1、MIL-bl4745 (MU) -1 15 JUNE 1972 This Aniendment form a part of Military Specification MLM-14745 (MU), dated i5 April 1968. Paragraph 2.1: Delete iiPURC-IASE XSCRIF11WS PA-PD-3087 - Amnium Nitrate Grained (For Use In Explosives)“, and substitute “MIL-A-50460 - Annnium Nitrate, Prilled (For Use In Amn

2、unition) .I1 Paragraph 3.1.1: Delete in its entirety an substitute the following: “3.1.1 Amnonium Nitrate.-The amnoniun nitrate shall comply with the requirements of Military Specification MILA-50460 (M). of the ambnium nitrate shall not exceed 0.15 percent when tested as specified in 4.2.2.11 The m

3、oisture Paragraph 3.2 - Conposition, Table I: Delete the following: “Percent 40 t 3 . 20T2 40 3 - And substitute: “Percent 40 + 3 20 T 3 40 3 II - Pat.agrah 3.5 : biete in its entirety, FSC: i376 f Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-

4、M-14745 (1) 13 P 7977906 027b487 3 W T Paragraph 4.2.3, Sampling for Test: Delete the following: “Samples from kettle from each line“ and substitute: “The samples shall be taken from the discharge, spout (leg) of the min pouring kettle irmiediately before entering the bms at each line and shift.“ Pa

5、ragraph 4.3.1: Delete in its entirety and substitute the following: “4.3 , 1 Determination of charge composition. -The specimen shall be taken from a sample approximately four (4) inches in diameter with a maximum thickness of one-quarter (U41 inch that has been ground to pass a number 10 mesh sieve

6、, All weighing shall be done on an analytical balance to plus or miYius 0.0002 gram. The specimen selected from the ground sample shall be approximately 2 grams, accurately weighed, and shall be placed in a tamd, medum-porosity, sintered glass crucible. A stirring rod and about 20 ml of benzene shal

7、l be added to the crucible and the contents shall be stirred three times for about 30 seconds each time. The crucible and contents shall be placed on a filtration apparatus and suction applied to draw out the benzene solution. With the solution still on, the walls of the crucible and the stirring ro

8、d shall be washed down with additional benzene. The entire procedure, starting with the addition of 20 ml of benzene, shall be repeated two additional tims in order to insure complete extraction of the “i?. After the third extraction, remove the stirring rod after rinsing with benzene to insure that

9、 all adhering particles are washed into the crucible and continue the suction for about a minute after all the benzene solution has been drawn through. The crucible, which now contains mnium nitrate and aluminum, shall be placed in an oven at 100 degrees plus or minus 5 degrees C for approximately 1

10、5 minutes, cooled in a desiccator, and weighed. i After weimg the stirring rod shall be replaced in the crucible and about 20 m of distilled water.shaU be added. As before, the contents shall be stirred three times, for about 30 seconds each time, the solution shall be drawn through the crucible by

11、applying suction and the entire process repeated for a total of three extractions with 20 ml of water each time, After the third extraction, the stirring rod shall be washed with water and remved, as before, but the final water wash shall be followed by an acetone rinse in order to displace the wate

12、r and facilitate drying. shall be aspirated for about a minute before transferring to the oven. oncible, which now contains only aluminum, shall be dried for approximately i5 minutes at 100 degrees plus or minus 5 degrees C, cooled in a desiccator, and weighed. The composition shall be calculated as

13、 follows: After the acetone rinse, the crucible The 0,Ol w Amnonium Nitrate “4 NO3 % = W2 - W3 -mn? 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Al*m% = w3 - wo o. 01w W = Weight of Specimen; gram Wo= Weight of enpty crucible, gram W = Weight of

14、 cnioible, “4 NO3 and Al, $= Weight of crucible and Al, gram wi= w + wo, gram c“IDIAN: ARMY-Mu PHEPARING A(XWITY: ARMY-Mu PJ5WEXX NUMBER: 1376-A-O12 *U. S GOVERNMENT PRINTING OFFICE: 1972 -714-538/1666 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-