ANSI UL 4248-11-2007 UL Standard for Safety Fuseholders - Part 11 Type C (Edison Base) and Type S Plug Fuse (First Edition Reprint with Revisions Through and Including April 4 2018.pdf

上传人:李朗 文档编号:439211 上传时间:2018-11-14 格式:PDF 页数:27 大小:794.96KB
下载 相关 举报
ANSI UL 4248-11-2007 UL Standard for Safety Fuseholders - Part 11 Type C (Edison Base) and Type S Plug Fuse (First Edition Reprint with Revisions Through and Including April 4 2018.pdf_第1页
第1页 / 共27页
ANSI UL 4248-11-2007 UL Standard for Safety Fuseholders - Part 11 Type C (Edison Base) and Type S Plug Fuse (First Edition Reprint with Revisions Through and Including April 4 2018.pdf_第2页
第2页 / 共27页
ANSI UL 4248-11-2007 UL Standard for Safety Fuseholders - Part 11 Type C (Edison Base) and Type S Plug Fuse (First Edition Reprint with Revisions Through and Including April 4 2018.pdf_第3页
第3页 / 共27页
ANSI UL 4248-11-2007 UL Standard for Safety Fuseholders - Part 11 Type C (Edison Base) and Type S Plug Fuse (First Edition Reprint with Revisions Through and Including April 4 2018.pdf_第4页
第4页 / 共27页
ANSI UL 4248-11-2007 UL Standard for Safety Fuseholders - Part 11 Type C (Edison Base) and Type S Plug Fuse (First Edition Reprint with Revisions Through and Including April 4 2018.pdf_第5页
第5页 / 共27页
亲,该文档总共27页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 4248-11 Fuseholders Part 11: Type C (Edison Base) and Type S Plug Fuse STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION F

2、ROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Fuseholders Part 11: Type C (Edison Base) and Type S Plug Fuse, UL 4248-11 First Edition, Dated February 28, 2007 Summary of Topics This revision to ANSI/UL 424

3、811 is being issued to make an editorial correction. No changes in requirements have been made. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. All rights reserved. No part of this publication may be reproduced, s

4、tored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warr

5、anties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even i

6、f UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend,

7、indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. JANUARY 13, 2017 UL 42

8、48-11 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 13, 2017 UL 4248-11 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Association of Standardiz

9、ation and Certication NMX-J-009/4248/11-ANCE First Edition CSA Group CAN/CSA-C22.2 No. 4248.11-07 First Edition Underwriters Laboratories Inc. UL 4248-11 First Edition Fuseholders Part 11: Type C (Edison Base) and Type S Plug Fuse February 28, 2007 (Title Page Reprinted: January 13, 2017) ANSI/UL 42

10、48-11-2007 (R2012) Approved byUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Commitment for Amendments This standard is issued jointly by the Association of Standardization and Certication (ANCE), the Canadian Standards Association (operati

11、ng as “CSA Group”), and Underwriters Laboratories Inc. (UL). Comments or proposals for revisions on any part of the standard may be submitted to ANCE, CSA Group, or UL at any time. Revisions to this standard will be made only after processing according to the standards development procedures of ANCE

12、, CSA Group, and UL. CSA Group and UL will issue revisions to this standard by means of a new edition or revised or additional pages bearing their date of issue. ANCE will incorporate the same revisions into a new edition of the standard bearing the same date of issue as the CSA Group and UL pages.

13、Copyright 2017 ANCE Rights reserved in favor of ANCE. ISBN 1-55436-047-1 2017 CSA Group All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher. To purchase the CSA Group Standards and related publications, visit CSA Gro

14、ups Online Store at shop.csa.ca or call toll-free 18004636727 or 4167474044. This Standard is subject to periodic review, and suggestions for its improvement will be referred to the appropriate committee. To submit a proposal for change, please send the following information to inquirescsagroup.org

15、and include “Proposal for change” in the subject line: Standard designation (number); relevant clause, table, and/or gure number; wording of the proposed change; and rationale for the change. Copyright 2017 Underwriters Laboratories Inc. To purchase UL Standards, visit COMM 2000 at http:/m- or call

16、toll free 18888533503. This ANSI/UL Standard for Safety consists of the First Edition including revisions through December 21, 2012. The most recent designation of ANSI/UL 4248-11 as a Reaffirmed American National Standard (ANS) occurred on December 21, 2012. ANSI approval for a standard does not in

17、clude the Cover Page, Transmittal Pages, Title Page (front and back), or the Preface. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CS

18、DS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL.UL COPYRIGHTE

19、D MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface . 4 1 General 6 1.1 Scope .6 4 Classication 6 5 Characteristics .6 5.1 Summary of characteristics .6 6 Marking .7 6.1 Marking of fuseholder 7 7 Construction .7 7.4 Current-carrying parts .7

20、 7.6 Contacts of a cartridge fuseholder 8 7.7 Creepage and clearance 9 7.8A Type S plug fuseholders and adapters 10 8 Tests .18 8.1 General .18 8.4 Verication of temperature rise 18 8.6A Verication of contactrejection member effectiveness 21 8.7A Verication of screw shell secureness .21 FEBRUARY 28,

21、 2007 NMX-J-009/4248/11-ANCE CSA C22.2 NO. 4248.11-07 UL 4248-11 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Preface This is the common ANCE, CSA Group, and UL standard for Fuseholders Part 11: Type C (Edison Base) and Type S Plug Fuse.

22、 It is the rst edition of NMX-J-009/4248/11-ANCE, the rst edition of CSA C22.2 No. 4248-11, and the rst edition of UL 4248-11. This common standard was prepared by the Association of Standardization and Certication (ANCE), CSA Group, and Underwriters Laboratories Inc. (UL). The efforts and support o

23、f the CANENA Technical Harmonization Subcommittee 32B Fuseholders are gratefully appreciated. This standard is considered suitable for use for conformity assessment within the stated scope of the standard. This standard was reviewed by the CSA Subcommittee on Low voltage fuses, under the jurisdictio

24、n of the CSA Technical Committee on Industrial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. This standard will be submitted to the Standards Council of Canada for approval as a National Standar

25、d of Canada. This standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. A UL standard is current only if it incorporates the most recently adopted revisions, all of which are itemized on the transmittal notice that accompanies the latest set

26、 of revised requirements. Where reference is made to a specic number of samples to be tested, the specied number shall be considered a minimum quantity. Note: Although the intended primary application of this standard is stated in its scope, it is important to note that it remains the responsibility

27、 of the users of the standard to judge its suitability for their particular purpose. Level of harmonization This standard is published as an identical standard for ANCE, CSA Group, and UL. An identical standard is a standard that is exactly the same in technical content except for national differenc

28、es resulting from conicts in codes and governmental regulations. Presentation is word for word except for editorial changes. Interpretations The interpretation by the standards development organization of an identical or equivalent standard is based on the literal text to determine compliance with t

29、he standard in accordance with the procedural rules of the standards development organization. If more than one interpretation of the literal text has been identied, a revision is to be proposed as soon as possible to each of the standards development organizations to more accurately reect the inten

30、t. JANUARY 13, 2017 NMX-J-009/4248/11-ANCE CSA C22.2 NO. 4248.11-07 UL 4248-11 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 13, 2017 NMX-J-009/4248/11-ANCE CSA C22.2 NO. 4248.11-07 UL 4248-11 5 No Text on This PageUL COPYRIGHTED

31、MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Fuseholders Part 11: Type C (Edison Base) and Type S Plug Fuse 1 General This Part is intended to be read together with the Standard for Fuseholders Part 1: General Requirements hereafter referred to as Part

32、1. The numbering of the Clauses in this Part corresponds to like numbered Clauses in Part 1. The requirements of Part 1 apply unless modied by this Part. For Clauses not shown below, refer to the Standard for Fuseholders Part 1: General Requirements, NMX-J-009-4248-ANCE CSA C22.2 No. 4248.1 UL 4248-

33、1. 1.1 Scope 1.1.2 These requirements cover: a) fuseholders intended for use with Type C (Edison-base) and Type S Plug Fuses as described in NMX-J-009/248/11-2000-ANCE, CSA C22.2 No. 248.11, UL 248-11, Low-Voltage Fuses Part 11: Plug Fuses; b) devices intended to be added to Edison-base fuseholders

34、to reject fuses with larger ampere ratings; and c) devices intended to adapt Type S plug fuses for use in Edison-base fuseholders. 4 Classication 4.1 Plug fuse fuseholders have a short-circuit withstand rating of 10,000 A. Plug fuse fuseholders are rated 250 V or less, and may be of Edison-base or T

35、ype S base design. 5 Characteristics 5.1 Summary of characteristics 5.1.3 Voltage and current rating 5.1.3.1 Plug fuse fuseholders shall be rated 125, 127, or 250 V. 5.1.3.2 Plug fuse fuseholders shall be rated 15, 20, or 30 A. JANUARY 13, 2017 NMX-J-009/4248/11-ANCE CSA C22.2 NO. 4248.11-07 UL 4248

36、-11 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 5.1.4 Withstand rating 5.1.4.1 Plug fuse fuseholders shall have a short-circuit withstand rating of a 10,000 A. 6 Marking 6.1 Marking of fuseholder 6.1.1.1 In addition to the requirements

37、of Part 1, Clauses 6.1.1.2 and 6.1.1.3 shall apply. 6.1.1.2 The marked current rating of a Type S fuseholder shall be located so that it will be plainly visible after installation. 6.1.1.3 A Type S adapter need not be marked with a withstand rating if the smallest unit package is marked Withstand Ra

38、ting 10,000 rms amperes when installed in an Edison-base fuseholder marked 10,000 rms amperes. 7 Construction 7.4 Current-carrying parts 7.4.1 Except for plated No. 10 and larger wire-binding screws and nuts and stud terminals, iron or steel, plain or plated, shall not be used for parts that are dep

39、ended upon to carry current. A plated iron or steel washer may be used under the center contact of an Edison-base plug fuseholder. 7.4.2 In a plug-fuseholder assembly intended for the connection of 15 A branch circuits, the ampacity of bus bars shall be as specied in Table 7.4A. Table 7.4A Minimum a

40、mpacity of bus bars Total number of fuses per ungrounded bus bar a Minimum ampacity 2-wire mains 125 250 V, 3-wire mains 3-phase, 4-wire mains 23 03 03 0 33 53 33 1 44 84 24 0 56 65 0 66 66 0 7o r8 8 4 9o r1 0 1 0 0 11 or 12 120 a For an assembly that has an unequal number of fuses per ungrounded bu

41、s bar, calculations shall be based on the larger number of fuses per ungrounded bus bar. FEBRUARY 28, 2007 NMX-J-009/4248/11-ANCE CSA C22.2 NO. 4248.11-07 UL 4248-11 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 7.6 Contacts of a cartridg

42、e fuseholder This section of Part 1 is not applicable to plug fuse fuseholders. The following requirements replace this section of Part 1. 7.6.1 Screw shells of Edison-base plug fuseholders 7.6.1.1 The thickness of the screw shell of a plug fuseholder, measured on the at surface of the bottom of the

43、 shell, shall not be less than 0.30 mm (0.012 in). 7.6.1.2 The screw shell of a plug fuseholder shall be made of copper or copper alloy. Aluminum or an aluminum alloy shall not be used. 7.6.1.3 A screw shell shall be of the medium-base size and shall, when tested with gauges made in conformity with

44、the American National Standard Dimensions for Rolled Threads for Screw Shells of Electric Lampholders and for Screw Shells of Unassembled Lamp Bases, ANSI C81.1, go and not go as applicable. 7.6.1.4 The distance between the center contact and the plane of the edge of the insulation material surround

45、ing the screw shell of a plug fuseholder, dimension K in Figure 7.6A, shall not be less than 19.1 mm (0.750 in) nor more than 20.6 mm (0.812 in). The distance between the center contact and the plane of the outer edge of the screw shell, dimension L, shall not be less than 14.3 mm (0.562 in) nor mor

46、e than 17.5 mm (0.687 in). In a fuseholder with a spring-type center contact, the dimensions K and L shall be measured with the contact fully depressed. There shall not be fewer than two full threads in the metal screw shell beginning at the plane of the outer edge 7.6.1.5 A fuseholder may employ a

47、female member of special design not necessarily of the screw shell type if it complies with the requirements in Clauses 7.6.1.3 and 8.7A, and if it has been found to be acceptable for the purpose by other appropriate tests, which may include temperature and short-circuit tests. This is generated tex

48、t for gtxt. FEBRUARY 28, 2007 NMX-J-009/4248/11-ANCE CSA C22.2 NO. 4248.11-07 UL 4248-11 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 7.7 Creepage and clearance 7.7.1 Creepage and clearance spacings of a plug fuseholder shall be as speci

49、ed in Table 7.7A, except spacings: a) between adjacent screw shells of Edison-base plug fuseholders that are protected by surrounding walls of insulating material; b) between parts of the upper-contactor rings of adjacent Type S plug fuseholders; and c) between such screw shells or upper-contact-ring parts and a metal cover plate shall not be less than 6.4 mm (0.250 in) if the depth of the rece

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1