1、- . =.- -. c-. I. 1 HIL-W-63LI52 (8) 33 9 7777906 0350830 3 9 S-3Tdb-7 -. MIL-W-63452 (AR) - - AMENDMENT 8 18 November 1988 SUPERSEDING AMENDMENT 7 14 April 1986 MILITARY SPECIFICATION WARHEAD, GUIDED MISSILE, HE, M207E2 BODY AND BOATTAIL BUSHING FOR This Amendment forms a part of Military Specifica
2、tion MIL-W-63452 (AR) dated 17 June 1981 and is approved for use within the U.S. Army Armament, Munitions and Chemical Command and is-available for use by all Depaxtments and Agencies of the Department of Defense. In the specification, wherever “M207E2“ appears add “and M207E5“. This change is appli
3、cable to page 1 (2 places) and pages 4 and 9 (1 place) In the specification, wherever “9340751“ appears delete this number and substitute “9340751-1 or 9340751-2“. This change is applicable to page 2 (2 places) and pages 3, 4, 5, 6, 7 and 9 (1 place). In the specification, wherever “M207E2“ and “M20
4、7E5“ appears, add “M207E6“. This change is applicable to page 1, (2 places) and pages 4 and 9 (1 place) PAGE 6 J( 4.4.2.1 Major 101: Delete in its entirety and substitute the following: “101 Runout of taper with datums A and B 0.40%.3.2 . . .Gage“ 4.4.2.1 Major 103: Add “See Note 1“ at the end of se
5、ntence. At bottom of page add Note 1 as follows: “Note 1. I.D. shall be inspected for entire length“. * 4.4.2.1 Major 110:. Delete in its entirety and substitute the E o 1 low i ng : “110 Profile of taper between X and Y 0.40%.3.2 Major 116: Delete “AQL 0.40% and substitute “100%“. . . age“ AMSC N/A
6、 1 of 3 FSC 1336 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. -s ._ Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-_- - _- MIL-W-63452 () 33 m 7777906 0350833 5 m - .J_c- .?i -.- MIL-W-63452 (AR) Amendment 8 PAGE
7、 7 4.4.2.1 Add Major defect 122 as follows: “122 Evidence of raised hanging burrs, on exit hole surface of 6 threaded holes, loo%, 3.2, 1OX Magnifier.“ 4.4.2.1 Add Major defect 123 as follows: “123 Minor diameter of small aft threads, max., loo%, 3.2, Gage.“ Minor 205: Delete in its entirety. 4.4.2.
8、1 Minor 208: Delete and substitute: “208 - Protective finish missing, damaged or incomplete“. 4.4.2.1 Add Minor defects 213, 214 and 215 as follows: “213 Radius on conduit slot, 0.65%, 3.2, Gage. 214 Distance to conduit surface, 0.658, 3.2, Gage. 215 Angle of conduit surface, 0.65%, 3.2, Gage“. PAGE
9、 8 4.4.2.2 Add Major defect 107 as follows: “107 Smallest outside diameter, 0.40%, 3.2, Gage.“ PAGE 9 Add 4.5.2 as follows: “4.5.2 Molded components. At the start of production from a new mold, or repair to a mold or cavity, consecutively produced units from each mold or cavity shall be dimensionall
10、y examined until 4 consecutive units meet all applicable drawing requirements. repair, those dimensions affected by the adjustment or repair shall similarly be examined. During production, the molding procedures shall be monitored randomly every two hundred units for uniformity of molding practices.
11、 Suspected deviations in mold product shall be examined to determine if corrective action OK mold repair is required.“ After adjustment or 2 -. . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-U c MIL-U-63452 () 13 3737706 0350832 7 m -_ _ - - MIL-W
12、-6345 2 (AR) Amendment 8 NOTE: The margins of this amendment are marked with an asterisk or vertical line to indicate where changes (additions, modifications, corrections, deletions) amendment were made. the Government assumed no liability whatsoever for any inaccuracies in these notations. cautione
13、d to evaluate the requirements of this document in relationship to the last previous amendment. from the previous This was done as a convenience only and Bidders and contractors are Custodian: - Army-AR Preparing activity: Army-AR (Project 1336-AS91) t 3 -. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-