ANSI UL 61730-2-2017 UL Standard for safety Photovoltaic (PV) Module Safety Qualification C Part 2 Requirements for Testing (First Edition).pdf

上传人:inwarn120 文档编号:439435 上传时间:2018-11-14 格式:PDF 页数:85 大小:1.88MB
下载 相关 举报
ANSI UL 61730-2-2017 UL Standard for safety Photovoltaic (PV) Module Safety Qualification C Part 2 Requirements for Testing (First Edition).pdf_第1页
第1页 / 共85页
ANSI UL 61730-2-2017 UL Standard for safety Photovoltaic (PV) Module Safety Qualification C Part 2 Requirements for Testing (First Edition).pdf_第2页
第2页 / 共85页
ANSI UL 61730-2-2017 UL Standard for safety Photovoltaic (PV) Module Safety Qualification C Part 2 Requirements for Testing (First Edition).pdf_第3页
第3页 / 共85页
ANSI UL 61730-2-2017 UL Standard for safety Photovoltaic (PV) Module Safety Qualification C Part 2 Requirements for Testing (First Edition).pdf_第4页
第4页 / 共85页
ANSI UL 61730-2-2017 UL Standard for safety Photovoltaic (PV) Module Safety Qualification C Part 2 Requirements for Testing (First Edition).pdf_第5页
第5页 / 共85页
亲,该文档总共85页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 61730-2 Photovoltaic (PV) Module Safety Qualication Part 2: Requirements for Testing STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOU

2、T PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Photovoltaic (PV) Module Safety Qualication Part 2: Requirements for Testing, UL 61730-2 First Edition, Dated December 4, 2017 Summary of Topics U

3、L 61730-2 is an adoption of IEC 61730-1, Photovoltaic (PV) Module Safety Qualication Part 2: Requirements for Testing (Second Edition, issued by the IEC August 2016). Please note that the National Difference document incorporates all of the U.S. national differences for UL 61730-2. The requirements

4、are substantially in accordance with Proposal(s) on this subject dated June 9, 2017. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior p

5、ermission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar

6、damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever ex

7、ceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) re

8、sulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. DECEMBER 4, 2017 UL 61730-2 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 4, 2017 UL 61730-2 tr

9、2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 4, 2017 1 UL 61730-2 Photovoltaic (PV) Module Safety Qualication Part 2: Requirements for Testing First Edition December 4, 2017 This ANSI/UL Standard for Safety

10、consists of the First Edition dated December 4, 2017. The most recent designation of ANSI/UL 61730-2 as an American National Standard (ANSI) occurred on December 4, 2017. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or Preface. The National Difference

11、Page and IEC Foreword are also excluded from the ANSI approval of IEC-based standards. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (C

12、SDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2

13、017 UNDERWRITERS LABORATORIES INC. ANSI/UL 61730-2-2017UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 4, 2017 UL 61730-2 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT

14、PERMISSION FROM UL CONTENTS PREFACE 6 NATIONAL DIFFERENCES .7 FOREWORD 8 1 Scope 11 2 Normative references.11 3 Terms and denitions 13 4 Test categories 13 4.1 General 13 4.2 Environmental stress tests14 4.3 General inspection 14 4.4 Electric shock hazard tests .15 4.5 Fire hazard tests 15 4.6 Mecha

15、nical stress tests 16 5 Classes and their necessary test procedures 16 6 Sampling .17 7 Test report 18 8 Testing .19 9 Pass criteria.21 10 Test procedures 21 10.1 General .21 10.2 Visual inspection MST 01 .21 10.3 Performance at STC MST 02 25 10.4 Maximum power determination MST 03 .25 10.5 Insulati

16、on thickness test MST 04 .26 10.6 Durability of markings MST 05 .26 10.7 Sharp edge test MST 06 27 10.8 Bypass diode functionality test MST 07 .27 10.9 Accessibility test MST 1127 10.10 Cut susceptibility test MST 12 29 10.11 Continuity test of equipotential bonding MST 13 30 10.12 Impulse voltage t

17、est MST 14 .32 10.13 Insulation test MST 16 .34 10.14 Wet leakage current test MST 17 .35 10.15 Temperature test MST 21 35 10.16 Hot-spot endurance test MST 22 39 10.17 Fire test MST 23 39 10.17DV.1 Introduction 40 10.17DV.2 Building-Integrated PV Modules 40 10.17DV.3 Building-attached photovoltaic

18、module.40 10.17DV.4 Fire Type Testing .40 10.18 Ignitability test MST 24.43 10.19 Bypass diode thermal test MST 25 47 10.20 Reverse current overload test MST 26 .48 10.21 Module breakage test MST 32 49 10.22 Screw connections test MST 33.50 10.23 Static mechanical load test MST 34 .55 10.24 Peel tes

19、t MST 35 .56 DECEMBER 4, 2017 UL 61730-2 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 10.25 Lap shear strength test MST 36.60 10.26 Materials creep test MST 3765 10.27 Robustness of terminations test MST 42 .66 10.28 Thermal cycling test

20、 MST 51 .66 10.29 Humidity freeze test MST 52 .67 10.30 Damp heat test MST 5367 10.31 UV test MST 54.67 10.32 Cold conditioning MST 55 67 10.33 Dry heat conditioning MST 56 68 Annex A (informative) Recommendations for testing of PV modules from production A.1 General .70 A.2 Module output power .70

21、A.3 Wet insulation test .70 A.4 Visual inspection .71 A.5 Bypass diodes .71 A.6 Continuity test of equipotential bonding .71 Annex DVA (Normative) Testing of PV modules from production Annex B (informative) Fire tests, spread-of-ame and burning-brand tests for PV modules B.1 General .75 B.2 Fire tes

22、t for PV modules based on ENV 1187 .75 B.2.1 General 75 B.2.2 External re exposure to roofs 76 B.2.3 Classication according to ISO 13501-5 76 B.3 Fire test for PV modules based on ANSI/UL 1703 .78 Annex DVB (Normative) Type tests for re performance characterization of modules independent of roof cov

23、erings DECEMBER 4, 2017 UL 61730-2 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 4, 2017 UL 61730-2 5 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL

24、PREFACE This UL Standard is based on IEC Publication IEC 61730-2: Second edition Photovoltaic (PV) Module Safety Qualication Part 2: Requirements for Testing. IEC publication IEC 61730-2 is copyrighted by the IEC. These materials are subject to copyright claims of IEC and UL. No part of this publica

25、tion may be reproduced in any form, including an electronic retrieval system, without the prior written permission of UL. All requests pertaining to the Photovoltaic (PV) Module Safety Qualication Part 2: Requirements for Testing, 61730-2, Standard should be submitted to UL. Note Although the intend

26、ed primary application of this Standard is stated in its Scope, it is important to note that it remains the responsibility of the users of the Standard to judge its suitability for their particular purpose. DECEMBER 4, 2017 UL 61730-2 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION

27、OR DISTRIBUTION WITHOUT PERMISSION FROM UL NATIONAL DIFFERENCES National Differences from the text of International Electrotechnical Commission (IEC) Publication IEC 61730-2 are indicated by notations (differences) and are presented in bold text. There are ve types of National Differences as noted b

28、elow. The difference type is noted on the rst line of the National Difference in the standard. The standard may not include all types of these National Differences. DR These are National Differences based on the national regulatory requirements. D1 These are National Differences which are based on b

29、asic safety principles and requirements, elimination of which would compromise safety for consumers and users of products. D2 These are National Differences from IEC requirements based on existing safety practices. These requirements reect national safety practices, where empirical substantiation (f

30、or the IEC or national requirement) is not available or the text has not been included in the IEC standard. DC These are National Differences based on the component standards and will not be deleted until a particular component standard is harmonized with the IEC component standard. DE These are Nat

31、ional Differences based on editorial comments or corrections. Each national difference contains a description of what the national difference entails. Typically one of the following words is used to explain how the text of the national difference is to be applied to the base IEC text: Addition / Add

32、 - An addition entails adding a complete new numbered clause, subclause, table, gure, or annex. Addition is not meant to include adding select words to the base IEC text. Modication / Modify - A modication is an altering of the existing base IEC text such as the addition, replacement or deletion of

33、certain words or the replacement of an entire clause, subclause, table, gure, or annex of the base IEC text. Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause, table, gure, or annex without any replacement text. DECEMBER 4, 2017 UL 61730-2 7UL COPYRIGHT

34、ED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTERNATIONAL ELECTROTECHNICAL COMMISSION PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION Part 2: Requirements for testing FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organ

35、ization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic elds. To this end and in addition to other activities, IE

36、C publishes International Standards, Technical Specications, Technical Reports, Publicly Available Specications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with ma

37、y participate in this preparatory work. International, governmental and nongovernmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreeme

38、nt between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Pub

39、lications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or

40、 for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corres

41、ponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certication bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any

42、 services carried out by independent certication bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC

43、National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attenti

44、on is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC

45、shall not be held responsible for identifying any or all such patent rights. International Standard IEC 61730-2 has been prepared by IEC technical committee 82: Solar photovoltaic energy systems. This second edition cancels and replaces the rst edition of IEC 61730-2, issued in 2004 and its amendmen

46、t 1 (2011), and constitutes a technical revision. This edition includes the following signicant technical changes with respect to the previous edition: DECEMBER 4, 2017 UL 61730-2 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL a) Rearrange

47、 test sequences. b) MST 01: Visual inspection: added nameplate requirement and modied pass criteria. c) Added sharp edge test MST 06. d) Added insulation thickness test MST 04. e) MST 11: Accessibility test: dened force for test nger. f) MST 12: Cut susceptibility test: dened blade radius for cut te

48、st. g) MST 14: removed preconditioning requirement TC200 from Figure 1. h) MST 15: Partial discharge test removed. i) Renamed dielectric breakdown test MST 16 to insulation test. j) MST 21: Temperature test: rewritten test procedure; removed short circuit mode; allow alternative indoor test method.

49、k) MST 23: Fire test: subclause rewritten; re test requirements related to national building codes; moved optional test description to informative annex. l) Added ignitability test MST 24. m) MST 26: Reverse current overload test: changed specication of wooden board. n) MST 32: Module breakage test: dened new dimensions of impactor to allow other lling compounds; consider variety of mounting techniques for glass breakage test; reduced impact height to only 300 mm; corrected diamet

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1