ARMY MIL-D-51559 (1)-1993 DECONTAMINATING APPARATUS PORTABLE 14 LITER M13 (PRACTICE)《M13(练习)14升便携式去污器》.pdf

上传人:inwarn120 文档编号:442505 上传时间:2018-11-15 格式:PDF 页数:3 大小:94.40KB
下载 相关 举报
ARMY MIL-D-51559 (1)-1993 DECONTAMINATING APPARATUS PORTABLE 14 LITER M13 (PRACTICE)《M13(练习)14升便携式去污器》.pdf_第1页
第1页 / 共3页
ARMY MIL-D-51559 (1)-1993 DECONTAMINATING APPARATUS PORTABLE 14 LITER M13 (PRACTICE)《M13(练习)14升便携式去污器》.pdf_第2页
第2页 / 共3页
ARMY MIL-D-51559 (1)-1993 DECONTAMINATING APPARATUS PORTABLE 14 LITER M13 (PRACTICE)《M13(练习)14升便携式去污器》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、MIL-D-51559 (1) H 99999Ob 1855770 44b H MIL-D-51559 (EA) AMENDMENT 1 16 March 1993 MILITARY SPECIFICATION DECONTAMINATING APPARATUS, PORTABLE, 14 LITER, M13 (PRACTICE) This amendment forms Q part of MIL-D-51559(EA), dated 10 October 1991, and is approved for use by the U.S. Army Edgewood Research, D

2、evelopment and Engineering Center, Department of the Army and is available for use by all Departments and Agencies of the Department of Defense. PAGE 2 2.1.1: O After list of Federal Specifications add the following: MILITARY MIL-P-15011 - Pallets, Material Handling, Wood Post Construction, 4-Way En

3、try” Under “STANDARDS, h.IILJTARy(: Add the following in sequence: “MIL-STD-129 - Marking For Shipment and Storage MIL-STD-147 - Palletized Unit Loads”. 2.1.2, Under “DRAWINGS”: Delete “5-51-610 - Palletization and Marking (Prac- tice) ” . AMSC NIA FSC 4230 DISTRIBUTION STATEMENT A. Approved for pub

4、lic release; distribution is unlimited. 1 of 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-D-51559 (1) m 9799906 1855771 382 m MIL-D-5 1 5 59 (EA) AMENDMENT 1 PAGE 3 3.4: Delete in its entirety and substitute the following: “3.4 Spray charact

5、eristics. With the plastic container filled with a glycerin and water solution, at room conditions the apparatus shall be capable of being primed with no more than 10 strokes of the pump piston. With the wand held horizontally a minimum of 4 feet above the outlet of the glycerinlwater filled plastic

6、 container, spray shall be projected a horizontal distance of at least 3 feet and no leakage shall occur when the pump is activated and tested in accordance with 4.4.6.1 .” 3.6: Delete in its entirety. 3.7: Renumber as “3.6”. PAGE 4 - 4.3.3: Delete “(see 6.4)”. PAGE 5 4.4.3: Delete “(see 6.4)” from

7、the title. PAGE 7 4.4.5(a), Minor 202, Under “REQUIREMENT PARAGRAPH”: Delete “3.7” and sub- stitute “3.6”. PAGE 8 4.4.5(b), Under DRAWLbJG NUMBER”: Delete “5-51-610”. PAGE 9 4.4.6: Delete “(see 6.4) from the title. 4.4.6.1 (a): Delete in its entirety and substitute the following: “(a) Prepare a solu

8、tion of 50 percent glycerin and water. Fill the empty plastic container (Drawing 5-51-598) with 14.0 (+OS or -0) liters of solution. Assemble the a 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-D-51559 (1) H 999990b 1855772 219 H MIL-D-5 1559

9、 A) AMENDMENT 1 hose, pump, wands, and brush and attach the hose to the filled plastic container in accor- dance with the operating instructions (Drawing 5-51-571) .” PAGE 10 5.3, lines 3 and 4: Delete “When required, the palletization unit load shall be marked in accordance with Drawing 5-5 1-610.”

10、 and substitute “When palletization is required, the palletized unit load shall be marked in accordance with MIL-STD-129. 5.4: Delete in its entirety and substitute the following: “5.4 Unitization. For level A and B packing, a uniform quantity of practice appara- tus, packed as specified in 5.2.1 an

11、d 5.2.2 shall be palletized in accordance with the load type I requirements of MIL-STD-147, using type I, class 1, style 1 or la, 4-way entry, MIL-P-15011 pallets. Each prepared load shall be bonded with primary and secondary straps in accordance with bonding methods C and D, and applicable storage

12、aids in accor- dance with MIL-STD-147. The pallet pattern shall be selected in accordance with appen- dix B of MIL-STD-147. Wood preservative is required.” PAGE 11 6.4: Delete in its entirety. 6.5: Delete in its entirety. 6.6: Renumber as “6.4”. 6.7: Renumber as “6.5”. Custodian: Army - EA Preparing activity: Amy - EA Project No. 4230-Al00 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 60871-3-2015 Shunt capacitors for AC power systems having a rated voltage above 1 000 V Protection of shunt capacitors and shunt capacitor banks《额定电压大于1000 V的.pdf BS PD IEC TS 60871-3-2015 Shunt capacitors for AC power systems having a rated voltage above 1 000 V Protection of shunt capacitors and shunt capacitor banks《额定电压大于1000 V的.pdf
  • BS PD IEC TS 61244-1-2014 Determination of long-term radiation ageing in polymers Techniques for monitoring diffusion-limited oxidation《聚合物长期辐射老化的测定 限制氧化扩散的监控技术》.pdf BS PD IEC TS 61244-1-2014 Determination of long-term radiation ageing in polymers Techniques for monitoring diffusion-limited oxidation《聚合物长期辐射老化的测定 限制氧化扩散的监控技术》.pdf
  • BS PD IEC TS 61244-2-2014 Determination of long-term radiation ageing in polymers Procedures for predicting ageing at low dose rates《聚合物长期辐射老化的测定 低剂量辐射老化预测程序》.pdf BS PD IEC TS 61244-2-2014 Determination of long-term radiation ageing in polymers Procedures for predicting ageing at low dose rates《聚合物长期辐射老化的测定 低剂量辐射老化预测程序》.pdf
  • BS PD IEC TS 61375-2-4-2017 Electronic railway equipment Train communication network (TCN) TCN application profile《轨道电子设备 列车通信网络(TCN) TCN应用程序配置文件》.pdf BS PD IEC TS 61375-2-4-2017 Electronic railway equipment Train communication network (TCN) TCN application profile《轨道电子设备 列车通信网络(TCN) TCN应用程序配置文件》.pdf
  • BS PD IEC TS 61400-26-3-2016 Wind energy generation systems Availability for wind power stations《风力发电系统 风力发电站的可用性》.pdf BS PD IEC TS 61400-26-3-2016 Wind energy generation systems Availability for wind power stations《风力发电系统 风力发电站的可用性》.pdf
  • BS PD IEC TS 61496-4-2-2014 Safety of machinery Electro-sensitive protective equipment Particular requirements for equipment using vision based protective devices (VBPD) A.pdf BS PD IEC TS 61496-4-2-2014 Safety of machinery Electro-sensitive protective equipment Particular requirements for equipment using vision based protective devices (VBPD) A.pdf
  • BS PD IEC TS 61496-4-3-2015 Safety of machinery Electro-sensitive protective equipment Particular requirements for equipment using vision based protective devices (VBPD) A.pdf BS PD IEC TS 61496-4-3-2015 Safety of machinery Electro-sensitive protective equipment Particular requirements for equipment using vision based protective devices (VBPD) A.pdf
  • BS PD IEC TS 61508-3-1-2016 Functional safety of electrical electronic programmable electronic safety-related systems Software requirements Reuse of pre-existing software .pdf BS PD IEC TS 61508-3-1-2016 Functional safety of electrical electronic programmable electronic safety-related systems Software requirements Reuse of pre-existing software .pdf
  • BS PD IEC TS 61586-2017 Estimation of the reliability of electrical connectors《电气连接器可靠性评定》.pdf BS PD IEC TS 61586-2017 Estimation of the reliability of electrical connectors《电气连接器可靠性评定》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ARMY

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1