ANSI UL 2367-2009 UL Standard for Safety Solid State Overcurrent Protectors (First Edition Reprint with revisions through and including May 2 2014)《固态过载电流保护装置的安全标准》.pdf

上传人:roleaisle130 文档编号:439092 上传时间:2018-11-14 格式:PDF 页数:18 大小:604.08KB
下载 相关 举报
ANSI UL 2367-2009 UL Standard for Safety Solid State Overcurrent Protectors (First Edition Reprint with revisions through and including May 2 2014)《固态过载电流保护装置的安全标准》.pdf_第1页
第1页 / 共18页
ANSI UL 2367-2009 UL Standard for Safety Solid State Overcurrent Protectors (First Edition Reprint with revisions through and including May 2 2014)《固态过载电流保护装置的安全标准》.pdf_第2页
第2页 / 共18页
ANSI UL 2367-2009 UL Standard for Safety Solid State Overcurrent Protectors (First Edition Reprint with revisions through and including May 2 2014)《固态过载电流保护装置的安全标准》.pdf_第3页
第3页 / 共18页
ANSI UL 2367-2009 UL Standard for Safety Solid State Overcurrent Protectors (First Edition Reprint with revisions through and including May 2 2014)《固态过载电流保护装置的安全标准》.pdf_第4页
第4页 / 共18页
ANSI UL 2367-2009 UL Standard for Safety Solid State Overcurrent Protectors (First Edition Reprint with revisions through and including May 2 2014)《固态过载电流保护装置的安全标准》.pdf_第5页
第5页 / 共18页
亲,该文档总共18页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 2367 Solid State Overcurrent ProtectorsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FU

2、RTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Solid State Overcurrent Protectors, UL 2367 First Edition, Dated December 30, 2009 SUMMARY OF TOPICS This revision of ANSI/UL 2367 includes an updated title page to reect reaffirmation of ANSI approval. No chang

3、es in requirements are involved. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in the margin and are followed by an effective date note indicating the date

4、 of publication or the date on which the changed requirement becomes effective. The revised requirements are substantially in accordance with Proposal(s) on this subject dated March 7, 2014. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmit

5、ted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for a

6、ny purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative

7、has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and

8、 against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except fo

9、r those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are

10、preceded by a SUPERSEDED REQUIREMENTS notice. MAY 2, 2014 UL 2367 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 2, 2014 UL 2367 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION

11、WITHOUT PERMISSION FROM UL DECEMBER 30, 2009 (Title Page Reprinted: May 2, 2014) 1 UL 2367 Standard for Solid State Overcurrent Protectors First Edition December 30, 2009 This ANSI/UL Standard for Safety consists of the First Edition including revisions through May 2, 2014. The most recent designati

12、on of ANSI/UL 2367 as a Reaffirmed American National Standard (ANS) occurred on May 2, 2014. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to

13、 UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and

14、 all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2014 UNDERWRITERS LABORATORIES INC. ANSI/UL 2367-2009 (R2014)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECE

15、MBER 30, 2009 SOLID STATE OVERCURRENT PROTECTORS - UL 2367 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 Components 5 3 Units of Measurement .5 4 Undated References 5 5 Glossary .5 C

16、ONSTRUCTION 6 General 6 7 Insulating Materials 6 8 Live Parts 6 9 Corrosion Protection .6 PERFORMANCE 10 Calibration Tests .7 11 Temperature Test 8 12 Overload Operation Test 9 13 Short Circuit Test 9 14 Shipping and Storage Test 9 15 Thermal Cycling Test 10 16 Endurance Test 10 17 Abnormal Test 11

17、18 Long Term Abnormal Test .11 MANUFACTURING AND PRODUCTION TESTS 19 Limited Thermal Aging Test 11 20 Production Line Test 13 RATINGS 21 General 13 MARKINGS 22 General 13 DECEMBER 30, 2009 SOLID STATE OVERCURRENT PROTECTORS - UL 2367 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION O

18、R DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 This standard covers solid-state overcurrent protectors. These devices are solid-state switches that limit the output current to a safe level when the output load exceeds the current-limit threshold or when a load-side short-circuit

19、is present. Solid-state overcurrent protectors are intended to be used on the load-side of an isolating transformer, power supply or battery to provide a means of supplementary protection. See Table 1.1 for maximum current and power levels. Table 1.1 Maximum current and power levels Output voltage (

20、V oc ) Output current (I sc ) V ac V dc A( V A) 20 20 1000 / V oc 250 20 V oc 30 20 V oc 30 1000 / V oc 250 3 0 V oc 60 1000 / V oc 250 1.2 The devices covered by these requirements are integrated circuits, and electrical spacings within the devices are not specied. 1.3 The devices covered by these

21、requirements are entirely electronic in nature and have no means for manual operation or reset. 1.4 The terminals of the devices covered by these requirements are for factory wiring only (intended to be mounted on a printed wiring board). 1.5 The devices covered by these requirements shall only be u

22、sed on supply circuits originating from an isolating transformer, a power supply or a battery with limited maximum current and power levels as noted in Table 1.1. Use on supply circuits with a higher power capability requires additional evaluation for reliability, such as those requirements containe

23、d in the Standard for Safety-Related Controls Employing Solid-State Controls, UL 991. 1.6 The devices covered by these requirements limit output currents to values less than the overcurrent protection rating of 5 amperes. 1.7 The devices covered by these requirements have only been evaluated for sup

24、plementary overcurrent protection of secondary circuits supplied by the load side of a transformer, power supply or battery and have not been evaluated for branch-circuit protection. 1.8 This standard may cover devices intended for use in telecommunications applications. However, devices intended fo

25、r connection to telecommunications networks with outside plant connections should be evaluated in the end-use in accordance with the requirements of the Standard for Information Technology Equipment Safety - Part 1: General Requirements, UL 60950-1, or the Standard for Secondary Protectors for Commu

26、nication Circuits, UL 497A, as appropriate. DECEMBER 30, 2009 SOLID STATE OVERCURRENT PROTECTORS - UL 2367 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2 Components 2.1 A component is not required to comply with a specic requirement that

27、: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.2 A component shall be used in accordance with its rating established for the intended conditions of use. 2.3 S

28、pecic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under those specic conditions. 3 Units of Measurem

29、ent 3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 4 Undated References 4.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition

30、 of that code or standard. 5 Glossary 5.1 For the purpose of this outline, the following denitions apply: 5.2 ENCAPSULANT A molding material that is typically cast or injection molded around and is intended to insulate and protect the device. Encapsulated devices do not employ supplementary surround

31、ing shells hence the encapsulant functions as an electrical enclosure. 5.3 EXPOSED PLANT (OUTSIDE PLANT) Any portion of the telecommunications network subject to accidental contact with or induction from power conductors at a voltage exceeding 300V to ground. This includes circuitry that is intended

32、 to be connected to the Public Switched Telephone Network (PST-N), Off-Premises Extension (OPE) lines, and the like. 5.4 MAXIMUM CONTINUOUS CURRENT (CONT. CURRENT) This designation is the ampere rating for which a protector or family of protectors has been tested for continuous current operation. 5.

33、5 PROTECTIVE CURRENT (PROT. CURRENT) This designation is the ampere rating for which a protector or family of protectors has been tested for providing overcurrent protection. 5.6 TELECOMMUNICATION (TELEPHONE) NETWORK CIRCUIT An electrical circuit conductively connected to the telephone company commu

34、nications facilities. 5.7 TELECOMMUNICATION NETWORK CONNECTIONS (TNC) Identied as follows: a) Not intended for use on telecommunication network with outside plant connections. b) Intended for use on telecommunication network with outside plant connections. DECEMBER 30, 2009 SOLID STATE OVERCURRENT P

35、ROTECTORS - UL 2367 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 5.8 VOLTAGE RANGE (VOLTS) This designation is the voltage range for which a protector or family of protectors has been tested. Unless specied otherwise, all voltages are di

36、rect current (DC). CONSTRUCTION 6 General 6.1 A solid-state overcurrent protector shall be constructed in compliance with Sections79 . 7 Insulating Materials 7.1 Uninsulated live parts involving risk of re, electric shock or electrical-energy/high-current levels shall be mounted on porcelain, phenol

37、ic-composition or other material that is intended for the application. 7.2 Thermoplastic materials used for the direct or indirect support of uninsulated live parts involving a risk of re, electric shock, or electrical-energy/high-current shall comply with the requirements in the Standard for Polyme

38、ric Materials Use in Electrical Equipment Evaluations, UL 746C. 7.3 Molded parts shall have the mechanical strength and rigidity to withstand the stresses of actual service. 7.4 Materials used as encapsulants shall operate within their RTI as specied in the Standard for Polymeric Materials Long Term

39、 Property Evaluations, UL 746B or alternatively shall comply with the Limited Thermal Aging Test, Section 19. 8 Live Parts 8.1 Metal employed for current-carrying parts shall be of stainless steel, silver, gold, copper, nickel, aluminum, an alloy of the same, or an equivalent material. 9 Corrosion P

40、rotection 9.1 Iron and steel parts shall be protected against corrosion by enameling, galvanizing, plating, or other equivalent means. Exception: Encapsulated parts and stainless steel parts need not be provided with plating. DECEMBER 30, 2009 SOLID STATE OVERCURRENT PROTECTORS - UL 2367 6UL COPYRIG

41、HTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL PERFORMANCE 10 Calibration Tests 10.1 A Solid State Overcurrent Protector shall operate in accordance with the parameters shown in Tables 10.1 and 10.2. There shall be no emission of ame or molten metal

42、from the device during testing or evidence of a risk of re as determined by the indicator described in 10.2. 10.2 During the test, the grounding means is to be connected to ground through a 3-ampere non-time-delay fuse and the unit is to be draped with a double layer of cheesecloth conforming to the

43、 outline of the unit. 10.3 The component or circuit is to be mounted in its intended manner. 10.4 When a range of values for one component or circuit construction is to be evaluated, samples of the minimum, mean, and maximum rating are to be tested. All tests are to be conducted at a 25.0 3C ambient

44、. 10.5 The operating time and limiting shall be consistent and in accordance with the tolerances specied by the manufacturers curve of opening time versus current or wattage. 10.6 The manufacturers operating time curve is to be veried by checking four points, including high and low values, along the

45、 curve. Five separate component or circuit samples are to be used to check each of the four points. If no curve exists, this test shall be used to determine a set of reference points the component or circuit can be judged against after each of the required tests. 10.7 After each of the tests specied

46、 in Sections 12 18, the Calibrations Tests are to be repeated. The results are considered acceptable if there is no change in the measured operating characteristics of more than 5 percent. Exception: An open circuit would be considered an acceptable result. Table 10.1 Maximum acceptable time for ope

47、ration of protective device Output voltage (V oc ) Output current (I sc ) A Maximum time for protective device to operate (minutes) V ac V dc 20 20 10 a 2 20 20 6.75 b 60 20 V oc 30 20 V oc 30 200 / V max a,c 2 20 V oc 30 20 V oc 30 135 / V max b,c 60 3 0 V oc 60 200 / V max a,c 2 3 0 V oc 60 135 /

48、V max b,c 60 a The load is to be adjusted continuously to maintain the test current value shown. b After 15 minutes of operation, the load is to be readjusted to return to the output current value shown. c V max is the maximum output voltage regardless of load with rated input. DECEMBER 30, 2009 SOL

49、ID STATE OVERCURRENT PROTECTORS - UL 2367 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Table 10.2 Maximum acceptable time for protection device to trip Output voltage (V oc ) Rated protective current (A) Test current, Percent of rated current Maximum trip time (seconds) 20 5.0 210 120 2 0 1 0 0/V oc 210 120 11 Temperature Test 11.1 The device shall carry rated out

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1