ANSI UL 608-2004 UL Standard for Safety Burglary Resistant Vault Doors and Modular Panels (Seventh Edition Reprint with Revisions Through and Including June 5 2017)《防盗储藏室门和预制墙板的安全性.pdf

上传人:towelfact221 文档编号:439385 上传时间:2018-11-14 格式:PDF 页数:19 大小:610.08KB
下载 相关 举报
ANSI UL 608-2004 UL Standard for Safety Burglary Resistant Vault Doors and Modular Panels (Seventh Edition Reprint with Revisions Through and Including June 5 2017)《防盗储藏室门和预制墙板的安全性.pdf_第1页
第1页 / 共19页
ANSI UL 608-2004 UL Standard for Safety Burglary Resistant Vault Doors and Modular Panels (Seventh Edition Reprint with Revisions Through and Including June 5 2017)《防盗储藏室门和预制墙板的安全性.pdf_第2页
第2页 / 共19页
ANSI UL 608-2004 UL Standard for Safety Burglary Resistant Vault Doors and Modular Panels (Seventh Edition Reprint with Revisions Through and Including June 5 2017)《防盗储藏室门和预制墙板的安全性.pdf_第3页
第3页 / 共19页
ANSI UL 608-2004 UL Standard for Safety Burglary Resistant Vault Doors and Modular Panels (Seventh Edition Reprint with Revisions Through and Including June 5 2017)《防盗储藏室门和预制墙板的安全性.pdf_第4页
第4页 / 共19页
ANSI UL 608-2004 UL Standard for Safety Burglary Resistant Vault Doors and Modular Panels (Seventh Edition Reprint with Revisions Through and Including June 5 2017)《防盗储藏室门和预制墙板的安全性.pdf_第5页
第5页 / 共19页
亲,该文档总共19页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 608 Burglary Resistant Vault Doors and Modular Panels STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGH

2、TED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Burglary Resistant Vault Doors and Modular Panels, UL 608 Seventh Edition, Dated November 30, 2004 Summary of Topics This revision of ANSI/UL 608 is being issued to update the t

3、itle page to reect reaffirmation of ANSI approval. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in the margin and are followed by an effective date note i

4、ndicating the date of publication or the date on which the changed requirement becomes effective. The requirements are substantially in accordance with Proposal(s) on this subject dated March 31, 2017. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,

5、or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or

6、tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL repr

7、esentative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmle

8、ss from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The following table lists the future effective date

9、s with the corresponding reference. JUNE 5, 2017 UL 608 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Future Effective Dates References The effective date for the revised requirement is to be determined. 8.3.1 JUNE 5, 2017 UL 608 tr2UL

10、COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMBER 30, 2004 (Title Page Reprinted: June 5, 2017) 1 UL 608 Standard for Burglary Resistant Vault Doors and Modular Panels The rst and second editions were titled Burglary Resistant Vault Door

11、s. First Edition April, 1980 Second Edition January, 1982 Third Edition July, 1982 Fourth Edition August, 1988 Fifth Edition September, 1994 Sixth Edition March, 1999 Seventh Edition November 30, 2004 This ANSI/UL Standard for Safety consists of the Seventh Edition including revisions through June 5

12、, 2017. The most recent designation of ANSI/UL 608 as a Reaffirmed American National Standard (ANS) occurred on June 5, 2017. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, and Title Page. Comments or proposals for revisions on any part of the Standard may be submit

13、ted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standa

14、rds and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2017 UNDERWRITERS LABORATORIES INC. ANSI/UL 608-2012 (R2017)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM U

15、L NOVEMBER 30, 2004 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 General 5 2.1 Components 5 2.2 Units of measurement .6 2.

16、3 Undated references .6 3 Glossary 6 CONSTRUCTION 4 Corrosion Protection .7 5 Locks .7 PERFORMANCE 6 General 8 7 Test Equipment .8 8 Attack Tests 8 8.1 General 8 8.2 Lock mechanism .9 8.3 Cutting an opening .9 8.4 Cutting locking bolts 9 MARKING 9 Details .9 APPENDIX A Standards for Components .A1 N

17、OVEMBER 30, 2004 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 31, 2012 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR

18、FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover vault doors and vault modular panels (for use in the construction of vault oors, walls, and ceilings) of the type intended for use in nancial institutions, commercial, industrial and mer

19、cantile properties, and the like, and that are relied upon to protect the contents from burglary attack. 1.2 These requirements are intended to establish the burglary resistant rating of vault doors and modular panels according to the length of time they withstand attack by common mechanical tools,

20、electric tools, cutting torches, or any combination of these means. The ratings based on the net working time to effect entry are as follows: a) Class M 1/4 hour. b) Class 1 1/2 hour. c) Class21hour. d) Class32hours. 1.3 These requirements do not cover attacks with the burning bar (thermal lance) or

21、 explosives. 2 General 2.1 Components 2.1.1 Except as indicated in 2.1.2, a component of a product covered by this standard shall comply with the requirements for that component. See Appendix A for a list of standards covering components used in the products covered by this standard. 2.1.2 A compone

22、nt is not required to comply with a specic requirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.1.3 A component shall be used in accordance with its

23、 rating established for the intended conditions of use. 2.1.4 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall

24、be used only under those specic conditions. NOVEMBER 30, 2004 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2.2 Units of measurement 2.2.1 Values stated without parentheses are th

25、e requirement. Values in parentheses are explanatory or approximate information. 2.3 Undated references 2.3.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. 3 Glossary 3.1 Fo

26、r the purpose of this standard the following denitions apply. 3.2 COMMON HAND TOOLS Chisels, punches, wrenches, screwdrivers, pliers, hammers, and sledges not exceeding the 8-pound (3.6 kg) size, and pry bars and ripping tools not exceeding 5 feet (1.52 m) in length. 3.3 CUTTING TORCH A heavy-duty,

27、commercially available oxy-fuel cutting torch. 3.4 ENTRY Opening the door or making a 96-square-inch (619-cm 2 ) opening entirely through the door or door frame or both, including the grouted-in portion within the frame, or through the modular panel or a seam joining two or more modular panels. 3.5

28、FLUXING ROD Low carbon steel or similar type material rods, such as concrete reinforcing rods, to aid in torch cutting. 3.6 HYDRAULIC TOOLS Portable electric or manually operated jacks, wedges, and similar pressure applying devices not exceeding 100,000 pounds (444,820 N) of force. 3.7 IMPACT TOOLS

29、Portable electric or pneumatic impact hammers and hammer drills, not exceeding the 1 inch (25.4 mm) chuck size. 3.8 NET WORKING TIME The time during which an attack is actively in progress on the sample, excluding the time required for test preparation, safety precautions, and delays. 3.9 96-SQUARE-

30、INCH OPENING A rectangular-shaped opening with the smallest dimension being 6 inches (152 mm), a circular opening 11.06 inches (281 mm) in diameter, or an isosceles right-triangle- shaped opening with a hypotenuse of 19.6 inches (497 mm). 3.10 PICKING TOOLS Common or stranded patterns that are not d

31、esigned for use against a specic model of vault door. 3.11 PORTABLE ELECTRIC DRILLS AND TOOLS Electric hand drills accommodating drill bits not larger than 1 inch (25.4 mm) and coring drills. 3.12 POWER SAWS Circular saws not exceeding 8 inches (203 mm) in diameter, hole saws not exceeding 12 inches

32、 (305 mm) in diameter, or reciprocating saws. 3.13 PRESSURE APPLYING DEVICES Portable drill presses, portable drilling jigs, or other types of drill-holding mechanisms. NOVEMBER 30, 2004 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER RE

33、PRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONSTRUCTION 4 Corrosion Protection 4.1 Iron and steel parts, other than bearings, and the like, shall be protected against corrosion by enameling, galvanizing, sherardizing, plating, or other means determined to be equivalent. Exception No. 1: T

34、his requirement does not apply to parts, such as washers, screws, bolts, and the like, if corrosion of such unprotected parts would not impair the intended operation of the unit. Exception No. 2: Parts made of stainless steel, polished or treated, if necessary, do not require additional protection a

35、gainst corrosion. Exception No. 3: This requirement does not apply to reinforcing elements used to strengthen concrete and the like. 4.2 The requirement in 4.1 applies to all enclosures of sheet steel or cast iron, and to all springs and other parts upon which intended mechanical operation or constr

36、uction depends. Bearing surfaces shall resist binding due to corrosion. 4.3 Metal shall not be used in combinations that cause galvanic action. Exception: If galvanic action does not result in impaired operation of construction of the product or impaired security, this requirement does not apply. 5

37、Locks 5.1 Each vault door shall be provided with: a) A combination lock classied as Group 1 or 1R complying with the Standard for Combination Locks, UL 768, or a high-security electronic lock, Type 1, complying with the requirements for high-security electronic locks; or b) A timelock complying with

38、 the Standard for Delayed-Action Timelocks, UL 887, and a combination lock classied as Group 1, 1R, or 2M, complying with UL 768; or c) A timelock complying with UL 887, and a high-security electronic lock, Type 1, complying with the requirements for high-security electronic locks. Exception: The do

39、or is not required to be shipped with the timelock mounted to it when the door is fully prepared for the mounting of the timelock and the timelock is shipped with the door in separate packaging. A prominent marking shall be attached to the door informing the installer of the door that the timelock s

40、hall be installed in order to provide the intended locking security. Instructions for the mounting of the timelock shall be shipped with the door and the timelock. NOVEMBER 30, 2004 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODU

41、CTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL PERFORMANCE 6 General 6.1 A single sample that is fully representative of a series of vault doors of similar design, size and construction, shall be submitted for test. 6.2 At least two or more modular vault panels shall be submitted to represent the

42、specied design of the vault and assembled to represent all seams used to construct the oor, walls and ceiling of the vault. 6.3 The selection of test samples shall be determined by a study of detailed dimensioned drawings of the construction and schedule of sizes, and specications of the steel and d

43、rill-resistant and torch-resistant metal or materials shall be furnished. 6.4 The door and seam clearances of the test sample shall represent the manufacturers maximum production tolerances. 7 Test Equipment 7.1 The test equipment shall include any common hand tools, picking tools, mechanical or por

44、table electric tools, grinding points carbide drills, pressure applying devices or mechanisms, abrasive cutting wheels, power saws, coring tools, impact tools, uxing rods, and oxy-fuel gas cutting torches. 7.2 The quantity of gas consumed (combined total oxygen and fuel gas) in any one test shall be

45、 limited as follows: a) Class M and 1 2000 ft 3 (56.6 m 3 ). b) Class 2 4000 ft 3 (113.3 m 3 ). c) Class 3 8000 ft 3 (226.5 m 3 ). 8 Attack Tests 8.1 General 8.1.1 The testing party, consisting of two skilled operators, may select any or all of the methods of attack and may sustain each attack for t

46、he full allotted time. The product shall resist the best method or combination of methods applied to a given point or area for the net working time specied. NOVEMBER 30, 2004 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION O

47、R DISTRIBUTION WITHOUT PERMISSION FROM UL 8.2 Lock mechanism 8.2.1 An attempt is to be made to penetrate through the door to the lock box, lug, carrying bar, or other parts of the mechanism, then to release the boltwork by punching, prying, picking, or cutting. 8.3 Cutting an opening 8.3.1 An attemp

48、t is to be made to cut an opening 96 square-inches (619 cm 2 ) entirely through the door, the door frame, vestibule, a modular panel, or at a seam joining two or more modular panels. 8.3.1 revised, effective date to be determined 8.4 Cutting locking bolts 8.4.1 An attempt is to be made to cut as man

49、y bolts as necessary to open the door. MARKING 9 Details 9.1 Each vault door or modular panel shall be legibly and permanently marked at a location that is visible after installation with the following information: a) Manufacturers or private labelers name or identifying symbol. b) Date of manufacture by week, month or quarter, and year (any of which may be abbreviated or in an established or otherwise traceable code or serial number). c) Model number or equivalent. 9.2 I

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1