1、MIL-F-l4452A(MU) 30 November 1967 SUPERSEDING MIL-F-l4452(CrnlC) 21 December 1956 MI LI TARY SPEC I I CAT I ON FILTER UN IT, GAS-PARTICULATE, HOSPITAL SIX-MAN, 12 CFM, M7A1 1, SCOPE 1 . 1 This specification covers one type of hospital filter unit. 2, APPLICABLE DOCUMENTS 2.1 Government documents. Th
2、e following documents of the issue in effect on the date of invitation for bids or request for proposal form a part of this specification to the extent specified herein. SPECIFICATIONS FEDERAL N N-P-530 QQ-S-78 1 P PP- B-601 PPP-0-636 MILITARY MIL-P-116 MI L- B- 1 2 1 MIL-P-130 MIL-P-14604 MI L-T- 1
3、4605 MI L-P-5 1 070 - -_ -. - - -I. - Plywood, Flat Panel, - Steel Strapping, Flat. - Box, Wood; Cleated-Plywood. - Box, Fiberboard. - Preservation, Methods of. - Barrier Material, Greaseproofed, Waterproofed, FI ex bl e . - Paper, Wrapping, Laminated and Creped. - Paper, Glassine, - Transformer Uni
4、t. - Purifier, Air, M2A2. FSC 4240 . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARDS MILITARY MIL-STD-105 MIL-STD-129 - Sampling Procedures and Tables for Inspection - Marking for Shipment and Storage, by Attributes. DRAW IN GS US ARMY MUNI
5、TIONS COMMAND D L5-66- 273 D 150-2- 1 - Filter Unit, Gas-Particulate, Hospital, Six-Man, 12 CFM, - Marking Diagram for Shipping Containers. M7A1 . (Copies of specifications, standards, drawings, and publications required by suppl ers in connection with specific procurement functions should be obtain
6、ed from the procuring activity or as directed by the contracting officer,) 2.2 Other publications. The following document forms a part of this specification to the extent specified herein. Unless otherwise indicated, the issue in effect on the date of invitation for bids or request for proposal shal
7、l apply. U NI F ORM CLASS IF ICATI ON COMMI TTEE Uniform Freight Classification (Application for copies of these ratings, rules and regulations should be addressed to Uniform Classification Committee, 202 Union Station, 516 West Jackson Boulevard, Chicago, Illinois 606060) 3. REQUIREMENTS 3.1 Materi
8、als and components. 3.1 1 Materials. All materials cited on Drawing DE-66-273 or on the subsidiary drawings shall conform to the specifications listed thereon or to the specific characteristic set forth on the drawings. 3.1.2 Components. All components of the headpiece shall conform to the specifica
9、tions and drawings listed on Drawing DL5-66- 273 and subsidiary drawings. J 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-I- - MIL-F-LVV52A V2 7779906 02323V7 O .I! MIL-F- 14452 A(MU) 3, Manufacture and assembly. The components of the filter unit
10、 shall be manufactured and assembled in accordance with their respective assembly drawings which are listed on DL5-66-273. 3.3 Workmanship. The filter unit shall be free from damage such as bent, chipped or burred metal parts and cracked, kinked or torn rubber parts, and foreign matter (dirt, grease
11、, oil or viscous material). 4. QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection. 4.1 . 1 Suppliers responsibility. Unless otherwise spec Fied in the contract or purchase order, the supplier is responsible for the performance of all inspection requirements as specified herein, Except as
12、 otherwise specified, the suppl er may utilize his own facilities or any commercial laboratory acceptable to the Government. The Government reserves the right to perform any of the inspections set forth in the specification where such inspections are deemed necessary to assure suppl es and services
13、conform to prescribed requirements. 4,1.2 .Objective evidence, The supplier shall provide objective evidence acceptable to the contracting officer that the requirements of 3.1 and section 5 for which specific inspection has not been provided in this specification have been satisfied. 4.2 Reaular mod
14、uction. 4.2,1 Lotting. A lot shall consist of the filter units produced by one manu- facturer, at one plant, from the same materials, under essentially the same manufacturing conditions. However, no more than one lot of air purifiers shall be represented in any one lot of finished filter units. 4.2.
15、2 Sampling for examination. Sampling shall be conducted in accordance with MIL-STD-105. 4.2,3 Inspection. 4.2.3,1 For examination. Filter units shall be examined and tested in accord- ance with the classification of defects and MIL-STD-105. .- . - - . - I- - . . - 3 Provided by IHSNot for ResaleNo r
16、eproduction or networking permitted without license from IHS-,-,-I- DIL-F-L4452A 112 7799706 02321118 2 . M I L -F - 1 445 2A (MU) 4.2.3.2 Classification of defects. (a) (Dwg DE-66-273). Categories Defects Cri ti cal : None defined . Major: 1 o1 1 02 1 03 AQL 1 .O percent defective Component missing
17、 Component incorrectly assembled Workmanship (3.3) 5. PREPARATION FOR DELIVERY 5.1 Cleaning and drying. The filter unit and its components shall be cleaned in accordance with method C-1 of MIL-P-116 and dried in accordance with any of the drying methods listed in MIL-P-116. 5.2 e. 5.2.1 Unit preserv
18、ation and packaging. 5.2.1.1 Hose assemblies. Fittings attached to hose assemblies shall be cushion- wrapped with greaseproof carrier material conforming io iype II, grade A, class 2 of MIL-B-121 or wrapping paper conforming to type II of MIL-P-130, The wrap shall be secured in place by tying or tap
19、ing. 5.2.1.2 Accessory kit. Washer, machine screws, wood screws, and nuts shall be packed in accordance with method ICI of MIL-P-116. 5.2.1.3 .Technical publications and drawings. Technical publications and drawings shall be packaged in accordance with method IC3 of MIL-P-116. 5.2.1.4 Headpiece and
20、carrier assembly. Each headpiece shall be folded as specified on Drawing (3-70-30 and placed in its carrierr To prevent adhesion, glassine paper conforming to MIL-P-14604 shall be used between folds of the headpiece and components. 4 Provided by IHSNot for ResaleNo reproduction or networking permitt
21、ed without license from IHS-,-,-. MIL-F-34452A 42 m 7979706 0232347 4 111; MIL-F-l4452A(MU) 5.2.2 Intermediate packaging. 5.2.2.1 hose assembly. The hose assembly (M5) consisting of two each hose assemblies Drawing C5-66-269 and plug and socket Y-fitting, the - accessory kit, and the technical publi
22、cation; and drawings, processed as specified in 5.2.1.1, 5.2.1.2 and 5.2.1.3, shall be packaged in a style RSC, type SF, class weather-resistant, grade W5s fiberboard box conforming to PPP-B-636, having approximate inside dimensions of 12-1/4 by 10-1/4 by 3-1/4 inches, The box shall be closed and se
23、aled in accordance with appli- cable requirements in the appendix of the box specification. 5.2.2.2 Hose assembly. The hose assembly (M4) consisting of two each hose assemblies Drawing (3-66-269 and one each hose assembly Drawing C5-66-230, processed as specified in 5.2.1 . 1 shall be packaged in a
24、style RSC, type SF, class weather-resistant, grade W5s fiberboard box conforming to PPP-B-636, having approximate inside dimensions of 12-1/4 by 10-1/4 by 5 inches. 5.2.2.3 Headpiece and carrier assembly. The headpiece and carrier assembly processed as specified in 5.2.1 o 4shall be packaged in a st
25、yle RSC, type SF, class weather-resistant, grade W5a fiberboard box which has approxi- mate inside dimensions of 12-1/4 by 10-1/4 by 5 inches and conforms to PPP-B-636, 5.2.2.4 Purifier, air, M2A2, The air purifier shall be packed in accordance with the level A requirements specified in MIL-P-51070.
26、 5.2.2.5 Transformer unit. The transformer unit shall be packed in accordance with the level A requirements specified in MIL-T-14605, 5.3 Packing. Level shall be as specified (see 6,2), 5.3.1 Level A. The filter unit, consisting of items preserved and packaged as specified in 5.2, shall be packed in
27、 a style A or B cleated plywood box c6n- forming to PPP-B-601. The plywood used in the construction of the boxes shall conform to group A of NN-P-530 or type I, grade 3 or 4 of CS-35. Plywood shall not have continuous holes or openings extending through the entire panel from face to back. The box sh
28、all be closed and strapped in accordance with the appendix to PPP-B-601. Strapping shall conform to type I, class B of QQ-S-781 . 5,3.2 Level Co The filter unit, preserved and packaged as specified in 5.2 shall be packeato insure carrier acceptance and safe delivery to the first domestic destination
29、, The containen shal I be in compliance with Freight Classification 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-14452A 42 7777706 0232150 O E MI L-F-l4452A(MU) rules or the regulations of other common carriers applicable to the mode of tr
30、ans- portation , 5.4 Marking. In addition to any special markings required by the contract or order, unit and intermediate packages shall be marked in accordance with MIL-STD- 129. Shipping containers shall be marked in accordance with Drawing D150-2-1 (Marking diagram for shipping container,) 6. NO
31、TES 6.1 Intended use. The filter unit covered by this specification is used to remove toxic gases and aerosols from the air and to supply purified air to six or fewer bed- ridden hospitatl patients suffering from wounds of the face, head or neck. 6.2 Ordering data. Procurement documents should speci
32、fy the title, number, date of this specification and level of packaging and packing required. 6.3 Component specifications. Purifier, Air, M2A2 - MIL-P-51070 Precleaner, Air Purifier, M1A1 - MI L-P-50085 Centrifugal Fan and Motor Assembly, 12 CFM - MIL-C-50084 Separator, Dust - MI L-S-50087 Filter,
33、Particulate, 12 CFM, M13 - MIL-F-52011 Filter, Gas, 12 CFM, M12A1 - MIL-F-14512 Transformer Unit - MIL-T-14605 Headpiece, Hospital Col lective Protector, M13A1 - MIL-H-51182 Valve, Outlet, C-19 - MIL-V-51195 Clamps, Wire, Gas Mask - MI L-C- 10083 Hose; For Filter Units - MI L-H- 14506 Carrier, Hospi
34、tal Col lective Protector, Ml2 - MIL-C-14041 6,4 International interest, Certain provisions of this specification are the subiect of international standardization agreement ABCA-ARMY-STD-154, When amendment, revision, or cancellation of this specification is proposed which will affect or violate .-
35、6 Y Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-14452A 42 W 7777906 0232151 2 . _. . MI L-F- 1 4452A( MU) the international agreement concerned, the preparing activity wil I take appro- priate reconciliation action through international sta
36、ndardization channels including departmental standardization offices, if required. Custodian: Preparing activity Army - MU (EA) Project No. 4240-A352 Army - MU International interest (see Section 6.4) l- -. . . -. . - - 7 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-