ARMY MIL-F-48863 C (3)-1999 FUZE GUIDED MISSILE M934E6 PARTS ASSEMBLY LOADING AND PACKING FOR《制导导弹引信M934E6零件的装载 组装和包装》.pdf

上传人:progressking105 文档编号:444708 上传时间:2018-11-15 格式:PDF 页数:7 大小:186.39KB
下载 相关 举报
ARMY MIL-F-48863 C (3)-1999 FUZE GUIDED MISSILE M934E6 PARTS ASSEMBLY LOADING AND PACKING FOR《制导导弹引信M934E6零件的装载 组装和包装》.pdf_第1页
第1页 / 共7页
ARMY MIL-F-48863 C (3)-1999 FUZE GUIDED MISSILE M934E6 PARTS ASSEMBLY LOADING AND PACKING FOR《制导导弹引信M934E6零件的装载 组装和包装》.pdf_第2页
第2页 / 共7页
ARMY MIL-F-48863 C (3)-1999 FUZE GUIDED MISSILE M934E6 PARTS ASSEMBLY LOADING AND PACKING FOR《制导导弹引信M934E6零件的装载 组装和包装》.pdf_第3页
第3页 / 共7页
ARMY MIL-F-48863 C (3)-1999 FUZE GUIDED MISSILE M934E6 PARTS ASSEMBLY LOADING AND PACKING FOR《制导导弹引信M934E6零件的装载 组装和包装》.pdf_第4页
第4页 / 共7页
ARMY MIL-F-48863 C (3)-1999 FUZE GUIDED MISSILE M934E6 PARTS ASSEMBLY LOADING AND PACKING FOR《制导导弹引信M934E6零件的装载 组装和包装》.pdf_第5页
第5页 / 共7页
亲,该文档总共7页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、W 9999906 2L15L b8 I INCH-POUND I MIL-F-48863C (AR) Amendment 3 02 October 1999 SUPERSEDING Amendment 2 17 April 1989 MILITARY SPECIFICATION FUZE, GUIDED MISSILE, W934E6 PARTS ASSEMBLY, LOADING AND PACKING FOR This amendment forms a part of Military Specification MIL-F-48863C (AR), dated O1 July 198

2、5, and is approved for use by the U.S. Army Armaments, Research, Development, and Engineering Center, and is available for use by all Departments and Agencies of the Department of Defense. PAGE 1 2.1.1 Specifications and Standards: Specifications, Military: * Delete ?MIL-S-45743? in its entirety PAG

3、E 2 2.1.1 Specifications and Standards: * Specifications, Military: Delete ?MIL-S-46860? in its entirety. * Standards: add the following: ?ANSI J-STD-O0 1 - Requirements for Soldered Electrical and Electronic Assemblies ANSI/ASQC Z1.4-1993 - Smphg Procedures and Tables for Inspection? ,wsc Ni% I of7

4、 FSC: 1336 ?. STAJVEN I? A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-M 0b 2115200 40T MIL-F-48863C(AR) AMENDMENT 3 Standards, Military: * * Add “MIL-STD-2073-1 - Standard Practice for Mil

5、itary Packaging”. Delete “MIL-STD-I OS and “MIL-STD-794” in their entirety. PAGE 3 2.2: CODE OF FEDERAL REGULATIONS: * Delete in its entirety and substitute the following: 49 CFR 100- 180 - Department of Transportation Rules for Regulations for the Transportation of Explosive and Other Dangerous Art

6、icles. Title 49 CFR is available from the Superintendent of Documents, Government Printing Office, Washington, D.C. Orders for the above publication should cite “49 CFR 100- 180 (latest revision)”.“ PAGE 9 * 3.2.13, TABLE I, Line 13, Pin 6, change “950K to “300K” PAGE 13 3.3.2, Add the following: “3

7、.3.2.1 Process control documents. Where adhesives, sealants or lubricants are permitted or required by the drawings, a process control document is required in accordance with MIL-A-48078 .” 3.3.3, Line 4, after “ . in the contract” add, “and shall include an analysis of Critical Defect material hand

8、ling (see 3.5) 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-48863C(AR) AMENDMENT 3 * 3.3.4, Delete in its entirety and add the following: a “3.3.4 Workmanship. The fuze and its components shall be fabricated and finished in a thorough, wor

9、kmanlike manner. It shall be fiee of surface defects, dirt, grease, rust, corrosion products and other foreign matter. The cleaning methods used shall not be injurious to any part nor shall any part be contaminated by the cleaning agents. Solder joints shall be in accordance with the visual inspecti

10、on standards of ANSI/J-STD-001. Soldering of metallic ribbon leads to solder coated conductors by the reflow process shall also be in accordance with the quality assurance standards of ANSI/J-STD-O01 .” PAGE 14 * 3.4.1, TABLE II, Line 13, Pin 6, change “900K to “280K PAGE 15 Add the following: “3.5

11、Critical defect material handling. An analysis of Critical Defect material handling shall be made in accordance with MIL-A-48078. This analysis shall be provided to the Government prior to First Article Submission.” PAGE 18 4.3.2.1.l/b, Delete “(SD)” after “Static Detonator Safety”. Under req/method

12、 paragraph column: Delete “3.2.9.3” Delete “SD - Initiate detonator by self destruct mode.” PAGE 22 * 4.4.2, Delete “MIL-STD-I 05” and substitute “ANSI/ASQG Z1.4-1993” PAGE 31 4.4.2.8, Major 1 01, Delete “.25% and substitute “-”. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted

13、 without license from IHS-,-,-E 9999906 2335202 282 0 MIL-F-48863C(AR) AMENDMENT 3 PAGE 34 4.2.2.1 1, Minor 204, Delete “UNF-28” and substitute “UNF-2B”. PAGE 35 4.4.2.12, Add new major category: “Category Exam Maior or Test 102 Adhesive on shoulder-stop pins missing or improperly applied following

14、cure.” AQL or Req. Para. Ref/ 100% Para. Insp. Meth. .40% 3.3.1.3 Visual PAGE 36 4.4.2.1 3, Add new major category: “Category Exam AQL or Req. Para. Ref/ Maior or Test 100% Para. Insp. Meth. 106 Sealant on 22 g 100% 3.3.1.3 Vsual lock screw missing or improperly applied. PAGE 39 4.4.2.16, Minor 203,

15、 In Column labeled Paragraph Reference/Inspection Method delete “Gage” and substitute “Visual”. * Minor 204, In Column labeled examination or test: Replace “MIL-S-45743” with ANSI/J-STD-OO 1 ”. Minor 205, In Column labeled examination or test add “I/”. a Notes: Add “I/ cracks are permitted in part n

16、umber 9297032 after potting provided they do not alter the physical integrity and profile of the potted module and epoxy has 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-h4 E i_ -F413.863 Ct AR) AMENDMENT 3 not exuded beyond the surface of 92970

17、32. The cracks may be of any configuration in any location on the module.” PAGE 41 4.4.2.18, Major 105, Delete “Slope, diameter, and true position of window recess to outside diameter” and substitute “Slope and virtual condition of the window recess”. PAGE 47 4.4.2.24, Major 1 1 1, Delete ”Actuator”

18、 and substitute “Lever” PAGE 49 4.4.2.26, Major 101, Delete “B-B” and substitute “A-A”. Major 104, Delete “A-A” and substitute “B-B”. PAGE 50 4.4.2.26, Minor 201, Delete “from centerline large” and substitute “centerline to the large” Minor 205, Delete “brcaks in to“ and substitute “breaks into”. Mi

19、nor 206. Delete “size and true position” and substitute “maximum and minimum virtual condition. PAGE 51 4.4.2.26, Minor 208, Delete “size and true position” and substitute “maximum virtual condition”. Minor 209, Delete “size and true position” and substitute “maximum and minimum PAGE 54 virtual cond

20、ition”. 4.4.2.27, Major 1 16, Delete “Large radius and true position shown in section P-P” and minimum virtual condition inspected with respect to Datums C-D and E-F of the large EldiUS ShbhWTE IKI %XeaKk P-P”. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from

21、 IHS-,-,-W 0b 21iLS204 OS5 MIL-F-48863C(AR) AMENDMENT 3 e Minor 203, Delete “Depth of second deepest recess” and substitute “Depth of third deepest recess”. PAGE 57 4.4.2.30, Major 101, Delete “Dimension and location” and substitute “Maximum and minimum virtual condition”. PAGE 61 4.4.2.34, Major 10

22、1, Delete “lens height” and substitute “Distance from tab to end opposite the lens”. PAGE 62 4.4.2.35, Major 101, Delete “lens height” and substitute “Distance from tab to end opposite the lens”. PAGE 65 4.4.2.38. Major 106, Under Column labeled Paragraph Reference/Inspection Method delete “3.2.1 3.

23、8” Major 106, Under Column labeled Requirements Paragraph add “3.2.13.8“ PAGE 67 * 4.4.3, Delete “MIL-STD-105” and substitute “ANSI/ASQC Z1.4-1993” PAGE 73 4.5.20.1 Line 3, Delete ”Move” and substitute “With the rotor locked in the armed position, move”. PAGE 74 * 5.1, Change 49CFR171-190 to 49CFR17

24、1-180 * 5.1.1, Delete in its entirety and substitute the following: ”5. I. 1 Protection. The fuzes shall be packed in fiberboard cartons with fiberboard partitions in accordance with MIL-STD-2073-1.” 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

25、PAGE 75 * 6.3, Delete ”US Army Armament, Munitions, and Chemical Command, ATTN: AMSMC-QAR-I, Dover, NJ 007801 .” and substitute “US Army TACOM-ARDEC, ATTN: AMSTA-AR-QAA-R, Picatinny Arsenal, NJ, 07806-5000.” The margins of this amendment are marked with an asterisk or vertical lines to indicate wher

26、e changes (additions, modifications, corrections, deletions) from the previous amendment were made. This was done as a convenience only and the Government assumes no liability whatsoever for nay inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of marginal notations and relationship to the last previous amendment. Custodian Amy-AR Preparing activity: Amy-AR (Project 1336-0034) 7 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-