ANSI UL 2560-2011 UL Standard for Safety Emergency Call Systems for Assisted Living and Independent Living Facilities (First Edition Reprint with revisions through and including Ma.pdf

上传人:jobexamine331 文档编号:439131 上传时间:2018-11-14 格式:PDF 页数:120 大小:1,008.98KB
下载 相关 举报
ANSI UL 2560-2011 UL Standard for Safety Emergency Call Systems for Assisted Living and Independent Living Facilities (First Edition Reprint with revisions through and including Ma.pdf_第1页
第1页 / 共120页
ANSI UL 2560-2011 UL Standard for Safety Emergency Call Systems for Assisted Living and Independent Living Facilities (First Edition Reprint with revisions through and including Ma.pdf_第2页
第2页 / 共120页
ANSI UL 2560-2011 UL Standard for Safety Emergency Call Systems for Assisted Living and Independent Living Facilities (First Edition Reprint with revisions through and including Ma.pdf_第3页
第3页 / 共120页
ANSI UL 2560-2011 UL Standard for Safety Emergency Call Systems for Assisted Living and Independent Living Facilities (First Edition Reprint with revisions through and including Ma.pdf_第4页
第4页 / 共120页
ANSI UL 2560-2011 UL Standard for Safety Emergency Call Systems for Assisted Living and Independent Living Facilities (First Edition Reprint with revisions through and including Ma.pdf_第5页
第5页 / 共120页
亲,该文档总共120页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 2560 Emergency Call Systems for Assisted Living and Independent Living FacilitiesUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL

2、COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Emergency Call Systems for Assisted Living and Independent Living Facilities,UL 2560 First Edition, Dated September 13, 2011 Summary of Topics This revision was issued t

3、o incorporate the following changes: 1. Proposed new test methods for spread spectrum technologies 2. Identication of UL 2560 requirements considered to be met by a product that already complies with UL 60950-1 3. Proposal to provide an additional option (the use of a symbol) for marking a device, s

4、uch as a switch, intended for emergency service 4. Products intended for outdoor use 5. Proposed changes to the battery life test 6. Requirements for openings in non-resident-accessible equipment The effective date for UL LLC will be announced through Industry File Review Announcement Letter. The ne

5、w/revised requirements are substantially in accordance with Proposal(s) on this subject dated August 8, 2014 and March 27, 2015. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. All rights reserved. No part of this

6、 publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but

7、 not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inabi

8、lity to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Stand

9、ards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers comput

10、er system. MAY 28, 2015 UL 2560 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 28, 2015 UL 2560 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEM

11、BER 13, 2011 (Title Page Reprinted: May 28, 2015) 1 UL 2560 Standard for Emergency Call Systems for Assisted Living and Independent Living Facilities First Edition September 13, 2011 This ANSI/UL Standard for Safety consists of the First Edition including revisions through May 28, 2015. The most rec

12、ent designation of ANSI/UL 2560 as an American National Standard (ANSI) occurred on May 28, 2015. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Propos

13、als should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, owners

14、hips, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC. ANSI/UL 2560-2015UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 28, 2015 UL 2560 2 No Text on T

15、his PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .7 2 General 7 2.1 System conguration 7 2.2 Components .8 2.3 Units of measurement .8 2.4 Undated references .8 2.5 Maximum voltage and power .8 3 Glossary

16、 .9 CONSTRUCTION 4 General .12 5 Enclosures .12A 5.1 General .12A 5.2 Cast metal 13 5.3 Sheet metal 13 5.4 Nonmetallic .15 5.5 Ventilating openings .15 5.6 Covers .16 5.7 Observation opening covers 17 5.8 General enclosure openings non-resident accessible equipment .17 5.9 Enclosure top openings non

17、-resident accessible equipment .18 5.10 Enclosure side openings non-resident accessible equipment .18 5.11 Enclosure bottom openings non-resident accessible equipment .18E 6 Electric Shock 18F 7 Corrosion Protection 18F 8 Field Wiring System Connections 18G 8.1 General .18G 8.2 Terminals .19 8.3 Lea

18、ds 21 8.4 Interconnecting wiring 21 8.5 Equipment grounding connection 22 8.6 Supply connections 22 8.7 Grounded supply conductor connection 23 8.8 Compartments 23 8.9 Strain relief .23 9 Internal Wiring .23 9.1 General 23 9.2 Wireways .24 9.3 Splices .24 9.4 Barriers 24 9.5 Bushings .24 10 Bonding

19、for Grounding 25 11 Components .26 11.1 Printed-wiring boards .26 11.2 Coil windings 26 11.3 Switches 26 11.4 Light sources 26 MAY 28, 2015 UL 2560 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 11.5 Protective devices 27 11.6 Connectors a

20、nd receptacles .27 11.7 Pillow speakers/call cords .27 11.8 Transformers 28 11.9 Current-carrying parts .29 11.10 Insulating material .29 11.11 Mounting of parts .30 11.12 Operating mechanisms 30 12 Secondary Power Supply 31 12.1 General .31 12.2 Power supply supervision test .31 12.3 Battery chargi

21、ng test 32 12.4 Battery discharge test .32 13 Storage Batteries .32 14 Spacings 32 15 Testing, Servicing, and Maintenance Protection 34 PERFORMANCE 16 General 34 17 Normal Operation Test .34B 18 Electrical Supervision .38 18.1 General .38 18.2 All centralized systems 40 19 Voltage and Current Measur

22、ements .40 19.1 Input circuit 40 19.2 Output circuit 40 19.3 Volt-ampere capacity low-voltage power-limited circuits .40 20 Overvoltage and Undervoltage Operation Test .42 20.1 Overvoltage operation 42 20.2 Undervoltage operation .43 21 Jarring Test 43 22 Temperature Test .44 23 Overload Test 48 23.

23、1 Signaling unit 48 23.2 Separately energized circuits 49 24 Endurance Test 49 25 Variable Ambient Temperature Test .50 26 Humidity Test 50 27 Electric Shock Current Test 50 28 Leakage Current Test .54 29 Transient Test 56 29.1 General .56 29.2 Supply line transients high-voltage units .57 29.3 Inte

24、rnally induced transients all units 57 30 Dielectric Voltage-Withstand Test .57 31 Static Discharge Test .58 32 Drop Test 59 33 Component Failure Test .59 34 Abnormal Tests .59 34.1 Abnormal operation test .59 34.2 Burnout test .60 34.3 Circuit isolation supplementary equipment .60 MAY 28, 2015 UL 2

25、560 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 35 Tests for Special Terminal Assemblies 61 35.1 General .61 35.2 Mechanical secureness test .61 35.3 Flexing test 61 35.4 Millivolt drop test .62 35.5 Terminal temperature test .62 36 Pol

26、ymeric Materials Test .62 36.1 General .62 36.2 Temperature test .62 36.3 3/4-inch ame test 63 36.4 5-inch ame test .64 37 Strain Relief Test .65 37.1 Power supply cord 65 37.2 Field wiring leads .65 38 Water Spray and Submersion Tests .66 38.1 Water spray test .66 38.2 Submersion test 69 39 Impact

27、Test 69 40 Wireless Devices .69 40.1 General .69 40.2 Primary batteries .70 40.3 Low-power radio-frequency signaling .70 40.4 Frequency selectivity .71 40.5 Clash .71 40.6 Clash error .72A 40.7 Error (falsing) rate .72B 40.8 Throughput rate 73 40.9 Transmitter stability tests 74 40.10 Transmitter ac

28、celerated aging test .74 40.11 Reference level determination 75 41 Primary Batteries Test .75 41.1 Life test .75 41.2 Battery trouble voltage determination .77 41.3 Battery replacement test 80 41.4 Butt-type connection pressure test .81 41A Outdoor Use 81 41A.1 General 81 41A.2 Corrosion tests .81 4

29、1A.3 Dust test .82 41A.4 Water spray test .82A 41A.5 Gasket testing .82B 41A.6 Polymeric materials outdoor use tests 82D 41A.7 Outdoor conditioning test .82D 41B Ignition Test Through Bottom-Panel Openings .82E MANUFACTURING AND PRODUCTION TESTS 42 Production-Line Dielectric Voltage-Withstand Test .

30、82F 43 Production-Line Grounding Continuity Test .82G MARKINGS 44 General 82G MAY 28, 2015 UL 2560 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 45 Label Design .86 46 Label Colors .86 INSTRUCTIONS AND INSTALLATION DRAWINGS 47 Details .86

31、 PROGRAM-CONTROLLED AND SIGNALING EQUIPMENT AND SYSTEMS 48 General 88 49 Program Access and Control .88 APPENDIX A Standards for ComponentsA1 MAY 28, 2015 UL 2560 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 Thes

32、e requirements cover the individual unit employed to form assisted and independent living emergency call systems (ECS) intended to provide audible and visual signaling between residents and assisted and independent living facility staff. Some examples include call initiation stations, call noticatio

33、n stations, and power supplies. 1.2 The units covered by these requirements are intended to be installed in either general or resident areas in accordance with the National Electrical Code, NFPA 70. 1.3 These requirements are not intended to cover signaling systems in a hospital or acute/skilled car

34、e environment. Requirements for systems of this nature are covered by the Standard for Hospital Signaling and Nurse Call Equipment, UL 1069. 2 General 2.1 System conguration 2.1.1 The minimum fundamental conguration shall consist of the following: a) An emergency call-initiation station with a call

35、assurance indicator suitable for permanent installation in each resident living unit. Typical applications will utilize pendants for residents, multiple call initiation stations in each living unit, and additional call initiation stations in common areas within the facility. b) Call notication stati

36、on(s) that receive calls, one of which must be installed at a xed location. 2.1.2 An ECS employs a dedicated wired, dedicated wireless, or combination of these means for initiation of a resident or staff call, requiring attention. 2.1.3 An Emergency Call System has a Secondary (battery backup) Power

37、 Supply. The length of backup is specied by the manufacturer. SEPTEMBER 13, 2011 UL 2560 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2.2 Components 2.2.1 Except as indicated in 2.2.2, a component of a product covered by this standard sh

38、all comply with the requirements for that component. See Appendix A for a list of standards covering components generally used in the products covered by this standard. 2.2.2 A component is not required to comply with a specic requirement that: a) Involves a feature or characteristic not required in

39、 the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.2.3 A component shall be used in accordance with its rating established for the intended conditions of use. 2.2.4 Specic components are incomplete in construction featu

40、res or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under those specic conditions. 2.3 Units of measurement 2.3.1 Values stated without parentheses are the

41、 requirement. Values in parentheses are explanatory or approximate information. 2.3.2 Unless otherwise specied, all voltages are rms. 2.4 Undated references 2.4.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the lates

42、t edition of that code or standard. 2.5 Maximum voltage and power 2.5.1 The maximum voltages to an emergency call initiation station, where wet contact is likely to occur (see Wet Area, 3.44), , shall not be more than 15 volts, 60 hertz sinusoidal, 30 volts continuous DC, 21.2 volts peak for nonsinu

43、soidal AC, and 12.4 volts for DC that is interrupted at a rate of 10 200 hertz. See Voltage and Current Measurements, Section 19. SEPTEMBER 13, 2011 UL 2560 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 3 Glossary 3.1 For the purposes of

44、this standard the following denitions apply. 3.2 ASSURANCE INDICATOR Visual or audible indication on the call initiation station signifying placement of a call. 3.3 AUDIO COMMUNICATION Two way voice communication between the call notication station and the call initiating device. 3.4 BATTERY, PRIMAR

45、Y A primary means of powering a device where the battery is not recharged during normal operation. 3.5 BATTERY, STANDBY A power source utilizing a battery to provide secondary power or the battery used to provide secondary power. See Secondary Power, 3.39. 3.6 CALL CORD A cord with a switch at one e

46、nd and a connector at the other that typically plugs into a call initiation station. The resident places a call to the staff by momentarily pressing the switch. 3.7 CALL INITIATION STATION Any of several types of devices that are able to initiate a call for assistance or to communicate a change in s

47、tatus (to reset or cancel the call) to the emergency call system. 3.8 CALL NOTIFICATION STATION Any of several types of indicating devices that audibly and visually notify the appropriate staff that a call for assistance has been made. 3.9 CENTRALIZED SYSTEM A system whose operations are monitored a

48、nd controlled from a call notication station. It includes call initiation stations installed in resident and related areas that are not normally visible from the central control point. 3.10 CIRCUIT, HIGH-VOLTAGE A circuit having characteristics in excess of those of a low-voltage, power-limited circ

49、uit as dened in 3.11. 3.11 CIRCUIT, LOW-VOLTAGE (POWER-LIMITED) A circuit involving a potential of not more than 30 volts AC, rms (42.4 volts DC or AC peak) and not providing more than 100 volt-amperes rated output. 3.12 CLASS 2 CIRCUITS Circuits that conform to the Class 2 circuit requirements of Article 725 of the National Electrical Code, NFPA 70. Class 2 circuits are power-limited, either inherently or by a combination of protections against excessive current at the power

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有