ARMY MIL-DTL-53126 6 A-2012 POWER DISTRIBUTION ILLUMINATION SYSTEMS ELECTRICAL UNIVERSAL ADAPTER [Superseded ARMY MIL-E-53126 REINST NOTICE 3 ARMY MIL-E-53126 CANC NOTICE 2 ARMY MI.pdf

上传人:deputyduring120 文档编号:444374 上传时间:2018-11-15 格式:PDF 页数:4 大小:69.89KB
下载 相关 举报
ARMY MIL-DTL-53126 6 A-2012 POWER DISTRIBUTION ILLUMINATION SYSTEMS ELECTRICAL UNIVERSAL ADAPTER [Superseded ARMY MIL-E-53126 REINST NOTICE 3 ARMY MIL-E-53126 CANC NOTICE 2 ARMY MI.pdf_第1页
第1页 / 共4页
ARMY MIL-DTL-53126 6 A-2012 POWER DISTRIBUTION ILLUMINATION SYSTEMS ELECTRICAL UNIVERSAL ADAPTER [Superseded ARMY MIL-E-53126 REINST NOTICE 3 ARMY MIL-E-53126 CANC NOTICE 2 ARMY MI.pdf_第2页
第2页 / 共4页
ARMY MIL-DTL-53126 6 A-2012 POWER DISTRIBUTION ILLUMINATION SYSTEMS ELECTRICAL UNIVERSAL ADAPTER [Superseded ARMY MIL-E-53126 REINST NOTICE 3 ARMY MIL-E-53126 CANC NOTICE 2 ARMY MI.pdf_第3页
第3页 / 共4页
ARMY MIL-DTL-53126 6 A-2012 POWER DISTRIBUTION ILLUMINATION SYSTEMS ELECTRICAL UNIVERSAL ADAPTER [Superseded ARMY MIL-E-53126 REINST NOTICE 3 ARMY MIL-E-53126 CANC NOTICE 2 ARMY MI.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 PAGE 1 OF 4 AMSC N/A FSC 6150 Distribution Statement A. Approved for public release, distribution is unlimited. INCH-POUND MIL-DTL-53126/6A 16 October 2012 SUPERSEDING MIL-E-53126(ME) 20 April 1992 DETAIL SPECIFICATION SHEET POWER DISTRIBUTION, ILLUMINATION SYSTEMS, ELECTRICAL UNIVERSAL ADAPTER Thi

2、s specification is approved for use within US Army Research Development and Engineering Command, Communications and Electronics Research and Development Center, Product Realization Directorate, Department of the Army and is available for use by all Departments and Agencies of the Department of Defen

3、se. The requirement for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-53126. 1 SCOPE 1.1 Scope. This specification sheet covers the detail requirements for the Power Distribution Illumination Systems Electrical (PDISE), Type VI, model: Universal Adapter

4、, NSN: 5975-01-247-4791. 2 APPLICABLE DOCUMENTS 2.1 Drawings. The following Government drawings form a part of this specification sheet to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. DRAWING# NOMENCLATURE DRAWING # NOMENCLATURE CECOM & PM-

5、MEP Drawings - Cage Code: 97403 and 30554 13227E6201 Special Universal Adapter 40/60 Amp, 3 Phase 13227E6208 Connector Assembly, Special Universal Adapter 13208E5820 Terminal, Load Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-53126/6A PAGE

6、 2 OF 4 (Copies of drawings required by contractors in connection with specific acquisition functions should be obtained from: PROJECT MANAGER-MOBILE ELECTRIC POWER, 5850 Delafield Road, Bldg 324 FT BELVOIR VA 22060-5809.) 3 REQUIREMENTS 3.1 Requirements. The Universal Adapter, Type VI, PDISE shall

7、be a self-contained, free-standing, man portable unit. The adapter shall connect electrical equipment without military standard connectors to the electrical power distribution equipment, as specified herein. The Universal Adapter consists of a box with a 5-pin, 3-phase 40/60 amp input connector and

8、five terminals. The box includes an insulated wrench for tightening/loosening the terminals. Figure 1. Universal Adapter 3.2 Design. The Universal Adapter shall be IAW TA13227E6201 and as specified herein. 3.2.1 Dimensions. The Universal Adapter shall not be greater than the following dimensions: Le

9、ngth (Inches) Width (Inches) Height (Inches) 21.00 16.00 16.50 3.2.2 Weight. The Universal Adapter shall weigh no more than 20 pounds. 3.2.3 Universal Adapter inputs. The Universal Adapter shall have a three phase input capable of handling 60 A/P. 3.2.3.1 Input Connector. The Universal Adapter shall

10、 have a 60 ampere, three phase, male, input receptacle IAW 13227E6208. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-53126/6A PAGE 3 OF 4 3.2.4 Universal Adapter PDISE outputs The Universal Adapter shall have 5 output terminals IAW 13208E58

11、20. 3.2.5 This specification sheet had no superseding “base”. The original publication of this specification was a performance specification that was used in-house by CR4. Since this specification is now a detailed military specification, this specification sheet is deemed necessary to capture the u

12、nique characteristics desired in the end item. 3.2.6 Changes from previous issues: Marginal notations are not used in this revision to identify changes with respect to the previous issue because this detail specification sheet although a part of the base document, was not published because it was a

13、document with limited circulation and coordination that was used essentially by CR4. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-53126/6A PAGE 4 OF 4 Concluding Material Custodian: Preparing Activity: Army - CR4 Army - CR4 (Project 6150-2

14、012-015) Review Activities: DLA-GS Note: The activities listed above were interested in this document as of the date of this document. Since organization and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-