n e l b o a r dB u i l d i n g s p a c e sB o n d i n g c o n d u c t o r a s l a b e l e dL E G E N DS t r u c t u r a l m e t a lP B BP B BP B BFigure 1 Illustrative example of a multi-tenan

36、t building ANSI/TIA-607-C-1 3 4.2 Common bonding infrastructure 4.2.1 General The common bonding infrastructure in a multi-tenant building provides potential equalization for shared services (e.g., building automations systems, intelligent building systems, distributed an-tenna systems). In addition

37、, it may provide the bonding infrastructure to which the tenant bond-ing infrastructures are connected. If common services are present in a building a common bonding infrastructure as described in this Addendum shall be provided. If no common services are present a common bonding infra-structure sho

38、uld be provided. NOTE Common equipment is typically housed in a common distributor room. If present, the common bonding infrastructure includes the following major components: a) common bonding busbar (CBB); b) telecommunications bonding conductor (TBC); and c) common telecommunications bonding back

39、bone (CTBB). and may also include the following: d) secondary bonding busbar (SBB); and, e) backbone bonding conductor (BBC). These telecommunications bonding components are intended to work with a buildings tele-communications pathways and spaces, installed cabling, and administration system. 4.2.2

40、 Common bonding busbar (CBB) The CBB serves as the dedicated extension of the building grounding electrode system for the telecommunications infrastructure. The CBB also serves as the central attachment point for the CTBB(s) and equipment. As such, it serves as the primary bonding busbar (PBB) for t

41、he entire multitenant building and shall meet the requirements for a PBB in ANSI/TIA-607-C. 4.2.3 Telecommunications bonding conductor (TBC) The TBC bonds the CBB to the service equipment (power) ground. See ANSI/TIA-607-C. 4.2.4 Common telecommunications bonding backbone (CTBB) The CTBB is a conduc

42、tor that interconnects all SBBs with the CBB. The intended function of a CTBB is to reduce or equalize potential differences for equipment providing shared services. In addition, the CTBB interconnects all primary bonding busbars (PBBs) in tenant spaces to the CBB. The CTBB shall meet the requiremen

43、ts for a TBB in ANSI/TIA-607-C. 4.2.5 Secondary bonding busbar (SBB) The SBB is the bonding connection point for shared telecommunications systems and equip-ment in the area served by a common distributor room. The SBB shall meet the requirements in ANSI/TIA-607-C. ANSI/TIA-607-C-1 4 4.2.6 Backbone

44、bonding conductor (BBC) When there are multiple CTTBs, the BBC is employed to interconnect them through the associ-ated busbars, either on the same floor in a multi-story building or in the same general area of a single story building. BBCs shall meet the requirements of ANSI/TIA-607-C. 4.3 Tenant b

45、onding infrastructure 4.3.1 General The tenant bonding infrastructure shall meet the requirements of ANSI/TIA-607-C with the ex-ception described in 4.3.2 4.3.2 Bonding of the primary bonding busbar The PBB of a building serving a single tenant is bonded to the service equipment (power) ground using

46、 a TBC. In a multi-tenant building the bonding of the PBB depends upon whether a common bonding infrastructure is present. 4.3.2.1 Common bonding infrastructure present If a common bonding infrastructure is present the tenant PBBs shall be bonded to the CTBB. This bonding shall meet the requirements

47、 for bonding of SBBs to the TBB in ANSI/TIA-607-C. 4.3.2.2 Common bonding infrastructure not present If a common bonding infrastructure is not present each tenant PBB shall be bonded to the equipment (power) ground of the tenants main electrical panel. The conductor used to provide this bond shall m

48、eet the requirements for a TBC in ANSI/TIA-607-C. THE TELECOMMUNICATIONS INDUSTRY ASSOCIATION TIA represents the global information and communications technology (ICT) industry through standards development, advocacy, tradeshows, business opportunities, market intelligence and world-wide environment

49、al regulatory analysis. Since 1924, TIA has been enhancing the business environment for broadband, wireless, information technology, cable, satellite, and unified communications. TIA members products and services empower communications in every industry and market, including healthcare, education, security, public safety, transportation, government, the utilities. TIA is accredited by the American National Standards Institute (ANSI).

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1