1、 MIL-F-63337(AR) AMENDMENT 5 18 July 2001 SUPERSEDING AMENDMENT 4 03 April 1992 MILITARY SPECIFICATION FIRING ATTACHMENT, BLANK AMMUNITION: M19 This amendment forms a part of Military Specification MIL-F-63337 (AR), dated 19 October 1979, and is approved for use by the U.S. Army Armament, Armament,

2、Research, Development and Engineering Center, and is available for use by all Departments and Agencies of the Department of Defense. PAGE 1 Throughout the specification, change all “XM19” to “M19” wherever it appears. 2.1: SPECIFICATIONS, MILITARY: Delete: “MIL-A-48078 - Ammunition, Standard Quality

3、 Assurance Provisions, General Specification for” and substitute: “MIL-W-63150 - Weapons and Support Material, Standard Quality Assurance Provisions, for PAGE 3 4.1: Delete “MIL-A-48078” and substitute “MIL-W-63150”. PAGE 4 4.3.2: Delete “MIL-A-48078” and substitute “MIL-W-63150”. 4.3.3: Delete “See

4、 MIL-A-48078” and substitute “If any assembly, component or test specimen fails to comply with any of the applicable requirements, the first article sample shall be rejected. The Government reserves the right to terminate its inspection upon failure of an assembly, component or test specimen in the

5、sample to comply with any of the stated requirements.” AMSC N/A 1 of 5 FSC 1005 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. INCH-POUND MIL-F-63337 was inactivated after 11 December 1995 for new design. Provided by IHSNot for ResaleNo reproduction or networking p

6、ermitted without license from IHS-,-,-MIL-F-63337(AR) AMENDMENT 5 2PAGE 5 TABLE I. First Article Inspection: Under “Chamber” delete “Salt Spray Test”; for “No. of Sample Units” delete “(a)”, for “REQUIREMENT PARAGRAPH” delete “3.2”, for “PARAGRAPH REFERENCE/INSPECTION METHOD” delete “4.5.2”. (Note:

7、Amendment 1 added the Salt Spray Test on the Chamber) PAGE 6 TABLE I. First Article Inspection: Under “CLAMP, THREADED”, delete “(Dw. D93326857)” and substitute “(Dwg. 9326860)”. 4.4.1: Delete in its entirety and substitute: “4.4.1 Inspection lot formation. The term “inspection lot” is defined as a

8、homogeneous collection of units of product from which a representative sample is drawn or which is inspected 100 percent to determine conformance with applicable requirements. Units of product selected for inspection shall represent only the inspection lot from which drawn and shall not be construed

9、 to represent any prior or subsequent quantities presented for inspection. Homogeneity shall be considered to exist provided the inspection lot has been produced by one manufacturer, in one unchanged process, using the same materials and methods in accordance with the same drawings, same drawing rev

10、isions, same specifications and same specification revisions, and complies with the provisions for submission of product as specified in MIL-STD-105. All material submitted for inspection in accordance with this specification shall comply with the inspection procedure which is being applied to deter

11、mine conformance with requirements. Lot numbering, as required, shall be in accordance with MIL-STD -1168. Blank firing attachments shall be assembled from component parts that have met all inspection requirements specified herein.” 4.4.2: Delete in its entirety and substitute the following: “4.4.2

12、Examination. The examinations listed in the item detail specification for Classification of Defects shall be performed on inspection lots as defined in 4.4.1 of this specification.” a. Sampling plans. Unless otherwise specified in the Classification of Defects and Test Tables, sampling plans for Maj

13、or and Minor defects shall be in accordance with MIL-STD-105, Inspection Level II attributes inspection, unless 100% is indicated. b. Critical defects. Unless otherwise specified, inspection for Critical defects shall be 100 percent. PAGE 8 4.4.2.1: Critical category: Delete “None defined” and subst

14、itute: “1. Diameter of the smallest hole 100% 3.2 SMTE in the center” (NOTE: Amendment 2 deleted “Gage” and substituted “SMTE”). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-63337(AR) AMENDMENT 5 3Major Category: Major 101: Delete in its ent

15、irety Major 102: Delete in its entirety Major 108: Delete “(.85)” and substitute “(.86)” Majors 103 thru 113: Delete “Gage” and substitute “SMTE” Minor 201: Delete “Gage” and substitute “SMTE” 4.4.2.1, Major 110: Delete “for specified length” PAGE 9 4.4.2.2: Major 103 thru 107: Delete “Gage” and sub

16、stitute “SMTE” PAGE 10 4.4.3.2, Major Category: Major 108: Delete “(.50)” and substitute “(.45)” Major 103 thru 113: Delete “Gage” and substitute “SMTE” 4.4.2.3, Major 114: Delete “Gage” and substitute “SMTE” PAGE 13 4.4.2.5, Major 101: Delete “Gage” and substitute “SMTE” * 4.4.2.5, Major 110: Delet

17、e “.74” and substitute “.69” PAGE 14 4.4.2.6, Majors 103 thru 114: Delete “Gage” and substitute “SMTE” PAGE 15 4.4.2.6, Majors 115 thru 119: Delete “Gage” and substitute “SMTE” PAGE 16 4.4.2.7, Majors 103 thru 106: Delete “Gage” and substitute “SMTE” PAGE 17 Major Category: Major 101: Delete in its

18、entirety Major 103: Delete in its entirety Major 104: Delete in its entirety Major 105: Delete “Gage” and substitute “SMTE” 4.4.4: Delete “See Section 6 of MIL-A-48078 and 6.3 herein” and substitute “See MIL-W-63150 and 6.3 herein.” Provided by IHSNot for ResaleNo reproduction or networking permitte

19、d without license from IHS-,-,-MIL-F-63337(AR) AMENDMENT 5 4PAGE 20 4.5.4: Delete in its entirety and substitute the following: “4.5.4 Functioning. The assemblies selected for the functioning test shall be assembled to the .50 Caliber M2, Heavy Barrel Machine Gun, Government Standard Caliber .50, M1

20、A1 blank cartridges shall be used for this test. A standard belt, consisting of one hundred (100) rounds, shall be fired in approximately twenty (20) round bursts. Any assembly which fails to comply with the requirements specified in 3.5 shall be classed defective. All test results shall be recorded

21、.” 6.2: Delete in its entirety and substitute the following: “6.2 Ordering data. Procurement documents shall specify the following: 6.2.1 Procurement requirements. a. Title, number and date of this and the item detail specification. b. Quantity required and delivery schedules. c. Serialization requi

22、rements, if possible d. Quality Conformance Inspection, if other than specified in Section 4 of item detail specification. e. First Article sample requirements, if other than specified in Section 4 of item detail specification. f. Packaging requirements, if other than specified In Section 5 of item

23、detail specifiction. g. Certificates of conformance for each lot or shipment of product. 6.2.2 Contract data requirements. a. Contract data requirements for inspection equipment designs (conforming to Data Item Description DI-E-1118 or DI-E-1714 with appropriate addendum to each). b. Data cards. Whe

24、n required by incorporation of DD Form 1423 into the contract, data cards shall be prepared for each lot in accordance with Data Item Description DI-L-1410.” 6.3: Delete “MIL-A-48078” and substitute “MIL-W-63150”. 6.3: Delete “DRDAR-QAF-I, ARRADCOM” and substitute “AMSMC-QAF-I(D), ARDEC”. PAGE 21 6.

25、4: Delete in its entirety and substitute the following: “6.4 Drawings. Drawings listed in Section 2 of this specification under the heading U.S. Army Armament, Research, Development and Engineering Center (ARDEC) may also include drawings prepared and identified as U.S. Army Research and Development

26、 Command ARRADCOM), Edgewood Arsenal, Frankford Arsenal, Rock Island Arsenal, or Picatinny Arsenal drawings. Technical data originally prepared by these activities are now under the cognizance of ARDEC.” Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-

27、,-MIL-F-63337(AR) AMENDMENT 5 5The margins of this Amendment are marked with an asterisk or vertical lines to indicate where changes (additions, modifications, corrections, deletions) from the previous amendment were made. This was done as a convenience only and the Government assumes no liability w

28、hatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluated the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous amendment. Custodian: Preparing activity: Army-AR Army-AR (Project 1005-0877) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-