1、MIL-G-12327J 13 W 9999906 0274042 T Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, US. Army Chemical Research, Development and Engineering Center, AT”: SMCCR-SPT-S, Aberdeen Proving

2、Ground, MD 210 10-5423 by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. MIL-G-12327J 6 June 1989 SUPERSEDING MIL-G-O0 12327H(EA) . MIL-G-12327E 18 June 1984 18 September 1968 MILITARY SPECIFICATION GRENADE, H

3、AND, SMOKE, HC, M8 This speccation is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers one type of hand grenade for use in producing white smoke. O 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications, stan

4、dards, and handbooks. The following specifications, stan- dards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DODI

5、SS) and supplement thereto, cited in the solicitation (see 6.2). DISTRIBUTZON STATEMENT A. Approved for public release; distribution is unlimited. d THIS DOCUMENT CONTAINS 12 PAGESI - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-G-12327J i3 M

6、7777706 0274043 1 M MIL-G- 1 2 32 7 J SPECIFICATiONS FEDERAL TT-W-572 - Wood Preservative: Water Repellent PPP-B-601 - Boxes, Wood, Cleated-Plywood PPP-B-62 1 - Boxes, Wood, Nailed and Lock-Corner PPP-F-32 O - Fiberboard: Corrugated and Solid, Sheet Stock (Container Grade) and Cut Shapes MILITARY MI

7、L-B-2427 - Boxes, Ammunition Packing: Wood, Nailed MIL-B-46506 - Boxes, Ammunition Packing, Wood, Wirebound STANDARDS h4LITARY MIL-STD-105 - Sampling Procedures and Tables for Inspection by Attrib- MIL-STD-414 - Sampling Procedures and Tables for Inspection by Variables MIL-STD-1168 - Ammunition Lot

8、 Numbering utes for Percent Defectives (Unless otherwise indicated, copies of federal and military specifications, standards, and handbooks are available from the Naval Publications and Forms Center, (ATTN: NPODS), 5801 Tabor Avenue, Philadelphia, PA 19120-5099.) 2.1.2 Other Government documents, dr

9、awings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. U.S. ARMY ARMAMENT, MUNITIONS AND CHEMICAL COMMAND DRAWINGS 19-48-41

10、 16/65 - Unitization Procedures for Boxed Ammunition and Compo- nents on 4-Way Entry Pallets (Copies are available from Director, U.S. Army Defense Ammunition Center and Schoot, ATI“: SMCAC-DEO, Savanna, IL 61074-9639.) 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without l

11、icense from IHS-,-,- MIL-G-12327J 13 9799906 029404LI 3 W MIL-G-12327J U.S. ARMY CHEMICAL RESEARCH, DEVELOPMENT AND ENGINEERING CENTER DRAWINGS 13-9-105 - Label, Continuous 13-9-120 1 Packing, Grenade 13-19-32 - Grenade, Hand, Smoke, HC, AN-M8 13-19-38 - Card, Instruction 13-19-83 - Marking For: M8

12、and M18 Smoke Grenades 13-19-94 - Starter Cup Assembly 143-1-1 - White Smoke Mixture - I (Copies are available from Commander, U.S. Army Chemical Research, Development SMCCR-SPT-O, Aberdeen Proving Ground, MD and Engineering Center, AT“: 21010-5423.) 2.2 Order of precedence. In the event of a confli

13、ct between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Materials and components. 3.1.1 Materials

14、. All materials cited on Drawing 13-19-32 and subsidiary drawings shall conform to the specifications listed thereon, or to the specific characteristics set forth on the drawings. 3.1.2 Components. All components of the grenade shall conform to the specifications and drawings listed on Drawing 13-19

15、-32 and on subsidiary drawings. 3.2 Filling. The grenade shall be filled with HC smoke mixture as specified on Draw- ing 13-19-32. 3.3 Assembly. The grenade shall be assembled as shown on Drawing 13-19-32 (see 6.6). 3.4 Functioning. When tested in accordance with 4.2.4.1, the grenade shall ignite an

16、d emit a continuous smoke cloud under pressure within 15 seconds (lag time) after the fuze is activated. The smoke cloud shall be emitted under pressure (smoke emission time) for a period between 90 and 135 seconds. The total flaming time, if any, of the grenade shall O 3 Provided by IHSNot for Resa

17、leNo reproduction or networking permitted without license from IHS-,-,-4 flIL-G-L2327J 13 W 993790b 029LIoLI5 5 MIL-G- 12 32 75 not exceed 20 percent of the total burning time (see figure 1). The grenade shall show no evidence of deflagration see 6.5(e). 3.5 Volatiles content. The volatiles content

18、of the starter mix slug shall not exceed 1 percent when tested in accordance with 4.2.4.2. in accordance with 4.2.4.4. 3.6 Moisture content. Each batch of pyromixture shall comply with Drawing 143-1-1 3.7 Workmanship. The grenade shall be free from smoke mix contamination, foreign matter and damage

19、such as dents, cracks or deformation which could impair its intended 4. QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection. Unless otherwise specified in the contract or pur- chase order, the contractor is responsible for the performance of all inspection require- ments (examinations and

20、 tests) as specified herein. Except as otherwise specified in the contract or purchase order, the contractor may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right t

21、o perform any of the inspections set forth in this specification where such inspections are deemed necessary to ensure supplies and services conform to prescribed requirements. 4.1.1 Responsibility for compliance. All items shall meet all requirements of sections 3 and 5. The inspection set forth in

22、 this specification shall become a part of the contrac- tors overall inspection system or quality program. The absence of any inspection require- ments in the specification shall not relieve the contractor of the responsibility of ensuring that all products or supplies submitted to the Government fo

23、r acceptance comply with all requirements of the contract. Sampling inspection, as part of manufacturing operations, is an acceptable practice to ascertain conformance to requirements, however, this does not authorize submission of known defective material, either indicated or actual, nor does it co

24、mmit the Government to accept defective material. 4.1.2 Qbjective evidence. The contractor shall provide objective evidence acceptable to the contracting officer that the requirements of 3.1, 3.2, and section 5 for which spe- cific inspection has not been provided in this specification have been sat

25、isfied. O 4.2 Quality conformance inspection. 4.2.1 Lotting. 4.2.1.1 Grenades. A lot shall be identified and controlled in accordance with MIL- Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-G-12327J 13 979990b 0294046 7 t 8 O MIL-G-12327J FUZE

26、LEVER RELEASED FUZE DELAY TIME EMISSION UNDER PRESSURE STARTS NO PRESSURE,-C C TOTAL BURN TIME-., FLAMING TIMES NOTE: SMOKE EMISSION TIME EQUALS TOTAL BURNING TIME MINUS TOTAL FLAMING TIME FIGURE 1. Total burning time 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without lic

27、ense from IHS-,-,- MIL-G- 12 32 7 J work shifts not to exceed two weeks consecutive duration, whichever occurs first, from the same materials and under essentially the same manufacturing conditions. However, no more than one lot of fuzes or more than one interfix of metal components, smoke, starter

28、mix ingredients, or starter slugs from one manufacturer shall be represented in any one lot of assembled grenades. The minimum lot size shall be 1,201 grenades. 4.2.1.2 Starter slugs. A lot of starter slugs shall consist of the starter slugs provided by one manufacturer using the same manufacturing

29、process. Only one lot of each starter slug mix ingredient from one manufacturer shall be used in any one lot of starter slugs. , * 4.2.2 Sampling. 4.2.2.1 For examination. Sampling shall be conducted in accordance with MIL- 4.2.2.2 Starter slugs. Sampling shall be conducted in accordance with MIL-ST

30、D-105, 4.2.2.3 For destructive test. Sampling shall be conducted in accordance with MIL- STD-105, level S-4, for duds, lagtime, intermittent smoke, flame, and deflagration. The sample for smoke emission time shall be equivalent to that segment of the sample speci- fied in MIL-STD-414, level II (see

31、6.5). 4.2.3 Inspection procedure. 4.2.3.1 For examination. Sample grenades and the levels A and B packaging shall be 4.2.3.2 For starter slugs. The starter slugs shall be tested in accordance with 4.2.4.2 examined in accordance with the classification of defects and with MIL-STD-105. using an AQL of

32、 0.40 percent. tics listed in (b), (c), (d) and (e) below and figure 1. (a) For smoke emission time (see 6.5 and 6.6). Sample grenades shall be tested in accordance with 4.2.4 and MIL-STD-414, example B3 using an AQL of 2.5 percent defective. (b) Duds. Sample grenades shall be tested in accordance w

33、ith 4.2.4 and MIL-STD-105 using an AQL of 1.5 percent defective. Fuze failure shall be counted as a defect. The cause of the dud shall be identified (see 6.4). in accordance with 4.2.4 and MIL-STD-105 using an AQL of 2.5 percent defective. 4.2.3.3 For destructive tests. The entire sample shall be ev

34、aluated for the characteris- . (c) Lagtime, intermittent smoke and flame. Sample grenades shall be tested 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-G-12327J 13 M 979770b 027LiOLi O MIL-G-12327J O * . O (d) Deflagration. Sample grenades sh

35、all be tested in accordance with 4.2.4. Any evidence of deflagration shall be cause for rejection of the lot. (e) Incorrect color. Sample grenades shall be tested in accordance with 4.2.4. Any grenade which emits smoke of an entirely different color shall be cause for rejection of the entire lot. 4.

36、2.3.3 For critical defects. Each grenade in the lot shall be examined for its critical characteristic listed in the classification of defects. 4.2.3.4 Classification of defects. (a) Categories Critical: 1 Maior: 101 Maior: 102 103 104 so5 106 Minor: 201 Grenade, hand, smoke, HC, AN-MS - assembly (Dr

37、awing 13-19-32) Defects Acceptance standards 4.2.4.3 Safety pin not spread Visual AQL 1.0 percent defective Filling height incorrect AQL 1.0 percent defective Component missing or incorrectly assembled Incorrect torque applied to fuze Tape loose or does not completely cover hole Marking missing, ill

38、egible, or incorrect Workmanship (3.7) AQL 2.5 percent defective Protective finish missing or incorrect 7 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-G-123273 13 393930b 0294043 2 i- MIL-G-123275 (b) Starter cup assembly, prior to assembly (

39、Drawing 13-19-94) Categories Defects Critical: None defined Maior: AQL 1.0 percent defective 101 102 103 Height of slug incorrect 104 Slug weight incorrect 105 Slug cracked or chipped Depth of cavity in slug incorrect Diameter of cavity in slug incorrect (c) Packaging (section 5). Categories Defects

40、 Critical: None defined Maior: AQL 2.5 percent defective 101 102 103 Instruction card missing 104 Strap loose or missing Loose pack (including loose grenade) Marking missing, incorrect, or illegible 4.2.4 Tests. 4.2.4.1 Functioning. The grenade shall be submerged in water in an upright position for

41、a minimum period of 30 minutes to a depth of 1 to 2 inches measured from the top surface of the grenade. The temperature of the water shall be colder or equal to but no greater than 10F above the temperature of the grenade at the time of immersion. Within 1 hour after removal from the water, the gre

42、nade shall be functioned as follows: Grasp the grenade with the fuze lever against the palm; remove the safety pin and throw the grenade downwind in an area that is clear of flammable material, grass, etc. (see 6.6) that may influence flaming time observation if flaming occurs. The test results prov

43、ided shall include the following as well as the standard test data: (a) Lag time (b) Total burning time 8 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-G-LZ327J 13 m 7997706 0274050 7 m MIL-G-12327J I * i- (e) Total flaming time (d) Smoke emiss

44、ion time 4.2.4.2 Starter slugs. The volatiles content of each lot of starter slugs shall be deter- mined by drying the samples in a vacuum desiccator to constant weight. 4.2.4.3 Filling height. Examination for correct filling height shall be performed as an “in process” check on each lot using MIL-S

45、TD-105 with an AQL of 1.0 percent defective. 4.2.4.4 Moisture content. The moisture content of the pyromixture shall be measured prior to consolidation into grenades. When a batch fails to meet the moisture content requirement, it may be reblended or combined to bring the moisture content within dra

46、w- ing requirements. 5. PACKAGING 5.1 Unit packing, level A. Grenades shall be individually unit packed as specified on Drawing 13-9-120. 5.2 Packing. Level of packing shall be as specified (see 6.2). 5.2.1 Level A. Sixteen grenades unit packed as specified in 5.1 shall be packed together, fuze end

47、up, in one layer, in an overseas-type or class wood shipping container conforming to either PPP-B-601, style J; PPP-3-621, class 2, style 4, type II; or type I, class 2, grade A of MIL-B-46506, except that one additional vertical batten shall be applied to the center of each end panel. The shipping

48、container or the finished wood parts thereof shall be completely immersed for a minimum of one minute in a water-repellent wood preservative conforming to composition A of IT-W-572. Fiberboard pads, con- forming to type CF, grade WSc, variety SW of PPP-F-320 shall completely separate the contents fr

49、om the shipping container. Additional pads shall be used as required to insure a tight pack. Inside dimensions of the shipping container shall be approximately 12-1/2 by 12-1/2 by 6-98 inches with Drawing 13-9-120 (SH1 of 2 and SH2 of 2) Packaging Grenade Assembly. An instruction card conforming to Drawing 13-19-38 shall be placed on top of the packed grenades. The PPP-B-601 and PPP-B-621 shipping