1、*USACE / NAVFAC / AFCESA / NASA UFGS-08 34 53 (August 2008)-Preparing Activity: USACE SupersedingUFGS-08 34 53 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2007*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08 34 53SECURITY DOORS AND FR

2、AMES08/08PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 DELIVERY, STORAGE, AND HANDLINGPART 2 PRODUCTS2.1 VAULT DOOR UNIT2.2 Doors2.3 Frames and Sills2.4 Day GatePART 3 EXECUTION3.1 INSTALLATION- End of Section Table of Contents -SECTION 08 34 53 Page 1Provided by IHSNot for ResaleNo reproduction or

3、networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-08 34 53 (August 2008)-Preparing Activity: USACE SupersedingUFGS-08 34 53 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2007*SECTION 08 34 53SECURITY DOORS AND

4、 FRAMES08/08*NOTE: This guide specification covers the requirements for non-security type fire-insulated record-vault doors.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate inf

5、ormation.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including t

6、heir organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publicatio

7、ns are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Art

8、icle. Also use the Reference Wizards Check Reference feature to update SECTION 08 34 53 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-the issue dates.References not used in the text will automatically be deleted from this section of the proje

9、ct specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.UNDERWRITERS LABORATORIES (UL)UL 140 (2006;

10、Rev thru Jan 2008) Standard for Relocking Devices for Safes and VaultsUL 155 (2005) Standard Tests for Fire Resistance of Vault and File Room DoorsUL 768 (2006; Rev thru Mar 2007) Standard for Combination Locks1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUB

11、MITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are alread

12、y marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Arm

13、y projects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or

14、 other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second

15、bracketed item for Army projects.*SECTION 08 34 53 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control

16、 approval.information only. When used, a designation following the “G“ designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsVault Door UnitDoorsDay GateFrames and SillsHar

17、dwareInstallation drawings which include details of construction, method of anchorage and type and location of the following: Vault Door Units, Hardware, Frames and Sills, and Day GateSD-03 Product DataVault Door UnitDoorsDay GateFrames and SillsManufacturers descriptive data and catalog cuts. Prepr

18、inted installation instructions.SD-07 CertificatesVault Door UnitFrames and SillsHardwareCertificates certifying that the vault-door unit, frames, sills, and hardware furnished under this specification conforms with the referenced standards contained in this section and to the requirements of the Un

19、derwriters Laboratories. The label or listing of the Underwriters Laboratories, for fire-resistance classification and safety-relocking devices is acceptable as sufficient evidence that the vault-door unit conforms to these requirements. In lieu of such label or listing, submit a written certificate

20、 from any nationally recognized testing agency adequately equipped and competent to perform such services, stating that the vault-door unit has been tested and that this unit conforms to the requirements listed herein, including methods of testing of the Underwriters Laboratories, Inc.1.3 DELIVERY,

21、STORAGE, AND HANDLINGDeliver, store and handle doors and frames in a manner that prevents damage.PART 2 PRODUCTS2.1 VAULT DOOR UNITProvide an insulated, steel, flat-sill, record-vault-type door with frame that is a standard product of a manufacturer specializing in this type of SECTION 08 34 53 Page

22、 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-construction.2.2 Doors*NOTE: When the required clear opening for the door is in excess of 1000 mm (40 inches) in width, a pair of doors must be used.*Design and construction of doors shall be manufact

23、urers standard with a UL 155 fire-resistant classification for a 6-hour 4-hour 2-hour exposure rating, bearing the UL label on the door and frame for the exposure rating required. Provide doors of the size indicated. The finish for door, frame, and hardware shall be the manufacturers standard for th

24、e type door indicated. Provide each door equipped with a relocking device conforming to UL 140 and with an inner escape device that permits the bolt work to be released from inside the vault. Escape mechanism to be panic bar type or other approved type requiring no tools or special instructions for

25、operation.Printed instructions for operating the escape device shall be provided inside the vault near the escape device release. Hardware shall meet the following specifications:a. Provide not less than 5 bolts for the doorfive bolts for each side of the door. Each bolt shall be not less than 17 mm

26、 11/16 inch in diameter, permanently lubricated. When the bolts are not located on both jamb sides of the door, the jamb side not provided with bolts shall interlock with the frame walls of that side. Exposed bolt work shall be corrosion resistant or nickel plated steel.b. Provide each door with not

27、 less than three heavy, offset roller or ball bearing steel hinges, unless noted otherwise on the drawings.c. Each door shall have a combination lock that complies with UL 768, Group 1R, for combination locks. Provide locking mechanism operated by means of a lever handle. Locks shall be combination

28、3 or 4 tumbler, key or hand-changing type with metal cases protected by drill-resistive steel plates and operated by lever handles. The front-plate of the doors shall be not lighter than 1.5 mm 0.060 inch steel plate either riveted or welded to the edge plates. Edge plates and back plates of doors s

29、hall be not lighter than 0.81 mm 0.032 inch steel. Lock shall be highly resistant to expert manipulation conforming to UL 768, Group I, combination locks.reasonably resistant to unauthorized opening conforming to Group II of UL 768 combination locks.2.3 Frames and SillsProvide frames of the tongue-a

30、nd-groove interlocking type, constructed of not lighter than 1.2 mm 0.0478 inch cold-formed steel, formed from a single length for each jamb and a single length for the head. Head and jambs shall be continuously welded along the entire intersection. Sills shall be flat and not less in width than the

31、 jambs. Provide frame, jambs and heads insulated with the same material as the door. The frame shall be designed for the thickness of vault wall indicated.2.4 Day Gate*NOTE: If no day gate is required, omit this SECTION 08 34 53 Page 5Provided by IHSNot for ResaleNo reproduction or networking permit

32、ted without license from IHS-,-,-paragraph in its entirety.*The vault door unit shall include a day gate of the manufacturers standard make, and the door frame designed to accommodate this day gate. The gate shall be of the swing-in, hinged type, with not less than 15 mm 5/8 inch diameter rods, and

33、the gate frame of not less than 10 mm 3/8 inch by 31 mm 1-1/4 inch aluminum or steel members. Provide the day gate equipped with a locking device arranged to permit locking and unlocking of the gate from the inside only. Finish of the day gate shall be the manufacturers standard. The day gate shall

34、not interfere with the operation of the inner escape device.PART 3 EXECUTION3.1 INSTALLATION*NOTE: If carpet is to be installed in front of the door, increase the height of the wall opening by the combined thickness of the carpet and pad.*Install the vault door unit in strict compliance with the app

35、roved installation instructions and drawings provided by the manufacturer. Install the day gate in a manner that does not interfere with operation of the release handle on the inside of the vault door. After installation, adjust the door, the locking mechanism, and the inner escape for proper operation.- End of Section -SECTION 08 34 53 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-