1、Comments, suggestions, or questions on this document should be addressed to U.S. Army RDECOM, Tank Automotive Research, Development and Engineering Center, ATTN: RDTA-EN/STND/TRANS MS #268, 6501 E. 11 Mile Road, Warren, MI 48397-5000 or emailed to DAMI_STANDARDIZATIONconus.army.mil. Since contact in
2、formation can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil/online/. AMSC N/A FSC 2920 NOT MEASUREMENT SENSITIVE MIL-DTL-62062E(AT) 17 June 2010 SUPERSEDING MIL-DTL-62062D(AT) 4 September 1998 DETAIL SPECIFICATI
3、ON BLOWER, GENERATOR COOLING: 28 VOLT DC This specification is approved for use by the U.S. Army Tank-automotive and Armaments Command, Department of the Army, and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers one typ
4、e of 28 volt (V) direct current (dc) blower designed for use in combination with a 300 ampere (A) generator on military tracked vehicles. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include d
5、ocuments cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirement documents cited in sections 3 and 4 of
6、 this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents
7、 are those cited in the solicitation or contract (see 6.2). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL62062E 2 DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-23827 - Grease, Aircraft and Instrument, Gear and Actuator Screw. MIL-DTL-53022 -
8、 Primer, Epoxy Coating, Corrosion Inhibiting, Lead and Chromate Free. MIL-DTL-53030 - Primer Coatings, Epoxy, Water Reducible, Lead and Chromate Free. MIL-DTL-53039 - Coating, Aliphatic Polyurethane, Single Component, Chemical Agent Resistant MIL-DTL-64159 - Camouflage Coating, Water Dispersible Ali
9、phatic Polyurethane, Chemical Agent Resistant DEPARTMENT OF DEFENSE STANDARDS MIL-STD-202 - Test Methods for Electronic and Electrical Component Parts (see 4.4.1). MIL-STD-461 - Requirements for the Control of Electromagnetic Interference Emissions and Susceptibility. MIL-STD-810 - Environmental Eng
10、ineering Considerations and Laboratory Tests. (Unless otherwise indicated, copies of the above specifications and standards are available from the Document Automation and Production Service, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094 or https:/assist.daps.dla.mil/quicksearch/) 2.2.
11、2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6
12、.2). TACOM DRAWINGS 10898759 - Blower, Electrical Rotating Equipment. (Copies of these documents are available from dami_standardizationconus.army.mil or U.S. Army RDECOM, Tank Automotive Research Development, and Engineering Center, ATTN RDTA-EN/STND/TRANS, MS #268, 6501 E 11 Mile Road, Warren, MI
13、48397-5000) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). Provided by IHSNot for ResaleNo reproduction or netwo
14、rking permitted without license from IHS-,-,-MIL-DTL62062E 3 AIR MOVEMENT and (b) other discarded material, including solid, liquid, semisolid, or contained gaseous material resulting from industrial commercial, mining, and agricultural operations, and from community activities. It does not include
15、solid or dissolved material in domestic sewage, or solid or dissolved material in irrigation return flows or industrial discharges which are point sources subject to permits under byproduct material as defined by the Atomic Energy Act of 1954 (42 U.S.C. 2011 et seq.) (Source: Federal Acquisition Reg
16、ulations, section 23.402). 6.4 Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in the
17、se notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. 6.5 Subject term (key word) listing. Airflow Corrosion resistance Dielectric strength Elec
18、tromagnetic compatibility Fungus resistance Interchangeability Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL62062E 14 Custodian: Preparing Activity: Army AT Army - AT Review Activity: (Project 2920-2010-003) DLA - CC NOTE: The activities li
19、sted above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST database at https:/assist.daps.dla.mil/online/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-