1、*USACE / NAVFAC / AFCESA / NASA UFGS-12 65 00 (August 2008)-Preparing Activity: USACE SupersedingUFGS-12 65 00 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2008*SECTION TABLE OF CONTENTSDIVISION 12 - FURNISHINGSSECTION 12 65 00FIXED SEATING08/08
2、PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 QUALITY ASSURANCE1.3.1 Warranty1.3.2 Certified Installers and Licensed Electricians1.4 DELIVERY, STORAGE, AND HANDLINGPART 2 PRODUCTS2.1 MATERIALS2.1.1 Upholstery Fabric2.1.2 Polyurethane Foam2.1.3 Plywood2.1.4 Solid Hardwood and Wood Veneer2.1.5 Plastic
3、 Laminate2.1.6 Plastic2.1.7 Cast Iron2.1.8 Steel2.1.9 Recycle Efforts2.2 SEATING SYSTEM2.2.1 Backs2.2.1.1 Plastic Rear Panels2.2.1.2 Plastic Laminate FinishWood Rear Panels2.2.1.3 Upholstered Inner Panels2.2.1.4 Exposed Plywood Front and (2) Row and seat number identification.Design must comply with
4、 all applicable fire and electrical codes, to include NFPA Life Safety Codes.Coordinate aisle lighting, communication and electrical requirements with Electrical Engineer. Add requirements as appropriate for the project.*SECTION 12 65 00 Page 3Provided by IHSNot for ResaleNo reproduction or networki
5、ng permitted without license from IHS-,-,-1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and tit
6、le.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will autom
7、atically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation
8、 only.ASTM INTERNATIONAL (ASTM)ASTM A 1011/A 1011M (2007) Standard Specification for Steel, Sheet, and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength Low-Alloy with Improved FormabilityASTM A 48/A 48M (2003) Standard Specification for Gray Iron CastingsASTM A 513 (2
9、007) Standard Specification for Electric-Resistance-Welded Carbon and Alloy Steel Mechanical TubingASTM D 4157 (2007) Standard Test Method for Abrasion Resistance of Textile Fabrics (Oscillatory Cylinder Method)ASTM F 851 (2005) Standard Test Method for Self-Rising Seat MechanismsHARDWOOD PLYWOOD AN
10、D VENEER ASSOCIATION (HPVA)HPVA HP-1 (2004) American National Standard for Hardwood and Decorative PlywoodNATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)NEMA LD 3 (2005) Standard for High-Pressure Decorative LaminatesSECTION 12 65 00 Page 4Provided by IHSNot for ResaleNo reproduction or network
11、ing permitted without license from IHS-,-,-U.S. GREEN BUILDING COUNCIL (USGBC)LEED (2002; R 2005) Leadership in Energy and Environmental Design(tm) Green Building Rating System for New Construction (LEED-NC)1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMIT
12、TAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already m
13、arked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army p
14、rojects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or ot
15、her organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bra
16、cketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval.information only. When used, a designation following the “G“ designation identifies the office that will review th
17、e submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsDetailed Drawings; G; G, _Seating plans dimensioned and showing row spacing, row lengths, the varying lateral spacing at backs and seats, back pitch, and seat widths for t
18、he various section lengths, placement of standards, floor pitch, and riser height, where applicable. SECTION 12 65 00 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Drawings indicating metal thickness, fastenings, details of hinge mechanism, s
19、eat and back dimensions, and proposed finish.SD-03 Product DataSeating System; G; G, _Installation; G; G, _Manufacturers descriptive data, catalog cuts, and installation instructions.Local/Regional MaterialsDocumentation indicating distance between manufacturing facility and the project site. Indica
20、te distance of raw material origin from the project site. Indicate relative dollar value of local/regional materials to total dollar value of products included in project.SD-04 Samples*NOTE: Determine on project by project basis if sample chair is required.*Seating System; G; G, _Minimum 150 by 150m
21、m 6 by 6 inches samples of upholstery, exposed plywood, plastic laminate, wood, identification plate, paint, armrest and plastic finish materials. Furnish fabric samples of sufficient size to show color range, pattern, and finish.One complete chair that meets requirements specified. Chair sample may
22、 be incorporated into the installation, provided the sample is approved and its location is noted.SD-06 Test ReportsFire Safety; G; G, _Tests; G; G, _Complete set of test reports for the fire safety and other testing.SD-07 CertificatesSeating SystemTwo complete sets of certificates attesting that th
23、e proposed seating system meets specified requirements. Date the certificate after the award of contract, include name the project and a list of specific requirements being certified.Recyclable Materials; G; G, _Recycle EffortsReport stating that the seating system contains recycled SECTION 12 65 00
24、 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-materials and indicating the actual percentage of recycled material, to include percent of post consumer and post industrial, and relative dollar value of recycled content products to total dolla
25、r value of products included in project.SD-10 Operation and Maintenance DataAssembly Manuals; G; G, _Three sets of assembly manuals describing assembly procedures.Maintenance Manuals; G; G, _Three sets of maintenance manuals describing routine maintenance and inspection, proper cleaning and minor re
26、pair procedures.SD-11 Closeout SubmittalsSeating SystemLEED documentation relative to recycled content credit in accordance with LEED Reference Guide. Include in LEED Documentation Notebook.AdhesivesFresh PaintLEED documentation relative to low-emitting materials credit in accordance with LEED Refer
27、ence Guide. Include in LEED Documentation Notebook.1.3 QUALITY ASSURANCE1.3.1 WarrantyWarrant the fixed seating for a period of 5 years with the following exceptions: one year for fabric and two years for tablet arms. Provide manufacturers standard performance guarantees or warranties that extend be
28、yond the periods listed.1.3.2 Certified Installers and Licensed ElectriciansWhen recommended by the manufacturer, seating shall be delivered and installed by an authorized dealer with a certified installation crew. All hardwiring shall be completed by a licensed electrician provided by the Contracto
29、r; the certified installers shall be onsite when questions arise.1.4 DELIVERY, STORAGE, AND HANDLING*NOTE: Seating components can adsorb VOCs emitted from other sources and be a home for a variety of bacteria, microbes, dust mites, etc. Materials with high short-term emissions include, but are not l
30、imited to: adhesives, sealants and glazing compounds (specifically those with petrochemical vehicles or carriers); paint, wood preservatives, and finishes; control and/or expansion joint fillers; hard finishes requiring adhesive SECTION 12 65 00 Page 7Provided by IHSNot for ResaleNo reproduction or
31、networking permitted without license from IHS-,-,-installation; gypsum board (with associated finish processes and products); and composite or engineered wood products with formaldehyde binders.*Deliver components to the site in unopened containers clearly labeled with the manufacturers name and con
32、tainer contents. Store materials in a safe, dry, and clean, well ventilated area (100 percent outside air supply, minimum of 1.5 air changes per hour, and no recirculation), protected from damage, soiling, and moisture, and strong contaminant sources and residues, maintained at a temperature above 1
33、6 degrees C 60 degrees F for 2 days prior to installation. Seating shall not be stored with materials which have high emissions of volatile organic compounds (VOCs) or other contaminants, including _. Do not store seating near materials that may offgas or emit harmful fumes, such as kerosene heaters
34、, fresh paint, or adhesives. Handle the items in a manner that will protect the materials from damage.PART 2 PRODUCTS*NOTE: Consider manufacturers whose products contribute to LEED. LEED-NC is addressed in this specification. If project consists of renovating existing space LEED-CI may also apply; m
35、odify spec as appropriate.*2.1 MATERIALSRecyclable materials (seat padding, plastics, etc.) shall conform to EPA requirements in accordance with Section 01 62 35 RECYCLED / RECOVERED MATERIALS. Favor the use of local/regional materials to comply with LEED requirements.2.1.1 Upholstery Fabric*NOTE: C
36、onsider the following when selecting upholstery fabric:- frequency of use- length of use- double rub testing - pilling- are food and drink to be allowedAdd information on recycled material or natural fibers as applicable for the project.*Provide fabric which is a plaindecorative_ weave, fiber conten
37、t of 100 percent polypropylene 100 percent polyester100 percent nylon_ treated to resist staining and soiling. Fabric upholstery for seating shall comply with a minimum of 55,00075,000_ double rubs when submitted to the tests required by ASTM D 4157.2.1.2 Polyurethane FoamPolyurethane foam shall be
38、fire retardant, nonhardening and non-oxidizing SECTION 12 65 00 Page 8Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-and shall have a high resistance to alkalies, oils, grease, soaps, abrasions, moisture, mildew, and tearing. Handling of this foam s
39、hall conform to the requirements of fire safety as specified in the Submittals paragraph.2.1.3 PlywoodProvide plywood conforming to HPVA HP-1, made of hardwood and of crossbanded construction. Face veneers, for exposed surfaces, shall be of Grade A hardwood, vertical grain, mapleoakcherry_ with manu
40、facturers standard finish. Unexposed veneers shall be sound grade hardwood or Grade A fir.2.1.4 Solid Hardwood and Wood VeneerSolid hardwood and wood veneer shall be first grade mapleoakcherry_. Finish exposed wood with manufacturers standard finish.2.1.5 Plastic LaminatePlastic laminate shall confo
41、rm to NEMA LD 3, Horizontal General Purpose Standard (HGS) Grade, 1.22 mm (plus or minus 0.127 mm) 0.048 inches (plus or minus 0.005 inches) in thickness.2.1.6 PlasticPlastic shall have built-in inhibitors to retard fading and anti-static compounds to retard dirt attraction. Pigment quality shall el
42、iminate need to paint plastic parts. Component surfaces shall have a textured finish. Color shall be integral to the plastic.2.1.7 Cast Iron Cast iron shall comply with ASTM A 48/A 48M. Finish shall be powder coat_.2.1.8 SteelSteel shall comply with ASTM A 513 or ASTM A 1011/A 1011M. Finish shall be
43、 powder coat_.2.1.9 Recycle EffortsUse materials with recycled content consisting of: _percent steel, _ percent plastic, _percent plastic laminate, _percent fabric and _percent wood.2.2 SEATING SYSTEMConstruct components and assembly free from objectionable projections or irregularities. Make corner
44、s and edges smooth and rounded. Unless otherwise noted, bolts, nuts, and other fastenings shall be concealed where possible. Steel shall be well-formed to shape and size required. Jointing of members shall be welded, riveted, or interlocked. Casting shall be fine textured, sound, and free of pits, blow holes, and fins. Lines shall be true, accurate, and true-to-pattern with excess metal or imperfections removed. Submit Assembly Manuals as specified in the Submittals paragraph.SECTION 12 65 00 Page 9Provided