ARMY A-A-59893-2012 1 3 5-TRICHLOROBENZENE (TCB) CAS.pdf

上传人:proposalcash356 文档编号:440403 上传时间:2018-11-15 格式:PDF 页数:9 大小:233.08KB
下载 相关 举报
ARMY A-A-59893-2012 1 3 5-TRICHLOROBENZENE (TCB) CAS.pdf_第1页
第1页 / 共9页
ARMY A-A-59893-2012 1 3 5-TRICHLOROBENZENE (TCB) CAS.pdf_第2页
第2页 / 共9页
ARMY A-A-59893-2012 1 3 5-TRICHLOROBENZENE (TCB) CAS.pdf_第3页
第3页 / 共9页
ARMY A-A-59893-2012 1 3 5-TRICHLOROBENZENE (TCB) CAS.pdf_第4页
第4页 / 共9页
ARMY A-A-59893-2012 1 3 5-TRICHLOROBENZENE (TCB) CAS.pdf_第5页
第5页 / 共9页
亲,该文档总共9页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、 A-A-59893 17 October 2012 COMMERCIAL ITEM DESCRIPTION 1,3,5-TRICHLOROBENZENE (TCB), CAS # 108-70-3 The General Services Administration has authorized the use of this commercial item description, for all federal agencies. 1. SCOPE 1.1 Scope. This commercial item description covers 1,3,5-trichloroben

2、zene (TCB). 2. SALIENT CHARACTERISTICS 2.1 Material. The material shall be 1,3,5-trichlorobenzene (TCB) meeting the following requirements: a) Color: White to off-white b) Form: The TCB may be supplied as a cast solid in a suitable container or as a granulated, flaked, or pelletized material c) Comp

3、ound identification: FTIR spectral profile to correspond that of pure material d) Purity: 98% minimum, by HPLC or GC area count e) Insoluble Material: 0.2 wt% max. f) Melting point: 62C minimum 2.2 Workmanship: The best commercial practice shall be used in the manufacture of this product. Procedures

4、 and controls shall be employed to prevent product contamination. There shall be no contamination (such as dirt, paint chips, wood, etc.) that is obvious and readily observable. In addition, the TCB shall be free of contaminants which are hazardous, corrosive, reactive, or metallic. AMSC N/A FSC 681

5、0 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited INCH-POUND Comments, suggestions, or questions on this document should be addressed to: Commander, U.S. Army ARDEC, ATTN: RDAR-QES-E, Picatinny Arsenal, New Jersey 07806-5000 or e-mailed to ARDECSTDZNconus.army.mil. S

6、ince contact information can change, you may want to verify the currency of this information using ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59893 2 3. REGULATORY REQUIREMENTS. 3.1 Safety and

7、 Health Practices. This standard does not purport to address all of the safety concerns, if any, associated with the use of the TCB material. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and to determine the applicability of

8、regulatory limitations prior to use. 3.2 Manufacture Safety Data Statement. Manufacture Safety Data Statement shall be submitted in accordance with requirements as specified in the Code of Federal Regulation, Part 29-1910 (OSHA). (For shipment to foreign users, the Manufacture Safety Data Statement

9、may have to conform to the formatting and legislative requirements of the host country.) 4. QUALITY ASSURANCE PROVISIONS. 4.1 Product conformance. The product provided shall meet the salient characteristics of this Commercial Item Description. The Government reserves the right to require proof of su

10、ch conformance prior to the first delivery and thereafter as may be otherwise provided for under provisions of the contract. For TCB product which has been sold on the market for less than two years, the manufacturer shall have to demonstrate process stability and to verify product quality by submit

11、ting analysis data from the most recent 5 consecutive production batches. 4.2 Responsibility for inspection. Unless otherwise specified in the contract or purchase order, the supplier is responsible for the performance of inspections for the verification of all salient characteristics as specified i

12、n Section 2 of this CID. The supplier may use his own or any other facility suitable for the performance of the inspection requirements specified herein, unless otherwise specified in the contract or disapproved by the Government. The Government reserves the right to perform any inspections set fort

13、h in the CID where such inspections are deemed necessary to assure supplies and services conform to the prescribed requirements. 4.2.1 Bid sample submission. Unless otherwise specified, a sample of 100 grams of TCB shall be submitted for inspection and approval in accordance with the terms of the pr

14、ocurement contract. The sample will be subjected to any or all of the quality inspections listed in this CID for verification of compliance to any or all requirements listed in this CID. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59893 3 4.2

15、.2 Test and inspection results. The contractor shall provide a summary of product test results (or an appropriate form of document of analysis in accordance with acceptable industry practices) to verify conformance to the salient characteristics requirements. (See 2). The contractor shall maintain a

16、 traceable record of inspection test data adhering to general laboratory practices for future reference if required. 4.3 Sampling techniques and inspection procedures. When not specified in this CID, the TCB shall be inspected by using acceptable industry-wide sampling techniques and test procedures

17、 such as ASTM and ACS sampling and test procedures. Also, unless otherwise specified herein, all chemicals and reagents shall be ACS or Reagent Grade. Tests for High Performance Liquid Chromatography (HPLC) and the Fourier Transform Infrared Spectroscopy (FTIR) shall be performed as specified below.

18、 NOTE: The test description described below are not intended to be used as step-by-step laboratory procedures, rather they are intended to define the test methods used to obtain the required characteristics. The user should prepare their own laboratory procedures taking into consideration and comply

19、ing with all aspects of the following test method descriptions. In preparation of step-by-step laboratory procedures, the user should take into account safety precautions from the manufacturer, industry safety and health practices, and also determine the applicability of safety and environmental reg

20、ulatory limitations. The test descriptions below do not purport to address all the safety concerns, if any, associated with their use. It is the responsibility of the user of the procedure to establish appropriate safety and health practices and to determine the applicability of regulatory limitatio

21、ns prior to use. 4.3.1 Compound identification. A sample of TCB is given positive identification by an infrared scan from 4000 to 650 cm 4.3.1.1 Apparatus: A Perkin Elmer System One Fourier Transform Infrared (FTIR) spectrometer with a germanium lens and attenuated total reflectance (ATR) attachment

22、, or its equivalent. 4.3.1.2 Sample preparation: Use sufficient sample to cover the lens. 4.3.1.3 Results of examination. The spectral profile must correspond to the one shown below, Fig. 1. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59893 4

23、 FTIR - ATR SPECTRUM of 1,3,5-TCB 4000-650 cm-1Figure 1 4.3.2 TCB purity: The purity of the TCB shall be determined through High Performance Liquid Chromatography (HPLC) 4.3.2.1 Apparatus: A Waters Alliance HPLC with a UV-VIS detector, or its equivalent 4.3.2.2 Instrument parameters: (a) Column: Phe

24、nomenex Luna 3 micron, C8, 150 x 2.0 mm or its equivalent. (b) Mobile phase (HPLC Grade): actonitrile:HO/45:55, 0.3 ml/min, isocratic. (c) Injection volume: 10L (d) Wavelength: 280 nm (e) Retention time: 27 minutes (f) Run time: 35 minutes Note: times may vary with instrument type and column plumbin

25、g Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59893 5 4.3.2.3 Sample concentration: 1000 ppm in acetonitrile, HPLC or Analytical Reagent Grade. 4.3.2.4 Calculation: The calculation is made by adding together the counts from all the peaks with

26、 exception of the solvent front. The count of the TCB peak is then divided by the total count, times 100, to obtain the percentage purity of the TCB. See Fig. 2 below. Purity may also be calculated using a reference standard. The standard must have a certificate of analysis indicating purity of at l

27、east 99.0 %. The calculation is made by dividing the sample area count by the standard area count, then multiplying by the nominal value of the standard. HPLC 1,3,5-TCB Figure 2 4.3.3 TCB purity, alternate method. The purity of the TCB may be determined through Gas Chromatography (GC). Provided by I

28、HSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59893 6 4.3.3.1 Apparatus: Agilent 6890 Gas Chromatograph or equivalent, with thermal conductivity or mass detector. 4.3.3.2 Instrument parameters: (a) Column: DB 5 or equivalent, 30 m x 250 um, 0.25 film thickn

29、ess, or equivalent (b) Helium flow: 1 mL/min (c) Oven temp: 70 C initial, 2 min hold, ramp to 230 C 20 C/min, hold 10 min (d) Injection volume: 1uL (e) Injector temperature: 250 C (f) Detector temperature: 250 C (g) Retention time: 6 minutes Run time: 20 minutes Note: times may vary with instrument

30、type and column plumbing 4.3.3.3 Sample concentration: 3 mg/mL in methylene chloride, Analytical Reagent Grade. 4.3.3.4 Calculation: The calculation is made by adding together the counts from all the peaks with exception of the solvent front. The count of the TCB peak is then divided by the total co

31、unt, times 100, to obtain the percentage purity of the TCB. A correction is made for the material that is insoluble in methylene chloride. Chromatogram is shown below in Fig. 3. Purity may also be calculated using a reference standard. The standard must have a certificate of analysis indicating puri

32、ty of at least 99.0 %. The calculation is made by dividing the sample area count by standard area count, then multiplying by the nominal value of the standard. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59893 7 GC 1,3,5-TCB Figure 3 4.3.4 In

33、soluble material: A weighed sample of TCB is dissolved in methylene chloride and filtered through a tared glass filtering crucible. The crucible is reweighed and the weight gain is considered due to insoluble material. 4.3.4.1 Apparatus and reagents. (a) Filtering crucibles, 30 or 50 ml of volume, f

34、ine porosity fritted glass. (b) Standard laboratory apparatus to weigh the sample, dissolve it in 500 ml methylene chloride, effect an analytical transfer to the filtering crucible, and to wash, dry, and weigh the residue. (c) Methylene chloride, Analytical Reagent Grade. 4.3.4.2 Procedure. (a) Weig

35、h a 50-g sample to 0.1 mg into beaker capable of holding 500 ml methylene chloride. Add the solvent and stir until the sample is dissolved. Tare a filtering crucible and filter the solution through it using vacuum. Wash Provided by IHSNot for ResaleNo reproduction or networking permitted without lic

36、ense from IHS-,-,-A-A-59893 8 the contents of the crucible with the additional methylene chloride. Dry the crucible at 60C in an air-flow oven, cools, and weigh. (b) Calculate the percentage of methylene chloride insolubles as follows: % Insolubles = W2W3W1x100 Where W1= weight of sample in grams W2

37、= weight of crucible and residue in grams W3= weight of crucible in grams Correct the percentage purity of the TCB by subtracting insoluble percentage from the purity percentage as calculated in the equation above. 4.3.5 Melting point: 4.3.5.1 Apparatus and materials; Thomas Hoover Uni-Melt 6406H Ca

38、pillary Melting-Point Apparatus or equivalent, capillary tubes. 4.3.5.2 Procedure: Add to inch of TCB to capillary tube; place in oil bath. Adjust heating rate to manufacturers recommended setting. Observe onset and end melting point temperature. 5. PACKAGING. Preservation, packing, and marking shal

39、l be as specified in the contract or order (see 6.1.d). 6. NOTES. 6.1 Ordering data. Procurement documents should specify the following; a. Title, number, and date of this CID. b. Issue of Department of Defense Index of Standards and Specifications (DODISS) to be cited in this solicitation, and if r

40、equired, the specific issue of the individual documents referenced. c. Quantity required. d. Packing and marking requirements. 6. 2 Equivalent test method. Prior approval of the Contracting Officer is required for use of equivalent test methods. A description of the proposed method should be submitt

41、ed to through the Contracting Officer to: Commander, ATTN: RDAR-QAT-P, ARDEC, Picatinny Arsenal, NJ 07806-5000. This description should include, but not be limited to, the procedures used, the accuracy and precision of the method, test data to demonstrate the accuracy and precision and drawings of a

42、ny special equipment required. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59893 9 6. 3 Technical agency. ARDEC, Picatinny Arsenal, (RDAR-QAT-P), is the technical agency that is responsible for the preparation and revision of this Commercial

43、Item Description. This CID should not be revised without the expressed concurrence and approval from the Technical Agency. All correspondence to the Technical Agency should be submitted through the contracting officer to: Commander, ARDEC, ATTN: RDAR-QES-E, Picatinny Arsenal, NJ 07806-5000. Custodia

44、n: Preparing Activity: Army - AR Army - AR Navy - SH (Project 6810-2012-006) Air Force - 68 Review activity: Army EA, AV, MI, MR, TE Navy AS Air Force 03, 11 DLA GS GSA - FAS NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ARMY

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1