ANSI UL 60335-2-89-2017 UL Standard for Safety Household and Similar Electrical Appliances C Safety C Part 2-89 Particular Requirements for Commercial Refrigerating Appliances with.pdf

上传人:registerpick115 文档编号:439346 上传时间:2018-11-14 格式:PDF 页数:103 大小:967.15KB
下载 相关 举报
ANSI UL 60335-2-89-2017 UL Standard for Safety Household and Similar Electrical Appliances C Safety C Part 2-89 Particular Requirements for Commercial Refrigerating Appliances with.pdf_第1页
第1页 / 共103页
ANSI UL 60335-2-89-2017 UL Standard for Safety Household and Similar Electrical Appliances C Safety C Part 2-89 Particular Requirements for Commercial Refrigerating Appliances with.pdf_第2页
第2页 / 共103页
ANSI UL 60335-2-89-2017 UL Standard for Safety Household and Similar Electrical Appliances C Safety C Part 2-89 Particular Requirements for Commercial Refrigerating Appliances with.pdf_第3页
第3页 / 共103页
ANSI UL 60335-2-89-2017 UL Standard for Safety Household and Similar Electrical Appliances C Safety C Part 2-89 Particular Requirements for Commercial Refrigerating Appliances with.pdf_第4页
第4页 / 共103页
ANSI UL 60335-2-89-2017 UL Standard for Safety Household and Similar Electrical Appliances C Safety C Part 2-89 Particular Requirements for Commercial Refrigerating Appliances with.pdf_第5页
第5页 / 共103页
亲,该文档总共103页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 60335-2-89 Household and Similar Electrical Appliances Safety Part 2-89: Particular Requirements for Commercial Refrigerating Appliances with an Incorporated or Remote Refrigerant Unit or Co

2、mpressor STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Household and Similar Electrical

3、 Appliances Safety Part 2-89: Particular Requirements for Commercial Refrigerating Appliances with an Incorporated or Remote Refrigerant Unit or Compressor, UL 60335-2-89 First Edition, Dated September 29, 2017 Summary of Topics This First edition of ANSI/UL 60335-2-89, the harmonized Standard for H

4、ousehold and Similar Electrical Appliances Safety Part 2-89: Particular Requirements for Commercial Refrigerating Appliances with an Incorporated or Remote Refrigerant Unit or Compressor, is based off of Edition 2 of IEC 60335-2-89 and its Amendment No. 1. As noted in the Commitment for Amendments s

5、tatement located on the back side of the title page, UL and CSA are committed to updating this harmonized standard jointly. The requirements are substantially in accordance with Proposal(s) on this subject dated February 24, 2017 and June 16, 2017. All rights reserved. No part of this publication ma

6、y be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to

7、, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use thi

8、s Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety

9、 agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. SEPT

10、EMBER 29, 2017 UL 60335-2-89 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 29, 2017 UL 60335-2-89 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM

11、UL CSA Group CAN/CSA-C22.2 No. 60335-2-89:17 First Edition (IEC 60335-2-89:2010+A1:2012, MOD) Underwriters Laboratories Inc. UL 60335-2-89 First Edition Household and Similar Electrical Appliances Safety Part 2-89: Particular Requirements for Commercial Refrigerating Appliances with an Incorporated

12、or Remote Refrigerant Unit or Compressor September 29, 2017 This national standard is based on IEC 60335-2-89, edition 2.1 (2012), which is based on the second edition (2010) and its amendment 1 (2012). ANSI/UL 60335-2-89-2017 Approved byUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTIO

13、N OR DISTRIBUTION WITHOUT PERMISSION FROM UL Commitment for Amendments This standard is issued jointly by the Canadian Standards Association (operating as “CSA Group”) and Underwriters Laboratories Inc. (UL). Comments or proposals for revisions on any part of the standard may be submitted to CSA Gro

14、up or UL at anytime. Revisions to this standard will be made only after processing according to the standards development procedures of CSA Group and UL. CSA Group and UL will issue revisions to this standard by means of a new edition or revised or additional pages bearing their date of issue. ISBN

15、978-1-4883-0761-4 2017 CSA Group All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher. This Standard is subject to review within ve years from the date of publication, and suggestions for its improvement will be refer

16、red to the appropriate committee. To submit a proposal for change, please send the following information to inquirescsagroup.org and include Proposal for change in the subject line: Standard designation (number); relevant clause, table, and/or gure number; wording of the proposed change; and rationa

17、le for the change. To purchase CSA Group Standards and related publications, visit CSA Groups Online Store at shop.csa.ca or call toll-free 1-800-463-6727 or 416-747-4044. Copyright 2017 Underwriters Laboratories Inc. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic c

18、opy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. This ANSI/UL Standard for Safety consists of the First Edition. The most recent designation of ANSI/UL 60335-2

19、-89 as an American National Standard (ANSI) occurred on September 29, 2017. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page (front and back), or the Preface. The National Difference Page and IEC Foreword are also excluded from the ANSI approval of IEC-base

20、d standards. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. To purchase UL Standards, visit ULs Standards Sales Site

21、at http:/ HowToOrder.aspx or call toll-free 1-888-853-3503.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS PREFACE 6 NATIONAL DIFFERENCES . 9 FOREWORD . 10 INTRODUCTION . 13 1 Scope 14 2 Normative references .15 3 Terms and denition

22、s 18 4 General requirement .21 5 General conditions for the tests 21 6 Classication 23 7 Marking and instructions 24 8 Protection against access to live parts 30 9 Starting of motor-operated appliances 30 10 Power input and current .31 11 Heating 31 12 Void .33 13 Leakage current and electric streng

23、th at operating temperature 33 14 Transient overvoltages 34 15 Moisture resistance .34 16 Leakage current and electric strength .35 17 Overload protection of transformers and associated circuits 35 18 Endurance .35 19 Abnormal operation .35 20 Stability and mechanical hazards .38 21 Mechanical stren

24、gth .39 22 Construction .40 23 Internal wiring 56 24 Components .56 25 Supply connection and external exible cords 58 26 Terminals for external conductors .59 27 Provision for earthing 59 28 Screws and connections .59 29 Clearances, creepage distances and solid insulation 59 30 Resistance to heat an

25、d re 60 31 Resistance to rusting 60 32 Radiation, toxicity and similar hazards .61 SEPTEMBER 29, 2017 CAN/CSA-C22.2 NO. 60335-2-89:17 UL 60335-2-89 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Annexes Annex C (normative) Ageing test on m

26、otors Annex D (normative) Thermal motor protectors Annex P (informative) Guidance for the application of this standard to appliances used in warm damp equable climates 5 General conditions for the tests 67 11 Heating 67 SEPTEMBER 29, 2017 CAN/CSA-C22.2 NO. 60335-2-89:17 UL 60335-2-89 4UL COPYRIGHTED

27、 MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Annex AA (normative) Locked-rotor test of fan motors Annex BB (normative) Non-sparking “n” electrical apparatus Annex DVA (normative) North American additional requirements Annex 101.DVA (normative) Suppleme

28、ntal requirements Annex 101.DVB (normative) MCA Marking Annex 101.DVC (normative) Accelerated aging tests Gaskets Annex 101.DVD (normative) Refrigerators and freezers intended for installation within a motor fuel dispensing facility Annex 101.DVE (normative) Factory assembled walk-in coolers Annex 1

29、01.DVF (normative) Refrigerating units Annex 101.DVG (normative) Evaluation of partial systems Annex 101.DVH (normative) Dispensing units Annex 101.DVI (informative) Informative guidance Annex 101.DVJ (normative) Pressure and fatigue test requirements 101.DVJ.1 General 94 101.DVJ.2 Pressure test val

30、ue determined under testing carried out in Clause 11 94 101.DVJ.3 Pressure test value determined under testing carried out in Clause 19 94 101.DVJ.4 Pressure test value determined under testing carried out under standstill conditions 95 101.DVJ.5 Fatigue test option for Clauses 101.DVJ.1 and 101.DVJ

31、.4.2 95 Annex 101.DVK (normative) Pressure regulating relief valve endurance test Bibliography SEPTEMBER 29, 2017 CAN/CSA-C22.2 NO. 60335-2-89:17 UL 60335-2-89 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL PREFACE This is the harmonized C

32、SA Group and UL standard for particular requirements for Commercial Refrigerating Appliances with an Incorporated or Remote Refrigerant Unit or Compressor. It is the rst edition of CAN/CSA-C22.2 No. 60335-2-89, and the rst edition of UL 60335-2-89. This harmonized standard is based on IEC Publicatio

33、n 60335-2-89: Edition 2.1, Household and Similar Electrical Appliances Safety Part 2-89: Particular Requirements for Commercial Refrigerating Appliances with an Incorporated or Remote Refrigerant Unit or Compressor, issued July 2012. IEC 60335-2-89 is copyrighted by the IEC. This harmonized Standard

34、 was prepared by CSA Group and Underwriters Laboratories Inc. (UL). The efforts and support of the commercial refrigerating appliance manufacturing industry are gratefully acknowledged. This standard is considered suitable for use for conformity assessment within the stated scope of the standard. Th

35、is Standard was reviewed by the CSA Subcommittee on Household Appliances for Refrigeration, under the jurisdiction of the CSA Technical Committee on Consumer and Commercial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the

36、CSA Technical Committee. This Standard was also reviewed and approved by ULs Standards Technical Panel for Commercial Refrigerators and Freezers, STP 471. This Standard has been approved as a National Standard of Canada by the Standards Council of Canada (SCC) and approved by the American National S

37、tandards Institute (ANSI) for publication as an American National Standard. Application of Standard Where reference is made to a specic number of samples to be tested, the specied number is to be considered a minimum quantity. Note: Although the intended primary application of this standard is state

38、d in its scope, it is important to note that it remains the responsibility of the users of the standard to judge its suitability for their particular purpose. CAN/CSA-C22.2 No. 60335-2-89 is to be used in conjunction with the second edition of CAN/CSA-C22.2 No. 60335-1:16. The requirements for Comme

39、rcial Refrigerating Appliances with an Incorporated or Remote Refrigerant Unit or Compressor are contained in this Part 2 Standard and CAN/CSA-C22.2 No. 60335-1:16. Requirements of this Part 2 Standard, where stated, amend the requirements of CAN/CSA-C22.2 No. 60335-1:16. Where a particular subclaus

40、e of CAN/CSA-C22.2 No. 60335-1:16 is not mentioned in CAN/CSA-C22.2 No. 60335-2-89, the CAN/CSA-C22.2 No. 60335-1:16 subclause applies. UL 60335-2-89 is to be used in conjunction with the sixth edition of UL 60335-1. The requirements for Commercial Refrigerating Appliances with an Incorporated or Re

41、mote Refrigerant Unit or Compressor are contained in this Part 2 Standard and UL 60335-1. Requirements of this Part 2 Standard, where stated, amend the requirements of UL 60335-1. Where a particular subclause of UL 60335-1 is not mentioned in UL 60335-2-89, the UL 60335-1 subclause applies. SEPTEMBE

42、R 29, 2017 CAN/CSA-C22.2 NO. 60335-2-89:17 UL 60335-2-89 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Level of Harmonization This standard adopts the IEC text with national differences. This standard is published as an equivalent standar

43、d for CSA and UL. An equivalent standard is a standard that is substantially the same in technical content, except as follows: a) Technical national differences are allowed for national differences resulting from conicts in codes and governmental regulations as well as those recognized as being in a

44、ccordance with NAFTA Article 905, for example, because of fundamental climatic, geographical, technological, or infrastructural factors, scientic justication, or the level of protection that the country considers appropriate. b) Presentation is word for word except for editorial changes that do not

45、alter the technical content of the standard. Examples of editorial changes include: 1) different font sizes, gure sizes, and table sizes; 2) minor variations in format, such as indentation and pagination; 3) font appearance (including the use of italic or bold text or uppercase or lowercase letters)

46、; 4) the use of a symbol (e.g., A or %) rather than the word (Ampere or percent), or the word rather than the symbol; 5) inclusion of inch-pound units for informational purposes; 6) corrections of misprints or typographical errors; 7) bilingual column headings or gure captions on a common table or g

47、ure in a bilingual edition; 8) change from rst-angle to third-angle drawing; 9) addition of a statement: “This is a rst-angle drawing”; and 10) substitution of a point (.) for a comma (,) as the decimal marker. All national differences from the IEC text are included in the CSA Group and UL versions

48、of the standard. While the technical content is the same in each organizations version, the format and presentation may differ. Reasons for Differences From IEC Differences from the IEC are being added in order to address safety and regulatory situations present in the US and Canada. SEPTEMBER 29, 2

49、017 CAN/CSA-C22.2 NO. 60335-2-89:17 UL 60335-2-89 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Interpretations The interpretation by the standards development organization of an identical or equivalent standard is based on the literal text to determine compliance with the standard in accordance with the procedural rules of the standards development organization. If more than one interpretation of

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1