1、00-I-675F (3) 35 W 7979774 0024625 O 00-I-675F AMENDMENT-3 September 12, 1977 SUPERSEDING Int. mendment-2 (AW-GL) November 13, 1975 and Amendment-1 April 22, 1975 FEDERAL SPECIFICATION IRONERS, FLATWORK, COMMERCIAL (AND ACCESSORIES) * This amendment which forms a part of Federal Specification 00-1-6

2、75, dated November 20, 1973, was approved by the Cdssioner, Federal Supply Service, General Services Administration, for the use of all Federal agencies. 1 PAGE 2 1.2.2, Item &A, at the end of the first line: Delete “crossfolder (luiti- lane) and subs titute “cross folder ( single-lane . PAGE 3 2.1,

3、 under “Military Standards“: Add “MIGSTD-lb74 - Noise Limits for - Amy Materiel“. PAGE 4 3.1: Delete in its entirety. .PAGE 5 3.3.1: Delete lines 1 and 2 and substitute “Prior to commencing production, the supplier shall submit to“, PAGE 8 Add in proper sequence: “3.5.11 Noise limits. The ironer sha

4、ll meet the noise limits specified in MILSTD-1474 and, where practicable, shall not exceed 85 decibels A-weighted at the normal operator position. FSC 3510 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-00-I-675F (3) 35 m 7777774 0024626 2 .I - PAGE

5、 12 3.7: = fied in 3.6“. Add “The following items shall be ccmpatible with the ironers speci- PAGE 13 or non-adjustable, solidly attached to the freme of the folder) top height shall be 27-3/4 inches minimum to 33-3/4 inches maximum from the floor.“ 3.7.2.3, last sentence: Delete and substitute #The

6、 table (when adjustale = PAGE 14 3.7.3.1.5, line 3: Add “The delivery table (when adjustable or non- adjustable, solidly attached to the frame of the folder) tap height shall be 27-3/4 inches minimum to 33-3/4 inches maximum from the floor.“ PAGE 20 * 4.2: Delete “I. First article inspection (see 4.

7、3).“ 4.3: Delete in its entirety. PAGE 24 4.4.2.3: Delete in its entirety and substitute: 4.4.2.3 End iten testing. Smple ironers and accessory items, as applic- able, shall be tested as specified in 4.7.1 and 4.7.2 using inspection level S-2. 0e applicable tests specified in 4.7.3.1 through 4.7.5 s

8、hall be performed on one production unit. Failure of any test shall be cause to - reject the lat. PAGE 26 .- 4.7.3.2: “4.7.3.2 Crocsfolder. Connect the crossfolder to electric power and air supply and feed full size folded bed sheets through the machine for one hour at a minimum rate of 70 linear fe

9、et per minute, and in conjunction with accessories of normal use. requirements specified in 3.7.2 shall constitute failure of the test.“ Delete in its entirety and substitute: i Inability of the folding machine to meet the t L = + 2 - Provided by IHSNot for ResaleNo reproduction or networking permit

10、ted without license from IHS-,-,-.- -. - c- r c - c i - r 4.7.3.4: Delete in its entirety and substitute 00-1-67 5F AMENDMENT93 PAGE 27 7.3.4 Folding machine with bui It-in cross f older. Connect the machine to the specified electric parer source and sir supply and feed full size bed sheets at a min

11、imum. rate of 70 linear feet per minute through the machine for one hour. This test shall be performed in conJunction with accessories of normal use. Inability of the folding machine to meet the requirements specified in 3.7.4 shall constitute failure of the test.“ - PAGE 28 Add in proper sequence:

12、“4.7.5 Noise test. The ironer shell be tested - for confonnance with the noise limits of 3.5.11 in accordance with NIL-STlL1474 I . PAGE 29 6,2(d): Delete in its entirety. PAGE 30 .- 6.5: Delete in its entirety. custodians : - Army - GL Navy - YD Air Force -. 99 Review activity : _. .= - - m-m ._ EA- Gc _*. .- .- User activities : Preparing activity : Am - GL Civil Agency Coordinating Activities : GSA - FSS VA - DMC Project lia. 3510-0266 . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-