ASTM C507-2010 Standard Specification for Reinforced Concrete Elliptical Culvert Storm Drain and Sewer Pipe《钢筋混凝土制椭圆形涵管、雨水管和污水管用标准规范》.pdf

上传人:roleaisle130 文档编号:466856 上传时间:2018-11-27 格式:PDF 页数:9 大小:165.82KB
下载 相关 举报
ASTM C507-2010 Standard Specification for Reinforced Concrete Elliptical Culvert Storm Drain and Sewer Pipe《钢筋混凝土制椭圆形涵管、雨水管和污水管用标准规范》.pdf_第1页
第1页 / 共9页
ASTM C507-2010 Standard Specification for Reinforced Concrete Elliptical Culvert Storm Drain and Sewer Pipe《钢筋混凝土制椭圆形涵管、雨水管和污水管用标准规范》.pdf_第2页
第2页 / 共9页
ASTM C507-2010 Standard Specification for Reinforced Concrete Elliptical Culvert Storm Drain and Sewer Pipe《钢筋混凝土制椭圆形涵管、雨水管和污水管用标准规范》.pdf_第3页
第3页 / 共9页
ASTM C507-2010 Standard Specification for Reinforced Concrete Elliptical Culvert Storm Drain and Sewer Pipe《钢筋混凝土制椭圆形涵管、雨水管和污水管用标准规范》.pdf_第4页
第4页 / 共9页
ASTM C507-2010 Standard Specification for Reinforced Concrete Elliptical Culvert Storm Drain and Sewer Pipe《钢筋混凝土制椭圆形涵管、雨水管和污水管用标准规范》.pdf_第5页
第5页 / 共9页
亲,该文档总共9页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: C507 10Standard Specification forReinforced Concrete Elliptical Culvert, Storm Drain, andSewer Pipe1This standard is issued under the fixed designation C507; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of

2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers reinforced

3、elliptically shapedconcrete pipe to be used for the conveyance of sewage,industrial wastes, and storm water, and for the construction ofculverts.1.2 Pipe designed for placement with the major axis hori-zontal shall be designated as “Horizontal Elliptical Pipe.” Pipedesigned for placement with the ma

4、jor axis vertical shall bedesignated as “Vertical Elliptical Pipe.”1.3 This specification is the inch-pound companion toSpecification C507M; therefore, no SI equivalents are pre-sented in the specification.NOTE 1This specification is a manufacturing and purchase specifica-tion only, and does not inc

5、lude requirements for bedding, backfill, or therelationship between field load condition and the strength classification ofpipe. However, experience has shown that the successful performance ofthis product depends upon the proper selection of the class of pipe, typeof bedding and backfill, and care

6、that the installation conforms to theconstruction specifications. The owner of the reinforced concrete pipespecified herein is cautioned that he must correlate the field requirementswith the class of pipe specified and provide inspection at the constructionsite.2. Referenced Documents2.1 ASTM Standa

7、rds:2A36/A36M Specification for Carbon Structural SteelA82/A82M Specification for Steel Wire, Plain, for ConcreteReinforcementA185/A185M Specification for Steel Welded Wire Rein-forcement, Plain, for ConcreteA496/A496M Specification for Steel Wire, Deformed, forConcrete ReinforcementA497/A497M Speci

8、fication for Steel Welded Wire Rein-forcement, Deformed, for ConcreteA615/A615M Specification for Deformed and PlainCarbon-Steel Bars for Concrete ReinforcementA706/A706M Specification for Low-Alloy Steel Deformedand Plain Bars for Concrete ReinforcementC33 Specification for Concrete AggregatesC150

9、Specification for Portland CementC260 Specification for Air-Entraining Admixtures for Con-creteC309 Specification for Liquid Membrane-Forming Com-pounds for Curing ConcreteC494/C494M Specification for Chemical Admixtures forConcreteC497M Test Methods for Concrete Pipe, Manhole Sections,or Tile Metri

10、cC595 Specification for Blended Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC822 Terminology Relating to Concrete Pipe and RelatedProductsC989 Specification for Slag Cement for Use in Concreteand MortarsC1017/C1017M Specification for Ch

11、emical Admixtures forUse in Producing Flowing ConcreteC1116 Specification for Fiber-Reinforced Concrete andShotcrete3. Terminology3.1 DefinitionsFor definitions of terms relating to con-crete pipe, see Terminology C822.4. Classification4.1 Pipe manufactured according to this specification shallbe of

12、 five classes each for horizontal elliptical and verticalelliptical pipe with identification as follows:1This specification is under the jurisdiction of ASTM Committee C13 onConcrete Pipe and is the direct responsibility of Subcommittee C13.02 onReinforced Sewer and Culvert Pipe.Current edition appr

13、oved Feb. 1, 2010. Published February 2010. Originallyapproved in 1963. Last previous edition approved in 2009 as C507 09. DOI:10.1520/C0507-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards v

14、olume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Horizontal Elliptical Pipe Vertical Elliptical PipeClass HE-A Class VE-IIClass HE-I Class VE-IIIClass

15、HE-II Class VE-IVClass HE-III Class VE-VClass HE-IV Class VE-VI4.2 The strength requirements for horizontal elliptical pipeare prescribed in Table 1 and for vertical elliptical pipe areprescribed in Table 2.5. Basis of Acceptance5.1 Unless otherwise designated by the owner at the time of,or before,

16、placing an order, there are two separate andalternative bases of acceptance. Independent of the method ofacceptance, the pipe shall be designed to meet both the 0.01-in.crack and ultimate strength requirements.5.1.1 Acceptance on Basis of Plant Load-Bearing Tests,Material Tests, and Inspection of Ma

17、nufactured Pipe for VisualDefects and ImperfectionsAcceptability of the pipe in alldiameters and classes produced in accordance with 7.1 or 7.2shall be determined by the results of the three-edge-bearingtests as defined in 11.3.1; by such material tests as are requiredin 6.2, 6.3, 6.5, and 6.6; by a

18、n absorption test of the concretefrom the wall of the pipe as required in 11.9; and by visualinspection of the finished pipe to determine its conformancewith the accepted design and its freedom from defects.5.1.2 Acceptance on the Basis of Material Tests and Inspec-tion of Manufactured Pipe for Defe

19、cts and ImperfectionsAcceptability of the pipe in all diameters and classes producedin accordance with 7.1 or 7.2 shall be determined by the resultsof such material tests as are required in 6.2, 6.3, 6.5, and 6.6;by crushing tests on concrete cores or cured concrete cylinders;TABLE 1 Design Requirem

20、ents for Horizontal Elliptical (HE) PipeANOTE 1The test load in pounds per linear foot equals D-load 3 inside span in feet.NOTE 2Single cage reinforcement, providing tension steel at the top, bottom, and springline, shall be permitted instead of double cage reinforcement.The area of such reinforceme

21、nt shall be 112 % of the tabulated inner cage area.NOTE 3An inner and outer cage plus quadrant mats shall be permitted instead of double cage reinforcement. The area of such reinforcement shallbe in accordance with Fig. 1.NOTE 4An inner and outer cage plus a middle cage shall be permitted instead of

22、 double cage reinforcement. The area of such reinforcement shallbe in accordance with Fig. 2.DesignatedDiameter,EquivalentRoundSize, in.DesignatedRise, in. 3Span, in.MinimumWallThickness,in.Reinforcement, in.2/linear ftClass HE-A Class HE-I Class HE-II Class HE-III Class HE-IVD-Loads0.01 = 600Ult =

23、9000.01 = 800Ult = 12000.01 = 1000Ult = 15000.01 = 1350Ult = 20000.01 = 2000Ult = 3000InCageOutCageInCageOutCageInCageOutCageInCageOutCageInCageOutCage1824273033363942485414 3 2319 3 3022 3 3424 3 3827 3 4229 3 4532 3 4934 3 5338 3 6043 3 68234314312334334412434551260.080.110.140.100.120.110.130.150

24、.170.20.0.100.120.110.130.150.170.200.110.150.180.130.170.150.170.200.230.27.0.130.170.150.170.200.230.270.140.190.230.170.210.190.210.240.280.34.0.170.210.190.210.240.280.340.190.260.310.230.280.260.290.330.390.45.0.230.280.260.290.330.390.450.270.390.460.340.410.390.440.50.0.340.410.390.440.5060 4

25、8 3 76 612 0.24 0.24 0.32 0.32 0.40 0.40 0.53 0.53 . . . . . .66 53 3 83 7 0.27 0.27 0.36 0.36 0.45 0.45 0.61 0.61 . . . . . .72 58 3 91 712 0.31 0.31 0.41 0.41 0.52 0.52 0.70 0.70 . . . . . .78 63 3 98 8 0.34 0.34 0.45 0.45 0.56 0.56 0.78 0.78 . . . . . .84 68 3 106 812 0.38 0.38 0.50 0.50 0.63 0.6

26、3 0.88 0.88 . . . . . .90 72 3 113 9 . . . . . . . . . .96 77 3 121 912 . . . . . . . . . .102 82 3 128 934 . . . . . . . . . .108 87 3 136 10 . . . . . . . . . .114 92 3 143 1012 . . . . . . . . . .120 97 3 151 11 . . . . . . . . . .132 106 3 166 12 . . . . . . . . . .144 116 3 180 13 . . . . . . .

27、 . . .Concrete strengthB, psi 4000 4000 4000 18 to 66 in.4000400072 to 84 in.5000AFor sizes and loads beyond those shown in this table, pipe designs are available that make use of one or a combination of the following: shear steel, multiple cages,or thicker walls in accordance with the provisions of

28、 7.3.BConcrete strength for designs with reinforcement tabulated. For modified or special designs, see 7.3.C507 102by an absorption test of the concrete from the wall of the pipefor each mix design that is used on an order; and by inspectionof the finished pipe, including amount and placement ofrein

29、forcement, to determine its conformance with the accepteddesign and its freedom from defects.5.1.3 When agreed upon by the owner and the manufacturer,any portion or any combination of the tests itemized in 5.1.1 or5.1.2 may form the basis of acceptance.5.2 Age for AcceptancePipe shall be considered

30、ready foracceptance when they conform to the requirements as indicatedby the specified tests.6. Materials6.1 The aggregate shall be so sized, graded, proportioned,and mixed with such proportions of portland cement, blendedhydraulic cement, or portland cement and supplementarycementing materials, or

31、admixtures, if used, or a combinationthereof, and water to produce a homogeneous concrete mixtureof such quality that the pipe will conform to the test and designrequirements of this specification. In no case, however, shallthe proportion of portland cement, blended hydraulic cement,or a combination

32、 of portland cement and supplementarycementing materials be less than 470 lb/yd3.6.2 Cementitious Materials:6.2.1 CementCement shall conform to the requirementsof Specification C150, or shall be portland blast-furnace slagcement, or slag modified portland cement, or portland-pozzolan cement conformi

33、ng to the requirements of Specifica-tion C595, except that the pozzolan constituent in the Type IPportland pozzolan cement shall be fly ash.6.2.2 Ground Granulated Blast-Furnace Slag (GGBFS)GGBFS shall conform to the requirements of Grade 100 or 120of Specification C989.6.2.3 Fly AshFly ash shall co

34、nform to the requirements ofClass F or Class C of Specification C618.6.2.4 Allowable Combinations of Cementitious MaterialsThe combination of cementitious materials used in the concreteshall be one of the following:6.2.4.1 Portland cement only,6.2.4.2 Portland blast furnace slag cement only,6.2.4.3

35、Slag modified portland cement only,6.2.4.4 Portland pozzolan cement only,6.2.4.5 A combination of portland cement and groundgranulated blast-furnace slag,6.2.4.6 A combination of portland cement and fly ash, or6.2.4.7 A combination of portland cement, ground granu-lated blast-furnace slag (not to ex

36、ceed 25 % of the totalcementitious weight) and fly ash (not to exceed 25 % of thetotal cementitious weight.6.3 AggregatesAggregates shall conform to SpecificationC33 except that the requirement for gradation shall not apply.TABLE 2 Design Requirements for Vertical Elliptical PipeANOTE 1Test load in

37、pounds per linear foot equals D-load 3 inside span in feet.NOTE 2An inner and outer cage plus quadrant mats shall be permitted instead of double cage reinforcement. The area of such reinforcement shallbe in accordance with Fig. 3.NOTE 3Single cage reinforcement, providing tension steel at the top, b

38、ottom, and springline, shall be permitted instead of double cage reinforcement.The area of such reinforcement shall be 112 % of the tabulated inner cage area.NOTE 4An inner and outer cage plus a middle cage shall be permitted instead of double cage reinforcement. The area of such reinforcement shall

39、be in accordance with Fig. 4.DesignatedDiameter,EquivalentRoundSize, in.DesignatedRise, in. 3Span, in.MinimumWallThickness,in.Reinforcement, in.2/linear ftClass VE-II Class VE-III Class VE-IV Class VE-V Class VE-VID-Loads0.01 = 1000Ult = 15000.01 = 1350Ult = 20000.01 = 2000Ult = 30000.01 = 3000Ult =

40、 37500.01 = 4000Ult = 5000InCageOutCageInCageOutCageInCageOutCageInCageOutCageInCageOutCage3639424854606672788445 3 2949 3 3253 3 3460 3 3868 3 4376 3 4883 3 5391 3 5898 3 63106 3 6841243455126612771288120.080.090.100.110.130.160.180.210.230.260.050.050.060.070.080.100.110.130.140.160.110.120.130.15

41、0.180.210.250.280.310.350.070.070.080.090.110.130.150.170.190.210.160.180.200.220.270.310.360.410.470.530.100.110.120.130.160.190.220.250.280.320.230.260.290.330.400.470.55.0.140.160.170.200.240.280.33.0.310.350.380.440.53.0.190.210.230.260.32.90 113 3 72 9 . . . . . . . . . .96 121 3 77 912 . . . .

42、 . . . . . .102 128 3 82 934 . . . . . . . . . .108 136 3 87 10 . . . . . . . . . .114 143 3 92 1012 . . . . . . . . . .120 151 3 97 11 . . . . . . . . . .132 166 3 106 12 . . . . . . . . . .144 180 3 116 13 . . . . . . . . . .Concrete strengthB, psi 4000 4000 4000 5000 6000AFor sizes and loads beyo

43、nd those shown in this table, pipe designs are available which make use of one or a combination of the following: shear steel, multiple cages,or thicker walls in accordance with the provisions of 7.3.BConcrete strength for designs with reinforcement tabulated. For modified or special designs, see 7.

44、3.C507 1036.4 Admixtures and BlendsThe following admixtures andblends are allowable:6.4.1 Air-entraining admixture conforming to SpecificationC260;6.4.2 Chemical admixture conforming to SpecificationC494/C494M;6.4.3 Chemical admixture for use in producing flowingconcrete conforming to Specification

45、C1017/C1017M; and6.4.4 Chemical admixture or blend approved by the owner.6.5 Steel ReinforcementReinforcement shall consist ofwire conforming to Specification A82/A82M or SpecificationA496/A496M; or of wire reinforcement conforming to Speci-fication A185/A185M or Specification A497/A497M;orofbars co

46、nforming to Specification A36/A36M, SpecificationA615/A615M Grade 40 or 60, or Specification A706/A706MGrade 60.6.6 Synthetic FibersCollated fibrillated virgin polypropy-lene fibers may be used, at the manufacturers option, inconcrete pipe as a nonstructural manufacturing material. OnlyType III synt

47、hetic fibers designed and manufactured specifi-cally for use in concrete and conforming to the requirements ofSpecification C1116 shall be accepted.7. Design7.1 Size and ShapeThe standard sizes of elliptical pipeshall be as listed in Table 1 and Table 2. The internal shape foreach size pipe shall be

48、 defined by the internal dimensionsshown in Fig. 5, subject to the permissible variations of 12.1.7.2 Design TablesThe wall thickness, compressivestrength of concrete, and the area of circumferential reinforce-ment shall be as prescribed in Table 1 and Table 2, subject tothe provisions of 7.3 and Se

49、ctions 11 and 12.7.2.1 Footnotes to the tables herein are intended to beamplifications of the tabulated requirements and are to beconsidered applicable and binding as if they were contained inthe body of the specification.NOTE 1The total reinforcement area (Asi) of the inner cage plus thequadrant mat in Quadrants 1 and 2 shall not be less than that specified forthe inner cage in Table 1.NOTE 2The total reinforcement area (Aso) of the outer cage plus thequadrant mat in Quadrants 3 and 4 shall not be less tha