ASTM C92-1995(2015) Standard Test Methods for Sieve Analysis and Water Content of Refractory Materials《耐火材料筛析和含水量的标准试验方法》.pdf

上传人:explodesoak291 文档编号:508798 上传时间:2018-12-01 格式:PDF 页数:4 大小:75.58KB
下载 相关 举报
ASTM C92-1995(2015) Standard Test Methods for Sieve Analysis and Water Content of Refractory Materials《耐火材料筛析和含水量的标准试验方法》.pdf_第1页
第1页 / 共4页
ASTM C92-1995(2015) Standard Test Methods for Sieve Analysis and Water Content of Refractory Materials《耐火材料筛析和含水量的标准试验方法》.pdf_第2页
第2页 / 共4页
ASTM C92-1995(2015) Standard Test Methods for Sieve Analysis and Water Content of Refractory Materials《耐火材料筛析和含水量的标准试验方法》.pdf_第3页
第3页 / 共4页
ASTM C92-1995(2015) Standard Test Methods for Sieve Analysis and Water Content of Refractory Materials《耐火材料筛析和含水量的标准试验方法》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: C92 95 (Reapproved 2015)Standard Test Methods forSieve Analysis and Water Content of Refractory Materials1This standard is issued under the fixed designation C92; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the yea

2、r of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 These test methods cover a wet

3、and a dry method forsieve analysis of refractory materials.1.1.1 Wet Sieve AnalysisWater promotes the slaking ofclays and helps to separate fine particles, washing them fromthe larger grains. This method is recommended for use withmaterials that require water addition, and that slake in normalindust

4、rial use.1.1.2 Dry Sieve AnalysisThe dry method is not as effec-tive as the wet method in determining the amount of materialpresent in the smaller particle sizes. It is recommended (1) forclays, when the slaking action of water is undesirable, (2) whenthe material is in the form of coarsely ground g

5、rog and calcine,and (3) when the clay is to be used in such a way that theultimate particle size is of secondary importance.1.2 These test methods also cover determination of thewater content of refractory materials in the wet condition andof air-dried samples as received, so that the sieve analysis

6、 canbe calculated on the dry basis. Included is a method forobtaining the water content of other refractory materials, suchas plastic refractories and wet mixes.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI

7、units that are provided for information onlyand are not considered standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determi

8、ne the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C429 Test Method for Sieve Analysis of Raw Materials forGlass ManufactureE11 Specification for Woven Wire Test Sieve Cloth and TestSievesE105 Practice for Probability Sampling of MaterialsE122 Pra

9、ctice for Calculating Sample Size to Estimate, WithSpecified Precision, the Average for a Characteristic of aLot or Process2.2 Other Document:ASTM STP 447 Manual on Test Sieving Methods33. Significance and Use3.1 Particle size distribution has a major affect upon most ofthe refractory properties. Th

10、ese test methods provide a meansof measuring the distribution for the purpose of comparison tothe desired distribution.3.2 These test methods also cover determination of thewater content of refractory materials in the wet condition andof air-dried samples received, so that the sieve analysis can bec

11、alculated on the dry basis.3.3 These methods can produce data for specificationacceptance, design purposes, manufacturing control, and re-search and development.3.4 Areference set of standard matched or calibrated sieves4shall be provided for use in checking the set of sieves used in1These test meth

12、ods are under the jurisdiction of ASTM Committee C08 onRefractories and are the direct responsibility of Subcommittee C08.03 on PhysicalProperties.Current edition approved March 1, 2015. Published April 2015. Originallyapproved in 1943. Last previous edition approved in 2010 as C92 95 (2010). DOI:10

13、.1520/C0092-95R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from ASTM International, 100 Bar

14、r Harbor Drive, WestConshohocken, PA 19428.4The sole source of supply of matched sieves known to the committee at thistime is W. S. Tyler, Inc., Mentor, OH 44060. If you are aware of alternativesuppliers, please provide this information to ASTM International Headquarters.Your comments will receive c

15、areful consideration at a meeting of the responsibletechnical committee,1which you may attend.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1the actual sieve analysis of samples. The sieves for use in sieveanalysis may also be standa

16、rd matched sieves or may beunmatched sieves conforming to the Specification Table inSpecification E11, provided that such sieves will give resultsthat differ by no more than 5 % from those obtained with thereference set when the two sets are compared in accordancewith the section of Test Method C429

17、 on testing of sieves andsamples splitters.4. Apparatus4.1 ASTM sieves, or the equivalent Tyler Series listed inTable 1, shall be used. The wire cloth for the sieves, describedin Specification E11, shall be woven (not twilled) and mountedwithout distortion or looseness in 8-in. (200-mm) diametercirc

18、ular frames. Pans and covers shall be provided for thesieves.5. Sampling, Test Specimens, and Test Units5.1 Arepresentative sample of the material to be tested shallweigh at least four to five times the required weight of theactual test specimen. Material on which the water content is tobe determine

19、d shall be packed in a watertight container.5.2 Water Content:5.2.1 Wet-Type Air-Setting Refractory MortarsRemoveapproximately 50 g of the material immediately after openingthe original container and after carefully mixing the contents.To facilitate handling the specimen, place it on a tared piece o

20、fwaxed paper or aluminum weighing dish. Weigh the testspecimen to the nearest 0.1 g both before and after drying for24 h at 220 to 230F (105 to 110C). Calculate the percentageof water to the nearest 0.1 % on the as-received basis.5.2.2 Materials Other Than Wet-Type Air-Setting RefractoryMortars (gro

21、und fire clays, fireclay mortars, dry-type air-setting mortars, plastic refractories, and similar materials)Ifthe material is shipped in the wet condition, prevent loss ofwater before obtaining a test specimen of approximately 250 g.Weigh the test specimen to the nearest 0.1 g both before andafter d

22、rying for3hat220to230F (105 to 110C). Calculatethe percentage of water to the nearest 0.1 % on the as-receivedbasis. The dried specimen may be required for further tests (seeSections 6 and 7).WET SIEVE ANALYSIS6. Dry Materials6.1 If the material is received in the dry condition, the testspecimen (No

23、te 1) shall consist of the dried and weighed testspecimen prepared in accordance with 5.2.2.NOTE 1The size of the test specimen may be changed by reason of thenature of the material. For example, some clays tend to pack or cake onthe sieves when ground to exceedingly fine particle size, in which cas

24、e a100-g sample may be used. For plastic refractories or coarsely groundmixes, the weight of the specimen could be increased to 500 g.7. Wet Materials7.1 Materials prepared with water (plastic refractories, wet-type high-temperature bonding mortars, etc.) shall be tested asreceived. Take two test sp

25、ecimens immediately after openingthe original container and, in the case of mortars, after carefullymixing the contents. Use one specimen for determining thewater content in accordance with either 5.2.1 or 5.2.2. Obtainapproximately 250 g of the other specimen (Note 1) for sieveanalysis. Weigh the t

26、est specimen to the nearest 0.1 g andtransfer to the 1-dm3container (see Section 8). Wash theutensils used during weighing (to which a small part of thesample may adhere) with a small jet of water from a14-in.(6-mm) hose to ensure a quantitative transfer of the weighedspecimen to the container.8. Pr

27、ocedure8.1 Place the test specimen into a container of about 1-dm3capacity.Add sufficient water to form a slurry.Allow slaking toproceed for 1 h, after which a further addition of water may benecessary. Then transfer the test specimen (without loss) to thefinest sieve to be used in the analysis. Was

28、h with a small jet ofwater from a14-in. (6-mm) rubber hose until the water passingthrough the sieve contains only traces of the specimen.Exercise care during washing to prevent loss by splashing. Itmay be necessary to break up lumps by gently rubbing betweenthe fingers, but never by rubbing or press

29、ing against the sieve.Then dry the washed residue in the sieve to constant weight at220 to 230F (105 to 110C). This usually requires about 2 h.If desired, a preliminary drying period at a lower temperaturemay be used. Then transfer the dried residue to the top orcoarsest sieve of the series to be us

30、ed. Complete the sievingand weighing operations in accordance with Section 10 or 11.9. Calculation and Report9.1 Calculate the wet sieve analysis for the test specimen onthe dry weight, and report the results to the nearest 0.1 % of thematerial retained on each sieve (Note 2). Report the percentagep

31、assing the finest sieve as the difference between 100 % andthe sum of the percentages retained on the other sieves.NOTE 2As an alternative, the results of sieve analysis may be reportedon the cumulative basis, either as the total percentage retained on orpassing each sieve.DRY SIEVE ANALYSIS10. Mech

32、anical Sieving10.1 When the sieving is to be done mechanically, arrangethe sieves in the order of size with the coarsest sieve at the topTABLE 1 ASTM Sieves and the Equivalent Tyler Standard SeriesTyler Standard Series(Mesh Designation)Sieve Opening0.265 in. 3 6.7 mm4 4 4.75 mm6 6 3.35 mm8 8 2.36 mm

33、12 10 1.70 mm16 14 1.18 mm20 20 850 m30 28 600 m40 35 425 m50 48 300 m70 65 212 m100 100 150 m140 150 106 m200 200 75 mC92 95 (2015)2of the series. The specimen for sieving (Note 1) shall consist ofa dried and weighed material prepared in accordance with5.2.2. Transfer the specimen to the top sieve

34、of the series, andmechanically sieve until less than 0.1 g passes through eachsieve after hand sieving for 1 min, as described in Section 11.The machine-sieving operation usually requires about 15 min.Then carefully separate the sieves and determine the amount ofmaterial retained on each by weighing

35、 to the nearest 0.1 g.11. Hand Sieving11.1 The specimen for sieving (Note 1) shall consist of adried and weighed material prepared in accordance with 5.2.2.Use one sieve at a time beginning with the coarsest and thensuccessively to finer sizes. Alternately tap and rotate the sieve,with pan and cover

36、 attached, while holding it in a slightlyinclined position so that the test sample will be well distributedover the sieve. Continue the operation until less than 0.1 g ofthe material passes through each sieve during 1 min ofcontinuous sieving. Determine the amount of material retainedon each sieve b

37、y weighing to the nearest 0.1 g.12. Calculation and Report12.1 Calculate the dry sieve analysis for the test specimenon the dry weight, and report the results to the nearest 0.1 % ofthe material retained on each sieve (Note 2). Include dust losswith the material passing the finest sieve.13. Precisio

38、n and Bias13.1 Interlaboratory TestingAn interlaboratory study wasconducted among seven laboratories in 1986. The samesamples of 2.5, +28 mesh tabular alumina and 14 meshsilicon carbide were tested by each laboratory to eliminatesampling variability. A third material, wet bauxite mortar, wassplit in

39、to separate samples for each laboratory for wet sieveanalysis and moisture content tests.13.1.1 The sponsoring laboratory used matched sieves andran the initial and final dry sieve analyses on the tabularalumina and the silicon carbide samples in order to evaluatesample loss or sample breakdown in t

40、he repeated runs. Thetotal specimen loss at this end of the study was 3.7 % of thetabular alumina and 4.3 % of the silicon carbide. Each of theother 6 laboratories, with one exception, ran two repetitions oneach specimen. Thus, a total of seven sets of data with tworeplicates each and one set of dat

41、a with one replicate wereanalyzed.13.1.2 The wet mortar results consisted of one set of datafrom each of six laboratories. Each set of data included sieveanalyses and water content on two separate samples split fromthe main sample received by each laboratory.13.1.3 Analysis of the sieve analyses dat

42、a was based on thepositive accumulated difference (PAD), which is the sum of theabsolute values of the difference between the percent held oneach sieve in one repetition and the grand average of thepercent on each sieve for all repetitions. The PAD divided bythe total number of sieves within the par

43、ticle size range of theparticular material gave the average PAD per sieve. Hereafter,the value will be referred to as the average difference.13.1.4 As shown in Table 2 and Table 3, the standarddeviations within and between laboratories for the averagedifference was similar for the dry tabular alumin

44、a and siliconcarbide. The standard deviations of the average difference wereslightly greater for the dry-sieved portion (+150 mesh) andmuch greater for the wet-sieved portion (150 mesh) of the wetmortar.13.2 Precision:13.2.1 Precision is based on the average difference only. Fordry sieve analyses in

45、 one laboratory, the average difference fortwo materials is significantly different at a probability of 95 %(t = 1.96) if it exceeds the repeatability (Ir) listed for precisionin Table 2 or for relative precision (% Ir)inTable 3. That is, theaverage difference between two sieve analysis on the samem

46、aterial obtained in the same laboratory will be expected toexceed the Irvalue only about 5 % of the time. If the averagedifference exceeds Ir, there is reason to question the test results.Likewise, the average difference for two materials obtained bytwo laboratories is considered to be significantly

47、 different if itexceeds the applicable reproducibility intervals (IR and % IR)in Table 2 and Table 3.13.2.2 The precision of the sieve analysis of wet materials istreated in two parts, the dry-sieved +150 mesh and thewet-sieved 150 mesh. For dry sieve analyses in onelaboratory, the average differenc

48、e for two materials is signifi-cantly different at a probability of 95 % (t = 1.96) if it exceedsthe repeatability intervals listed for precision in Table 2 or forrelative precision in Table 3. Likewise for comparing theaverage differences of two wet materials tested in two labora-tories.13.2.3 The

49、precision and relative precision for the watercontent of wet materials are shown in Table 2 and Table 3,respectively, and are used in the same fashion as described in13.2.2.TABLE 2 PrecisionMaterialAverageDifferencefrom GrandAverage XStandard Devia-tion Within-BetweenRepeatability-ReproducibilityIntervalsSr SL Ir IRTabular alumina(2.5 28 m)0.74 0.064 0.293 0.18 0.85SiC (14 m)Grand average0.700.720.0590.0620.3060.3000.170.1750.880.865Wet mortar 0.35 0.123 0.0221 0.35 0.35(28 150 m)(150 m) 1.25 0.860 0.700 2.40 3.10AverageWater content 12.4 0.11 1.15 0

展开阅读全文