资源描述

1、1. SCOPE - MIL-T-55335 bb m 77777Ob OLL1Lb9b 5 m -1 /- -6 +-.O3 b, MIL-T-5 35 (EL) 30 August 197L 1.11 L ITARY SPEC II: I CA? TON TEST FACILITIIS .KIT NK-1191( )/AlE-8505 ( )/AR Adapter, FIX-8506 ( )/AR Adapter, MX-8507 ( )/AR Adapter, MX-8508 ( )/AR Adapter, ia-8509 ( )/AR Adapter, U-8510 ( )/AR Ad

2、apter, FIX-8511 ( ) /AR Adapter, m-8527 ( )/AR Resistance: Power Supply Term MX-( ) Power Supply Term Pa-( ) Power Supply Term MX-( ) Headset Term MX-( ) Plicrophone Term MX- ( ) Interchangeability REQT PARA - 3.13.34 3.13.35 3.13.36 3.13.37 3.13.38 3.13.39 3.13.40 3.13.41 3.13.42 3.13.43 3 13.44 3.

3、13.45 3.13 46 3.13.47 3.13.48 3.13.49 3.13.50 3.13.51 3.13.57 3.13.58 3.13.59 3.13.60 3.13.61 3.13.62 3.13.63 3.13.64 3.13.65 3.13.66 3.13.52 3.13.53 3.13.54 3.13.55 3.13.56 3.16 18 INSP PARA - 4.9.34 4.9.35 4.9.36 4.9.37 4.9.38 4.9.39 4.9.40 4.9.41 4.9.42 4.9.43 4.9.44 4.9.45 4.9.46 4.9.47 4.9.48 4

4、.9.49 4.9.50 4.9.51 4.9.57 4.9.58 4.9.59 4.9.60 4.9.61 4.9.62 4.9.63 4.9.64 4.9.65 4.9.66 4.9.52 4.9.53 4.9.54 4.9.55 4.9.56 4.11 1 1 6.5% for the Breakout Boxes and Adapters (combined ) 1 6.52 for the cables 6.5% for the Power Supply Terminations, Headset and Micro- phone (Combined) 6.5% for the In

5、terchangeability 1 Licensed by Information Handling Servicest MIL-T-55335 66 7797706 OL4L7LLi 3 9 MIL-T- 5 5 3 3 5 (EL) 4.5.3 Group C inspection. - This inspection shail be as listed in Table IV, and shall normally be performed on sample units that have been subject to and met Group A and B inspecti

6、on, allowed, Sample unit(s) shall be selected in accordance with 4.5.4. No defects shall be ! INSPECTION SUBGROUP I: Altitude Temperature Vibration Humidity SUBGROUP II: Spray tight protection Shock, bench-handling Shock, drop SUBGROUP III : TABLE IV - GROUP C INSPECTION REQT INSP PARA PARA - - 3.12

7、.3 4.8.3 3.12.1 4.8.1 3.12.6 4.8.6 3.12.2 4.8.2 3.12.4 4.8.4 3.12.7 4.8.7.1 3.12.7 4.8.7.2 Fungus 3.12.5 4.8.5 4.5.4 a. - Units selected for each Group C inspection shall be selected without regard to their quality in accordance with the following: 4.5.4.1 Subgroup I. - For this subgroup, two units

8、from the first 10 production units shall be selected for the first Group C inspection. For subsequent Group C: inspections, one unit from each successive 25 or fractions thereof shall be selected. 4.5.4.2 Subgroup II. - For this subgroup, two units from the first 10 production units shall be selecte

9、d for the first Group C inspection. For subsequent Group C inspections, one unit from each successive 50 or fractions thereof shall be selected. 19 Licensed by Information Handling ServicesMIL-T-55335 (EL) 4.5.4.3 Subgroup III. - For this subgroup, only one (i) unit(s) from the first 10 production u

10、nits shall be selected for the first Group C inspection, For subsequent inspections, one (i) unit(s) shall be selected when one half of the units on order have been accepted by the Governments QA Representative. 4.5.5 Noncompliance. - The contractor shall immediately report in writing each Group C f

11、ailure occurrence, including details of the failure and characteristics affected. The contractor shall immediately investi- gate the cause of failure and further report the results of investigation and details of the proposed corrective action on (i) the process and mater- ials, as applicable, and (

12、ii) all units of product which were manufactured under the same conditions and which the Government considers subject to the same failure, Reports shall be forwarded to the responsible technical activity designated in the contract through the Quality Assurance Repre- sentative. After corrective acti

13、on has been taken, additional sample units shall be subjected to Group C inspection (all inspections, or the inspections which the sample failed, at the option of the Government) and Group A and B inspection may be reinstituted; however, final acceptance and shipment will be withheld until the Group

14、 C re-inspection results have shown that the corrective action was effective. (See 6.4) 4.5.6 Reinspection of conforming Group C sample units. - Unless otherwise specified, sample units which have been subjected to and passed Group C inspection may be delivered on the contract or order, provided all

15、 damage is repaired, cleaned of all foreign matter, and the sample units are resubjected to and pass Group A inspection. 4.6 Bounce preconditioning. - The.Facilities Kit shall be placed in its normal operating position on a L.A.B. ARC-30-200 vibration table or suitable equivalent. and subjected to a

16、 two (2) minutes vibration. be approximately lg at 25 Hz. After bounce preconditioning, the unit shall not be repaired, aligned, cleaned, or otherwise changed prior to subjection to acceptance inspection. The unit shall be secured to the vibration table The vibration force shall 4.7 Standard test co

17、nditions. - spection shall be performed at normal humidity . Unless otherwise specified, all in- room temperature, pressure, and I ! 20 Licensed by Information Handling ServicesMIL-T-55335 bb W 97777Ob Ollr171ib 7 I MIL-T-55335 (EL) 4.8 Service conditions. - The service condition tests shall be cond

18、ucted as specified. When electrical tests ,are required, the equipment shall meet the requirements of 3.13.1 thru 3.13.68, Upon completion of each service condition test, the equipment shall be subjected to and pass a visual and mechanical inspection. No defects will be allowed. 4.8.1 Temperature (S

19、ee 3.121). - i 4.8.1.1 Operating. - The equipment shall be subjected to the tempera- ture limits in accordance with Methods 501 and 502 of MIL-STD-810, Tests shall be conducted at ambient before and after the temperature tests, and at extreme temperatures when the temperature limits have been reache

20、d, requirements of 3.12,l.l shall be met. The 4.8.1.2 Non-operating. - The equipment shall be subjected to the temperature limits in accordance with Methods 501 and 502 of MIL-STD-810, Electrical tests shall be conducted at ambient before and after the tem- perature tests. The requirements of 3.12.1

21、.2 shall be mt. 4.8.2 Humidity. - The equipment shall be subjected to and meet the humidity test of Specification MIL-T-5422 with the transit case open. upper and lower hold down plate assemblies shall be removed from transit case and placed in the chamber. tests shall be performed before and after

22、the humidity test. ments of 3.12.2 shall be met. The Mechanical-Visual inspection and electrical The require- 4.8.3 Altitude. - The equipment shall be subjected to the altitude tests in accordance with Procedure 1, Method 500, of MIL-STD-810. Electrical tests shall be conducted before and after the

23、altitude test at ambient pressure and at 10,000 feet, the unit(s) shall not be required to operate. The interior of The unit(s) shall be subjected to the test 21 Licensed by Information Handling ServicesMIL-T-55335 (EL) 4.8.6 Vibration. - The equipment shall be subjected to the vibration test in acc

24、ordance with Method 514-1.of MIL-STD-180, except the equipment shall not be operated during vibration, conducted before and after the vibration test. in the test fixture on the vibration table, determine resonant modes of the maintenance kit by varying the frequency of applied vibration slowly throu

25、gh the specified range at an amplitude not exceeding that for which the equipment is to be tested. conducted with vibration applied along each of the three Orthogonal axes of the equipment. completion of the vibration tests. met. Electrical tests shall be With the equipment mounted Individual resona

26、nce surveys shall be Electrical tests shall be conducted after the The requirements of 3.12.6 shall be 4.8.7 Shock. - 4.8.7.1 Shock, bench-handling (See 3.12.7). - The chassis-with-front- panel assembly shall be removed from its combination case, as for servic- ing, and placed in a suitable position

27、 for servicing on a solid, 2-inch fir bench top. The test shall be performed as follows, in a manner simulating shocks liable to occur during servicing: a. Tilt up the assembly through an angle of 30 degrees, using one edge of the assembly as an axis, and permit the assembly to drop back freely to t

28、he horizontal, Repeat, using other practicable edges of the same horizontal face as axes, for a total of four drops. b. Repeat “a“, with the assembly resting on other faces, until it has been dropped for a total of four times on each face on which the assembly might practically be placed during serv

29、icing. Electrical tests shall be conducted after completion of the bench-handling test. 4,8.7,2 Shock, drop. - The equipment in its transit case shall be subjected to 18 impact shocks of 15g. consisting of 3 shocks in opposite directions along each of 3 mutually perpendicular axes, each shock impuls

30、e having a time duration of 11 + 1 milliseconds. Except for abrasion, paint chipping, and small locl deformations, no damage shall occur. Upon completion of the test, without adjustment or repair, the equipment shall be tested for compliance with 3.12.7. 4.9 Electrical requ.irements. - 4.9.1 Adapter

31、, Breakout Box MX-( ). - Check the continuity of each wire between the applicable terminals and test points in accordance with SM-B-625701, to determine compliance with 3.13.1. 22 Licensed by Information Handling Services- NIL-T-55335 bb 77779Ob OL417LB O i wire with wire with wire with 4.9.2 betwee

32、n the applicable terminals and test points in accordance SM-B-625706, to determine compliance with 3.13.2. Adapter, Breakout Box MX-( ). - Check the continuity of each 4.9.3 between the applicable terminals and test points in accordance SM-B-625711, to determine compliance with 3.13.3. Adapter, Brea

33、kout Box MX-( ). - Check the continuity of each 4.9.4 between the amlicable terminals and test points in accordance Adapter, Breakout Box MX-( ). - Check the continuity of each _ SM-B-625716, ; determine compliance with 3.13.4. 4.9.5 between the 4.9.6 between the 4.9.7 between the 4.9.8 between the

34、4.9.9 between the 4.9.10 between the 4.9.11 between the 4.9.12 between the Cable, CX-10894( )/U. - Check the continuity of each wire applicable pins to determine compliance with 3.13.5. Cable, CX-12182( )/U. - Check the continuity of each wire applicable pins to determine compliance with 3.13.6. Cab

35、le, CX-12183( )/U. - Check the continuity of each wire applicable pins to determine compliance with 3.13.7. Cable, CX-12184( )/U . - Check the continuity of each wire applicable pins to determine compliance with 3.13.8. Cable, CX-12185( )/U. - Check the continuity of each wire applicable pins to det

36、ermine compliance with 3.13.9. Cable, CX-12186( )/U. - Check the continuity of each wire applicable pins to determine compliance with 3.13.10. Cable, CX-12187( )/%i - Check the continuity of each wire applicable pins to determine compliance with 3.13.11. Cable, CX-12188( )/U. - Check the continuity

37、of each wire applicable pins to determine compliance with 3.13.12. 4.9.13 Cable, CX-12189( )/U. - Check the continuity of each wire between the applicable pins to determine compliance with 3.13.13. 4.9.14 Cable, CX-12190.( )/U. - Check the continuity of each wire between the applicable pins to deter

38、mine compliance with 3.13.14. 4.9.15 Cable, CX-12191( )/U . - Check the continuity of each wire between the applicable pins to determine compliance with 3.13.15. 23 Licensed by Information Handling ServicesMIL-T-55335 66 7777706 OLqL717 2 W .I MIL-T-55335 (EL) 4.9.16 Cable, CX-12192( )/U. - Check th

39、e continuity of each wire between the applicable pins to determine compliance with 3.13.16. 4.9.17 Cable Assembly, Headset CX-( ). - Check the continuity of each wire between the applicable terminals in accordance with SM-B-625791, to determine compliance with 3.13.17. 4.9.18 Cable, CX-3475( )/U. -

40、Check the continuity of each wire between the applicable terminals to determine compliance with 3.13.18. 4.9.19 Power Supply Termination MX-( ). - Check the continuity of each wire between the applicable terminals in accordance with SM-B-625877, to determine compliance with 3.13.19 4.9.20 Power Supp

41、ly Termination MX-( ). - Check the continuity of each wire between the applicable terminals in accordance with SM-B-625879, to determine compliance with 3.13.20. 4.9.21 Power Supply Termination BE-( ). - Check the continuity of each wire between the applicable terminals in accordance with SM-B-62579

42、2, to determine compliance with 3.13.21. 4.9.22 Headset Termination MX-( ). - Check the continuity of each wire between the applicable terminals in accordance with SM-B-625790, to determine compliance with 3.13.22. 4.9.23 Microphone Termination MX-( ). - Check the continuity of each wire between the

43、 applicable terminals in accordance with SM-B-625789, to determine compliance with 3.13.23. 4.9.24 Adapter, MX-8503( )/AR. - Check the continuity of each trace between the applicable terminals to determine compliance with 3.13.24. 4.9.25 Adapter, MX-8504( )/AR. - Check the continuity of each trace b

44、etween the applicable terminals to determine compliance with 3.13.25. 4.9.26 Adapter, MX-8505( )/.AR. - Check the continuity of each trace between the applicable terminals to determine compliance with 3.13.26. 4.9.27 Adapter, MX-8506( )/AR. - Check the continuity of each trace between the applicable

45、 terminals to determine compliance with 3.13.27. 4.9.28 Adapter, MX-8507( )/AR. - Check the continuity of each trace between the applicable terminals to determine compliance with 3.13.28. 24 ! Licensed by Information Handling ServicesMIL-T-55335 bb m 77777Ob O/VL720 7 m 4.9.29 Adapter, MX-8508( )/AR

46、. - Check the continuity of each trace between the applicable terminals to determine cgmpliance with 3.13.29. 4.9.30 Adapter, MX-8509( )/AR. - Check the continuity of each trace between the applicable terminals to determine compliance with 3 . 13.30. 4.9.31 Adapter, MX-8510( )/AR. - Check the contin

47、uity of each trace betweenthe applicable terminals to determine compliance with 3.13.31. 4.9.32 Adapter, MX-8511( )/AR. - Check the continuity of each trace between the applicable terminals to determine compliance with 3.13.32. 4.9.33 Adapter, MX-8527( )/AR. - Check the continuity of each trace betw

48、een the applicable terminals to determine compliance with 3.13.33. 4.9.34 Adapter, Breakout Box MX-( ). - Apply the voltage specified in Table V, measure the insulation resistance in accordance with SM-B- 625701 to determine compliance with 3.13.34. 4.9.35 Adapter, Breakout Box MX-( ), - Apply the v

49、oltage specified in Table V, measure the insulation resistance in accordance with SH-B- 625706 to determine compliance with 3.13.35. 4.9.36 Adapter, Breakout Box PE-( ). - Apply the voltage specified in Table V, measure the insulation resistance in accordance with SM-B- 625711 to determine compliance with 3.13.36. 4.9.37 Adapter, Breakout Box_MX-( ). - Apply the voltage specified in Table V, measure the insulation-resistance in accordance with SM-B- 625716 to determine compliance with 3.13.37. 4.9.38 Cable, CX-10894( )/AR. - Apply 100 VDC, measure the insula- tion resistance bet