ARMY MIL-F-44402-1990 FINISHING SECTION MODULAR PRINTING SYSTEM《模数印刷系统精整工段》.pdf

上传人:confusegate185 文档编号:444641 上传时间:2018-11-15 格式:PDF 页数:12 大小:224.87KB
下载 相关 举报
ARMY MIL-F-44402-1990 FINISHING SECTION MODULAR PRINTING SYSTEM《模数印刷系统精整工段》.pdf_第1页
第1页 / 共12页
ARMY MIL-F-44402-1990 FINISHING SECTION MODULAR PRINTING SYSTEM《模数印刷系统精整工段》.pdf_第2页
第2页 / 共12页
ARMY MIL-F-44402-1990 FINISHING SECTION MODULAR PRINTING SYSTEM《模数印刷系统精整工段》.pdf_第3页
第3页 / 共12页
ARMY MIL-F-44402-1990 FINISHING SECTION MODULAR PRINTING SYSTEM《模数印刷系统精整工段》.pdf_第4页
第4页 / 共12页
ARMY MIL-F-44402-1990 FINISHING SECTION MODULAR PRINTING SYSTEM《模数印刷系统精整工段》.pdf_第5页
第5页 / 共12页
亲,该文档总共12页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、MILITARYFINISHING SECTION,INCH-POUNDMIL-F-44402(GL)16 February 1990SPECIFICATIONMODULAR PRINTING SYSTEMThis specification is approved for use by the Natick Research, Development, andEngineering Center, Department of the Army, and is available for use by allDepartments and Agencies of the Department

2、of Defense.1. SCOPE1.1 Scope. This specification covers the finishing section of the ModularPrinting System (see 6.1).2. APPLICABLE DOCUMENTS2.1 Government Documents.2.1.1 Specifications, standards, and handbooks. The following specifi-cations, standards, and handbooks form a part of this document t

3、o the extentspecified herein. Unless otherwise specified, the issues of these documents arethose listed in the issue of the Department of Defense Index of Specificationsand Standards (DODISS) and supplement thereto, cited in the solicitation (see6.2).Beneficial comments (recommendations, additions,

4、deletions) and anypertinent data which may be of use in improving this document should beaddressed to: U.S. Army Natick Research, Development, and EngineeringCenter, Natick, MA 01760-5014 by using the self-addressed StandardizationDocument Improvement Proposal (DD Form 1426) appearing at the end of

5、thisdocument or by letter.1 tAMSC N/A FSC 3610DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-44402(GL)SPECIFICATIONSMILITARYMIL-D-3464 - Desiccants, Activated, Ba

6、gged, Packaging Use andStatic DehumidificationMIL-S-44195 - Shelter, Tactical, Expandable, Two-SideSTANDARDS .MILITARYMIL-STD-105 - Sampling Procedures and Tables for Inspectionby Attributes(Unless otherwise indicated, copies of the federal and military specifica-tions, standards, and handbooks are

7、available from the Standardization DocumentsOrder Desk, Bldg. 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094. )2.1.2 Other Government documents, drawings, and publications. The followingother Government documents, drawings, and publications form a part of thisdocument to the extent specified he

8、rein. Unless otherwise specified, the issuesare those cited in the solicitation.Department of the Army Technical ManualsTM 5-3610-294-13&P - Operators Unit and Intermediate Direct SupportMaintenance Manual including Repair Parts and Special Tools List forModular Printing System, Module C - Finishing

9、 Section(Copies of the Army Technical Manuals are available from the U.S. AGPublications Center, 1655 Woodson Road, St. Louis, MO 63144.)DRAWINGSUs. ARMY NATICK RESEARCH, DEVELOPMENT, AND ENGINEERING CENTER5-13-46995-13-47335-13-47635-13-49935-13-50015-13-50105-13-50255-1.3-50265-13-5029Finishing Sh

10、elter Arrangement24,000 BTU Heat Pump36,000 BTU Heat PumpPaper CutterStencil, Center of GravityModifications, Exterior WallsShelter, Outside MODS (Finshing)Data Plate, Transportation DataData Plate, Identification, Finishing Section(Copies of drawings are available from the U.S. Army Natick Research

11、,Development, and Engineering Center, ATTN: STRNC-EMSS, Natick, MA 01760-5014. ). 2LProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-44402(GL)2.2 Non-Government publications. The following documents forms a part ofthis document to the extent spe

12、cified herein. Unless otherwise specified, theissues of the documents which are DoD adopted are those listed in the issue ofthe DODISS cited in the solicitation. Unless otherwise specified, the issues ofdocuments not listed in the DODISS are the issues of the documents cited in thesolicitation (see

13、6.2).INATIONAL FIRE PROTECTION ASSOCIATIONINFPA No. 70 - National Electrical Code HandbookI(Application for copies should be addressed to the National Fire ProtectionAssociation, 80 Battery March Pike, Quincy, MA 02169.)I(Non-Government standards and other publications are normally available fromthe

14、 organizations that prepare of distribute the documents. These documentsalso may be available in or through libraries or other informational services.)I2.3 Order of precedence. In the event of a conflict between the text of thisdocument and the references cited herein, the text of this document take

15、sI precedence. Nothing in this document, however, supersedes applicable laws and3. REQUIREMENTS3.1 First article. When specified (see 6.2), a sample shall be subjected tofirst article inspection (see 6.3) in accordance with 4.3.3.2 Alternate components. Components offered as equivalent to components

16、specified hereinafter and on the referenced drawings as a specificmanufacturers part or model number or equal, shall be functionally equal to themanufacturers model number identified, and of equal or better quality. Theincorporation and inclusion of such a component in the design of the specifiedend

17、 product shall not require modification or change to any other specifiedcomponent, and shall not reduce ease of maintenance to it or any othercomponents, unless such modification or change is specifically approved by thecontracting officer. Prior to manufacture of the first article, or if none isreq

18、uired, prior to commencing production, the contractor shall submit for thecontracting officers approval, a list identifying each proposed alternatecomponent, together with proof that each listed component complies withrequirements specified above. The contracting officer, at his option, mayrequire a

19、 physical sample of the proposed substitution. Approval of thesubmitted listing, together with the necessary supporting data, authorizescommencement of manufacture but does not relieve the contractor ofresponsibility that these components perform in accordance with specifiedrequirements when incorpo

20、rated into the end product.3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-44402(GL)3.2.1 Materials and components. The materials and components shall be asspecified herein and on the applicable drawings. Materials and components notdefinitely

21、 specified shall be-of the quality normally used by the manufacturerprovided the completed item complies with all the provisions of thisspecification. It is encouraged that recycled material be used when practicalas long as it meets the requirements of this specification.3.3 Design and construction.

22、 The design and construction of the finishingsection shall be as specified herein, and in Drawing 5-13-4699 and allsubsidiary drawings and parts lists pertaining thereto. All wiring shall be inaccordance with the provisions of NFPA No. 70.3.4 Finishing section operation. All electrically operated eq

23、uipment,including switches, lights. telephone, papercutter, and heat pumps shallfunction without failure when tested for performance and readability asspecified in 4.5.1 and 4.5.2.3.5 Shelter. The shelter (see 3.8) shall be either desert sand or camouflagegreen as specified see 6.2). All interior an

24、d exterior surfaces of the sheltershall be cleaned and rehabilitated when necessary to restore the original colorand finish.3.6 Technical manuals. Technical manual, 5-3610-294-13&P, shall be providedwith the Finishing Section and shall be located within the cabinet next to thepapercutter.3.7 Marking

25、. In addition to existing markings, each completed shelter shallbe marked as specified in 3.7.1 and 3.7.2, and as shown on applicable drawings.3.7.1 End item identification plates. Identification plates and Drawings5-13-5026 and 5-13-5029 shall be attached to the exterior of the shelter asspecified

26、on Drawing 5-13-5025. Appropriate information (NSN, weights, andserial no.) shall be added in the spaces provided on each dataplate.3.7.2 Center of gravity. The exterior walls of the shelter shall have acenter of gravity stencil, Drawing 5-13-5001, located as shown on Drawing5-13-5010, to identify t

27、he center of gravity for the shelter when loaded.3.8 Government furnished property (GFP). The GFP indicated in table I willbe furnished to the contractor by the Government (see 6.2), and shall be a partof the finishing section.Provided by IHSNot for ResaleNo reproduction or networking permitted with

28、out license from IHS-,-,-MIL-F-44402(GL)1/ Color shall be as specified in contract or purchase order3.9 Workmanship. The finish shall be free of blisters, peel, chipped areasor areas of no film. The finish shall be free from smudges, poor touch up.scale, scratches, stain, overspray, sag, imprint, or

29、 embedded foreign matter.Threaded fasteners shall not be broken, stripped, or loose. Holes for rivetsshall be accurately punched or drilled and any burrs that would prevent properseating of the rivet shall be removed. Rivets shall completely fill the holes,with full size heads neatly finished and in

30、 full contact with the surface of themember, and shall not be loose.3.9.1 Welders. unless otherwise specified (see 6.2), before assigning anywelder to work, the contractor shall provide the Government inspection servicewith the names of the welders to be employed in the work, together withcertificat

31、ion that each of the welders has passed a qualification test asprescribed by either of the following listed codes for the type of weldingoperation to be performed, and that such qualification is effective as definedby that particular code as follows:a. Standard Qualification Procedure of the America

32、n Welding Society.b. Welding Qualification of the American Society of MechanicalEngineers,3.9.2 Welding. The surface of parts to be welded shall be free from oxide,scale, paint, grease, and other foreign matter. Welds shall be continuous,sound, smooth, and free from porosity, cracks, incomplete fusi

33、on, anddeformation of material. All scale and flux deposits (when flux is used) shallbe removed from the finished welds, and rough edges and projections shall bedressed smooth.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-44402(GL)3.9.3 Elect

34、rical wiring. Wiring shall not be cut, abraded, or have excessiveinsulation stripped, and shall be properly and tightly joined at terminals.Wiring shall have adequate slack to provide strain relief.4. QUALITY ASSURANCE PROVISIONS4.1 Responsibility for inspection. Unless otherwise specified in thecon

35、tract or purchase order, the contractor is responsible for the performance ofall inspection requirements (examinations and tests) as specified herein.Except as otherwise specified in the contract or purchase order, the contractormay use his own or any other facilities suitable for the performance of

36、 theinspection requirements specified herein, unless disapproved by the Government.The Government reserves the right to perform any of the inspections set forth inthis specification where such inspections are deemed necessary to ensuresupplies and services conform to the prescribed requirements.4.1.

37、1 Responsibility for compliance. All items shall meet all requirementsof sections 3 and 5. The inspection set forth in this specification shallbecome a part of the contractors overall inspection system or quality program.The absence of any inspection requirements in the specification shall notreliev

38、e the contractor of the responsibility of ensuring that all products orsupplies submitted to the Government for acceptance comply with all requirementsof the contract. Sampling inspection, as part of manufacturing operations, isan acceptable practice to ascertain conformance to requirements, however

39、, thisdoes not authorize submission of known defective material, either indicated or lactual, nor does it commit the Government to accept defective material. 4.1.2 Responsibility for dimensional requirements. Unless otherwisespecified in the contract or purchase order, the contractor is responsible

40、forensuring that all specified dimensions have been met. When dimensions cannot beexamined on the end item, inspection shall be made at any point, or at allpoints in the manufacturing process necessary to assure compliance with alldimensional requirements.4.2 Classification of inspections. The inspe

41、ction requirements specifiedherein are classified as fallows:.a. First article inspection (see 4.3).b. Quality conformance inspection (see 4.4).4.3 First article inspection. When a first article is required (see 3.1 and6.2), it shall be examined for the defects specified 4.4.4 and 4.4.5, and shallbe

42、 tested for the characteristics specified in 4.5.1 and 4.5.2. The presence ofany nonconformance or failure to pass any test shall be cause for rejection offirst article.4.4 Quality conformance inspection. Unless otherwise specified, sampling forinspection shall be performed in accordance with MIL-ST

43、D-105.6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-44402(GL)4.4.1 Component and material inspection. In accordance with 4.1, componentsand materials shall be inspected in accordance with all the requirements ofreferenced documents unless ot

44、herwise excluded, amended, modified. or qualifiedin this specification or applicable purchase document.4.4.2 In-process dimensional inspection. Dimensional examinations shall bemade throughout the fabrication processes to determine conformance to thedimensions-specified on the applicable drawings. W

45、henever nonconformance isnoted, corrections shall be made to the items and lot in-process. Items whichcannot be corrected shall be removed from production.4.4.3 End item visual examination. The end items shall be examined for thedefects listed in table II. The lot size shall be expressed in units of

46、completely assembled finishing sections. The sample unit shall be one finishingsection. The inspection level shall be II and the acceptable quality level(AQL), expressed in terms of defects per hundred units, shall be 6.5 for minordefects. Any sample unit found to contain one or more major defects s

47、hall because for rejection of the lot.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-44402(GL)4.4,4 End Item dimensional inspection. The end items shall be examined forconformance to the dimensions specified on the drawings. Only those dimensi

48、onsthat can be evaluated without damaging or disassembling the end items shall beexamined. Any dimension not within the specified tolerance shall be classifiedas a defect. The lot size shall be expressed in units of finishing sections.The sample unit shall be one finishing section. The inspection le

49、vel shall beS-2 and the AQL, expressed in terms of defects per hundred units, shall be 4.0.4.4.5 End item testing. Every finish section shall be tested as specified in4.5.1. Any test failure shall be cause for rejection of the finishing sectiontested.4.4.6 Packaging examination. Examination shall be made of each finishingsection to determine that preservation, packing, and marking comp

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ARMY

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1