ANSI UL 60384-14-2014 UL Standard for Safety Fixed Capacitors for Use in Electronic Equipment C Part 14 Sectional Specification Fixed Capacitors for Electromagnetic Interference Su.pdf

上传人:registerpick115 文档编号:439347 上传时间:2018-11-14 格式:PDF 页数:91 大小:1.59MB
下载 相关 举报
ANSI UL 60384-14-2014 UL Standard for Safety Fixed Capacitors for Use in Electronic Equipment C Part 14 Sectional Specification Fixed Capacitors for Electromagnetic Interference Su.pdf_第1页
第1页 / 共91页
ANSI UL 60384-14-2014 UL Standard for Safety Fixed Capacitors for Use in Electronic Equipment C Part 14 Sectional Specification Fixed Capacitors for Electromagnetic Interference Su.pdf_第2页
第2页 / 共91页
ANSI UL 60384-14-2014 UL Standard for Safety Fixed Capacitors for Use in Electronic Equipment C Part 14 Sectional Specification Fixed Capacitors for Electromagnetic Interference Su.pdf_第3页
第3页 / 共91页
ANSI UL 60384-14-2014 UL Standard for Safety Fixed Capacitors for Use in Electronic Equipment C Part 14 Sectional Specification Fixed Capacitors for Electromagnetic Interference Su.pdf_第4页
第4页 / 共91页
ANSI UL 60384-14-2014 UL Standard for Safety Fixed Capacitors for Use in Electronic Equipment C Part 14 Sectional Specification Fixed Capacitors for Electromagnetic Interference Su.pdf_第5页
第5页 / 共91页
亲,该文档总共91页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 60384-14 Fixed Capacitors for Use in Electronic Equipment Part 14: Sectional Specication: Fixed Capacitors for Electromagnetic Interference Suppression and Connection to the Supply Mains STA

2、NDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Fixed Capacitors for Use in Electronic Equipment Part 14: Sectional Spe

3、cication: Fixed Capacitors for Electromagnetic Interference Suppression and Connection to the Supply Mains, UL 60384-14 Second Edition, Dated July 11, 2014 Summary of Topics The revisions to the Standard for Safety for Fixed Capacitors for Use in Electronic Equipment Part 14: Sectional Specication:

4、Fixed Capacitors for Electromagnetic Interference Suppression and Connection to the Supply Mains, UL 6038414, are being issued to reect the latest ANSI approval date, and to incorporate the following changes in requirements: Removal of Figure 9DVD2 modication. Text that has been changed in any manne

5、r or impacted by ULs electronic publishing system is marked with a vertical line in the margin. The revised requirements are substantially in accordance with Proposal(s) on this subject dated April 28, 2017. All rights reserved. No part of this publication may be reproduced, stored in a retrieval sy

6、stem, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantabili

7、ty or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized U

8、L representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL

9、harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. JUNE 1, 2017 UL 60384-14 tr1UL COPYRIGHTED MA

10、TERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JUNE 1, 2017 UL 60384-14 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JULY 11, 2014 (Title Page Reprinted: June 1, 2017) 1 U

11、L 60384-14 Safety Requirements for Fixed Capacitors for Use in Electronic Equipment Part 14: Sectional Specication: Fixed Capacitors for Electromagnetic Interference Suppression and Connection to the Supply Mains First Edition April, 2009 Second Edition July 11, 2014 This ANSI/UL Standard for Safety

12、 consists of the Second Edition including revisions through June 1, 2017. The most recent designation of ANSI/UL 60384-14 as an American National Standard (ANSI) occurred on June 1, 2017. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or Preface. The Nat

13、ional Difference Page and IEC Foreword are also excluded from the ANSI approval of IEC-based standards. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Deve

14、lopment System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property o

15、f UL. COPYRIGHT 2017 UNDERWRITERS LABORATORIES INC. ANSI/UL 60384-14-2017UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JULY 11, 2014 UL 60384-14 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTR

16、IBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface (UL) 6 NATIONAL DIFFERENCES . 7 FOREWORD 8 1 General .10 1.1 Scope 10 1.2 Object 10 1.3 Normative references 10 1.4 Information to be given in a detail specication 11 1.5 Terms and denitions 13 1.6 Marking 21 1.7 Classication of Class X and Class Y

17、 capacitors 22 2 Preferred ratings and characteristics .26 2.1 Preferred characteristics 26 2.2 Preferred values of ratings 26 2.3 Requirements for sleeving, tape, tubing and wire insulation .28 3 Assessment procedures .28 3.1 Primary stage of manufacture .28 3.2 Structurally similar components .28

18、3.3 Certied records of released lots 28 3.4 Approval testing .28 3.5 Quality conformance inspection .39 4 Test and measurement procedures 42 4.1 Visual examination and check of dimensions 43 4.2 Electrical tests 44 4.3 Robustness of terminations .48 4.4 Resistance to soldering heat 49 4.5 Solderabil

19、ity 49 4.6 Rapid change of temperature .50 4.7 Vibration .50 4.8 Bump 51 4.9 Shock 52 4.10 Container sealing .53 4.11 Climatic sequence .53 4.12 Damp heat, steady state .55 4.13 IMPULSE VOLTAGE 56 4.14 Endurance .58 4.15 Charge and discharge .61 4.16 Radiofrequency characteristics 63 4.17 PASSIVE FL

20、AMMABILITY test .63 4.18 ACTIVE FLAMMABILITY test 64 4.19 Component solvent resistance (if applicable) .67 4.20 Solvent resistance of the marking .67 JULY 11, 2014 UL 60384-14 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Annex A (normati

21、ve) Circuit for the IMPULSE VOLTAGE test Annex B (normative) Circuit for the endurance test Annex C (normative) Circuit for the charge and discharge test Annex D (normative) Declaration of design (condential to the manufacturer and the certication body) Annex E (informative) Pulse test circuits Anne

22、x F (normative) Particular requirements for safety test of surface mounting capacitors F.1 General .76 F.2 Test and measurement procedures .76 Annex G (informative) Capacitance ageing of xed capacitors of ceramic dielectric, Class 2 G.1 Overview .79 G.2 Law of capacitance ageing 79 G.3 Capacitance m

23、easurements and capacitance tolerance 80 G.4 Special preconditioning .81 Annex H (normative) Use of safety approved a.c. rated capacitors in d.c. applications H.1 Overview .82 H.2 Background .82 H.3 Terms and denitions 82 H.4 Additional requirement for use of X- and Y-capacitors in d.c. applications

24、 .82 Annex I (normative) Humidity robustness grades for applications, where high stability under high humidity operating conditions is required I.1 Overview 84 I.2.1 Grade (I) robustness under humidity 84 I.2.2 Grade (II) robustness under high humidity .84 I.2.3 Grade (III) high robustness under hig

25、h humidity 85 I.3 Indication of humidity robustness grades 85 DECEMBER 5, 2016 UL 60384-14 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 5, 2016 UL 60384-14 5 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER

26、 REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Preface (UL) This UL Standard is based on IEC Publication 60384-14: Fourth Edition, Safety Requirements for Fixed Capacitors for Use in Electronic Equipment Part 14: Sectional Specication: Fixed Capacitors for Electromagnetic Interference Supp

27、ression and Connection to the Supply Mains. IEC publication 60384-14 is copyrighted by the IEC. This is the UL Standard for Safety for Fixed Capacitors for Use in Electronic Equipment Part 14: Sectional Specication: Fixed Capacitors for Electromagnetic Interference Suppression and Connection to the

28、Supply Mains. The text, gures and tables of IEC publication 60384-14, Safety Requirements for Fixed Capacitors for Use in Electronic Equipment Part 14: Sectional Specication: Fixed Capacitors for Electromagnetic Interference Suppression and Connection to the Supply Mains copyright June, 2013 are use

29、d in this Standard with the consent of the IEC and the American National Standards Institute (ANSI). The IEC copyrighted material has been reproduced with permission from ANSI. ANSI should be contacted regarding the reproduction of any portion of the IEC material. The IEC Foreword and Introduction a

30、re not a part of the requirements of this Standard but are included for information purposes only. Copies of IEC Publication 60384-14 may be purchased from ANSI, 11 West 42 nd Street, New York, New York, 10036, (212) 642-4900. Note Although the intended primary application of this Standard is stated

31、 in its Scope, it is important to note that it remains the responsibility of the users of the Standard to judge its suitability for their particular purpose. These materials are subject to copyright claims of IEC, ANSI, and UL. No part of this publication may be reproduced in any form, including an

32、electronic retrieval system, without the prior written permission of UL. All such requests pertaining to the ANSI/UL 60384-14 Standard should be submitted to UL. The previous version of UL 60384-14 included national differences to the following IEC requirements: Clauses 2.26, 2.3, 4.14.1, 4.17 and F

33、igure 9. These national differences were deleted in this version of UL 60384-14. JUNE 1, 2017 UL 60384-14 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NATIONAL DIFFERENCES There are ve types of National Differences as noted below. The di

34、fference type is noted on the rst line of the National Difference in the standard. The standard may not include all types of these National Differences. DR These are National Differences based on the national regulatory requirements. D1 These are National Differences which are based on basic safety

35、principles and requirements, elimination of which would compromise safety for consumers and users of products. D2 These are National Differences from IEC requirements based on existing safety practices. These requirements reect national safety practices, where empirical substantiation (for the IEC o

36、r national requirement) is not available or the text has not been included in the IEC standard. DC These are National Differences based on the component standards and will not be deleted until a particular component standard is harmonized with the IEC component standard. DE These are National Differ

37、ences based on editorial comments or corrections. Each national difference contains a description of what the national difference entails. Typically one of the following words is used to explain how the text of the national difference is to be applied to the base IEC text: Addition / Add - An additi

38、on entails adding a complete new numbered clause, subclause, table, gure, or annex. Addition is not meant to include adding select words to the base IEC text. Modication / Modify - A modication is an altering of the existing base IEC text such as the addition, replacement or deletion of certain word

39、s or the replacement of an entire clause, subclause, table, gure, or annex of the base IEC text. Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause, table, gure, or annex without any replacement text. JUNE 1, 2017 UL 60384-14 7UL COPYRIGHTED MATERIAL NOT

40、 AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTERNATIONAL ELECTROTECHNICAL COMMISSION FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT Part 14: Sectional Specication: Fixed Capacitors for Electromagnetic Interference Suppression and Connection to the Supply Mains

41、FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the

42、 electrical and electronic elds. To this end and in addition to other activities, IEC publishes International Standards, Technical Specications, Technical Reports, Publicly Available Specications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to tech

43、nical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and nongovernmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organi

44、zation for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical

45、committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publicatio

46、ns is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national

47、and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in

48、conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees f

49、or any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibi

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1