ANSI UL 1489-2016 UL Standard for Safety Fire Tests of Fire Resistant Pipe Protection Systems Carrying Combustible Liquids (First Edition).pdf

上传人:visitstep340 文档编号:438905 上传时间:2018-11-14 格式:PDF 页数:23 大小:714.21KB
下载 相关 举报
ANSI UL 1489-2016 UL Standard for Safety Fire Tests of Fire Resistant Pipe Protection Systems Carrying Combustible Liquids (First Edition).pdf_第1页
第1页 / 共23页
ANSI UL 1489-2016 UL Standard for Safety Fire Tests of Fire Resistant Pipe Protection Systems Carrying Combustible Liquids (First Edition).pdf_第2页
第2页 / 共23页
ANSI UL 1489-2016 UL Standard for Safety Fire Tests of Fire Resistant Pipe Protection Systems Carrying Combustible Liquids (First Edition).pdf_第3页
第3页 / 共23页
ANSI UL 1489-2016 UL Standard for Safety Fire Tests of Fire Resistant Pipe Protection Systems Carrying Combustible Liquids (First Edition).pdf_第4页
第4页 / 共23页
ANSI UL 1489-2016 UL Standard for Safety Fire Tests of Fire Resistant Pipe Protection Systems Carrying Combustible Liquids (First Edition).pdf_第5页
第5页 / 共23页
亲,该文档总共23页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1489 Fire Tests of Fire Resistant Pipe Protection Systems Carrying Combustible Liquids STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITH

2、OUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Fire Tests of Fire Resistant Pipe Protection Systems Carrying Combustible Liquids,UL 1489 First Edition, Dated September 22, 2016 Summary of Top

3、ics This First Edition of UL 1489 covers products such as, but not limited to, sleeve, wrap or spray-on type re protection systems applied over or on to rigid piping networks typically consisting of short sections of thick wall pipe connected with threaded or welded ttings that are assembled on site

4、. It also describes a standard test method to develop the data necessary for evaluating re resistive pipe protection systems for specic applications. The new requirements are substantially in accordance with Proposal(s) on this subject dated July 15, 2016. All rights reserved. No part of this public

5、ation may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not li

6、mited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to

7、 use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards fo

8、r Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer syst

9、em. SEPTEMBER 22, 2016 UL 1489 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 22, 2016 UL 1489 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL S

10、EPTEMBER 22, 2016 1 UL 1489 Standard for Fire Tests of Fire Resistant Pipe Protection Systems Carrying Combustible Liquids First Edition September 22, 2016 This ANSI/UL Standard for Safety consists of the First Edition. The most recent designation of ANSI/UL 1489 as an American National Standard (AN

11、SI) occurred on September 22, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Prop

12、osal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those S

13、tandards shall remain the sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 1489-2016UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 22, 2016 UL 1489 2 No Text on This PageUL COPYRIGHTED MATER

14、IAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 Units of Measurement .5 3 Undated References 5 4 Glossary .6 PERFORMANCE 5 Fire Exposure Test 6 5.1 Test sample .6 5.2 Conditioning .7 5.3 Protection of assembly and sample .7 5.

15、4 Furnace temperature control and measurement 8 5.5 Furnace thermocouple preparation 9 5.6 Sample temperature measurement .9 5.7 Differential pressure measurements .11 5.8 Duration of test 12 6 Hose Stream Test .12 7 Leakage Test 13 CONDITIONS OF ACCEPTANCE 8 General .13 8.1 Fire exposure .13 8.2 Th

16、ermal protection .13 8.3 Correction re exposure test 13 8.4 Leakage 14 REPORT 9 Results .14 10 Application of Results .15 11 Other Reference Material 15 APPENDIX A SEPTEMBER 22, 2016 UL 1489 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL I

17、NTRODUCTION 1 Scope 1.1 These requirements cover the investigation of products such as, but not limited to, sleeve, wrap or spray-on type re protection systems of various materials and construction intended to protect rigid piping networks containing combustible liquids from a re exposure, such as d

18、iesel fuel or heating oil, that are routed in buildings between the supply tank and utilizing equipment. 1.2 Under these requirements, samples of re resistive pipe protection systems are exposed to a re exposure for a duration based on a desired hourly rating, and then to an application of a water h

19、ose stream. The re resistive pipe protection system will also be evaluated for its ability to resist leakage of liquid from the pipe. The following measurements and determinations are made during the re exposure and water hose stream tests: a) Measurement of temperature on the exposed surface of the

20、 outermost pipe of the test specimen. b) Determination of the integrity of the re resistive pipe protection systems during the re exposure and water hose stream test. c) Determination of tightness and leakage resistance of the pipe after the re exposure and water hose stream test. 1.3 The re exposur

21、e and water hose stream tests may not be representative of all re conditions. Conditions may vary with changes in the amount, nature, and distribution of re loading, ventilation, compartment size and conguration, and heat conducting and dissipating characteristics of the compartment in which the re

22、resistive pipe protection system is installed. These requirements provide a relative measure of re performance of comparable assemblies under these specied re exposure conditions. Any variation from the construction or operating condition tested, such as size, method of assembly, and materials, may

23、substantially change the performance characteristics of the system. 1.4 The classications for building construction and materials are intended to register performance during the period of re exposure and are not intended to be interpreted as having determined their acceptability for use after re exp

24、osure. 1.5 This standard does not evaluate the fuel pipe construction in terms of components or assembly techniques. This is a test to evaluate the re protection element of the assembly. It is assumed that fuel pipe requirements (e.g. sealing compounds/lubricants etc.) that are established by other

25、codes and standards will be satised outside of this test method. 1.6 These requirements do not cover: a) Accumulation of data as to performance of re resistive pipe protection systems constructed with components or sizes other than those tested. b) Evaluation of the contribution of the re resistive

26、pipe protection systems generation of smoke, toxic gases, or other products of combustion. c) Measurement of ame spread over the surface of the tested elements. SEPTEMBER 22, 2016 UL 1489 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL d) E

27、valuation of the restop system in openings penetrated by the re resistive pipe protection systems. Firestop systems for re resistive pipe protection systems shall be evaluated to the Standard for Fire Tests of Penetration Firestops, UL 1479. e) Evaluation of the impact of re and elevated temperature

28、s on the pipe and associated ttings and other construction features. f) Pipe systems that carry fuels with a boiling point below room temperature. g) The compatibility, including the potential for corrosion, between the protection system and the pipe material. 1.7 The results obtained by use of this

29、 test method are intended to develop data that will assist designers, authorities having jurisdiction, end-users, installers and others in determining the acceptability, with reference to re resistive pipe protection systems for use with specic pipe applications. 1.8 Tests for burning characteristic

30、s of building materials, based on rate of ame spread and the density of smoke developed when exposed to a standard re, can be found in the requirements for surface burning characteristics of building materials in the Standard for Test for Surface Burning Characteristics of Building Materials, UL 723

31、. 1.9 Tests for re resistance of restop systems which penetrate walls, oors and other membranes can be found in the requirements for the Standard for Fire Tests of Penetration Firestops, UL 1479. 1.10 Application of these test results to predict re resistance of pipe protection systems in actual ins

32、tallations requires careful evaluation of the pipe and re resistive pipe protection system materials under normal operating conditions. 2 Units of Measurement 2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 3 Undated Refere

33、nces 3.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. SEPTEMBER 22, 2016 UL 1489 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PE

34、RMISSION FROM UL 4 Glossary 4.1 For the purpose of this Standard, the following denitions apply. 4.2 COMBUSTIBLE LIQUID A liquid having a closed cup ash point at or above 100F (38C). 4.3 FIRE RESISTIVE PIPE PROTECTION SYSTEM A specic construction of devices, materials or protective coatings installe

35、d around (such as sleeve or wrap types), or applied to (such as spray-on types), pipe and associated components (for example pipe hangers) to maintain the integrity of the pipe subjected to a standardized re exposure. 4.4 RIGID PIPING NETWORK An assembly of pipe, connections, ttings and other compon

36、ents that when combined provide a stable and continuous channel for conveying combustible liquids. Such pipe shall meet the minimum specications established by others for its anticipated use in the eld. 4.5 TEST ASSEMBLY The construction on to which the re resistive pipe protection system is install

37、ed and suspended. 4.6 TEST SPECIMEN The re resistive pipe protection system being evaluated. PERFORMANCE 5 Fire Exposure Test 5.1 Test sample 5.1.1 Each representative type of re resistive pipe protection system for which rating is desired is to be tested beneath a oor assembly unless it is determin

38、ed that all features of its intended use can be evaluated by testing with a wall assembly. A minimum of 5 ft of the test specimen shall be exposed to the re. 5.1.2 The oor or wall assembly is to be constructed of materials which offer adequate support for the re resistive pipe protection system duri

39、ng both the re exposure and water hose stream tests, but which do not inuence the physical re performance of the re resistive pipe protection system, for example, due to excessive deection or falling debris. 5.1.3 The pipe and re resistive pipe protection system are to be installed as complete syste

40、ms and are to each incorporate at least one intermediate support, connection and tting for which is representative of that for which a rating is desired. If the re resistive pipe protection system is applied in segments, a segment (splice, joint or overlap) representative of the eld application shal

41、l be included in the test sample. 5.1.4 If a rating is desired only for a specic rigid fuel pipe network, the installed re resistive pipe protection system shall simulate the condition for which rating is desired. 5.1.5 Unless a rating is desired for a specic construction, the restop system for the

42、oor opening is to be constructed using materials and techniques that provide an effective heat and smoke seal without inuencing the performance of the re resistive pipe protection system, for example as a result of degradation or excessive heat transfer to the re resistive pipe protection system wit

43、hin the restop system. The restop system is not being evaluated as part of this standard. SEPTEMBER 22, 2016 UL 1489 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 5.1.6 The periphery of the test sample is to be not closer than 12 in (305

44、mm) from the furnace edge. The distance between the test sample periphery and furnace edge may be reduced if it is demonstrated that the edge effects do not affect the test results. 5.2 Conditioning 5.2.1 Prior to re testing, each re resistive pipe protection system and oor or wall assembly is to be

45、 conditioned, if necessary, to provide a moisture condition representative of that likely to exist in similar constructions in buildings. The oor or wall assembly may be conditioned independently of the re resistive pipe protection systems. The test moisture condition is to be considered as that whi

46、ch would be established in equilibrium resulting from drying of a sample in air having 50% relative humidity at 73F (23C). If it is impractical to achieve this equilibrium moisture condition, the test may be conducted when the dampest portion of the test assembly and test sample have achieved an equ

47、ilibrium moisture content corresponding to drying in air having 50 to 75% relative humidity at 73 5F (23 3C). Exception: These requirements may be waived if: a) An equilibrium moisture condition is not achieved within a 12 month conditioning period; or b) The construction is such that drying of the

48、interior of the assembly is prevented by hermetic sealing of the construction materials. In these cases, the conditioning need then be continued only until the test assembly has developed sufficient strength to retain the test samples securely in position. 5.2.2 A procedure with electric sensing ele

49、ments may be used to determine the relative humidity within a test assembly and test sample made of materials other than concrete. 5.3 Protection of assembly and sample 5.3.1 The testing equipment, test sample and assembly are to be protected from any condition of wind or weather that might inuence the test results. The ambient air temperature at the beginning of the test is to be within the range of 50 to 90F (10 to 32C). The velocity o

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1