ANSI UL 1042-2009 UL Standard for Safety Electric Baseboard Heating Equipment (Fifth Edition Reprint with Revisions Through and Including December 14 2016)《电护壁板加热设备标准》.pdf

上传人:progressking105 文档编号:438788 上传时间:2018-11-14 格式:PDF 页数:117 大小:1.14MB
下载 相关 举报
ANSI UL 1042-2009 UL Standard for Safety Electric Baseboard Heating Equipment (Fifth Edition Reprint with Revisions Through and Including December 14 2016)《电护壁板加热设备标准》.pdf_第1页
第1页 / 共117页
ANSI UL 1042-2009 UL Standard for Safety Electric Baseboard Heating Equipment (Fifth Edition Reprint with Revisions Through and Including December 14 2016)《电护壁板加热设备标准》.pdf_第2页
第2页 / 共117页
ANSI UL 1042-2009 UL Standard for Safety Electric Baseboard Heating Equipment (Fifth Edition Reprint with Revisions Through and Including December 14 2016)《电护壁板加热设备标准》.pdf_第3页
第3页 / 共117页
ANSI UL 1042-2009 UL Standard for Safety Electric Baseboard Heating Equipment (Fifth Edition Reprint with Revisions Through and Including December 14 2016)《电护壁板加热设备标准》.pdf_第4页
第4页 / 共117页
ANSI UL 1042-2009 UL Standard for Safety Electric Baseboard Heating Equipment (Fifth Edition Reprint with Revisions Through and Including December 14 2016)《电护壁板加热设备标准》.pdf_第5页
第5页 / 共117页
亲,该文档总共117页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1042 Electric Baseboard Heating Equipment STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL

2、 NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Electric Baseboard Heating Equipment, UL 1042 Fifth Edition, Dated August 31, 2009 Summary of Topics These revisions of ANSI/UL 1042 include a Clarication of Requirements for Heating Elemen

3、ts Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. The new and revised requirements are substantially in accordance with Proposal(s) on this subject dated June 10, 2016 and October 28, 2016. In the revisions dated

4、 December 14, 2016, pages 34A or 2) The heater enclosure is intended to be connected to other heater enclosures to form a system. Exception: A heater intended for ceiling mounting or suspended mounting or marked Do Not Install Less Than 6 Feet From Floor is not considered to be a baseboard heater ev

5、en if it meets the specications in (1) or (2) above. b) Portable A portable heater is identied as a baseboard heater if, excluding projections of guard or feet, it is less than 5 in (130 mm) in depth and if the ratio of its overall length to its height without the handle is as follows: AUGUST 31, 20

6、09 ELECTRIC BASEBOARD HEATING EQUIPMENT - UL 1042 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Maximum height of heater, feet (mm) Ratio of length to height 2 (610) More than 2 to 1 Over 2 (610) More than 3 to 1 Exception: A portable rad

7、iant heater which has a visible glowing heating element and which is not sold or recommended for use as a baseboard heater may be excluded as a baseboard heater even if it meets the dimensional specications in (b) above. Such a heater may be judged under the requirements for movable air heaters in t

8、he Standard for Movable and Wall- or Ceiling-Hung Electric Room Heaters, UL 1278. For this determination, a radiant heater is one in which the visible portion of the heating element attains a temperature of at least 650C (1200F) under normal conditions of operation. 2 Units of Measurement 2.1 Values

9、 stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 2A Glossary 2A.1 For the purposes of this standard the following denitions apply. 2A.2 APPLIANCE COUPLER A single-outlet, female contact device for attachment to a exible cord as part o

10、f a detachable power-supply cord to be connected to an appliance inlet (motor attachment plug). 2A.3 APPLIANCE INLET (Motor Attachment Plug) A male contact device mounted on an end product appliance to provide an integral blade conguration for the connection of an appliance coupler or cord connector

11、. 2A.4 APPLIANCE (FLATIRON) PLUG An appliance coupler type of device having a cord guard and a slot conguration specied for use with heating or cooking appliances. 2A.5 COMPONENT A device or fabricated part of the appliance covered by the scope of a safety standard dedicated to the purpose. When inc

12、orporated in an appliance, equipment otherwise typically eld installed (e.g. luminaire) is considered to be a component. Unless otherwise specied, materials that compose a device or fabricated part, such as thermoplastic or copper, are not considered components. 2A.6 CONTROL CIRCUIT A circuit that c

13、arries the electric signals directing the operation of a controller which, in turn, governs power delivered to a motor or other load. A control circuit does not carry the main power current. 2A.7 CORD CONNECTOR A female contact device wired on exible cord for use as an extension from an outlet to ma

14、ke a detachable electrical connection to an attachment plug or, as an appliance coupler, to an equipment inlet. 2A.8 TEMPERATURE CONTROLS Devices that respond with a change in temperature (thermostatic devices) may be one of the following types: a) Regulating Functions only to regulate the temperatu

15、re of the heater under intended conditions of use, and whose malfunction would not result in a risk of re. b) Limiting Functions only under conditions that produce abnormal temperatures. The malfunction of such a device will result in a risk of re. DECEMBER 14, 2016 ELECTRIC BASEBOARD HEATING EQUIPM

16、ENT - UL 1042 6AUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL c) Auxiliary Thermostatic device other than of the regulating or limiting type. d) Operating Control A control intended to start or regulate the heater during normal operation.

17、An example would be a temperature-regulating control. An operating control could provide Type 1 or Type 2 action. (See denitions 2A.9 2A.12). e) Protective Control A control intended to reduce the risk of electric shock, re, or injury to persons during abnormal operation of the heater. An example wo

18、uld be a temperature limiting control. A protective control always provides Type 2 action. (See denitions 2A.9 2A.12). 2A.9 TYPE 1 ACTION Automatic action for which the manufacturing deviation and the drift of its operating value, operating time, or operating sequence have not been declared and test

19、ed to the Standard for Automatic Electrical Controls Part 1: General Requirements, UL 60730-1. 2A.10 TYPE 2 ACTION Automatic action for which the manufacturing deviation and the drift of its operating value, operating time, or operating sequence have been declared and tested to the Standard for Auto

20、matic Electrical Controls Part 1: General Requirements, UL 60730-1. 2A.11 TYPE 2.H ACTION So designed that the contacts cannot be prevented from opening and which may automatically reset to the closed position if the reset means is held in the reset position. The control shall not reset automaticall

21、y at any temperature above -35 C. 2A.12 TYPE 2.J ACTION So designed that the contacts cannot be prevented from opening, and the control is not permitted to function as an automatic reset device if the reset means is held in the reset position. The control shall not reset automatically at any tempera

22、ture above -35 C. 3 Components 3.1 General 3.1.1 A component of a product covered by this standard shall: a) Comply with the requirements for that component as indicated in 3.2 - 3.10; b) Be used in accordance with its rating(s) established for the intended conditions of use; c) Be used within its e

23、stablished use limitations or conditions of acceptability; d) Additionally comply with the applicable requirements of this end product standard; and Exception No. 1: A component of a product covered by this standard is not required to comply with a specic component requirement that: a) Involves a feature or characteristic not required in the application of the component in the product; DECEMBER 14, 2016 ELECTRIC BASEBOARD HEATING EQUIPMENT - UL 1042 6B

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1