1、 ANSI E1.16 2002 (R2012) Entertainment Technology Configuration Standard for Metal-Halide Ballast Power Cables EP/2000-7007r4a Approved as an American National Standard on 15 October 2012. It is a reaffirmation of the 2002 version. 2012 PLASA North America. All rights reserved. ANSI E1.16 2002 (R201
2、2) 2012 PLASA North America Notice and Disclaimer PLASA does not approve, inspect, or certify any installations, procedures, equipment or materials for compliance with codes, recommended practices, or standards. Compliance with a PLASA standard or recommended practice, or any American National Stand
3、ard developed under PLASAs Technical Standards Program is the sole and exclusive responsibility of the manufacturer or provider and is entirely within their control and discretion. Any markings, identification or other claims of compliance do not constitute certification or approval of any type or n
4、ature whatsoever by PLASA. PLASA neither guarantees nor warrants the accuracy or completeness of any information published herein and disclaim liability for any personal injury, property or other damage or injury of any nature whatsoever, whether special, indirect, consequential or compensatory, dir
5、ectly or indirectly resulting from the publication, use of, or reliance on this document. In issuing and distributing this document, PLASA does not either (a) undertake to render professional or other services for or on behalf of any person or entity, or (b) undertake any duty to any person or entit
6、y with respect to this document or its contents. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstance. i ANSI E1.16 2002 (R2012) 2012 PLAS
7、A North America Published by: PLASA North America 630 Ninth Avenue, Suite 609 New York, NY 10036 USA Phone: 1-212-244-1505 Fax: 1-212-244-1502 Email: standards.naplasa.org For additional copies of this document contact: The ESTA Foundation 630 Ninth Avenue, Suite 609 New York, NY 10036 USA Phone: 1-
8、212-244-1505 Fax: 1-212-244-1502 http:/www.estafoundation.org The PLASA Technical Standards Program The PLASA Technical Standards Program was created to serve the PLASA membership and the entertainment industry in technical standards related matters. The goal of the Program is to take a leading role
9、 regarding technology within the entertainment industry by creating recommended practices and standards, monitoring standards issues around the world on behalf of our members, and improving communications and safety within the industry. PLASA works closely with the technical standards efforts of oth
10、er organizations within our industry, including USITT and VPLT, as well as representing the interests of PLASA members to ANSI, UL, and the NFPA. The Technical Standards Program is accredited by the American National Standards Institute. The Technical Standards Council (TSC) was established to overs
11、ee and coordinate the Technical Standards Program. Made up of individuals experienced in standards-making work from throughout our industry, the Council approves all projects undertaken and assigns them to the appropriate working group. The Technical Standards Council employs a Technical Standards M
12、anager to coordinate the work of the Council and its working groups as well as maintain a “Standards Watch” on behalf of members. Working groups include: Control Protocols, Electrical Power, Floors, Fog and Smoke, Followspot Position, Photometrics, Rigging, and Stage Lifts. PLASA encourages active p
13、articipation in the Technical Standards Program. There are several ways to become involved. If you would like to become a member of an existing working group, as have over two hundred people, you must complete an application which is available from the PLASA office. Your application is subject to ap
14、proval by the working group and you will be required to actively participate in the work of the group. This includes responding to letter ballots and attending meetings. Membership in PLASA is not a requirement. You can also become involved by requesting that the TSC develop a standard or a recommen
15、ded practice in an area of concern to you. The Electrical Power Working Group, which authored this standard, consists of a cross section of entertainment industry professionals representing a diversity of interests. PLASA is committed to developing consensus-based standards and recommended practices
16、 in an open setting. Future Electrical Power Working Group projects will include updating this publication as changes in technology and experience warrant, as well as developing new standards and recommended practices for the benefit of the entertainment industry. ii ANSI E1.16 2002 (R2012) 2012 PLA
17、SA North America Contact Information Technical Standards Manager Karl G. Ruling PLASA North America 630 Ninth Avenue, Suite 609 New York, NY 10036 USA 1-212-244-1505 karl.rulingplasa.org Technical Standards Council Chairpersons Mike Garl President and General Manager Tomcat USA 2160 Commerce Drive P
18、O Box 550 Midland, TX 79703-7504 USA 1-432-694-7070 Mike Wood Mike Wood Consulting LLC 6401 Clairmont Drive Austin, TX 78749 USA 1-512-288-4916 Electrical Power Working Group Chairpersons Mitch Hefter 407 Deer Brooke Drive Allen, TX 75002-1707 1-972-839-8488 mkhefter.pDesignR Ken Vannice Leviton M
19、anufacturing Co., Inc. P.O. Box 2210 Tualatin, OR 97062 1-503-404-5563 iii ANSI E1.16 2002 (R2012) 2012 PLASA North America Acknowledgments The Electrical Power Working Group was the consensus body for the development of this standard. The working groups membership at the time the working group app
20、roved this standard on 3 April 2012 is listed below. Voting members: Patric J. Abaravich; I.A.T.S.E. Local 728; U Joe Boardman; Bender GmbH MP Ron Bonner; PLASA EU; U Vincent J. Cannavale; Motion Laboratories; CP James Davey; AC Power Distribution Inc.; CP Jeff deRecat; Actuant Corporation; MP Willi
21、am Drake; Actuant Corporation; MP Howard Forryan; Harting KGAA; G Ian Foulds; Entertainment Electrical Safety Committee of Ontario; G Ed Garstkiewicz; Harting KGAA; G Jerry Gorrell; Theatre Safety Programs; U Bill Grande; Leviton Manufacturing Co., Inc.; MP Torsten Gruhn; Bender GmbH MP Mitch Hefter
22、; USITT; U David Herrmann; Motion Laboratories; CP Peter Herrmann; Motion Laboratories; CP Wendy Holt; Alliance of Motion Picture and Television Producers; G Edwin S. Kramer; I.A.T.S.E. Local 1; U W. G. Krokaugger PE; Mole-Richardson Co.; CP Roger Lattin; I.A.T.S.E. Local 728; U Michael Lay; Royal P
23、hilips Electronics MP Nathan Leonard; Bender GmbH MP George Long; Aggreko; DR Bob Luther; Lex Products Corp.; CP Greg Mayberry; AC Power Distribution Inc.; CP Tyrone Mellon Jr.; Lex Products Corp.; CP R. Bruce Prochal; I.A.T.S.E. Local 728; U Alan M. Rowe; I.A.T.S.E. Local 728; U Sean Sloat; Lex Pro
24、ducts Corp.; CP Steve Terry; Electronic Theatre Controls, Inc.; MP Ken Vannice; Leviton Manufacturing Co., Inc.; MP Art Wanuch; Entertainment Electrical Safety Committee of Ontario; G Jody Williquette; Electrivert, Inc.; CP Keith S. Woods; IATSE Local 891; U Alex Yoon; Mole-Richardson Co.; CP Observ
25、er members: Daniel Ayers; Norcostco; DR Robert Barbagallo; Solotech Inc.; DR Lee J. Bloch; Bloch Design Group, Inc.; G Eric Bouchard; Cirque du Soliel; CP Louis Bradfield; U Andr Broucke; G John (Javid) D. Butler; Integrated Theatre, Inc.; CP Michael J. Carnaby; Mikan Theatricals; DR Edward R. Condi
26、t; U iv ANSI E1.16 2002 (R2012) 2012 PLASA North America Kenny Delahoussaye; Aggreko; DR Jim Digby; Linkin Park Touring/The Collective; U Marsha DuBois; Pintech Stage Connectors, Inc.; CP Steve DuBois; Pintech Stage Connectors, Inc.; CP James Eade; PLASA; G Don Earl; Earl Girls, Inc.; DR Richard L.
27、Eberth_Jr.; Airpax Corporation; MP Jose J. Flores; Kino Flo, Inc.; MP Trevor Forrest; Helvar Lighting Control; MP Phillip M. Gallo; TMB; DR Richard B. Glickman; Rosco Laboratories; MP Reuben Goldberg; Technic Services; U Jim Holladay; Luxence; G Simon Hunt; IATSE Local 891; U Kirk D. Keen; Hollywood
28、 Lighting, Inc.; DR Hiroshi Kita; Marumo Electric Co., Ltd.; MP Wayne Kowalski; Coleman Cable Inc.; MP Charles (Chuck) Kurten; Underwriters Laboratories, Inc.; G Marty Lazarus; Chicago Spotlight, Inc.; DR Dave Lester; Clair Global; U William L. Maiman; U Paul F. Mardon; Pulsar Ltd.; MP Pat Miller; H
29、ubbell Inc. MP Martin Moore; DE David Murray; IPC Resistors Inc.; CP Kevin OBrien; Bestek Lighting U Natti Pierce-Thomson; North American Theatre Technology; U Elizabeth E. (Lizz) Pittsley; U Larry Schoeneman; DesignLab Chicago, Inc.; DE Michael Scudday; SSRC, Inc.; CP Ford Sellers; Cornell Universi
30、ty; U Mike Skinner; Alliance of Motion Picture and Television Producers; U Arnold Tang; Arnold Tang Productions; G Eric Tishman; Rosco Laboratories; MP Stephen Vanciel; U Colin Waters; TMB; DR Richard Wolpert; Union Connector Company; CP Jiantong Wu; Beijing Special Engineering Design G CP custom-ma
31、rket producer DE designer DR dealer or rental company MP mass-market producer G general interest U user v ANSI E1.16 2002 (R2012) 2012 PLASA North America Entertainment Technology Configuration Standard for Metal-Halide Ballast Power Cables 1 Scope This standard describes a standard practice for gro
32、unding contact assignment for detachable power cables on 6kW, 12kW and 18kW metal-halide lamp ballasts used in the motion picture and television industries on portable studio luminaires that use the MIL-C-5015 or MIL-DTL-5015 connectors with #28-6 insert configuration on the ballast end of the power
33、 cable. 2 Purpose The use of a standardized pin assignment will reduce the possibility of ballast chassis to ungrounded power conductor connections caused by mismatched cables and ballasts. 3 Requirements Connectors on detachable power cables for use on 6kW, 12kW and 18kW metal-halide lamp ballasts
34、with MIL-C-5015 or MIL-DTL-5015 equivalent #28-6 insert configurations (one-piece construction) and contact configuration (screw machine) shall designate the “A” position as the grounding contact. This shall be extended for mate first/break last operation. Front view of the male connector ANSI E1.16 - 2002 (R2012), Entertainment Technology - Configuration Standard for Metal-Halide Ballast Power Cables, document number EP/2000-7007r4a 1