ASTM C169-2016 Standard Test Methods for Chemical Analysis of Soda-Lime and Borosilicate Glass《碱石灰和硼硅酸盐玻璃的化学分析的标准试验方法》.pdf

上传人:sumcourage256 文档编号:465534 上传时间:2018-11-27 格式:PDF 页数:24 大小:286.45KB
下载 相关 举报
ASTM C169-2016 Standard Test Methods for Chemical Analysis of Soda-Lime and Borosilicate Glass《碱石灰和硼硅酸盐玻璃的化学分析的标准试验方法》.pdf_第1页
第1页 / 共24页
ASTM C169-2016 Standard Test Methods for Chemical Analysis of Soda-Lime and Borosilicate Glass《碱石灰和硼硅酸盐玻璃的化学分析的标准试验方法》.pdf_第2页
第2页 / 共24页
ASTM C169-2016 Standard Test Methods for Chemical Analysis of Soda-Lime and Borosilicate Glass《碱石灰和硼硅酸盐玻璃的化学分析的标准试验方法》.pdf_第3页
第3页 / 共24页
ASTM C169-2016 Standard Test Methods for Chemical Analysis of Soda-Lime and Borosilicate Glass《碱石灰和硼硅酸盐玻璃的化学分析的标准试验方法》.pdf_第4页
第4页 / 共24页
ASTM C169-2016 Standard Test Methods for Chemical Analysis of Soda-Lime and Borosilicate Glass《碱石灰和硼硅酸盐玻璃的化学分析的标准试验方法》.pdf_第5页
第5页 / 共24页
亲,该文档总共24页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: C169 16Standard Test Methods forChemical Analysis of Soda-Lime and Borosilicate Glass1This standard is issued under the fixed designation C169; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.

2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 These test methods cover the quantitative chem

3、icalanalysis of soda-lime and borosilicate glass compositions forboth referee and routine analysis. This would be for the usualconstituents present in glasses of the following types: (1)soda-lime silicate glass, (2) soda-lime fluoride opal glass, and(3) borosilicate glass. The following common oxide

4、s, whenpresent in concentrations greater than indicated, are known tointerfere with some of the determinations in this method: 2 %barium oxide (BaO), 0.2 % phosphorous pentoxide (P2O5),0.05 % zinc oxide (ZnO), 0.05 % antimony oxide (Sb2O3),0.05 % lead oxide (PbO).1.2 The analytical procedures, divid

5、ed into two generalgroups, those for referee analysis, and those for routineanalysis, appear in the following order:SectionsProcedures for Referee Analysis:Silica 10BaO, R2O2(Al2O3+P2O5), CaO, and MgO 1115Fe2O3,TiO2,ZrO2by Photometry and Al2O3by Com-plexiometric Titration1622Cr2O3by Volumetric and P

6、hotometric Methods 2325MnO by the Periodate Oxidation Method 2629Na2O by the Zinc Uranyl Acetate Method and K2Obythe Tetraphenylborate Method3033SO3(Total Sulfur) 34 35As2O3by Volumetric Method 3640Procedures for Routine Analysis:Silica by the Single Dehydration Method 4244Al2O3, CaO, and MgO by Com

7、plexiometric Titration,and BaO, Na2O, and K2O by Gravimetric Method4551BaO, Al2O3, CaO, and MgO by Atomic Absorption; andNa2O and K2O by Flame Emission Spectroscopy5259SO3(Total Sulfur) 60B2O361 62Fluorine by Pyrohydrolysis Separation and Specific IonElectrode Measurement6366P2O5by the Molybdo-Vanad

8、ate Method 6770Colorimetric Determination of Ferrous Iron Using 1,10Phenanthroline71761.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices a

9、nd determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C146 Test Methods for Chemical Analysis of Glass SandC225 Test Methods for Resistance of Glass Containers toChemical AttackD1193 Specification for Reagent WaterE50 Practices for Apparatu

10、s, Reagents, and Safety Consid-erations for Chemical Analysis of Metals, Ores, andRelated MaterialsE60 Practice for Analysis of Metals, Ores, and RelatedMaterials by Spectrophotometry3. Significance and Use3.1 These test methods can be used to ensure that thechemical composition of the glass meets t

11、he compositionalspecification required for the finished glass product.3.2 These test methods do not preclude the use of othermethods that yield results within permissible variations. In anycase, the analyst should verify the procedure and techniqueemployed by means of a National Institute of Standar

12、ds andTechnology (NIST) standard reference material having a com-ponent comparable with that of the material under test.Alist ofstandard reference materials is given in the NIST SpecialPublication 260,3current edition.3.3 Typical examples of products manufactured using soda-lime silicate glass are c

13、ontainers, tableware, and flat glass.3.4 Typical examples of products manufactured using boro-silicate glass are bakeware, labware, and fiberglass.1These test methods are under the jurisdiction of ASTM Committee C14 onGlass and Glass Products and are the direct responsibility of Subcommittee C14.02o

14、n Chemical Properties and Analysis.Current edition approved April 1, 2016. Published May 2016. Originallyapproved in 1941. Last previous edition approved in 2011 as C169 92 (2011).DOI: 10.1520/C0169-16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Serv

15、ice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from National Institute of Standards and Technology, Gaithersburg,MD 20899.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Co

16、nshohocken, PA 19428-2959. United States13.5 Typical examples of products manufactured using fluo-ride opal glass are containers, tableware, and decorativeglassware.4. Purity of Reagents4.1 Reagent grade chemicals shall be used throughout.Unless otherwise indicated, it is intended that reagents shal

17、lconform to the specifications of the Committee on AnalyticalReagents of the American Chemical Society, where suchspecifications are available.4Other grades may be used, pro-vided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy

18、ofthe determination.4.2 Purity of WaterUnless otherwise indicated, referenceto water shall be understood to mean reagent water as definedby Type I, II, or III of Specification D1193.5. Concentration of Acids and Ammonium Hydroxide5.1 When acids and ammonium hydroxide are specified byname or chemical

19、 formula only, concentrated reagents of thefollowing percent concentrations are intended:%Hydrochloric acid (HCl) 36 to 38Hydrofluoric acid (HF) 48 to 51Nitric acid (HNO3) 69to71Perchloric acid (HClO4) 70to72Sulfuric acid (H2SO4) 95to98Ammonium hydroxide (NH4OH) 28 to 305.2 Concentrations of diluted

20、 acids and NH4OH exceptwhen standardized are specified as a ratio, stating the numberof volumes of the concentrated reagent to be added to a givennumber of volumes of water, as follows: HCl (1 + 99) means1 volume of concentrated HCl (approximately 37 %) added to99 volumes of water.5.3 The hygroscopi

21、c nature of the ignited precipitates ofsilica, aluminum oxide, and calcium oxide obtained in themethods to be described, requires the use of fresh and highlyactive desiccants. For this purpose, magnesium perchlorate(Mg(ClO4)2) and barium oxide (BaO) are recommended.6. Filter Papers6.1 Throughout the

22、se test methods, filter papers will bedesignated as “coarse,” “medium,” or “fine,” without namingbrands or manufacturers.All filter papers are of the double acidwashed ashless type. “Coarse” filter paper refers to the porositycommonly used for the filtration of aluminum hydroxide.“Medium” filter pap

23、er refers to that used for filtration ofcalcium oxalate, and “fine” filter paper to that used for bariumsulfate.7. Photometers and Photometric Practice7.1 Photometers and photometric practice prescribed inthese methods shall conform to Practice E60.7.2 The considerations of instrumentation given in

24、TestMethods C146 are equally applicable to these test methods.8. Preparation of Sample8.1 Glass crushed in a steel mortar as described in TestMethods C225, and sieved through a 150-m (No. 100) meshsieve, is generally suitable for analysis, except for the deter-mination of iron oxide (Fe2O3). After c

25、rushing and sieving,place the powder on a sheet of paper and pass a small magnetthrough it to remove adventitious iron. Then store in a tightlyclosed container and keep in a desiccator.8.2 A sample prepared in an iron mortar is not recom-mended for the determination of Fe2O3. Instead, glass shouldbe

26、 ground in an agate mortar after ascertaining it is free ofcontamination.8.3 A sample prepared for the determination of fluorineshould be sieved through a 75-m (No. 200) mesh sieve ratherthan a 150-m (No. 100) sieve.8.4 The practice of drying samples in a drying oven at 105to 110C after preparation

27、is not recommended. Powderedglass can fix CO2and water as readily at this temperature as atroom temperature. A freshly prepared sample, if exposed but ashort time to the atmosphere, will not have acquired an ignitionloss of much analytical significance. If ignition loss isdetermined, use the followi

28、ng temperature schedules:Soda-lime glass 800C for 1 hFluorine opal glass 500 to 550C for 1 hBorosilicate glass 800C for 1 hDetermine the ignition loss ona1to3-gsample in aplatinum crucible.9. Precision and Bias9.1 The probable precision of results that can be expectedby the use of the procedures des

29、cribed in these test methods isshown in the following tabulation. Precision is given asabsolute error, and is dependent on the quantity of constituentpresent as well as the procedure used.Probable Precision of Results, weight %Constituent Referee Analysis Routine AnalysisSilica 0.1 0.25BaO 0.02 0.05

30、Al2O3+P2O50.05 0.10 (P2O5)CaO 0.05 0.15MgO 0.05 0.02 to 0.10Fe2O30.003 . . .TiO20.005 . . .ZrO20.001 to 0.005 . . .Cr2O3(volumetric) 0.005 . . .Cr2O3(photometric) 0.0001 to 0.001 . . .MnO 0.001 to 0.005 . . .Na2O 0.05 0.25 (flame emission)K2O 0.02 to 0.05 0.02 to 0.10 (flame emission)SO30.02 0.05As2

31、O30.005 . . .P2O5. . . 0.005 to 0.02B2O3. . . 0.05 to 0.15Fluorine . . . 0.01 to 0.20 (0.1 to 6.0 %)9.2 It is recommended that reported results be rounded asfollows:4Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing

32、of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.C169 162Percent Number of Significant FiguresRetaine

33、d After Rounding1to100 30.1to0.99 20.01 to 0.09 1 or 20.01 1 or 29.3 Recorded results should be carried to one more signifi-cant figure than required in 9.2.PROCEDURES FOR REFEREE ANALYSISSILICA10. Procedure10.1 Weigh 1.000 g of powdered sample and 1.5 g ofanhydrous sodium carbonate (Na2CO3) for sod

34、a-lime glass, or2.0gofNa2CO3for borosilicate glass, into a clean 75-mLplatinum dish (see 10.1.1); mix well with a platinum orNichrome5wire. Tap the charge so it lies evenly in the bottomof the dish. Cover with platinum lid and heat first at a dull redheat over a clean oxidizing flame; gradually rais

35、e the tempera-ture until a clear melt is obtained. Properly carried out, little orno spattering should occur and the fusion can be performed in3 to 4 min. When melted, rotate the melt to spread it evenlyover the bottom and lower sides of the dish, graduallywithdrawing from the flame. Cover and cool

36、to room tempera-ture. During fusion, the dish should be handled at all times withplatinum-tipped tongs and the fusion performed with a plati-num (preferably 90 % platinum and 10 % rhodium alloy) orsilica triangle.10.1.1 To obtain accurate repeat weighings, platinum wareshall be kept scrupulously cle

37、an on the outside of the vessel aswell as on the inside. It should be polished brightly with fine,round grain sand and protected from dirty surfaces. It isrecommended that porcelain plates be used for cooling fusions,and that platinum be set on paper towels or other clean materialduring filtration.1

38、0.2 Add 20 to 25 mL of HCl (1 + 1) (Note 1) under theplatinum cover and digest on a steam bath or hot plate until themelt has completely disintegrated; it is also possible to digestthe melt in the cold overnight. Police and rinse the lid with afine jet of water; rinse down the sides of the dish and

39、evaporateto dryness on a steam bath or under an infrared lamp. Keep thedish covered with a raised cover glass during evaporation.When evaporation is complete (Note 2) (absence of HCl), cool,drench the residue with 5 mL of HCl, and then add 20 mL ofhot water. Digest for 5 min and filter through a 9-c

40、m mediumfilter paper. Catch the filtrate in a 250-mL platinum dish.Transfer the precipitated silica to the filter with the aid of apoliceman and a bit of paper pulp, and wash the precipitate andpaper twelve times with hot 2 % HCl. Transfer the paper andprecipitate to the dish used for fusion and deh

41、ydration andreserve for subsequent ignition. Wipe the stirring rod and theperiphery of the funnel with a piece of damp filter paper andadd to the dish containing the precipitate for ignition.NOTE 1Glasses containing fluorine in small amounts (less than0.25 %) will not cause significant error. Glasse

42、s containing larger amountsof fluorine (for example, fluoride opals) are analyzed as above with thisexception: after the fusion has been made and before addition of the acid(see 10.2), add 10 mL of aluminum chloride (AlCl3) solution(10 mL = 200 mg of Al) to complex fluorine. If evaporation is made o

43、n asteam bath, it is difficult to dry the residue. It is suggested that final drying,before filtration, be made in a drying oven for 30 to 45 min at 105C.Results for SiO2when analyzing fluorine opals may tend to be low by0.2 to 0.3 %. For an alternative, but more lengthy procedure, consultApplied In

44、organic Analysis.6NOTE 2Boron in amounts less than 5 % B2O3does not interfere.However, if boron is greater than 5 %, proceed to the point of completingthe first dehydration (see 10.2), then add 20 mL of anhydrous methanolsaturated with dry HCl (gas), and evaporate to dryness on an air bath orunder a

45、n infrared lamp. Repeat once more before proceeding.10.3 Evaporate the filtrate to dryness on the steam bath orunder an infrared lamp. When dry, cool, drench with 10 mL ofHCl (1 + 1) and again evaporate just to dryness; then bake in adrying oven at 105C for 30 min. Cool, drench with 5 mL ofHCl, and

46、add 20 mL of hot water and a small bit of filter pulp.Digest hot for 5 min and filter through a 7-cm fine paper. Policethe dish with the aid of a bit of paper pulp and wash precipitateand paper eight times with hot 2 % HCl. Transfer the paper andprecipitate to the dish containing the initial precipi

47、tation. Wipethe stirring rod and the periphery of the funnel with a piece ofdamp filter paper and add to the dish containing the precipitatefor ignition.10.4 Partially cover the dish with its platinum lid but leaveenough space so air can circulate during ignition. Place the dishin a cold muffle furn

48、ace and bring the temperature to 1200Cfor 30 min. Carefully and completely cover the dish beforeremoving it from the furnace and transfer to a desiccator. Coolto room temperature and weigh the covered dish (W1). Moistenthe silica with 1 to 2 mL of water and add 4 to 5 mL of HF and0.5 g of oxalic aci

49、d crystals. Evaporate to dryness on a sandbath or under an infrared lamp. Carefully sublime any remain-ing oxalic acid, cover the dish with its platinum cover, heat to1000C for 2 min, cool, and weigh (W2) as before.10.5 CalculationCalculate the percent of SiO2as follows:SiO2,%5 W12 W2! 3100 (1)BaO, R2O3(Al2O3+P2O5), CaO, AND MgO11. General Considerations11.1 The detailed analysis described below may be desirableonly infrequently. Several steps may be omitted without undueloss of accuracy, for example, the hydrogen sulfide (H