1、INCH -POUNDMIL -DTL -52876D4 August 1997SUPERSEDINGMIL -C -0052876C(ME)11 July 1986 andMIL -C -52876B28 August 1980DETAIL SPECIFICATIONCABINETS, MONITOR, CY -7359/FSS -9(V)CY -7360/FSS -9(V), AND CY -7361/FSS -9(V)Inactive for new design after 4 August 1997.This specification is approved for use by

2、all Departments and Agencies ofthe Department of Defense.1. SCOPE1.1 Scope. This specification covers three types of monitor cabinets withintegral power supplies and mounting facilities with interface connections forthe status and alarm monitor modules. The cabinets are components of theJoint -Servi

3、ces Interior Intrusion Detection System (J -SIIDS).1.2 Classification. Monitor cabinets are of the following types, asspecified (see 6.2):Type A - One Zone Monitor Cabinet, CY -7359/FSS -9(V).Type B - Five Zone Monitor Cabinet, CY -7360/FSS -9(V).Type C - Twenty -five Zone Monitor Cabinet, CY -7361/

4、FSS -9(V).2. APPLICABLE DOCUMENTS2.1 General. The documents listed in this section are specified insections 3 and 4 of this specification. This section does not includedocuments cited in other sections of this specification or recommended foradditional information or as examples. While every effort

5、has been made toensure the completeness of this list, document users are cautioned that theymust meet all specified requirements documents cited in sections 3 and 4 ofthis specification, whether or not they are listed.Beneficial comments (recommendations, additions, deletions) and any pertinentdata

6、which may be of use in improving this document should be addressed to: USArmy CECOM, ATTN: AMSEL -LC -IEW -D -ED, 10115 Gridley Rd, Suite 228, Ft Belvoir,VA 22060 -5849 by using the Standardization Document Improvement Proposal ( DDForm 1426) appearing at the end of this document or by letter.AMSC N

7、/A FSC 6350DISTRIBUTION STATEMENT A. Approved for public release; distribution isunlimited.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL -DTL -52876D22.2 Government documents.2.2.1 Standards and handbooks. The following standards and handbooks

8、forma part of this document to the extent specified herein. Unless otherwisespecified, the issues of these documents are those listed in the issue of theDepartment of Defense Index of Specifications and Standards (DoDISS) andsupplement thereto cited in the solicitation (see 6.2).STANDARDSDEPARTMENT

9、OF DEFENSEMIL -STD -130 - Identification Marking of US Military Property.MIL -STD -889 - Dissimilar Metals.HANDBOOKSDEPARTMENT OF DEFENSEMIL -HDBK -454 - General Guidelines for Electronic Equipment.MIL -HDBK -781 - Reliability Test Methods, Plans and Environmentsfor Engineering Development, Qualific

10、ation andProduction.(Unless otherwise indicated, copies of the above standards and handbooks areavailable from the Standardization Document Order Desk, 700 Robbins Avenue,Building 4D, Philadelphia, PA 19111 -5094.)2.2.2 Government drawings. The following Government drawings form a partof this docume

11、nt to the extent specified herein. Unless otherwise specified,the issues are those cited in the solicitation.DRAWINGSMETA13220E3900 - Cabinet, Monitor, 1 Zone, CY -7359/FSS -9(V).TA13220E3901 - Power Supply, 1 Zone Monitor.TA13220E3902 - Signal Module Assembly.TA13220E4000 - Cabinet, Monitor, 5 Zone

12、 , CY -7360/FSS -9(V).TA13220E4001 - Power Supply, 5 Zone Monitor.TA13220E4100 - Cabinet, Monitor, 25 Zone, CY -7361/FSS -9(V).TA13220E4101 - Power Supply, 25 Zone Monitor.(Copies of drawings required by contractors in connection with specificacquisition functions should be obtained from: US Army CE

13、COM, IEWSDirectorate, ATTN: AMSEL -LC -IEW -D -CE, 10115 Gridley Rd, Suite 228, FtBelvoir, VA 22060 -5849.)2.3 Non -Government publications. The following documents form a part ofthis document to the extent specified herein. Unless otherwise specified, theissues of the documents which are DoD adopte

14、d are those listed in the issue ofthe DoDISS cited in the solicitation. Unless otherwise specified, the issuesof documents not listed in the DoDISS are the issues of the documents cited inthe solicitation (see 6.2).AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)ASQC Z1.4 - Sampling Procedures and Table

15、s for Inspection byAttributes.ISO 10012 -1 - Quality Assurance Requirements for Measuring Equ ipment. Part 1: Metrological confirmation system for measuringequipment.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL -DTL -52876D3(Application for co

16、pies should be addressed to the: American NationalStandards Institute (ANSI), 11 West 42nd Street, New York, NY 10036.)AMERICAN WELDING SOCIETY (AWS)D9.1 - Welding of Sheet Metal.(Application for copies should be addressed to: American Welding Society,550 NW LeJeune Rd, PO Box 351040, Miami, FL 3313

17、5.)2.4 Order of precedence. In the event of a conflict between the text ofthis document and the references cited herein, the text of this document takesprecedence. Nothing in this document, however, supersedes applicable laws andregulations unless a specific exemption has been obtained.3. REQUIREMEN

18、TS3.1 Description. The 1 zone, 5 zone, and 25 zone monitor cabinets shall bein accordance with TA13220E3900, TA13220E4000, and TA13220E4100, respectively,and as specified herein.3.1.1 Major components. The major components of the monitor cabinets shallbe as follows:a. Signal modul e assembly: TA1322

19、0E3902.b. Power supply: TA13220E3901, TA13220E4001, and TA13220E4101 for the 1,5, and 25 zone monitor cabinets respectively.When specified (see 6.2), any of the major components listed above shall befurnished separately.3.1.2 Drawings. The drawings forming a part of this specification are endproduct

20、 drawings. No deviation from the prescribed dimensions or tolerancesis permissible without prior approval of the contracting officer. Wheretolerances could cumulatively result in incorrect fits, the contractor shallprovide tolerances within those prescribed on the drawings to ensure correctfit, asse

21、mbly and operation of the monitor cabinet. Any data (e.g., shopdrawings, layouts, flow sheets, processing procedures, etc.) prepared by thecontractor or obtained from a vendor to support fabrication and manufacture ofthe production item shall be made available, upon request, for inspection bythe con

22、tracting officer or designated representative.3.2 First article. When specified (see 6.2), a sample shall be subjectedto first article inspection in accordance with 4.2.3.3 Material. Material shall be as specified herein and on the applicabledrawings. Materials not specified shall be selected by the

23、 contractor andshall be subject to all provisions of this specification.3.3.1 Material deterioration prevention and control. The monitor cabinetsshall be fabricated from compatible materials, inherently corrosion resistantor treated to provide protection against the various forms of corrosion anddet

24、erioration that may be encountered in any of the applicable operating andstorage environments to which the monitor cabinet may be exposed.3.3.2 Dissimilar metals. Dissimilar metals shall not be used in intimatecontact with each other unless protected against galvanic corrosion.Dissimilar metals and

25、methods of protection are defined and detailed inMIL -STD -889.3.3.3 Recycled, recovered, or environmentally preferable materials.Recycled, recovered, or environmentally preferable materials should be used tothe maximum extent possible provided that the material meets or exceeds theoperational and m

26、aintenance requirements and promotes economicallyProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL -DTL -52876D4advantageous life cycle costs. Used, rebuilt or remanufactured components,pieces and parts shall not be incorporated in the monitor cabi

27、nets.3.4 Environmental conditions. When tested as specified in 4.4.2.7, themonitor cabinets and major components, when furnished separately, shallwithstand individual environmental conditions specified herein, orcombinations thereof, without damage (see 6.3.2), performance degradation, ormalfunction

28、.3.4.1 Operational.a. Temperature range of -20 to +150 F.b. Humidity up to 95 percent relative.3.4.2 Non -operational condition and storage.a. Temperature range of -30 to +165 F.b. Humidity up to 95 percent relative.c. Shock: bench handling (major components only), equipment notoperating.3.5 Detaile

29、d technical requirements. The monitor cabinets and majorcomponents when furnished separately shall perform as specified herein underany of the operating test conditions specified herein.3.5.1 Wiring. Monitor cabinet internal wiring and wiring harnesses shallbe in accordance with the wire list on the

30、 applicable top assembly drawing(TA13220E3900, TA13220E4000, TA13220E4100). Transmission line bracketscontaining lightning and EMI suppression components shall be in accordancewith applicable top assembly drawings.3.5.2 Signal module assembly. The signal module assembly shall contain anaudible signa

31、ling device and the monitor cabinet alternating current (ac)power status indicator lamps.3.5.2.1 Audible signaling device. When actuated, the signaling deviceshall sound at a frequency of 2900 500 Hertz (Hz) and an amplitude not lessthan 60 decibels ( db) referenced to 0.0002 microbars sound pressur

32、e level at adistance of 10 feet on -axis, using “A” frequency weighting. The signal deviceshall sound whenever less than 1 volt direct current ( Vdc) is being applied toterminal board 1, terminal 1 (TB1 -1), referenced to ground, of the signalmodule. It shall also sound whenever the ac power status

33、indicator lamps areflashing (see 3.5.2.2). The audible signaling device shall be silent whenboth of the following conditions exist: a voltage of 4 to 5 Vdc is applied toTB1 -1; the ac power status indicator lamps are continuously on or off (notflashing).3.5.2.2 Monitor cabinet ac power status indica

34、tor lamps. When the monitorcabinet is operating on external 117 (+8, -7) volts ac ( Vac) power, the acpower status indicator lamps shall be continuously lit. When the monitor unitis operating on standby power, the ac power status indicator lamps shall becontinuously off. When the external ac power t

35、o the monitor cabinet isremoved for a period of 3 0.5 seconds or when ac power is re -applied to themonitor cabinet after having been removed, the lamps shall begin to flash at afrequency of 4 0.5 Hz. When the “LAMP TEST/ACKNOWLEDGE” switch ismomentarily set to “ACKNOWLEDGE”, the flashing lamps shal

36、l go to continuouslyoff if the ac power is not present at the time of acknowledge, or tocontinuously lit if the ac power has been restored at the time of acknowledge.Actuation of the switch to “ACKNOWLEDGE” shall at no time prohibit the receiptof any power status change from resulting in the operati

37、on described above.Actuation of the switch to the “LAMP TEST” position shall cause both lamps tobe continuously lit while the switch is actuated.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL -DTL -52876D53.5.3 Primary power supply. The primary

38、power supply shall operate asspecified herein from 110 to 125 volts, 48 to 62 Hz ac power. The powersupply shall provide a 20 1 Vdc regulated output voltage, a 22.5 3.5 voltsac ( Vac) output voltage, and an unregulated dc voltage as specified herein tomaintain a standby battery supply on trickle cha

39、rge. The power supply shallalso provide, at the battery terminals TB2 -2 to TB2 -1, a fast charge voltagewhich shall function as specified herein. The trickle charge voltage shallvary as a function of the applied loads and ambient temperature in accordancewith table I and the Appendix A test procedu

40、res. The fast charge voltageoutput shall be capable of supplying up to the maximum current specified intable II. The fast charge mode shall be initiated when the voltage at thebattery terminals falls to 24.0 0.3 Vdc (fast charge threshold voltage) forthe 1 and 5 zone and 26.0 0.3 Vdc for the 25 zone

41、 power supply at a roomambient temperature of 77 5 F. For temperatures outside this temperaturerange, the fast charge threshold voltage tolerance shall be 1 Vdc. Thetrickle charge mode shall be restored when the battery terminal voltage rises2 0.5 volts above the fast charge threshold voltage and sh

42、all exist wheneverthe battery terminal voltage is above the fast charge threshold voltage,provided fast charge operation has not been initiated. The power supply shallalso conform to the current output, line regulation, load regulation andripple voltage requirements specified in table II. A power of

43、f/on switchshall be provided which in the “OFF” position shall disconnect ac power andthe standby battery power from the power supply circuitry. With the powerswitch in the “ON” position, a loss of input ac power shall cause the powersupply to automatically operate from the standby battery supply wi

44、thout falsealarm, incorrect status indication or other impairments of function. With abattery (batteries) or equivalent standby supply capable of providing therequired current at 24 Vdc, the power supply shall continue to provide theregulated 20 Vdc output specified. The twenty -five zone power supp

45、ly shallhave a thermal overload switch (thermostat) in the battery fast charge circuitwhich shall open when the switch temperature rises to 150 5 F and close whenthe temperature falls to 130 6 F.3.6 Burn -in. Each monitor cabinet (power supply component only) and powersupply when furnished separatel

46、y shall be subjected to an eight -hour burn -into reduce the number of infant mortality failures (see 4.4.2.4).TABLE I. Charging voltage as function of loads and temperatures.PowerSupplyTypeApplied Loads Voltage: TB2-2 to TB2-1 (Vdc)TB3 -1 toTB3 -7TB3 -2 toTB3 -7TB2 -2 toTB2 -177 5 F -20 F +150 F1 Z

47、one no load no load no load 27.9 .3 30.2 .7 25.6 .71 Zone 20K ohms 80 ohms 270 ohms 27.0 .5 29.8 .8 25.2 .85 Zone no load no load no load 28.2 .3 30.8 .7 26.6 .75 Zone 20K ohms 16 ohms 150 ohms 26.4 .8 29.0 1.0 24.8 1.025 Zone no load no load no load 29.4 .8 32.8 1.0 27.0 1.025 Zone 20K ohms 3.2 ohm

48、s no load 27.7 .3 31.0 .8 25.4 .8Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL -DTL -52876D6TABLE II. Power supply general requirements.Characteristic 1 Zone 5 Zone 25 ZoneMaximum currentTB3 -2 to TB3 -7 0.25 amperes (A) 1.25 A 6.25 ATB3 -1 to

49、TB3 -7 1.4 mA ac 1.4 mA ac 1.4 Ma acTB2 -2 to TB2 -1(trickle charge)0.25 A 0.300 A 0.750 ATB2 -2 to TB2 -1(fast charge)2 A 4A 8ALine RegulationTB3 -2 to TB3 -7 0.5 % 0.5 % 0.5 %TB3 -1 to TB3 -7 10 % 10 % 10 %TB2 -2 to TB2 -1 1.5 % 1.5 % 1.5 %Load RegulationTB3 -2 to TB3 -7 1 % 1 % 1 %TB3 -1 to TB3 -7 5 % 5 % 5 %Ripple ContentTB3 -2 to TB3 -7(periodic b. Each power supply, whether as a com