1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1598A Supplemental Requirements for Luminaires for Installation on Marine VesselsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL
2、COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Supplemental Requirements for Luminaires for Installation on Marine Vessels, UL 1598A First Edition, Dated December 4, 2000 Summary of Topics This revision to ANSI/UL 15
3、98A is being issued to remove the reference to the withdrawal date of UL 873 and to address universal upkeep of UL Standards for Safety. These revisions are considered to be non-substantive and not subject to ULs STP process. Text that has been changed in any manner or impacted by ULs electronic pub
4、lishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in the margin and are followed by an effective date note indicating the date of publication or the date on which the changed requirement becomes effective. All rights reserved. No par
5、t of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, incl
6、uding but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or
7、the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of
8、ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchase
9、rs computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revi
10、sed and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. APRIL 17, 2015 UL 1598A tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APRIL 17, 2015 UL 1598A tr2 No Text on
11、 This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL December 4, 2000 (Title Page Reprinted: April 17, 2015) 1 UL 1598A Standard for Supplemental Requirements for Luminaires for Installation on Marine Vessels First Edition December 4, 2
12、000 This ANSI/UL Standard for Safety consists of the First Edition including revisions through April 17, 2015. The most recent designation of ANSI/UL 1598A as a Reaffirmed American National Standard (ANS) occurred on July 1, 2014. ANSI approval for a standard does not include the Cover Page, Transmi
13、ttal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards fo
14、r Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC
15、. ANSI/UL 1598A-2005 (R2014)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JUNE 17, 2005 UL 1598A 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTR
16、ODUCTION 1 Scope .5 2 Glossary .5 3 General 6 3.1 Components .6 3.2 Units of measurement .6 3.3 Undated references .6 MECHANICAL CONSTRUCTION 4 Corrosion Protection .6 5 Openings 8 6 Joints and Gaskets 8 7 Means for Mounting .8 8 Glass and Lamp Support 9 ELECTRICAL CONSTRUCTION 9 General 9 10 Conven
17、ience Receptacles, Switches, and Fuses .9 11 Lampholders .10 12 Wiring and Conductors 10 13 Power Supply Connections 10 TEMPERATURE TEST 14 Normal Temperature Test 11 ENVIRONMENTAL TESTS 15 Drippage Test 11 16 Moisture Resistance Test 12 17 Mechanical Shock Test 12 MARKINGS 18 Markings .12 APPENDIX
18、A Standards for ComponentsA1 JUNE 17, 2005 UL 1598A 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL This page intentionally left blank. JUNE 17, 2005 UL 1598A 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION
19、WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements are supplementary to other applicable requirements in the Standard for Luminaires, UL 1598. References to requirements in UL 1598 are in italics for easy identication. 1.1 revised August 22, 2002 1.2 These requirements apply to l
20、uminaires for installation on marine vessels utilizing grounded systems in accordance with the United States Coast Guard Electrical Engineering Regulations 46 CFR, Parts 110 113, Subchapter J and, insofar as it applies, the National Electrical Code, ANSI/NFPA 70, and the Recommended Practice for Ele
21、ctrical Installations on Shipboard, IEEE 45. 1.3 These requirements do not apply to marine lighting luminaires for use in hazardous locations, as dened in the National Electrical Code, ANSI/NFPA 70, emergency lighting marine luminaires, or low voltage marine luminaires (less than 50 volts) supplied
22、solely by a battery, transformer, converter, or similar power supply source. 1.4 A product that contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of re or of electric shock or injur
23、y to persons shall be evaluated using appropriate additional component and end-product requirements to maintain the level of safety as originally anticipated by the intent of this standard. A product whose features, characteristics, components, materials, or systems conict with specic requirements o
24、r provisions of this standard does not comply with this standard. Revision of requirements shall be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this standard. 2 Glossary 2.1 For the purpose of this supplement, the following denitions
25、 apply: 2.2 INSIDE DRIPPROOF-TYPE LUMINAIRE A luminaire intended for use on a marine vessel in an inside damp or wet location and subject to oil or water drippage. 2.3 INSIDE-TYPE LUMINAIRE A luminaire intended for use on a marine vessel in an inside dry or damp location. 2.4 OUTSIDE-TYPE LUMINAIRES
26、 A luminaire intended for use outside or in other severely wet locations on a marine vessel. AUGUST 22, 2002 UL 1598A 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 3 General 3.1 Components 3.1.1 Except as indicated in 3.1.2, a component o
27、f a product covered by this standard shall comply with the requirements for that component. See Appendix A for a list of standards covering components used in the products covered by this Standard. 3.1.2 A component is not required to comply with a specic requirement that: a) Involves a feature or c
28、haracteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 3.1.3 A component shall be used in accordance with its rating established for the intended conditions of use. 3.1.4 Specic components are inc
29、omplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under those specic conditions. 3.2 Units of measurement 3.2.1 Values state
30、d without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 3.3 Undated references 3.3.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or
31、 standard. MECHANICAL CONSTRUCTION 4 Corrosion Protection 4.1 All inside and outside surfaces of cast ferrous metal, sheet metal, or ferrous tubing shall comply with the following requirements: a) Inside-type The corrosion protection means shall comply with the requirements of Clause 5.6 in the Stan
32、dard for Luminaires, UL 1598. A luminaire that complies with all of the Inside- Type requirements of this supplement shall be marked in accordance with Table 18.1, Item 1.1. b) Inside Dripproof-Type The corrosion protection means shall comply with the requirements of Clause 13.4.2 in the Standard fo
33、r Luminaires, UL 1598. A luminaire that complies with all of the Inside Dripproof-Type requirements of this supplement shall be marked in accordance with Table 18.1, Item 1.2. c) Outside-Type (fresh water only) The corrosion protection means shall comply with the requirements of Clause 13.4.2 in the
34、 Standard for Luminaires, UL 1598. A luminaire that complies with all of the Outside-Type requirements for this supplement and has been evaluated only for fresh water shall be marked in accordance with Table 18.1, Item 1.3. JUNE 17, 2005 UL 1598A 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER R
35、EPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL d) Outside-Type The corrosion protection means shall comply with the Standard Test Method of Salt Spray (Fog) Testing, ASTM B117 for 200 hours. The material shall not show pitting, cracking, or other deterioration more severe than that resulting
36、 from a similar test on passivated AISI type 304 stainless steel. A luminaire that complies with all of the Outside-Type requirements of this supplement shall be marked in accordance with Table 18.1, Item 1.4. 4.1 revised June 17, 2005 4.2 All inside and outside surfaces of cast aluminum, sheet alum
37、inum, or aluminum tubing shall comply with the following requirements: a) Inside-Type or Inside Dripproof-Type shall comply with the following, as applicable: 1) Unplated Sheet Aluminum material shall be an alloy of the 5000 series as given in the Standard Specication for Aluminum-Alloy Sheet and Pl
38、ate, ANSI/ASTM B209. 2) Unplated Cast or Machined Aluminum material shall be one of the alloys included in Table 4.1. 3) Painted or Plated Aluminum use of other aluminum alloys is not prohibited when they have an additional coating or plating corrosion protection means which complies with Clause 13.
39、4.2.2 (c), (d), or (e), in the Standard for Luminaires, UL 1598. 4) Other unplated aluminum alloys equivalent in corrosion resistance to (1) or (2). b) Outside-Type shall comply with the following as applicable: 1) The unplated, plated, or painted aluminum alloy shall have a copper content of 0.4 pe
40、rcent or less; or 2) The unplated, plated, or painted aluminum alloy complies with the test described in 4.1(d). 4.2 revised June 17, 2005 Table 4.1 Aluminum alloys Sand-cast Permanent-mold cast Die-cast Machined bar and rod stock 353.0 356.0 360.0 5052 356.0 A356.0 A360.0 5056 A356.0 A357.0 A413.0
41、5456 A443.0 A443.0 C443.0 6061 B443.0 B443.0 518.0 512.0 512.0 514.0 535.0 520.0 710 NOTE These designations conform with those given in the specications of the ANSI H35.1. 4.3 The use of other corrosion resistant materials such as silver, corrosion-resistant stainless steel, copper, brass, bronze,
42、and copper-nickel alloys do not require any additional corrosion protection. JUNE 17, 2005 UL 1598A 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 5 Openings 5.1 There shall be no openings in a luminaire except as indicated in 5.2 and 5.3.
43、 5.2 An Inside-Type surface mounted luminaire shall have no openings in the wireway exposed to the mounting surface. 5.3 An Inside-Type surface mounted luminaire, 660 mm (26 inches) or less in length, shall have not more than two open mounting holes exposed to the mounting surface. Each hole shall b
44、e not larger than 6.4 by 12.7 mm (1/4 by 1/2 inch) or 10.2 mm (0.40 inch) in diameter. Each additional 610 mm (24 inches) of length or fraction thereof qualies the luminaire for two additional mounting holes. 5.4 An Inside-Type recessed luminaire shall have no openings in the wireway that contains u
45、ninsulated live parts. A slot or louver located in the recessed portion of the enclosure shall not exceed 9.5 cm 2 (1-1/2 square inches) in area, and any other ventilating hole provided in the recessed portion of the enclosure shall not be more than 25.4 mm (1.0 inch) in diameter. The total area of
46、ventilating openings shall not be more than 15 percent of the area of the surface in which they are located. 6 Joints and Gaskets 6.1 A seam or joint in a luminaire enclosure, for other than the Inside-Type, shall be provided with a gasket or shall be otherwise constructed to exclude oil or water dr
47、ippage. 6.2 Gaskets relied upon to exclude oil or water drippage shall comply with the gasket requirements described in Clause 13.4.5 in the Standard for Luminaires, UL 1598. 6.2 revised June 17, 2005 7 Means for Mounting 7.1 A luminaire shall be provided with a permanent mounting means. 7.2 A lumin
48、aire is not required to have a separate mounting means when it is intended to be mounted by holes that are drilled at the shipyard. 7.3 A luminaire that is intended for outlet box mounting shall be provided with the outlet box. 7.4 A pendant mounted luminaire shall be the rigid metal conduit stem-su
49、spended type only. 7.5 A uorescent luminaire using straight tube lamps shall not be of the pendant mounted type. JUNE 17, 2005 UL 1598A 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 8 Glass and Lamp Support 8.1 Glassware shall be securely mounted in a frame or held by a clamp-type tter. 8.2 Straight tube lamps used in a uorescent lamp luminaire, other than the 6-watt or 8-watt T-5 types, shall be protected against damage and dro