1、MIL-R-44023A (3) 36 9 7977906 04bL73 9 I INCH-POUND 1 MIL-R-44023A( GL) AMENDMENT 3 29 November 1990 SUPERSEDING AMENDMENT 2 5 July 1983 MILITARY SPECIFICATION REPRODUCTION SET, DIAZO PROCESS, FOR FIELD USE This amendment forms a part of Military Specification MIL-R-44023A(GL), dated 7 May 1981, and
2、 is approved for use by the Natick Research, Development, and Engineering Center, Department of the Army, and is available for use by all Departments and Agencies of the Department of Defense. PAGE 1 2.1, under “STANDARDS MILITARY“: Add “MIL-STD-810 - Environmental Test Methods“. PAGE 2 fi 2.1, unde
3、r “DRAWINGS“: Delete “5-7-180 - Back Up Plates“. PAGE 3 3.4.1, line 2, between the words “machine“ and “with“: Insert “mounted in a carrying case as shown on Drawing 5-7-173“. After 1st sentence: Add “The copier shall be capable of operating in the carrying case base and provide the operator easy ac
4、cess to reproduced material as if is being fed out of the copier. reproduce diazo films in red, blue, sepia, green and black images when tested as specified in 4.5.5. The copier shall be able to Line 3, after “four“: Add “120 watt or three 140 watt“. Line 4, after “hi-lo switch“: Add “or equivalent
5、type hi-lo speed con t ro 1 It . Lines 11 and 12: Delete “The case shall be 17 inch high x 70 inch long x 26 inch deep“. AMSC N/A 1 of 3 FSC 3610 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted wit
6、hout license from IHS-,-,-MIL-R-44023A(GL) AMENDMENT 3 PAGE 4 3.4.2, lines 3 and 4: Delete “The expendable supply case shall be 10 inch high x 37 inch long x 27 inch deep.“ 9: Table I, in all 7 item descriptions delete “GAF Corporation“ and subs t i tu te “Oza 1 id Corpora t ion“. Item 3, line 4: De
7、lete “405ZT“ and substitute “408ZT“. Items 4 and 5, line 4: Delete “102V“ and substitute “104A5“. Item 6, line 5: Delete “102V“ and substitute “104A5“. PAGE 5 f: 3.4.3, line 2: Delete “table II.“ and substitute: “Part No. 892-185, Ozalid Corporation or equivalent and as specified in table II.“ f: 3.
8、4.3, Item 1, line 3: After “applicable“: Add “Part No. 892-400, Ozalid Corporation or equivalent.“ 9: 3.4.3, Item 2, line 2: Delete “GAF“ and substitute “Ozalid“. 3.6: Delete and substitute: “3.6 Marking. 3.6.1 Copier machine. The copier machine shall be marked for identification in accordance with
9、the manufacturers commercial practice except that the letter “M“ shall be added to the end of the model number. 3.6.2 Copier and expendable supplies carrying case. The copier and expend- able supplies carrying cases shall be marked in accordance with drawings 5-7-173 and 5-7-181 respectively.“ PAGE
10、6 4.3, line 3: Delete “4.5.4“ and substitute “4.5.6“. PAGE 8 4.4.2.3: Delete and substitute: “4.4.2.3 End item testing. 4.4.2.3.1 Speed testing. Each end item shall be tested as specified in 4.5.1. Any test failure shall be cause for rejection of the affected end item. 9 2 .- I Provided by IHSNot fo
11、r ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R-44023A (3) 3b 77977Ob 04bL785 1 MIL-R-44023A(CL) AMENDMENT 3 4.4.2.3.2 Color reproduction test. One out .of every ten end items shall be tested as specified in 4.5.5. Any test failure shall be cause for rejection of t
12、he lot.“ PAGE 9 4.5.4, after 1st sentence: Add “The transparent overlay material shall be in a 36 inch wide roll as specified in table I, item 4.“ Add the following new paragraphs: “4.5.5 Color reproduction test. The copier shall be run at the proper speed to reproduce 2 copies (8-1/2 by 11 inches)
13、of line drawing in each of the following separate colors (see 3.4.1): red, blue, sepia, green and black. Failure to reproduce in one or more colors shall be considered a test failure. 4.5.6 Vibration. The copier (see 3.4.1) mounted in the carrying case shall be subjected to the tests of method 514.2
14、, category f of MIL-STD-810 in accord- ance with procedure VIII, curve Y, figure 5.14.2-VI, The sinusoidal cycling time schedule shall be 1 hour duration in a horizontal plane. No test will be performed in a vertical plane.“ NOTE: Changes from the previous amendment. The margins of this amendment ar
15、e marked with an asterisk to indicate where changes (additions, modifications, corrections, deletions) from the previous amendment were made. This was done. as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are c
16、autioned to evaluate the requirements of this document based on the entire content irre- spective of the marginal notations and relationship to the last previous amendment. Custodian: Preparing activity: Army - GL Army - GL Review activity: (Project 3610-A378) Army - ME 3 1 I. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-