ARMY UFGS-08 60 45-2012 [SKYLIGHTS][ AND ][TRANSLUCENT PANELS].pdf

上传人:吴艺期 文档编号:449585 上传时间:2018-11-16 格式:PDF 页数:16 大小:72.28KB
下载 相关 举报
ARMY UFGS-08 60 45-2012 [SKYLIGHTS][ AND ][TRANSLUCENT PANELS].pdf_第1页
第1页 / 共16页
ARMY UFGS-08 60 45-2012 [SKYLIGHTS][ AND ][TRANSLUCENT PANELS].pdf_第2页
第2页 / 共16页
ARMY UFGS-08 60 45-2012 [SKYLIGHTS][ AND ][TRANSLUCENT PANELS].pdf_第3页
第3页 / 共16页
ARMY UFGS-08 60 45-2012 [SKYLIGHTS][ AND ][TRANSLUCENT PANELS].pdf_第4页
第4页 / 共16页
ARMY UFGS-08 60 45-2012 [SKYLIGHTS][ AND ][TRANSLUCENT PANELS].pdf_第5页
第5页 / 共16页
亲,该文档总共16页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、*USACE / NAVFAC / AFCESA / NASA UFGS-08 60 45 (February 2012)-Preparing Activity: USACE SupersedingUFGS-08 62 00 (August 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2012*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08 60 45SKYLIGHTS AND T

2、RANSLUCENT PANELS02/12PART 1 GENERAL1.1 SUMMARY1.2 REFERENCES1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.5 DELIVERY, STORAGE, AND HANDLING1.6 WARRANTYPART 2 PRODUCTS2.1 SKYLIGHTS AND TRANSLUCENT PANELS2.2 GLASS-FIBER PANELS2.2.1 Weatherability2.2.2 Non Combustible Grid Core2.2.3 Adhesive2.2.4 Panel Constru

3、ction2.3 THERMOPLASTIC POLYCARBONATE PANELS2.4 COMMON PANEL REQUIREMENTS2.4.1 Appearance2.4.2 Panel Fabrication2.4.3 Thermal Performance2.4.4 Condensation Index Rating2.5 SKYLIGHT AND TRANSLUCENT PANEL SYSTEMS2.5.1 Glass Glazed Skylights and Roof Windows2.5.2 Plastic Glazed Unit Skylight and Translu

4、cent Panels2.5.2.1 Dome2.5.2.2 Pyramid2.5.2.3 Vault2.5.3 Framed Skylights andTranslucent Panels2.6 FLEXIBLE SEALING TAPEPART 3 EXECUTION3.1 EXAMINATION3.2 ERECTIONSECTION 08 60 45 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- End of Section

5、Table of Contents -SECTION 08 60 45 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-08 60 45 (February 2012)-Preparing Activity: USACE SupersedingUFGS-08 62 00 (August 2009)UNIFIED FACILITIES GUIDE SPECIFICA

6、TIONSReferences are in agreement with UMRL dated January 2012*SECTION 08 60 45SKYLIGHTS AND TRANSLUCENT PANELS02/12*NOTE: This guide specification covers the requirements for skylights and translucent panels manufactured from glass-fiber or thermoplastic polycarbonate.Adhere to UFC 1-300-02 Unified

7、Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or inse

8、rt appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL1.1

9、SUMMARYProvide commercially available roof windows unit skylights flat glass domed pyramidal vaulted metal or wood framed skylights which satisfy all requirements contained in this section and have been verified by load testing and independent design analyses (if required) to meet specified design r

10、equirements. Provide environmentally preferable products and work practices, applicable to skylights, considering raw materials acquisition, production, manufacturing, packaging, distribution, reuse, operation, maintenance, and/or disposal of the products or services used in the skylights. The skyli

11、ght system shall be UV-stabilized, shatter proof and energy efficient. The plastics used in the manufacture of the skylights shall be light transmitting plastics for daylighting applications. Systems shall meet requirements of UFC 4-010-01.SECTION 08 60 45 Page 3Provided by IHSNot for ResaleNo repro

12、duction or networking permitted without license from IHS-,-,-1.2 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designa

13、tion, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in

14、the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by th

15、e basic designation only.ALUMINUM ASSOCIATION (AA)AA DAF45 (2003; Reaffirmed 2009) Designation System for Aluminum FinishesAMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)AAMA 2603 (2002) Voluntary Specification, Performance Requirements and Test Procedures for Pigmented Organic Coatings on A

16、luminum Extrusions and PanelsAAMA 2604 (2005) Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and PanelsAAMA 2605 (2005) Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Or

17、ganic Coatings on Aluminum Extrusions and PanelsAAMA 611 (1998; R 2004) Voluntary Specification for Anodized Architectural AluminumAAMA/WDMA 1600/I.S. 7-00 (2000; Errata 2003; R 2003) Voluntary Specification for SkylightsASTM INTERNATIONAL (ASTM)ASTM C297/C297M (2004; R 2010) Flatwise Tensile Streng

18、th of Sandwich ConstructionsSECTION 08 60 45 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ASTM D1002 (2010) Apparent Shear Strength of Single-Lap-Joint Adhesively Bonded Metal Specimens by Tension Loading (Metal-to-Metal)ASTM D1003 (2011) Ha

19、ze and Luminous Transmittance of Transparent PlasticsASTM D1037 (2006a) Evaluating Properties of Wood-Base Fiber and Particle Panel MaterialsASTM D1929 (2011) Standard Test Method for Determining Ignition Temperature of PlasticsASTM D2244 (2011) Calculation of Color Tolerances and Color Differences

20、from Instrumentally Measured Color CoordinatesASTM D2843 (2010) Density of Smoke from the Burning or Decomposition of PlasticsASTM D3841 (1997; R 2008e1) Standard Specification for Glass Fiber-Reinforced Polyester Plastic PanelsASTM D572 (2004; R 2010) Rubber Deterioration by Heat and OxygenASTM D63

21、5 (2010) Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Self-Supporting Plastics in a Horizontal PositionASTM E108 (2011) Fire Tests of Roof CoveringsASTM E283 (2004) Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified

22、 Pressure Differences Across the SpecimenASTM E330 (2002; R 2010) Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure DifferenceASTM E331 (2000; R 2009) Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Sta

23、tic Air Pressure DifferenceASTM E661 (2003; R 2009) Standard Test Method for Performance of Wood and Wood-Based Floor and Roof Sheathing Under Concentrated Static and Impact LoadsASTM E695 (2003; R 2009) Measuring Relative Resistance of Wall, Floor, and Roof SECTION 08 60 45 Page 5Provided by IHSNot

24、 for ResaleNo reproduction or networking permitted without license from IHS-,-,-Construction to Impact LoadingASTM E72 (2005) Conducting Strength Tests of Panels for Building ConstructionASTM E84 (2011b) Standard Test Method for Surface Burning Characteristics of Building MaterialsICC EVALUATION SER

25、VICE, INC. (ICC-ES)ICC-ES AC04 (2009) Acceptance Criteria for Sandwich PanelsINTERNATIONAL CODE COUNCIL (ICC)ICC UBC (1997; Erratas Vol 1, 2 Vol 1 Vol 2 10/2001) Uniform Building CodeNATIONAL FENESTRATION RATING COUNCIL (NFRC)NFRC 100 (2010) Procedure for Determining Fenestration Product U-FactorsNF

26、RC 200 (2010) Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal IncidenceU.S. DEPARTMENT OF DEFENSE (DOD)UFC 4-010-01 (2003; Change 1 2007) DoD Minimum Antiterrorism Standards for BuildingsU.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION

27、(NARA)29 CFR 1910.23 Guarding Floor and Wall Openings and HolesUNDERWRITERS LABORATORIES (UL)UL 972 (2006; Reprint Jul 2011) Standard for Burglary Resisting Glazing Material Type1.3 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the f

28、ollowing list to reflect only the submittals required for the project.The Guide Specification technical editors have designated those items that require Government approval, due to their complexity or criticality, with a “G.“ Generally, other submittal items can be reviewed by the Contractors Qualit

29、y Control System. Only add a “G” to an item, if the submittal is sufficiently important or complex in context of SECTION 08 60 45 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-the project.For submittals requiring Government approval on Army p

30、rojects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or ot

31、her organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bra

32、cketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval. information only. When used, a designation following the “G“ designation identifies the office that will review t

33、he submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsShop Drawings; G; G, _SD-03 Product DataSKYLIGHTS AND TRANSLUCENT PANELS; G; G, _WarrantySD-06 Test ReportsTest ReportsSD-07 CertificatesSystemsQualifications1.4 QUALITY

34、ASSURANCEa. Provide documentation of Qualifications for the following: The manufacturer shall be a company specializing in the manufacture of the specified products with a minimum of 5 10 years documented experience. The installer shall have documented experience of 5 _ years minimum performing the

35、work specified.b. Before fabrication, provide a full service mock-up of each type of skylight one skylight unit _ complete with glass and AAMA certification label for structural purposes and NFRC temporary and Permanent Label for certification of thermal performance rating for review of skylight con

36、struction and quality of hardware operation. Glass and glazing shall conform to the applicable requirements of SECTION 08 60 45 Page 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Section 08 81 00 GLAZING.1.5 DELIVERY, STORAGE, AND HANDLINGSystem m

37、odules shall be factory assembled to the greatest extent possible. Panels shall be shipped to the jobsite in rugged shipping units and shall be ready for erection. All skylights shall have conspicuous decals affixed warning individuals against sitting or stepping on the units. Skylight panels shall

38、be stored on the long edge, several mm inches above the ground, blocked and under cover to prevent warping. Deliver unit skylights in manufacturers original containers, dry, undamaged, with seals and labels intact. All products shall be delivered, stored and protected in accordance with manufacturer

39、s recommendations.1.6 WARRANTYProvide to the Government the manufacturers complete warranty for materials, workmanship, and installation. The warranty shall be for 5 _ years from the time of project completion and shall no be prorated. The warranty shall guarantee, but shall not be limited to, the f

40、ollowing:a. Light transmission and color of the panels shall not change after exposure to heat of 149 degrees C 300 degrees F for 25 minutes. In accordance with ASTM D2244, panels shall not darken more than 3.0 Delta E units after 5 years of outdoor weathering in South Florida at 45 degrees facing s

41、outh. Document compliance with this requirement in submitted Test Reports.b. There is no delamination of the panel affecting appearance, performance, weatherability or structural integrity of the panels or the completed system.c. There is no fiberbloom on the panel face.d. Change in light transmissi

42、on of no more than 6 percent in accordance with ASTM D1003, and in color (yellowing index) no more than 10 points in comparison to the original specified value over a 10 year period.e. Provide a single source warranty for the glazing panels and the framing system. Third party warranty for the glazin

43、g panels will not be accepted.PART 2 PRODUCTS2.1 SKYLIGHTS AND TRANSLUCENT PANELS*NOTE: A polyvinyl fluoride film coating may be specified for the exterior surface of skylight panels when longer wearability is considered necessary. For fire rated construction, panels with fire ratings consistent wit

44、h the overall construction of the building should be specified. Retain appropriate bracketed statements and corresponding paragraphs below and delete the others.The designer must consider the differences and performance characteristics of the two materials: SECTION 08 60 45 Page 8Provided by IHSNot

45、for ResaleNo reproduction or networking permitted without license from IHS-,-,-glass-fiber reinforced polyester and extruded cellular thermoplastic polycarbonate before making the selection to meet specific project requirements.*Skylight panels shall be fabricated of glass-fiber reinforced polyester or extruded cellular thermoplastic polycarbonate panels conforming to the specified requirements and other appropriate lab test