ANSI UL 1037-2016 UL Standard for Safety Antitheft Alarms and Devices (Sixth Edition Reprint with revisions through and including September 15 2017).pdf

上传人:progressking105 文档编号:438785 上传时间:2018-11-14 格式:PDF 页数:101 大小:986.22KB
下载 相关 举报
ANSI UL 1037-2016 UL Standard for Safety Antitheft Alarms and Devices (Sixth Edition Reprint with revisions through and including September 15 2017).pdf_第1页
第1页 / 共101页
ANSI UL 1037-2016 UL Standard for Safety Antitheft Alarms and Devices (Sixth Edition Reprint with revisions through and including September 15 2017).pdf_第2页
第2页 / 共101页
ANSI UL 1037-2016 UL Standard for Safety Antitheft Alarms and Devices (Sixth Edition Reprint with revisions through and including September 15 2017).pdf_第3页
第3页 / 共101页
ANSI UL 1037-2016 UL Standard for Safety Antitheft Alarms and Devices (Sixth Edition Reprint with revisions through and including September 15 2017).pdf_第4页
第4页 / 共101页
ANSI UL 1037-2016 UL Standard for Safety Antitheft Alarms and Devices (Sixth Edition Reprint with revisions through and including September 15 2017).pdf_第5页
第5页 / 共101页
亲,该文档总共101页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1037 Antitheft Alarms and Devices STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUT

2、HORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Antitheft Alarms and Devices, UL 1037 Sixth Edition, Dated September 9, 2016 Summary of Topics Revisions are being issued for ANSI/UL 1037 to clarify requirements for Residential Security Container

3、s. The new/revised requirements are substantially in accordance with Proposal(s) on this subject dated May 19, 2017. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. All rights reserved. No part of this publication

4、 may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited

5、 to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use

6、this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Saf

7、ety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. S

8、EPTEMBER 15, 2017 UL 1037 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 15, 2017 UL 1037 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEM

9、BER 9, 2016 (Title Page Reprinted: September 15, 2017) 1 UL 1037 Standard for Antitheft Alarms and Devices First Edition July, 1974 Second Edition June, 1981 Third Edition December, 1988 Fourth Edition July, 1994 Fifth Edition February, 1999 Sixth Edition September 9, 2016 This ANSI/UL Standard for

10、Safety consists of the Sixth Edition including revisions through September 15, 2017. The most recent designation of ANSI/UL 1037 as an American National Standard (ANSI) occurred on September 15, 2017. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and Title Page. Com

11、ments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor ele

12、ctronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2017 UNDERWRITERS LABORATORIES INC. ANSI/UL 1037-2017UL COPYRIGHTED MATERIAL NOT AUTHORIZED

13、 FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 9, 2016 ANTITHEFT ALARMS AND DEVICES - UL 1037 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .7 2 General 7

14、2.1 Components .7 2.2 Units of measurement .8 2.3 Undated references .8 2.4 Terminology .8 3 Glossary .8 4 Installation and Operating Instructions .9 CONSTRUCTION ALL PRODUCTS ASSEMBLY 5 General .10 5.1 Product assembly .10 5.2 Electrical protection 10 6 Protection of Service Personnel .15 7 Enclosu

15、res 15 7.1 General 15 7.2 Doors and covers .17 7.3 Enclosure openings 17 7.4 Screens and expanded metal .19 7.5 Cast metal 19 7.6 Sheet metal 20 7.7 Product enclosure mounting 23 7.8 Polymeric materials 23 8 Electric Shock .23 9 Corrosion Protection .24 FIELD WIRING CONNECTIONS 10 General 24 11 Cord

16、 Connected Products .25 12 Permanently Connected Products .26 12.1 General .26 12.2 Field wiring terminals .27 12.3 Field wiring leads .29 12.4 Polarity identication 30 13 Grounding .30 INTERNAL WIRING 14 General 31 15 Wiring Methods .32 16 Separation of Circuits .33 17 Bonding for Grounding 34 SEPT

17、EMBER 9, 2016 ANTITHEFT ALARMS AND DEVICES - UL 1037 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL COMPONENTS, ELECTRICAL 18 General 37 18.1 Mounting of components 37 18.2 Insulating materials .38 18.3 Fuseholders .39 18.4 Current-carryin

18、g parts .39 18.5 Power on indicator .39 19 Overcurrent Protection 39 20 Semiconductors 39 21 Switches .39 22 Transformers and Coils 40 SPACINGS 23 General 40 24 Components .43 PERFORMANCE ALL PRODUCTS 25 General 43 25.1 Test units and data .43 25.2 Test samples and miscellaneous data 44 25.3 Test vo

19、ltages 44 26 Normal Operation Test 44 27 Input Test 45 28 Output Measurement Test .45 29 Power-Limited Circuits .46 29.1 General .46 29.2 Maximum voltage 48 29.3 Maximum current .48 29.4 VA max (Not inherently limited circuits only) .49 30 Electrical Supervision Test .49 31 Undervoltage Operation Te

20、st .49 32 Overvoltage Operation Test 50 33 Variable Ambient Test .50 34 Humidity Test 50 35 Electric Shock Current Test 50 36 Leakage Current Tests for Cord-Connected Products .54 37 Overload Test 57 37.1 General .57 37.2 Separately energized circuits 57 38 Endurance Test 58 38.1 General .58 38.2 Se

21、parately energized circuits 58 39 Jarring Test 58 40 Road Shock and Vibration Tests 59 41 Dielectric Voltage-Withstand Test .60 42 Temperature Test .61 43 Abnormal Operation Test 64 44 Electrical Transient Tests 65 44.1 General .65 44.2 Supply line transients .65 SEPTEMBER 9, 2016 ANTITHEFT ALARMS A

22、ND DEVICES - UL 1037 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 44.3 Internally induced transients .65 44.4 Input/output circuit transients 66 45 AC Induction Test .67 46 Polymeric Materials Test .68 47 Battery Replacement Test .68 48

23、Drop Test 68 49 Strain Relief Test .68 49.1 Supply cord .68 49.2 Field-wiring leads .69 50 Ignition Through Bottom-Panel Openings Tests .69 50.1 General .69 50.2 Hot, aming oil .69 51 Mechanical Strength Tests for Enclosures .70 52 Special Terminal Assemblies Tests .70 52.1 General .70 52.2 Disconne

24、ction and reconnection .71 52.3 Mechanical secureness .71 52.4 Flexing test 71 52.5 Millivolt drop test .71 52.6 Temperature test .72 53 Attack Test .72 54 Residential Security Container 72 54.1 Locks .72 54.2 Attack test Attack level I .73 54.3 Attack test Attack level II 74 54.4 Attack test Attack

25、 level III 74 MANUFACTURING AND PRODUCTION TESTS ALL HIGH-VOLTAGE PRODUCTS 55 General 75 56 Production Line Dielectric Voltage-Withstand Test 75 57 Production Line Grounding Continuity Test for High-Voltage, Cord-Connected Products .76 MARKINGS ALL PRODUCTS 58 Details .76 59 Marking Permanency Tests

26、 79 OUTDOOR USE EQUIPMENT ASSEMBLY 60 General 79 61 Construction .79 61.1 General .79 61.2 Corrosion protection 80 62 Field-Wiring Connections 82 63 Internal Wiring 82 64 Components, Electrical Insulating Material .84 SEPTEMBER 9, 2016 ANTITHEFT ALARMS AND DEVICES - UL 1037 5UL COPYRIGHTED MATERIAL

27、NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL PERFORMANCE 65 Rain Test 84 66 Dust Test 87 67 Variable Ambient Test .87 68 Metallic Coating Thickness Test 87 69 Corrosion Tests 89 69.1 General .89 69.2 Salt spray (fog) 89 69.3 Moist hydrogen sulde (H 2 S) air mixt

28、ure 90 69.4 Moist carbon dioxide (CO 2 )-sulfur dioxide (SO 2 )-air mixture .90 70 Ultraviolet Light and Water Exposure Test .90 71 Accelerated Aging Tests For Gaskets, Sealing Compounds, and Adhesives .91 MARKINGS 72 Details .92 ACCESSORY EQUIPMENT 73 General 93 74 Construction .93 75 Performance (

29、Installation) Test .94 76 Markings .94 APPENDIX A Standards for ComponentsA1 SEPTEMBER 9, 2016 ANTITHEFT ALARMS AND DEVICES - UL 1037 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements apply to the c

30、onstruction, performance, and operation of equipment intended to provide antitheft protection. 1.2 An antitheft alarm is intended to give both audible and visible signals or only an audible signal if theft of protected property is attempted. 1.3 An antitheft device is intended to protect property by

31、 signicantly limiting the mobility or portability of the property. 1.4 Equipment intended to provide a degree of re resistance is additionally covered under the requirements of the Standard for Tests for Fire Resistance of Record Protection Equipment, UL 72. 2 General 2.1 Components 2.1.1 Except as

32、indicated in 2.1.2, a component of a product covered by this standard shall comply with the requirements for that component. See Appendix A for a list of standards covering components generally used in the products covered by this standard. 2.1.2 A component is not required to comply with a specic r

33、equirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.1.3 A component shall be used in accordance with its rating established for the intended conditi

34、ons of use. 2.1.4 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under those specic conditions.

35、SEPTEMBER 9, 2016 ANTITHEFT ALARMS AND DEVICES - UL 1037 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2.2 Units of measurement 2.2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approxim

36、ate information. 2.2.2 Unless otherwise indicated, all voltage and current values mentioned in this standard are root-mean-square (rms). 2.3 Undated references 2.3.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the la

37、test edition of that code or standard. 2.4 Terminology 2.4.1 The term product as used in this standard refers to all types of antitheft alarms and devices. 3 Glossary 3.1 For the purpose of this standard the following denitions apply. 3.2 CIRCUITS, ELECTRICAL a) High-Voltage (Class 1) A circuit invo

38、lving a potential of not more than 600 volts and having circuit characteristics in excess of those of a low-voltage power-limited circuit. b) Low-Voltage A circuit involving a potential of not more than 30 volts alternating current (AC) rms, 42.4 volts peak or direct current (DC). c) Power Limited A

39、 circuit whose output is limited as specied in Power-Limited Circuits, Section 29. d) Class2Acircuit in which the voltage and power limitations are in accordance with the requirements of Table 29.1 for AC circuits and Table 29.2 for DC circuits. e) Class3Acircuit in which the voltage and power limit

40、ations are in accordance with the requirements of Table 29.1 for AC circuits and Table 29.2 for DC circuits. 3.3 CORD-CONNECTED UNIT A unit intended for connection to the power source by means of a supply cord. Such a unit is intended to be moved for reasons of interchange or realignment of the unit

41、s of a system. 3.4 LINE VOLTAGE The voltage at any eld connected source of supply, nominally 50 60 hertz (Hz), and either 115, 208, or 230 volts. 3.5 NORMAL STANDBY CONDITION The ready-to-operate condition of the product existing prior to its being tripped or operated by theft attempt. SEPTEMBER 9,

42、2016 ANTITHEFT ALARMS AND DEVICES - UL 1037 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 3.6 PERMANENT SECURITY CONTAINER A security container that weighs more than 750 pounds or is to be xed to a surface that is not intended to be moved

43、. 3.7 PORTABLE SECURITY CONTAINER A security container that weighs less than 750 pounds. 3.8 PRIMARY BATTERY A battery that by construction is not intended to be recharged. 3.9 RESIDENTIAL SECURITY CONTAINER A container intended to be used in a residence to provide moderate protection to items (such

44、 as guns, jewelry and other valuables) against burglary or theft. 3.10 SAFETY CIRCUIT Any primary or secondary circuit that is relied upon to reduce the risk of re, electric shock, or unintentional contact with moving parts that may cause injury to persons (for example, an interlock circuit). 3.11 S

45、ECONDARY BATTERY A battery that by construction is intended to be recharged. 4 Installation and Operating Instructions 4.1 A copy of: a) The installation and operating instructions intended to accompany each product or component as produced, b) The related schematic wiring diagrams, and c) The insta

46、llation drawings is to be furnished with the sample submitted for investigation to be used as a guide in the examination and test of the product or component. For this purpose, a nal printed edition is not required. 4.2 The instructions and drawings shall include at least the following: a) Typical i

47、nstallation drawing layouts and complete representative installation wiring diagrams for the product indicating recommended locations and wiring methods that shall be in accordance with the National Electrical Code, ANSI/NFPA 70. Locations where installations are not recommended shall also be includ

48、ed. b) Concise description of the operation, testing, and maintenance procedures for the product(s), and recommended testing frequency (that shall be at least once a year). c) Identication of replacement parts, such as lamps or batteries, by a part number, manufacturers model number, or other means

49、that have been determined to be equivalent. d) A description of the conditions that might be expected to result in false alarms or impaired operation of the product. e) A description of any features provided to reduce the risk of re, electric shock, or injury to persons and a warning against bypassing such features. SEPTEMBER 15, 2017 ANTITHEFT ALARMS AND DEVICES - UL 1037 9UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1