AS NZS 61558 2 5-2003 Safety of power transformers power supply units and similar devices - Particular requirements for shaver transformers (IEC 61558-2-5 1997 MOD)《电力变压器、电源装置和类似装置.pdf

上传人:ownview251 文档编号:450175 上传时间:2018-11-18 格式:PDF 页数:19 大小:446.76KB
下载 相关 举报
AS NZS 61558 2 5-2003 Safety of power transformers power supply units and similar devices - Particular requirements for shaver transformers (IEC 61558-2-5 1997 MOD)《电力变压器、电源装置和类似装置.pdf_第1页
第1页 / 共19页
AS NZS 61558 2 5-2003 Safety of power transformers power supply units and similar devices - Particular requirements for shaver transformers (IEC 61558-2-5 1997 MOD)《电力变压器、电源装置和类似装置.pdf_第2页
第2页 / 共19页
AS NZS 61558 2 5-2003 Safety of power transformers power supply units and similar devices - Particular requirements for shaver transformers (IEC 61558-2-5 1997 MOD)《电力变压器、电源装置和类似装置.pdf_第3页
第3页 / 共19页
AS NZS 61558 2 5-2003 Safety of power transformers power supply units and similar devices - Particular requirements for shaver transformers (IEC 61558-2-5 1997 MOD)《电力变压器、电源装置和类似装置.pdf_第4页
第4页 / 共19页
AS NZS 61558 2 5-2003 Safety of power transformers power supply units and similar devices - Particular requirements for shaver transformers (IEC 61558-2-5 1997 MOD)《电力变压器、电源装置和类似装置.pdf_第5页
第5页 / 共19页
亲,该文档总共19页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、 AS/NZS 61558.2.5:2003 (IEC 61558-2-5:1997, MOD) Australian/New Zealand Standard Safety of power transformers, power supply units and similar - Part 2.5: Particular requirements for shaver transformers (IEC 61558-2-5:1997, MOD) Accessed by ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 17 May

2、2007This standard was issued in draft form for comment as DR 01943 AS/NZS 61558.2.5:2003 This Joint Australian/New Zealand Standard was prepared by Joint Technical Committee EL/2 - Safety of household and similar electrical appliances and small power transformers. It was approved on behalf of the Co

3、uncil of Standards Australia on 30 December 2002 and by the Council of Standards New Zealand on 20 December 2002. It was published on 24 January 2003. The following interests are represented on Committee EL/2 Association of Certification Bodies Australian Chamber of Commerce and Industry Australian

4、Electrical and Electronic Manufacturers Association Canterbury Manufacturers Association New Zealand Consumer Electronic Suppliers Association, Australia Electrical regulatory authorities, Australia Electrical test laboratories Electrical consultants Electricity Supply Association of Australia Insti

5、tution of Engineers Australia Metal Trades Industries Association of Australia Ministry of Consumer Affairs, New Zealand Keeping Standards up-to-date Standards are living documents, which reflect progress in science, technology and systems. To maintain their currency, all Standards are periodically

6、reviewed, and new editions are published. Between editions, amendments may be issued. Standards may also be withdrawn. It is important that readers assure themselves they are using a current Standard, which should include any amendments which may have been published since the Standard was purchased.

7、 Detailed information about joint Australian/New Zealand Standards can be found by visiting the Standards Australia web site at .au or Standards New Zealand web site at www.standards.co.nz and looking up the relevant Standard in the on-line catalogue. Alternatively, both organizations publish an ann

8、ual printed Catalogue with full details of all current Standards. For more frequent listings or notification of revisions, amendments and withdrawals, Standards Australia and Standards New Zealand offer a number of update options. For information about these services, users should contact their resp

9、ective national Standards organization. We also welcome suggestions for improvement in our Standards, and especially encourage readers to notify us immediately of any apparent inaccuracies or ambiguities. Please address your comment to the Chief Executive of either Standards Australia International

10、or Standards New Zealand at the address shown on the back cover. Accessed by ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 17 May 2007AS/NZS 61558.2.5:2003 (IEC 61558-2-5:1997, MOD) Australian/New Zealand Standard Safety of power transformers, power supply units and similar - Part 2.5: Partic

11、ular requirements for shaver transformers (IEC 61558-2-5:1997, MOD) Originated, in part, in Australia as AS C126-1939 Second edition C126 1958 Revised and redesignated AS 3126 1981 (withdrawn 1989) Originated, in part, in Australia as AS C167-1962 Revised and redesignated AS 3167 1981 (withdrawn 198

12、7) AS 3126 1981 and AS 3167 1981 were revised and redesignated AS 3108.1-1984, AS 3108.2-1984 and AS 3108.3 1984 Revised, amalgamated and redesignated AS 3108 1990 First published in New Zealand as NZS/AS 3108:1990 Jointly revised and redesignated AS/NZS 3108:1994 Jointly revised and redesignated, i

13、n part, as AS/NZS 61558.2.5:2003 COPYRIGHT Standards Australia/ Standards New Zealand All rights are reserved. No part of this work may be reproduced or copied in any form or by any means, electronic or mechanical, including photocopying, without the written permission of the publisher Published joi

14、ntly by Standards Australia International Ltd GPO Box 5420,Sydney, NSW 2001 Australia, and Standards New Zealand Private Bag 2439,Wellington 6020, New Zealand Accessed by ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 17 May 2007CONTENTS Page FOREWORD.3 1 Scope 5 2 Normative references .5 3 De

15、finitions6 4 General requirements .6 5 General notes on tests6 6 Ratings 6 7 Classification7 8 Marking and other information.7 9 Protection against accessibility to hazardous live parts8 10 Change of input voltage setting.8 11 Output voltage and output current under load8 12 No-load output voltage8

16、13 Short circuit voltage9 14 Heating 9 15 Short-circuit and overload protection.9 16 Mechanical strength .9 17 Protection against harmful ingress of dust, solid objects and moisture .10 18 Insulation resistance and dielectric strength 10 19 Construction.11 20 Components.12 21 Internal wiring.13 22 S

17、upply connection and other external flexible cables or cords13 23 Terminals for external conductors .13 24 Provision for protective earthing13 25 Screws and connections .13 26 Creepage distances, clearances and distances through insulation .13 27 Resistance to heat, abnormal heat, fire and tracking

18、.13 28 Resistance to rusting 13 Annexes .14 Annex C Material group II .14 Annex D Material group I 14 Annex S (informative) .14 Bibliography .14 Annex ZZ (informative) Variations to IEC 61558-2-5:1997 for application in Australia and New Zealand .15 Accessed by ISONET - CHINA STATE BUREAU OF TECHNIC

19、AL SUPERVIS on 17 May 20073 COPYRIGHT FOREWORD This standard was prepared by the Joint Standards Australia/Standards New Zealand Committee EL-002- Safety of Household and Similar Electrical Appliances and Small Power Transformers, to supersede, in part, AS/NZS 3108, Chapter 2, two years from publica

20、tion. The objective of this Standard is to provide manufacturers, designers, regulatory authorities, testing laboratories and similar organizations with safety requirements for the design, manufacture and testing of shaver transformers which can form the basis for approval by regulatory authorities

21、This Standard forms the first edition of AS/NZS 61558.2.5 Safety of power transformers, power supply units and similar - Part 2.5: Particular requirements for shaver transformers. This Standard is an adoption with national modifications and contains the full text of the first edition of IEC 61558-2-

22、5:1997, Safety of power transformers, power supply units and similar - Part 2-5: Particular requirements for shaver transformers and shaver supply units and has been varied as indicated to take account of Australian and New Zealand conditions. It is to be used in conjunction with the latest edition

23、of AS/NZS 61558.1 and its amendments. It was established on the basis of the first edition (2001) of that standard. This part 2 supplements or modifies the corresponding clauses of AS/NZS 61558.1 so as to convert it into the Australian/New Zealand Standard: Safety requirements for shaver transformer

24、s. Where a particular subclause of part 1 is not mentioned in this part 2, that subclause applies as far as is reasonable. Where this Standard states “addition“, “modification“ or “replacement“, the relevant text in part 1 is to be adapted accordingly. NOTE 1 Subclauses, notes, tables and figures wh

25、ich are additional to those in part 1 are numbered starting from 101. Annexes, which are additional to those in part 1 are lettered AA, BB, etc. Annex ZZ is for information only. NOTE 2 In this Standard the following print types are used: requirements: in arial type; test specifications: in italic t

26、ype; notes: in small arial type; Words in bold in the text are defined in clause 3. The numbering of clauses, subclauses, notes, tables, figures and annexes follows that of IEC 61558-2-5:1997. To allow for the introduction of additional material by the IEC, the numbers 101 to 200 have been reserved.

27、 To allow for additional material to be introduced by Australia and New Zealand, the numbers 201 to 300 are used to number further clauses, subclauses, notes, tables and figures in part 1. The numbers 301 to 400 are used to number further clauses, subclauses, notes, tables and figures in this part 2

28、. Additional annexes are lettered ZA, ZB and so on. This scheme has been introduced to reduce the likelihood of the IEC and Australia and New Zealand using the same identifier for different purposes. The use of the word VOID indicates that the IEC text is not used in Australia or New Zealand. The us

29、e of this word also avoids the need to renumber, clauses, notes, tables and figure if an earlier clause, note, table or figure is not used. As this Standard is reproduced from an International Standard, the following applies: Accessed by ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 17 May 20

30、074 COPYRIGHT (a) Its number does not appear on each page of text and its identity is shown on the cover and title page only. (b) In the source text “this International Standard“ should read “this Australian/New Zealand Standard“. (c) A full point substitutes for a comma when referring to a decimal

31、marker. Variations to IEC 61558-2-5:1997 are indicated at the appropriate places throughout this standard. Strikethrough (example) identifies IEC tables, figures and passages of text which, for the purposes of this Australian/New Zealand standard are deleted. Where Australian/New Zealand tables, fig

32、ures or passages of text are added, each is set in its proper place and identified by shading (example). Added figures are not themselves shaded, but are identified by a shaded border. Variations made to IEC 61558-2-5:1997 form the Australian variations for the purposes of the IECEE scheme for recog

33、nition of testing to standards for safety of electrical equipment (the CB scheme). These variations have been incorporated in the body of the standard. They are listed in Annex ZZ for easy reference. Accessed by ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 17 May 20075 COPYRIGHT AUSTRALIA/NE

34、W ZEALAND STANDARD SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR Part 2.5: Particular requirements for shaver transformers 1 Scope Replacement: This part 2-5 of IEC 61558 applies to shaver supply units, embodying one or more socket-outlets and a single phase air cooled isolating trans

35、former, having a rated supply voltage not exceeding 250 V a.c., a rated output not less than 20 VA and not exceeding 50 VA, a rated output voltage not exceeding 250 V, and a rated frequency not exceeding 500 Hz. This standard is also applicable to shaver transformers for embodiment into shaver suppl

36、y units. NOTE 1 Shaver supply units may be flush or surface mounted or incorporated in luminaires and other equipment. NOTE 2 Shaver supply units may be used to supply shavers, tooth brushes and similar small power devices. This part 2-5 of IEC 61558 applies to shaver transformers for embodiment int

37、o shaver supply units. These transformers are single phase air cooled isolating transformers, having a rated supply voltage not exceeding 250 V a.c., a rated output not less than 20 VA and not exceeding 50 VA, a rated output voltage not exceeding 250 V, and a rated frequency not exceeding 500 Hz. NO

38、TE 301 Requirements for shaver supply units are contained in AS/NZS 3194. 2 Normative references This clause of Part 1 is applicable. This clause of part 1 is applicable except as follows: Addition: IEC standard Year Title AU/NZ standard Year IEC 60068-2-62 1991 Environmental testing Part 2: Test me

39、thods Test Ef: Impact, pendulum hammer Accessed by ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 17 May 20076 COPYRIGHT IEC 60670 1989 General requirements for enclosures for accessories for household and similar fixed electrical installations 3 Definitions This clause of part 1 is applicable

40、 except as follows: Addition: 3.1.101 shaver transformer An isolating transformer for fixed installation and with limited output, designed to supply only one shaver, or the like, at a time. 3.1.102 shaver supply unit An accessory embodying a shaver transformer and one or more socket outlets allowing

41、 the use of only one plug at a time. 4 General requirements This clause of part 1 is applicable. 5 General notes on tests This clause of part 1 is applicable. 6 Ratings This clause of part 1 is applicable except as follows: Addition: 6.101 The rated output voltage shall not exceed 250 V a.c. Preferr

42、ed values are in the range 220 V to 240 V and additionally 110 V to 130 V. 6.102 The rated output shall be not less than 20 VA and shall not exceed 50 VA. 6.103 The rated supply voltage shall not exceed 250 V a.c. Compliance with the requirements of 6.101 to 6.103 is checked by inspection of the mar

43、king. Accessed by ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 17 May 20077 COPYRIGHT 6.104 The rated frequency shall not exceed 500 Hz. 7 Classification This clause of part 1 is applicable except as follows: 7.2 Modification: According to short-circuit protection or protection against abnor

44、mal use: inherently short-circuit proof transformer; non-inherently short-circuit proof transformer. 8 Marking and other information This clause of part 1 is applicable except as follows: 8.1 Modification: n) indication of the protection index IP, if higher than IP00: for shaver transformers; indica

45、tion of the protection index IP, if higher than IP21: for shaver supply units. 8.1 Addition: Shaver supply units and shaver transformers shall be marked with the symbol according to 8.11 of this standard replacing the symbol for isolating transformers. Shaver transformers shall be marked with the sy

46、mbol according to 8.11 of this standard instead of the symbol for isolating transformers. 8.2 This subclause does not apply. 8.7 Addition: For shaver supply units provided with a single-pole switch, the switched pole shall be connected to the line. 8.11 Addition: The following symbol shall be used:

47、for shaver supply units and shaver transformers (60417-IEC-5225) Accessed by ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 17 May 20078 COPYRIGHT for shaver transformers (60417-IEC-5225) 8.13 Addition: For shaver supply units, the marking for rated output voltage(s) and the symbol for shaver

48、supply units and shaver transformers shall be indicated on the front of the enclosure so as to be visible when the unit is mounted as in normal use. For shaver supply units intended to provide different output voltages, the selected output voltage setting shall be clearly discernible. For shaver tra

49、nsformers the symbol for shaver supply units and shaver transformers shall be provided only if the transformer is supplied separately. For shaver transformers the symbol for shaver transformers shall be provided only if the transformer is supplied separately. 9 Protection against accessibility to hazardous live parts This clause of part 1 is applicable. 10 Change of input voltage setting This clause of part 1 is applicable. 11 Output voltage and output current under load This clause of part 1 is applicable. 12 No-load output voltage This

展开阅读全文
相关资源
  • AS NZS 60695 11 20-2001 Fire hazard testing - Test flames - 500 W flame test methods《火灾试验 试验火焰 500W火焰试验法》.pdfAS NZS 60695 11 20-2001 Fire hazard testing - Test flames - 500 W flame test methods《火灾试验 试验火焰 500W火焰试验法》.pdf
  • AS NZS 60695 11 10-2001 Fire hazard testing - Test flames - 50 W horizontal and vertical flame test methods《火灾试验 试验火焰 50W水平和垂直火焰试验法》.pdfAS NZS 60695 11 10-2001 Fire hazard testing - Test flames - 50 W horizontal and vertical flame test methods《火灾试验 试验火焰 50W水平和垂直火焰试验法》.pdf
  • AS NZS 60335 2 9-2002 Household and similar electrical appliances - Safety - Particular requirements for grills toasters and similar portable cooking appliances.pdfAS NZS 60335 2 9-2002 Household and similar electrical appliances - Safety - Particular requirements for grills toasters and similar portable cooking appliances.pdf
  • AS NZS 60335 2 89-2002 Household and similar electrical appliances - Safety - Particular requirements for commercial refrigerating appliances with an incorporat.pdfAS NZS 60335 2 89-2002 Household and similar electrical appliances - Safety - Particular requirements for commercial refrigerating appliances with an incorporat.pdf
  • AS NZS 60335 2 15-2002 Household and similar electrical appliances - Safety - Particular requirements for appliances for heating liquids《家用及类似用途电气设备 安全性 特殊要求 液体.pdfAS NZS 60335 2 15-2002 Household and similar electrical appliances - Safety - Particular requirements for appliances for heating liquids《家用及类似用途电气设备 安全性 特殊要求 液体.pdf
  • AS NZS 4681-2000 The storage and handling of Class 9 (miscellaneous) dangerous goods and articles《第九类其他危险物品的储存和搬运》.pdfAS NZS 4681-2000 The storage and handling of Class 9 (miscellaneous) dangerous goods and articles《第九类其他危险物品的储存和搬运》.pdf
  • AS NZS 4671-2001 Steel reinforcing materials《钢加固材料》.pdfAS NZS 4671-2001 Steel reinforcing materials《钢加固材料》.pdf
  • AS NZS 4456 9-2003 Masonry units and segmental pavers and flags - Methods of test - Determining abrasion resistance《给水用1 2 In (12 mm)到2 In (50 mm)聚乙烯-铝-聚乙烯和交联聚乙.pdfAS NZS 4456 9-2003 Masonry units and segmental pavers and flags - Methods of test - Determining abrasion resistance《给水用1 2 In (12 mm)到2 In (50 mm)聚乙烯-铝-聚乙烯和交联聚乙.pdf
  • AS NZS 4456 8-2003 Masonry units and segmental pavers and flags - Methods of test - Determining moisture content dry density and ambient density《给水用1 2 In (12 m.pdfAS NZS 4456 8-2003 Masonry units and segmental pavers and flags - Methods of test - Determining moisture content dry density and ambient density《给水用1 2 In (12 m.pdf
  • AS NZS 4456 7-2003 Masonry units and segmental pavers and flags - Methods of test - Determining core percentage and material thickness《给水用1 2 In (12 mm)到2 In (5.pdfAS NZS 4456 7-2003 Masonry units and segmental pavers and flags - Methods of test - Determining core percentage and material thickness《给水用1 2 In (12 mm)到2 In (5.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > AS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1