ARMY MIL-DTL-12109 21 B-2011 SOLENOID ELECTRICAL CLASS 2 (MACHINE GUN) 7 62 MM 24 VOLT DC 8 AMP MAX.pdf

上传人:progressking105 文档编号:443281 上传时间:2018-11-15 格式:PDF 页数:7 大小:102.63KB
下载 相关 举报
ARMY MIL-DTL-12109 21 B-2011 SOLENOID ELECTRICAL CLASS 2 (MACHINE GUN) 7 62 MM 24 VOLT DC 8 AMP MAX.pdf_第1页
第1页 / 共7页
ARMY MIL-DTL-12109 21 B-2011 SOLENOID ELECTRICAL CLASS 2 (MACHINE GUN) 7 62 MM 24 VOLT DC 8 AMP MAX.pdf_第2页
第2页 / 共7页
ARMY MIL-DTL-12109 21 B-2011 SOLENOID ELECTRICAL CLASS 2 (MACHINE GUN) 7 62 MM 24 VOLT DC 8 AMP MAX.pdf_第3页
第3页 / 共7页
ARMY MIL-DTL-12109 21 B-2011 SOLENOID ELECTRICAL CLASS 2 (MACHINE GUN) 7 62 MM 24 VOLT DC 8 AMP MAX.pdf_第4页
第4页 / 共7页
ARMY MIL-DTL-12109 21 B-2011 SOLENOID ELECTRICAL CLASS 2 (MACHINE GUN) 7 62 MM 24 VOLT DC 8 AMP MAX.pdf_第5页
第5页 / 共7页
亲,该文档总共7页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、 AMSC N/A FSC 5945 INCH-POUND MIL-DTL-12109/21B 11 January 2011 SUPERSEDING MIL-DTL-12109/21A 20 August 1998 DETAIL SPECIFICATION SHEET SOLENOID, ELECTRICAL; CLASS 2 (MACHINE GUN) 7.62 MM, 24 VOLT DC, 8 AMP MAX This specification is approved for use by all Departments and Agencies of the Department

2、of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-12109. APPLICABLE DOCUMENTS: Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent speci

3、fied herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-DTL-12109 - Solenoid, Electrical; Gun-Firing Mechanisms, General Specification For (Copies of these documents are available from https:/ass

4、ist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this specification

5、 to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation or contract. DRAWINGS 7792103 - Gasket 7792104 - Cable Assembly 75020922 - Connector Assembly Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

6、MIL-DTL-12109/21B 2 (Copies of these drawings are available from DAMI_STANDARDIZATIONconus.army.mil or U.S. Army RDECOM, Tank Automotive Research, Development and Engineering Center, ATTN: RDTA-EN/STND/TRANS MS #268, 6501 E. 11 Mile Road, Warren, MI 48397-5000.) Non-Government publications. The foll

7、owing documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. AEROSPACE INDUSTRIES ASSOCIATION (AIA) NASM20995 - Wire, Safety or Lock NASM24677 - Screw, Cap, Socket Head, Hexagon

8、, Drilled Alloy Steel (UNC-3A) NASM33540 - Safety Wiring and Cotter Pinning, General Practices For (Copies of these documents are available from http:/www.aia-aerospace.org or from Aerospace Industry Association, 1250 Eye Street, N.W., Suite 1200, Washington, D.C. 20005-3924.) AMERICAN NATIONAL STAN

9、DARDS INSTITUTE (ANSI) ANSI J STD 004,005,006 - Flux, Soldering, Liquid, Paste Flux, Solder Paste, and Solder-Paste Flux; General Specification For (Copies of these documents are available from www.ansi.org or ANSI Customer Service Department, 25 W. 43rd Street, 4th Floor, New York, NY 10036.) ASTM

10、INTERNATIONAL ASTM D412 - Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers Tension ASTM D429 - Standard Test Methods for Rubber Property Adhesion to Rigid Substrates ASTM D430 - Standard Test Methods for Rubber Deterioration Dynamic Fatigue ASTM D2000 - Standard Classificatio

11、n System for Rubber Products in Automotive Applications (Copies of these documents are available from www.astm.org or ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA, 19428-2959) REQUIREMENTS: Requirements for submission of first article shall be as specified in the con

12、tract. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-12109/21B 3 Stroke shall be 0.165 to 0.247 inches (in.) (0.42 to 0.63 centimeters (cm). Weight shall not exceed 2.25 pounds (lb) (1 kilogram (kg). Solenoid shall functionally operate agai

13、nst the static forces specified in figure 1, at 20 and 30 volts direct current (Vdc). The current shall not exceed 8 amperes maximum. 0102030400.000 0.050 0.100 0.150 0.200Air g a p - in.Min. force-lb.FIGURE 1. Static force - air gap curve. Solenoid shall meet the static force air gap curve shown in

14、 figure 1. Solenoid shall be capable of firing 10 000 rounds. Solenoid shall withstand a dielectric withstanding voltage potential of 1000 volts root mean square. A leakage current of 100 micro-amperes max is permitted. VERIFICATION: The first article shall be submitted for inspection in accordance

15、with contract requirements. The first article shall be tested in accordance with the tests specified herein and the testing provisions of MIL-DTL-12109. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-12109/21B 4 a. The stroke test shall be p

16、erformed during functional (operating) test. b. Weight shall be confirmed by any approved method. c. Testing for dielectric withstanding voltage shall as follows: Test voltage of 1000 volts root mean square at 60 Hertz (Hz) in frequency and shall approximate, as closely as possible, a true sine wave

17、 in form. The voltage shall be applied between coil terminal and ground metal parts for at least 60 seconds. Test voltage shall be raised from zero to 60 Hz in frequency at a rate of approximately 500 volts per second. NOTES: PART OR IDENTIFYING NUMBERS (PIN): M12109/21-1 (Former part number 7791685

18、 with weapon designation M60C) M12109/21-2 (Former part number 75F20924 with weapon designation M60E2) CHANGES FROM PREVIOUS ISSUE: The margins of this specification sheet are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only

19、and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Provided by

20、IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-12109/21B 5 .39R - .03 SP H ER I C A L .59 D A T U M 2 PL A C ES I N SC R I B E 1/8 HI G H , PA R T N O , MFR I D EN T A N D 24 V D C , B O O T MA T ER I A L SE E N O T E 4 C O F P U SH ROD L 2.80 D I A - .

21、01 1.64 - .03 1.398 .014 .820 .008 1.255 MA X . WI R E N A SM20995 A S R EQ U I R E D ( WI R E S H A LL B E I N ST A LL ED I N ACCORDAN CE W I T H N A SM33540 D O U B LE T WI ST MET H O D 4 - SC R EW N A SM 24677 - 6 .305 - .005 .180 - .005 .21 0 - .036 DE - EN ER G I ZE D .182 - .004 1.675 R EF .14

22、 - .03 45 2 PL A C ES .019 + .01 0 2 PL A C ES 2.444 R EF 1.451 D I A R EF 2.01 D I A - .02 G A SK ET - 7792103 FIGURE 2. Solenoid characteristics. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-12109/21B 6 FIGRE 2. Solenoid characteristics

23、- Continued. NOTES: C A B LEA S SE MBL Y7792104M 1 2 1 0 9 /2 1 - 1V I E W A - A W I T H C O N NE C T OR , GA S K E T ,4 SC R E W S, & L O C K W I R E R E M O V E D . SH O W I N G A S SY .O F G R O U N D W I R E . 4 8 0 . 0 0 3A . A SS E M B L E GR O UN D W I R E T H R O U GH H O L E F R O M I NS I

24、DE , S T AK E ( C R I M P W I R E I N P L A C E . )B . S O L D E R I N G M A T L : AN S I J - ST D- 0 0 4 , - 0 0 5 , - 0 0 6. 0 4 5 D I A + . 0 1 0. 2 0 D E PT H O F H O L E. 2 5 0 . 0 0 3BB. 2 0 + . 0 1V I E W B BW I R ED R I L L PO I N TPE R M I S SI B L EAAC O N N E C T O R A SS Y7 5 0 2 0 9 2 2

25、M121 09/ 21- 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-12109/21B 7 1. This drawing is for interface and envelope requirements and is not intended to limit design. 2. Dimensions are in inches. Unless otherwise specified, tolerances are

26、.010 on decimals, 2 on angular dimensions. 3. REF = Reference 4. The solenoid boot shall be made per the following properties: ASTM D2000 M2BC 614 B13 C32 F17 Z1 Z2 Z3 Z1 = H2 (38) IAW ASTM D430 METHOD B Z2 = 350% MAX. ULTIMATE ELONGATION IAW ASTM D412 DIE C Z3 = K24, 3.5 KN/M WIDTH IAW ASTM D429 ME

27、THOD B, 100 C FIGURE 2. Solenoid characteristics - Continued. Custodians: Preparing Activity: Army - AT Army - AT Navy - OS Air Force - 85 (Project 5945-2011-004) Review Activities: Army - AR, EA Navy - MC Air Force - 99 DLA - CC NOTE: The activities listed above were interested in this document as

28、of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-