ARMY MIL-PRF-3098 110 E-2011 CRYSTAL UNIT QUARTZ CR129 U.pdf

上传人:孙刚 文档编号:447014 上传时间:2018-11-16 格式:PDF 页数:3 大小:36.65KB
下载 相关 举报
ARMY MIL-PRF-3098 110 E-2011 CRYSTAL UNIT QUARTZ CR129 U.pdf_第1页
第1页 / 共3页
ARMY MIL-PRF-3098 110 E-2011 CRYSTAL UNIT QUARTZ CR129 U.pdf_第2页
第2页 / 共3页
ARMY MIL-PRF-3098 110 E-2011 CRYSTAL UNIT QUARTZ CR129 U.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 INCH-POUND AMSC N/A FSC 5955 MIL-PRF-3098/110E 11 July 2011 SUPERSEDING MIL-PRF-3098/110D 27 July 2005 PERFORMANCE SPECIFICATION SHEET CRYSTAL UNIT, QUARTZ, CR129/U This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring th

2、e product described herein shall consist of this specification sheet and MIL-PRF-3098. Pertinent characteristics: 9 MHz to 12 MHz; fundamental; noncontrolled; antiresonance. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Marking to be in accordan

3、ce with MIL-PRF-3098. FIGURE 1. Crystal unit - CR129/U. Ltr Inches mm Min Max Min Max A - .402 - 10.21 B - .183 - 4.65 C - .435 - 11.05 D .184 .200 4.67 5.08 E - .530 - 13.46 F .50 - 12.7 - G - .150 - 3.81 H .015 .019 0.38 0.48 Copyright Communications - Electronics Command Provided by IHS under lic

4、ense with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-3098/110E 2 REQUIREMENTS: Dimensions, marking, and configuration: See figure 1. Frequency range: 9.0 MHz to 12.0 MHz, inclusive. Capacitance, shunt: 7.0 pF, maximum. Mode of oscillation: Fundamen

5、tal. Rated drive level: 1.0 mW, maximum. Antiresonance, load capacitance: 32.0 pF 0.5 pF. Operating temperature range (noncontrolled): -55C to +90C, inclusive. Frequency tolerance: 35 ppm. Equivalent resistance: MHz 9.0 to 10.0 35 Ohms, maximum 10.0+ to 12.0 25 Shock (specified pulse): Method 213, M

6、IL-STD-202, test condition K; consisting of 18 impact shocks of 15 gravity units each having a duration of 11 milliseconds; 3 shocks along each direction in each of 3 mutually perpendicular planes. Frequency change permitted: 5 ppm. Equivalent resistance: 15 percent or 2 ohms, whichever is greater.

7、Vibration: Method 204, MIL-STD-202; test condition A. Frequency change permitted: 5 ppm. Equivalent resistance change permitted: 15 percent or 2 ohms, whichever is greater. Thermal shock: Frequency change permitted: 5 ppm. Equivalent resistance change permitted: 15 percent or 2 ohms, whichever is gr

8、eater. Aging: Frequency change permitted: 5 ppm. Part or Identifying Number (PIN): For Product Level B, PIN shall be CR129/U or CR129B/U (followed by specified frequency). For Product Level S, PIN shall be CR129S/U (followed by specified frequency), see 1.2 of MIL-PRF-3098. Reference documents. In a

9、ddition to MIL-PRF-3098, this document references the following: MIL-PRF-202 The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any in

10、accuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Copyright Communications - Electronics Command Provided by IHS under lice

11、nse with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-3098/110E 3 Custodians: Preparing activity: Army - CR Army - CR Navy - EC Air Force - 99 Agent: DLA - CC DLA - CC Review activities: (Project 5955-2011-002) Air Force - 19, 84 NOTE: The activities

12、 listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • STAS SR CEI 455-2+A1-1995 Specification for solventless polymerisable resinous com-pounds used for electrical insulation Part 2 Methods of test《用于电气绝缘非溶性聚合物树脂复合物的规格 第2部分:测试方法》.pdf STAS SR CEI 455-2+A1-1995 Specification for solventless polymerisable resinous com-pounds used for electrical insulation Part 2 Methods of test《用于电气绝缘非溶性聚合物树脂复合物的规格 第2部分:测试方法》.pdf
  • STAS SR CEI 455-2-2-1995 Specification for solventless polymerisable resinous compounds used for electrical insulation Part 2 Methods of test Test methods for coating powders for e.pdf STAS SR CEI 455-2-2-1995 Specification for solventless polymerisable resinous compounds used for electrical insulation Part 2 Methods of test Test methods for coating powders for e.pdf
  • STAS SR CEI 479-1-1995 Effects of current on human beins and livestock Part 1 General aspects《对人类和牲畜的通用影响 第1部分:一般问题 》.pdf STAS SR CEI 479-1-1995 Effects of current on human beins and livestock Part 1 General aspects《对人类和牲畜的通用影响 第1部分:一般问题 》.pdf
  • STAS SR CEI 488-1995 Dimensions of copper conductors in local cables《地方性电缆的铜导体尺寸 》.pdf STAS SR CEI 488-1995 Dimensions of copper conductors in local cables《地方性电缆的铜导体尺寸 》.pdf
  • STAS SR CEI 502-1995 Extruded solid dielectric insulated power cables for rated voltages from 1 kV up to 30 kV《额定电压1千伏至30千伏所用的压制固体电介质绝缘电力电缆 》.pdf STAS SR CEI 502-1995 Extruded solid dielectric insulated power cables for rated voltages from 1 kV up to 30 kV《额定电压1千伏至30千伏所用的压制固体电介质绝缘电力电缆 》.pdf
  • STAS SR CEI 510-1-2-1984 Methods of measurement for radio equipment used in satellite earth station Part 1 Measurements common to sub-system and combination of sub-system Section T.pdf STAS SR CEI 510-1-2-1984 Methods of measurement for radio equipment used in satellite earth station Part 1 Measurements common to sub-system and combination of sub-system Section T.pdf
  • STAS SR CEI 517-1995 Gas-insulated metal-enelosed switchgear for rated voltages of 72 5 kV and above《72 5千伏和以上额定电压绝缘气体金属封闭开关设备 》.pdf STAS SR CEI 517-1995 Gas-insulated metal-enelosed switchgear for rated voltages of 72 5 kV and above《72 5千伏和以上额定电压绝缘气体金属封闭开关设备 》.pdf
  • STAS SR CEI 534-4+A1-1995 Industrial-process control valves Part 4 Inspection and routine testing《工业生产控制阀 第4部分:检查和例行测试 》.pdf STAS SR CEI 534-4+A1-1995 Industrial-process control valves Part 4 Inspection and routine testing《工业生产控制阀 第4部分:检查和例行测试 》.pdf
  • STAS SR CEI 534-5-1995 Industriai-process control vaives Part 5 Marking《工业生产控制阀 第5部分:标记》.pdf STAS SR CEI 534-5-1995 Industriai-process control vaives Part 5 Marking《工业生产控制阀 第5部分:标记》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ARMY

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1