1、Designation: D5799 95 (Reapproved 2009)Standard Test Method forDetermination of Peroxides in Butadiene1This standard is issued under the fixed designation D5799; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi

2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of peroxidesin butadiene.1.2 This test method covers the concentrations range of 1 to

3、10 ppm by mass (ppmw) as available oxygen.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of t

4、he user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1265 Practice for Sampling Liquefied Petroleum (LP)Gases, Manual MethodD3700 Practice for Obtaining LPG S

5、amples Using a Float-ing Piston Cylinder3. Summary of Test Method3.1 A known mass of the butadiene sample is placed in aflask and evaporated. The residue is then refluxed with aceticacid and sodium iodide reagents. The peroxides react toliberate iodine which is titrated with standard sodium thiosul-

6、fate solution using visual end-point detection. Interfering tracesof iron are complexed with sodium fluoride.4. Significance and Use4.1 Due to the inherent danger of peroxides in butadiene,specification limits are usually set for their presence. This testmethod will provide values that can be used t

7、o determine theperoxide content of a sample of commercial butadiene.4.2 Butadiene polyperoxide is a very dangerous product ofthe reaction between butadiene and oxygen that can occur. Theperoxide has been reported to be the cause of some violentexplosions in vessels that are used to store butadiene.5

8、. Apparatus5.1 Condensers, Liebig, with 24/40 standard-taperedground-glass joint connections.5.2 Cylinders, graduated, 100-mL capacity.5.3 Flask, Erlenmeyer, 250-mL capacity, with 24/40standard-tapered ground-glass connections with marking at100 mL.5.4 Heating Mantle, electric, for 250-mL Erlenmeyer

9、 flasks.5.5 Microburette, 10-mL capacity, graduated in 0.02-mLdivisions.5.6 Water Bath, a thermostatically controlled liquid bathcapable of maintaining a water temperature of 60 6 1C.6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is

10、 intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.3Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use

11、 without lessening theaccuracy of the determination.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean deionized or distilledwater.6.3 Acetic Acid, 94 % by volume. Mix 60 mL of water with940 mL of glacial acetic acid (CH3COOH). (WarningPoisonous and corrosi

12、ve. Combustible. May be fatal if swal-lowed. Causes severe burns. Harmful if inhaled.)6.4 Carbon Dioxide, solid (dry ice). (WarningUse glovesto avoid frostbite when handling.)6.5 Potassium Dichromate Solution, Standard (0.1 N)Dissolve 2.452 g of potassium dichromate (K2Cr2O7) in water1This test meth

13、od is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.D0.04 on C4 Hydrocarbons.Current edition approved July 1, 2009. Published November 2009. Originallyapproved in 1995. Last previous edition approved in 2004 as D5

14、79995(2004).DOI: 10.1520/D5799-95R09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Reagent Chemicals, Amer

15、ican Chemical Society Specifications, AmericanChemical Society, Washington, DC. For Suggestions on the testing of reagents notlisted by the American Chemical Society, see Annual Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary

16、, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.and dilute to 500 mL in a volumetric flask.(WarningAvoidcontact with eyes and skin and avoid breathing of dust.)6.6 Sodium Flu

17、oride.6.7 Sodium Iodide.6.8 Sodium Thiosulfate Solution, Standard (0.1 N)Dissolve 12.5 g of sodium thiosulfate (Na2S2O33 5H2O) plus0.1 g of sodium carbonate (Na2CO3) in 500 mL of water (theNa2CO3is added to stabilize the Na2S2O3solution). Let thissolution stand a week or more before using. Standardi

18、zeagainst 0.1 N K2Cr2O7solution. Restandardize at frequenciesto detect changes of 0.0005 in normality.7. Sampling7.1 Butadiene should be sampled in a metal container of atype which ensures maximum safety and which is resistant tobutadiene corrosion. The size of the container is dependentupon the num

19、ber of times the test is to be performed accordingto this test method. Refer to Practice D1265 or Practice D3700for instructions on sampling.8. Procedure8.1 Remove the oxygen from a 250-mL Erlenmeyer flask byadding several pellets (approximately 1 cm in size) of dry iceand allowing the CO2to displac

20、e the air. This will takeapproximately 5 min.8.2 Record the weight to one decimal place of the samplecylinder, and then transfer approximately 100 mLs of butadi-ene sample from the cylinder to the 250 mL Erlenmeyer flaskcontaining several pellets of dry ice. Reweigh the samplecylinder and record the

21、 weight of the sample as the differenceof the two weights. (WarningButadiene is a flammable gasunder pressure.)8.3 Place the flask in a water bath at 60C in a wellventilated hood. Allow the butadiene to evaporate whilekeeping an inert atmosphere above the liquid butadiene bycontinuing to add pellets

22、 of dry ice at intervals until all thebutadiene has evaporated. (WarningPeroxides are unstableand react violently when taken to dryness. Peroxides at thelevels experienced during the test method evaluation have notcaused a problem, but caution needs to be exhibited in handlingby the use of personal

23、protective equipment.)8.4 Remove the flask from the water bath and allow to coolto ambient temperature. Add 50 mL of 94 % acetic acid and0.20 6 0.02 g of sodium fluoride. Add several more pellets ofdry ice to the flask and allow to stand for 5 min.8.5 Add 6.0 6 0.2 g of sodium iodide to the flask an

24、dimmediately connect to the Liebig condenser. Turn on theheating mantle and reflux the solution for 25 6 5 min. Keep theequipment away from strong light during refluxing.8.6 At the end of the reaction period, turn off the heatingmantle and remove the flask with condenser from the mantle.Immediately

25、add 100 mL of water through the top of thecondenser followed by several pellets of dry ice.8.7 Maintaining an inert atmosphere with CO2pellets,remove the flask from the condenser and allow to cool toambient temperature. Cold water may be used to assist in thisstep. Titrate the liberated iodine with

26、0.1 N sodium thiosulfateuntil a clear endpoint is reached.8.8 Repeat 8.4 through 8.7 for the reagent blank.9. Calculation9.1 Calculate the peroxide content as follows:peroxide, as O2, ppmw 5A 2 B! 3 N 3 16 000W(1)where:A =Na2S2O3solution required for titration of thesample, mL,B =Na2S2O3solution req

27、uired for titration of theblank, mL,N = normality of the Na2S2O3solution,W = sample weight, g, and16 000 = milliequivalents of oxygen.10. Precision and Bias410.1 PrecisionThe precision of this test method as deter-mined by statistical examination of interlaboratory results is asfollows:10.1.1 Repeat

28、abilityThe difference between two test re-sults obtained by the same operator with the same apparatusunder constant operating conditions on identical test materialswould, in the long run, in the normal and correct operation ofthe test method, exceed the following values only in one caseof twenty:R 5

29、 1.4 ppmw10.1.2 ReproducibilityThe difference between two singleand independent results, obtained by different operators work-ing in different laboratories on identical test material, would, inthe long run and in the normal and correct operation of the testmethod, exceed the following values only in

30、 one case intwenty.R 5 3.4 ppmw10.2 BiasAs no reliable source of butadiene polyperoxideis available, the actual bias of the test method is unknown; butpublished data reports that this test method determines 90 % ofthe polyperoxide.511. Keywords11.1 butadiene; butadiene polyperoxide; peroxide4Support

31、ing data have been filed at ASTM International Headquarters and maybe obtained by requesting Research Report RR: D02-1372.5For a discussion of the background for this test method, see Mayo, Hendry,Jones, and Scheatzle, Industrial and Engineering Chemical , Product Research,Vol7, 1968, p. 145.D5799 9

32、5 (2009)2ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such ri

33、ghts, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additiona

34、l standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the AST

35、M Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).D5799 95 (2009)3

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1