1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1863 Communications-Circuit Accessories STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL N
2、OT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Communications-Circuit Accessories, UL 1863 Fourth Edition, Dated May 14, 2004 Summary of Topics This revision of ANSI/UL 1863 is being issued to reaffirm ANSI approval of the Standard. The r
3、evisions are substantially in accordance with Proposal(s) on this subject dated July 29, 2016. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. All rights reserved. No part of this publication may be reproduced, st
4、ored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warra
5、nties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if
6、 UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, i
7、ndemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. SEPTEMBER 15, 2016 UL 1
8、863 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 15, 2016 UL 1863 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 14, 2004 (Title Page Rep
9、rinted: September 15, 2016) 1 UL 1863 Standard for Communications-Circuit Accessories First Edition January, 1990 Second Edition October, 1995 Third Edition May, 2000 Fourth Edition May 14, 2004 This ANSI/UL Standard for Safety consists of the Fourth Edition including revisions through September 15,
10、 2016. The most recent designation of ANSI/UL 1863 as a Reaffirmed American National Standard (ANS) occurred on September 15, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any p
11、art of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be alter
12、ed in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 1863-2004 (R2016)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTR
13、IBUTION WITHOUT PERMISSION FROM UL MAY 14, 2004 COMMUNICATIONS-CIRCUIT ACCESSORIES - UL 1863 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 General 6 2.1 Components 6 2.2 Units of mea
14、surement .6 2.3 Undated references .6 3 Glossary 7 CONSTRUCTION 4 General .10 5 Product Assembly .10 6 Enclosure .11 6.1 General .11 6.2 Enclosure top openings 13 6.3 Enclosure side openings .14 6.4 Enclosure bottom openings .17 7 Materials .18 8 Accessibility and Electric Shock .18 9 Mechanical Ass
15、embly 19 10 Protection Against Corrosion .20 11 Cords 20 11.1 General .20 11.2 Strain relief .21 11.3 Bushings .21 12 Current-Carrying Parts .22 13 Internal Wiring 22 13.1 General .22 13.2 Splices and connections .23 14 Interconnecting Cords and Cables 23 14.1 General .23 14.2 Separation of circuits
16、 24 14.3 Terminals and connectors 25 15 Insulating Material .25 16 Printed-Wiring Board .25 17 Overcurrent (Overload) Devices .26 18 Spacings .26 RISK OF INJURY TO PERSONS 19 General 27 20 Modular Jacks 27 21 Sharp Edges 28 22 Stability 29 23 Protection of Service Personnel .29 MAY 14, 2004 COMMUNIC
17、ATIONS-CIRCUIT ACCESSORIES - UL 1863 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL PERFORMANCE 24 General 30 24.1 Electronic circuits 30 24.2 Current-carrying parts 32 24.3 Enclosures .34 25 Fault Current Test .36 25.1 General .36 25.2 Cu
18、rrent-carrying parts 36 25.3 Electronic circuits 37 26 Strain-Relief Test .37 27 Leakage Current Test 38 28 Electric Shock Current Test .40 29 Normal Operation Test .44 30 Electrical Measurements Test .44 31 Dielectric Voltage-Withstand Test 44 32 Component Temperature Test 45 33 Drop Test 48 34 Imp
19、act Test .48 35 Crush Test .49 36 Millivolt Drop Test .49 37 Heat Test .49 38 Torque Test 50 39 Flex Test .51 40 Pull Test .51 41 Blunt-End Probe Test 51 42 Rain Test .52 43 Weatherometer and Tensile Test 55 44 Thermal Aging and Flame Test .56 MARKINGS 45 General 56 46 Installation Instructions .58
20、47 Instruction Manual .58 APPENDIX A Standards for ComponentsA1 MAY 14, 2004 COMMUNICATIONS-CIRCUIT ACCESSORIES - UL 1863 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover telecommunications-c
21、ircuit accessories, such as jack and plug assemblies, quick-connect terminal assemblies, telephone wall plates, telephone extension cords, cross-connect terminal-block assemblies, maintenance terminal modules, terminal enclosures, cable-splice enclosures, network-interface devices, wire-guide assemb
22、lies, and connector boxes. 1.2 These devices are intended to be used in telecommunications networks that have an operating root-mean-square (rms) voltage to ground less than 150 volts and installed or used in accordance with the National Electrical Code, ANSI/NFPA 70. 1.3 These requirements do not c
23、over telephone equipment such as telephone answering devices, residential telephone instruments, telephone dialers, cordless phones, key systems, and private-branch exchange equipment that is covered by the Standard for Information Technology Equipment Safety Part I: General Requirements, UL 60950-1
24、. Also, these requirements do not cover: a) Telephone protectors that are covered by the Standard for Protectors for Paired-Conductor Communications Circuits, UL 497, and b) Secondary protectors that are covered by the Standard for Secondary Protectors for Communications Circuits, UL 497A. 1.3 revis
25、ed May 14, 2004 1.4 These requirements do not cover receiver/transmitter-type devices. Equipment of this type is covered by the Standard for Audio-Video Products and Accessories, UL 1492, or the Standard for Audio/Video and Musical Apparatus for Household, Commercial, and Similar General Use, UL 650
26、0. These requirements do not cover cellular telephones or cellular devices. Equipment of this type is covered by UL 1492. 1.4 revised May 14, 2004 1.5 These requirements may be used, directly or by reference, to investigate portions of other equipment, not classied as telecommunications-equipment ac
27、cessories, that may be connected to a telecommunications network, insofar as they may be applicable to such equipment. 1.6 These requirements do not cover wires and cables intended to be permanently installed in a building in accordance with Article 800 of the National Electrical Code, ANSI/NFPA 70.
28、 AUGUST 21, 2008 COMMUNICATIONS-CIRCUIT ACCESSORIES - UL 1863 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2 General 2.1 Components 2.1.1 Except as indicated in 2.1.2, a component of a product covered by this standard shall comply with t
29、he requirements for that component. See Appendix A for a list of standards covering components used in the products covered by this standard. 2.1.2 A component is not required to comply with a specic requirement that: a) Involves a feature or characteristic not required in the application of the com
30、ponent in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.1.3 A component shall be used in accordance with its rating established for the intended conditions of use. 2.1.4 Specic components are incomplete in construction features or restricted in perfor
31、mance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under those specic conditions. 2.2 Units of measurement 2.2.1 Values stated without parentheses are the requirement. Values in par
32、entheses are explanatory or approximate information. 2.2.2 Unless otherwise indicated, all voltage and current values mentioned in this standard are root-mean-square (rms). 2.3 Undated references 2.3.1 Any undated reference to a code or standard appearing in the requirements of this standard shall b
33、e interpreted as referring to the latest edition of that code or standard. MAY 14, 2004 COMMUNICATIONS-CIRCUIT ACCESSORIES - UL 1863 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 3 Glossary 3.1 For the purpose of this standard the followi
34、ng denitions apply. 3.2 COMMON MODE VOLTAGE When applied to telecommunications leads, this term refers to the voltage between any conductor or connection point and earth ground. Also referred to as Longitudinal Voltage. 3.3 DIFFERENTIAL MODE VOLTAGE When applied to telecommunications leads, this ter
35、m refers to the voltage between any conductors or connection points excluding those connected to earth ground. Also referred to as Metallic Voltage. 3.4 ELECTRICAL ENERGY HIGH-CURRENT LEVELS (POWER SUPPLIES) The capability for damage or injury to persons (other than by electric shock) from available
36、 electrical energy is considered to exist when, between a live part and an adjacent dead-metal part or between live parts of different polarity, there exists a potential of 2 volts or more and either: a) An available continuous power level of 240 volt-amperes or more or b) A reactive energy level of
37、 20 joules or more. For example, a tool (or other metal) short-circuiting a component is capable of posing a risk of re, electric shock, or injury to persons (burns) when enough energy is available at the component to vaporize, melt, or more than warm the metal. 3.5 ENCLOSURE The word enclosure refe
38、rs only to parts that house or cover: a) Uninsulated live parts that involve a risk of electric shock or b) Parts that involve a risk of re, electrical energy/high-current levels, or injury to persons. An enclosure may be an integral part of a component, a separate item or part of an outer cabinet.
39、3.6 FIXED OR STATIONARY EQUIPMENT Equipment that is not easily moved, and is intended to be moved from one place to another only when de-energized. Fixed equipment is usually fastened or secured to the building. 3.7 GROUND A conducting connection, whether intentional or otherwise, between electrical
40、 circuits or electrical equipment and either the earth or some conducting body that serves in place of the earth. 3.8 GROUNDING The act of establishing a conductive connection, whether intentional or otherwise, between an electrical circuit or electrical equipment and earth. 3.9 LONGITUDINAL VOLTAGE
41、 See 3.2, Common Mode Voltage. 3.10 METALLIC VOLTAGE See 3.3, Differential Mode Voltage. 3.11 NETWORK OPERATING VOLTAGES Telecommunications networks normally operate at voltages of 56.5 volts DC or less, unless the source impedance is above the range of 300 1600 ohms. For equipment connected to a si
42、ngle tip and ring pair, alerting and test voltages higher than 56.5 volts are generally intermittent and will be present over less than 1 percent of the usage of the MAY 14, 2004 COMMUNICATIONS-CIRCUIT ACCESSORIES - UL 1863 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBU
43、TION WITHOUT PERMISSION FROM UL equipment. Some telecommunications equipment, such as PBX and Key systems, may have a greater percentage of usage or operate at a higher voltage (such as T type lines). Maximum ring voltages may not exceed 200 volts peak-to-ground or 300 volts peak-to-peak. 3.12 NONPR
44、OTECTED SIDE The portion of the loop circuit that rests on the primary side of a telephone protector installed by the operating telephone company. The fault current limitation is subject to the breakdown voltage characteristics of the primary protector and its coordinated fusing system (e.g., fuse l
45、ink or bridle wire) with which the protector is intended to be used. 3.12 revised May 14, 2004 3.13 PORTABLE EQUIPMENT Equipment that is easily moved and can be carried or conveyed by hand. Portable equipment is usually hand-held or hand-supported. 3.14 PRODUCT This term refers to all types of telep
46、hone equipment and appliances likely to be used in residential, commercial, and industrial environments. 3.15 PROTECTED SIDE Refers to that portion of the loop circuit that is connected to the secondary or output side of the primary telephone protector and is limited to short and long term current r
47、equirements for secondary protectors. 3.16 RISK OF ELECTRIC SHOCK The risk that a person encounters when exposed to live uninsulated parts of a product that have a voltage and current sufficient to cause an electric shock, as dened in Accessibility and Electric Shock, Section 8. 3.17 RISK OF FIRE Th
48、e risk that a re may occur as a result of equipment or component failure or the application of specied test conditions. A risk of re is considered to exist at any component unless an investigation of the circuit delivering power to that component complies with the power limitations criteria cited in
49、 this standard. 3.18 RISK OF INJURY TO PERSONS A risk of injury to persons is considered likely to occur when one or more of the following conditions exist: a) Sharp edges, burrs, or projections are present that can cause injury during use or servicing. b) The stability of a product is such that it can cause injury to persons. See Stability, Section 22. c) Uninsulated live parts involving a risk of electrical-energy/high-current levels are accessible to personnel. See Accessi