ASTM C926-2015be1 Standard Specification for Application of Portland Cement-Based Plaster《硅酸盐水泥基灰浆应用的标准规格》.pdf

上传人:周芸 文档编号:508840 上传时间:2018-12-01 格式:PDF 页数:14 大小:365.50KB
下载 相关 举报
ASTM C926-2015be1 Standard Specification for Application of Portland Cement-Based Plaster《硅酸盐水泥基灰浆应用的标准规格》.pdf_第1页
第1页 / 共14页
ASTM C926-2015be1 Standard Specification for Application of Portland Cement-Based Plaster《硅酸盐水泥基灰浆应用的标准规格》.pdf_第2页
第2页 / 共14页
ASTM C926-2015be1 Standard Specification for Application of Portland Cement-Based Plaster《硅酸盐水泥基灰浆应用的标准规格》.pdf_第3页
第3页 / 共14页
ASTM C926-2015be1 Standard Specification for Application of Portland Cement-Based Plaster《硅酸盐水泥基灰浆应用的标准规格》.pdf_第4页
第4页 / 共14页
ASTM C926-2015be1 Standard Specification for Application of Portland Cement-Based Plaster《硅酸盐水泥基灰浆应用的标准规格》.pdf_第5页
第5页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: C926 15b1Standard Specification forApplication of Portland Cement-Based Plaster1This standard is issued under the fixed designation C926; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A num

2、ber in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEA2.6.1, A2.6.4, and A2.6.5.1 were revised editorially to remove unnecessary capitalization in Dec. 2015.1. Scope*1.1 This specification covers th

3、e requirements for the appli-cation of full thickness portland cement-based plaster forexterior (stucco) and interior work.1.2 This specification sets forth tables for proportioning ofvarious plaster mixes and plaster thickness.NOTE 1General information will be found in Annex A1. Designconsideration

4、s will be found in Annex A2.1.3 The values stated in inch-pound units are to be regardedas the standard. The SI (metric) values given in parentheses areapproximate and are provided for information purposes only.1.4 The text of this specification references notes andfootnotes that provide explanatory

5、 material. These notes andfootnotes (excluding those in tables and figures) shall not beconsidered as requirements of the specification.1.5 Details of construction for a specific assembly toachieve the required fire resistance shall be obtained fromreports of fire-resistance tests, engineering evalu

6、ations, orlistings from recognized fire testing laboratories.2. Referenced Documents2.1 ASTM Standards:2C11 Terminology Relating to Gypsum and Related BuildingMaterials and SystemsC25 Test Methods for Chemical Analysis of Limestone,Quicklime, and Hydrated LimeC35 Specification for Inorganic Aggregat

7、es for Use in Gyp-sum PlasterC91 Specification for Masonry CementC150 Specification for Portland CementC206 Specification for Finishing Hydrated LimeC207 Specification for Hydrated Lime for Masonry Pur-posesC219 Terminology Relating to Hydraulic CementC260 Specification for Air-Entraining Admixtures

8、 for Con-creteC578 Specification for Rigid, Cellular Polystyrene ThermalInsulationC595 Specification for Blended Hydraulic CementsC631 Specification for Bonding Compounds for InteriorGypsum PlasteringC897 Specification for Aggregate for Job-Mixed PortlandCement-Based PlastersC932 Specification for S

9、urface-Applied Bonding Com-pounds for Exterior PlasteringC1063 Specification for Installation of Lathing and Furringto Receive Interior and Exterior Portland Cement-BasedPlasterC1116 Specification for Fiber-Reinforced Concrete andShotcreteC1328 Specification for Plastic (Stucco) CementE90 Test Metho

10、d for Laboratory Measurement of AirborneSound Transmission Loss of Building Partitions andElementsE119 Test Methods for Fire Tests of Building Constructionand MaterialsE492 Test Method for Laboratory Measurement of ImpactSound Transmission Through Floor-Ceiling AssembliesUsing the Tapping Machine2.2

11、 ANSI Standard:A108.1 Specification for Installation of Ceramic Tile33. Terminology3.1 Terms shall be defined as in Terminologies C11 andC219, except as modified herein.3.2 Definitions of Terms Specific to This Standard:3.2.1 accelerator, nan admixture that will shorten thesetting time of plaster.1T

12、his specification is under the jurisdiction of ASTM Committee C11 onGypsum and Related Building Materials and Systems and is the direct responsibilityof Subcommittee C11.03 on Specifications for theApplication of Gypsum and OtherProducts in Assemblies.Current edition approved July 15, 2015. Publishe

13、d December 2015. Originallyapproved in 1981. Last previous edition approved in 2015 as C926 15a. DOI:10.1520/C0926-15BE01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, ref

14、er to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, W

15、est Conshohocken, PA 19428-2959. United States13.2.2 admixture, na material other than water, aggregate,or basic cementitious material added to the batch before orduring job mixing.3.2.3 acid etching, nthe cleansing and controlled erosionof a solid surface, using an acid wash.3.2.4 air entrainment,

16、nthe use of an air-entraining ad-mixture or air-entraining cementitious material in a plaster mixto yield a controlled quantity of minute (typically between 10and 1000 m in diameter) disconnected air bubbles in theplaster (see entrapped air).3.2.5 back wrap, na means of terminating a polymer-modifie

17、d, fabric reinforced cementitious base coat by wrappingthe reinforcing mesh, which has been affixed to the substrateonto the outboard surface of the foam plastic core to providecontinuity of the reinforced base coat and protection for thefoam plastic core.3.2.6 backplaster, nplaster applied to the f

18、ace of metallath opposite a previously applied plaster.3.2.7 barrier wall, ntype of wall system that is intended toblock or interrupt the movement of water to the interior.3.2.8 bond, nthe state of adhesion between plaster coats orbetween plaster and plaster base.3.2.9 bonding compound or agent, nco

19、mpounds surfaceapplied or integrally mixed with plaster to improve the qualityof bond between plaster and plaster base or between plastercoats.3.2.10 cementitious material, na material that, whenmixed with water and with or without aggregate, provides theplasticity and the cohesive and adhesive prop

20、erties necessaryfor placement and the formation of a rigid mass.3.2.11 coat, na thickness of plaster applied in a singleoperation.3.2.11.1 basecoat, nall plaster applied before the applica-tion of the finish coat.3.2.11.2 bedding coat, na plaster coat that receives aggre-gate or other decorative mat

21、erial impinged into its surfacebefore it sets.3.2.11.3 brown coat, nin three-coat work, the second coat,applied over the scratch coat. In two-coat work, brown coatrefers to the double-up basecoat. In either use, the brown coatis the coat directly beneath the finish coat.3.2.11.4 dash-bond coat, na t

22、hick wet mixture of portlandcement and water, with or without aggregate, dashed onto thesurface of a plaster base such as smooth monolithic concrete orconcrete block surfaces to improve the mechanical key forsubsequent plaster coats.3.2.11.5 double-up coat, nthe brown-coat plaster appliedto the scra

23、tch coat plaster before the scratch-coat plaster hasset.3.2.11.6 finish coat, nthe final layer of plaster applied overbasecoat plaster.3.2.11.7 fog coat, na light coat of cement and water, withor without aggregate or color pigment, applied by machinespray to improve color consistency.3.2.11.8 scratc

24、h coat, nthe first coat of plaster applied toa plaster base.3.2.11.9 skim coat, na thin finish coat applied to anexisting plaster surface or other substrate to improve appear-ance.3.2.11.10 three-coat work, napplication of plaster in threesuccessive coats with time between coats for setting or dryin

25、g,or both.3.2.12 cold joint (“joining” or “jointing”), nthe junctureof fresh plaster application adjacent to set plaster, in the sameplane.3.2.13 curing, vthe act or processes of producing a mois-ture environment favorable to cement hydration, resulting inthe setting or hardening of the plaster.3.2.

26、14 drainage wall, na wall system in which the clad-ding provides a substantial barrier to water intrusion, andwhich also incorporates a concealed water-resistive barrierover which drainage will occur.3.2.15 entrapped air, nunintentional air voids in the plas-ter generally larger than 1 mm.3.2.16 fac

27、tory prepared (“mill-mixed” or “ready mixed”),adjpertaining to material combinations that have been for-mulated and dry-blended by the manufacturer, requiring onlythe addition of and mixing with water to produce plaster.3.2.17 fiber, natural or synthetic, nan elongated fiber orstrand admixture added

28、 to plaster mix to improve cohesivenessor pumpability, or both.3.2.18 floating, vact of compacting and leveling brown-coat plaster to a reasonably true surface plane using a float toolor the act of bringing the aggregate to the surface of finish-coatplaster.3.2.19 key (also mechanical key), nplaster

29、 that physicallysurrounds, penetrates, or deforms to lock onto the perforationsor irregularities of the plaster base or previous coat of plaster.3.2.20 metal plaster base, nexpanded metal lath, orwelded or woven wire lath.3.2.21 plaster, nportland cement-based cementitious mix-ture (see stucco).3.2.

30、22 polymer modified cementitious base coat, nA basecoat containing portland cement modified with chemical ad-mixtures (typically polymer latexes) to improve characteristicsof the finished product, such as workability, plasticity, waterresistance, and adhesion.3.2.23 required, adjpertaining to a mand

31、atory obligationimposed by a force outside of this specification, such as abuilding code, project specification, contract, or purchaseorder.3.2.24 rustication (also “break”), nan interruption orchange in plane of a plastered surface.3.2.25 scoring (also known as “scratching”), nthe groov-ing of the

32、surface of an unset plaster coat to provide a key fora subsequent coat.3.2.26 set, nthe chemical and physical change in plaster asit goes from a plastic, workable state to a rigid state.C926 15b123.2.27 solid plaster bases, nsubstrates that do not requirea metal plaster base, including cast in place

33、 and precastconcrete, concrete and stone masonry, clay brick, and tile.3.2.28 stucco, nportland cement-based plaster used onexterior locations.3.2.29 stucco finish, na factory-prepared, dry blend ofmaterials for finish coat applications.3.2.30 temper, vto mix or restore unset plaster with waterto a

34、workable consistency.3.2.31 texture, nany surface appearance as contrasted to asmooth surface.4. Delivery and Storage of Materials4.1 Delivery:4.1.1 Packaged materials shall be delivered in factory-sealed, unopened, and unbroken packages, containers, orbundles.4.1.2 Bulk materials shall be delivered

35、 in clean transportvessels, free of contaminates.4.2 Storage:4.2.1 Weather-sensitive materials shall be kept in a drycondition until ready for use. (See A2.4.)4.2.2 Bulk materials shall be stored to prevent subsequentcontamination and segregation.5. Materials5.1 Materials shall conform to the requir

36、ements of thereferenced specifications and standards and to the requirementsspecified herein.5.2 Cement:5.2.1 Portland CementSpecification C150, Type I, II, andIII, as specified. White where specified.5.2.2 Air-Entraining Portland CementSpecification C150,type as specified. White where specified.5.2

37、.3 Masonry CementSpecification C91, Types N, S, andM. White where specified.5.2.4 Blended Hydraulic CementSpecification C595,Type IP, IS(70), IL, and IT(S70), as specified.5.2.5 Air-Entraining Blended Hydraulic CementSpecification C595, Type IP-(A), IS(70)-(A), IL-(A), and IT(S70)-(A), as specified.

38、5.2.6 Plastic CementPlastic Cement shall meet the re-quirements of Specification C1328, Standard Specification forPlastic (Stucco) Cement.NOTE 2Plastic cements are not available nationally.5.3 Type “S” Hydrated LimeAhydrated lime that containsnot more than 8 % unhydrated oxides when tested in accor-

39、dance with Test Methods C25. See Specifications C206 andC207 for a complete description of a Type “S” hydrated lime.5.4 Aggregates:5.4.1 Sand for Base CoatsSpecification C897. Aggregatefailing to meet gradation limits in Specification C897 shall bepermitted to be used, provided the plaster made with

40、 this sandhas an acceptable demonstrated performance record in similarconstruction and climate conditions.5.4.2 PerliteSpecification C35.5.4.3 Sand for Job-Mixed Finish CoatsSpecificationC897.5.5 WaterWater used in mixing, application, and finishingof plaster shall be clean, fresh, suitable for dome

41、stic waterconsumption, and free of such amounts of mineral or organicsubstances as would affect the set, the plaster, or any metal inthe system.5.6 AdmixturesSee 3.2.2 and A2.5.5.7 FibersSpecification C1116 on alkali-resistant fibers,glass fibers, nylon, polypropylene or carbon fibers.5.8 Product Ma

42、rkingPackaged materials shall be clearlymarked or labeled to indicate product, brand name, themanufacturer, and the weight of the material contained therein.Similar information shall be provided in the shipping advicesaccompanying the shipment of bulk materials.6. Requirements for Bases to Receive P

43、ortland Cement-Based Plaster6.1 Metal bases and accessories used to receive plaster shallbe installed in conformance with Specification C1063, exceptas otherwise specified.NOTE 3All metal, or PVC, or CPVC plastic members should be freeof deleterious amounts of rust, oil, or other foreign matter, whi

44、ch couldcause bond failure or unsightly discoloration.6.2 Surfaces of solid bases to receive plaster, such asmasonry, stone, cast-in-place or precast concrete shall bestraight and true within14 in. in 10 ft (2.1 mm/m) and shall befree of form oil or other elements, which would interfere withbonding.

45、 Conditions where the surfaces are out of toleranceshall be corrected prior to the application of the plaster.Ferrous-containing form ties or other obstructions shall beremoved or receded a minimum 1/8 in. (3 mm) below thesurface of the solid base and treated with a corrosion-resistantcoating. Non-f

46、errous protuberances shall be permitted to betrimmed back even with the surface of the solid base.6.2.1 Solid surfaces shall have the suction (ability to absorbwater) or surface roughness, or both, to provide the bondrequired for the plaster.6.2.2 Smooth or nonabsorbent solid surfaces, such as cast-

47、in-place or precast concrete, shall be prepared to receiveportland cement plaster by one of the following methods:6.2.2.1 Sandblasting, wire brushing, acid etching, or chip-ping or a combination thereof,6.2.2.2 Application of a dash-bond coat applied forcefullyagainst the surface, left untroweled, u

48、ndisturbed, and moistcured for at least 24 h, or6.2.2.3 Application of a bonding compound suitable forexterior or interior exposure solid surfaces in accordance withthe manufacturers written directions.6.2.3 Where bond cannot be obtained by one or more of themethods in 6.2.2, a furred or self-furrin

49、g metal plaster baseshall be installed in accordance with Specification C1063.Where metal plaster base is used in areas where bond cannot beobtained by one or more of the methods in 6.2.2, accessoriesshall be installed in accordance with Specification C1063.C926 15b137. Plaster Proportions and Mixing7.1 Proportions:7.1.1 All portland cement plasters shall be mixed andproportioned in accordance with the following tables andaccompanying requirements, using measuring devices ofknown volume with successive batches propo