ASTM E84-2016 5469 Standard Test Method for Surface Burning Characteristics of Building Materials《建筑材料表面燃烧特性的标准试验方法》.pdf

上传人:arrownail386 文档编号:527671 上传时间:2018-12-04 格式:PDF 页数:22 大小:694.92KB
下载 相关 举报
ASTM E84-2016 5469 Standard Test Method for Surface Burning Characteristics of Building Materials《建筑材料表面燃烧特性的标准试验方法》.pdf_第1页
第1页 / 共22页
ASTM E84-2016 5469 Standard Test Method for Surface Burning Characteristics of Building Materials《建筑材料表面燃烧特性的标准试验方法》.pdf_第2页
第2页 / 共22页
ASTM E84-2016 5469 Standard Test Method for Surface Burning Characteristics of Building Materials《建筑材料表面燃烧特性的标准试验方法》.pdf_第3页
第3页 / 共22页
ASTM E84-2016 5469 Standard Test Method for Surface Burning Characteristics of Building Materials《建筑材料表面燃烧特性的标准试验方法》.pdf_第4页
第4页 / 共22页
ASTM E84-2016 5469 Standard Test Method for Surface Burning Characteristics of Building Materials《建筑材料表面燃烧特性的标准试验方法》.pdf_第5页
第5页 / 共22页
亲,该文档总共22页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: E84 16 An American National StandardStandard Test Method forSurface Burning Characteristics of Building Materials1This standard is issued under the fixed designation E84; the number immediately following the designation indicates the year of originaladoption or, in the case of revision,

2、 the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This fire-testresponse

3、 standard for the comparativesurface burning behavior of building materials is applicable toexposed surfaces such as walls and ceilings. The test isconducted with the specimen in the ceiling position with thesurface to be evaluated exposed face down to the ignitionsource. The material, product, or a

4、ssembly shall be capable ofbeing mounted in the test position during the test. Thus, thespecimen shall either be self-supporting by its own structuralquality, held in place by added supports along the test surface,or secured from the back side.1.2 The purpose of this test method is to determine ther

5、elative burning behavior of the material by observing theflame spread along the specimen. Flame spread and smokedeveloped index are reported. However, there is not necessarilya relationship between these two measurements.1.3 The use of supporting materials on the underside of thetest specimen has th

6、e ability to lower the flame spread indexfrom those which might be obtained if the specimen could betested without such support. These test results do not neces-sarily relate to indices obtained by testing materials withoutsuch support.1.4 Testing of materials that melt, drip, or delaminate tosuch a

7、 degree that the continuity of the flame front is destroyed,results in low flame spread indices that do not relate directly toindices obtained by testing materials that remain in place.1.5 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathem

8、aticalconversions to SI units that are provided for information onlyand are not considered standard.1.6 The text of this standard references notes and footnotesthat provide explanatory information. These notes andfootnotes, excluding those in tables and figures, shall not beconsidered as requirement

9、s of the standard.1.7 This standard is used to measure and describe theresponse of materials, products, or assemblies to heat andflame under controlled conditions, but does not by itselfincorporate all factors required for fire-hazard or fire-riskassessment of the materials, products, or assemblies

10、underactual fire conditions.1.8 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations

11、prior to use.1.9 Fire testing is inherently hazardous. Adequate safe-guards for personnel and property shall be employed inconducting these tests.2. Referenced Documents2.1 ASTM Standards:2A390 Specification for Zinc-Coated (Galvanized) SteelPoultry Fence Fabric (Hexagonal and Straight Line)C1186 Sp

12、ecification for Flat Fiber-Cement SheetsC1288 Specification for Discrete Non-Asbestos Fiber-Cement Interior Substrate SheetsD4442 Test Methods for Direct Moisture Content Measure-ment of Wood and Wood-Based MaterialsD4444 Test Method for Laboratory Standardization andCalibration of Hand-Held Moistur

13、e MetersE69 Test Method for Combustible Properties of TreatedWood by the Fire-Tube ApparatusE160 Test Method for Combustible Properties of TreatedWood by the Crib Test3E162 Test Method for Surface Flammability of MaterialsUsing a Radiant Heat Energy SourceE176 Terminology of Fire StandardsE286 Test

14、Method for Surface Flammability of BuildingMaterials Using an 8-ft (2.44-m) Tunnel Furnace (With-drawn 1991)31This test method is under the jurisdiction of ASTM Committee E05 on FireStandards and is the direct responsibility of Subcommittee E05.22 on SurfaceBurning.Current edition approved July 1, 2

15、016. Published July 2016. Originally approvedin 1950. Last previous edition approved in 2015 as E84 15b. DOI: 10.1520/E0084-16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information

16、, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken,

17、PA 19428-2959. United States1E2231 Practice for Specimen Preparation and Mounting ofPipe and Duct Insulation Materials to Assess SurfaceBurning CharacteristicsE2404 Practice for Specimen Preparation and Mounting ofTextile, Paper or Polymeric (Including Vinyl) and WoodWall or Ceiling Coverings, Facin

18、gs and Veneers, toAssessSurface Burning CharacteristicsE2573 Practice for Specimen Preparation and Mounting ofSite-Fabricated Stretch Systems to Assess Surface Burn-ing CharacteristicsE2579 Practice for Specimen Preparation and Mounting ofWood Products to Assess Surface Burning CharacteristicsE2599

19、Practice for Specimen Preparation and Mounting ofReflective Insulation, Radiant Barrier and Vinyl StretchCeiling Materials for Building Applications to AssessSurface Burning CharacteristicsE2688 Practice for Specimen Preparation and Mounting ofTapes to Assess Surface Burning CharacteristicsE2690 Pra

20、ctice for Specimen Preparation and Mounting ofCaulks and Sealants to Assess Surface Burning Charac-teristicsE2768 Test Method for Extended Duration Surface BurningCharacteristics of Building Materials (30 min Tunnel Test)E2988 Practice for Specimen Preparation and Mounting ofFlexible Fibrous Glass I

21、nsulation for Metal Buildings toAssess Surface Burning Characteristics2.2 NFPA Standards:4NFPA 262 Standard Method of Test for Flame Travel andSmoke of Wires and Cables for Use in Air-HandlingSpaces (2007)2.3 UL Standards5UL 1820 Standard for Safety for Fire Test of PneumaticTubing for Flame and Smo

22、ke Characteristics (2004)UL 1887 Standard for Fire Test of Plastic Sprinkler Pipe forVisible Flame and Smoke Characteristics (2004)UL 2024 Standard for Safety for Optical Fiber and Commu-nication Cable Raceway (2004)3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this test metho

23、d referto Terminology E176. The term flame spread index fromTerminology E176 is of particular interest to this standard andis defined in 3.1.2.3.1.2 flame spread index, na number or classificationindicating a comparative measure derived from observationsmade during the progress of the boundary of a

24、zone of flameunder defined test conditions.3.2 Definitions of Terms Specific to This Standard:3.2.1 smoke developed index, na number or classificationindicating a comparative measure derived from smoke obscu-ration data collected during the test for surface burningcharacteristics.3.2.2 surface flame

25、 spread, nthe propagation of a flameaway from the source of ignition across the surface of thespecimen.4. Significance and Use4.1 This test method is intended to provide only compara-tive measurements of surface flame spread and smoke densitymeasurements with that of select grade red oak and fiber-c

26、ement board surfaces under the specific fire exposure condi-tions described herein.4.2 This test method exposes a nominal 24-ft (7.32-m) longby 20-in. (508-mm) wide specimen to a controlled air flow andflaming fire exposure adjusted to spread the flame along theentire length of the select grade red

27、oak specimen in 512 min.4.3 This test method does not provide for the following:4.3.1 Measurement of heat transmission through the testedsurface.4.3.2 The effect of aggravated flame spread behavior of anassembly resulting from the proximity of combustible wallsand ceilings.4.3.3 Classifying or defin

28、ing a material as noncombustible,by means of a flame spread index by itself.5. Apparatus5.1 Fire Test ChamberSee Figs. 1-5.5.1.1 The fire test chamber is a rectangular horizontal ductwith a removable lid. The inside dimensions are as follows:Width: 1734 14 in. (451 6.3 mm) measured between the tople

29、dges along the side walls, and 1758 38 in.(44810mm) at all other points.Depth: 12 12 in. (305 13 mm) measured from the bottom of thetest chamber to the top of the ledges on which thespecimen is supported. This measurement includes the18in. (3.2 mm) thickness of the 112 in. (38 mm) wide wovenfibergla

30、ss gasket tape.Length: 25 ft 3 in. (7.62m76mm).5.1.2 The sides and base of the chamber shall be lined withan insulating firebrick with the dimensions of 412 in. by 9 in.by 212 in. thick as illustrated in Fig. 2. The insulating firebrickshall have the following properties:Maximum Recommended Temperat

31、ure 2600F (1427C)Bulk Density 483lb/ft3(0.77 0.046 g/cm3)Thermal Conductivity at MeanTemperature ofBtuin./hft2F W/mC500F (260C) 1.6 0.231000F (538C) 1.9 0.271500F (815C) 2.2 0.322000F (1093C) 2.6 0.375.1.3 One side of the chamber shall be provided with doubleobservation windows6with the inside pane

32、flush mounted (seeFig. 2). Exposed inside glass shall be 234 638 by11+1,2in. (70 6 10 by 279 + 25 50 mm). The centerline of theexposed area of the inside glass shall be in the upper half of thefurnace wall, with the upper edge not less than 2.5 in. (63 mm)below the furnace ledge. The window shall be

33、 located such thatnot less than 12 in. (305 mm) of the specimen width can beobserved. Multiple windows shall be located along the tunnel4Available from National Fire Protection Association, 1 Battery March Park,Quincy, MA 02169.5Available from Underwriters Laboratories, 333 Pfingsten Road, Northbroo

34、k, IL60062.6Heat-resistant glass, high-silica, 100 % silica glass, nominal14-in. thick hasbeen found suitable for the interior pane. Borosilicate glass, nominal14-in. thick hasbeen found suitable for the exterior pane.E84162so that the entire length of the test sample is observable fromoutside the f

35、ire chamber. The windows shall be pressure tightin accordance with 7.2 and 7.2.1.5.1.4 The ledges shall be fabricated of structural materials7capable of withstanding the abuse of continuous testing. Theledges shall be level with respect to the length and width of thechamber and each other. The ledge

36、s shall be maintained in astate of repair commensurate with the frequency, volume, andseverity of testing occurring at any time.5.1.5 Lid:5.1.5.1 The lid shall consist of a removable noncombustiblemetal and mineral composite structure as shown in Fig. 2 andof a size necessary to cover completely the

37、 fire test chamberand the test samples. The lid shall be maintained in anunwarped and flat condition. When in place, the lid shall becompletely sealed to prevent air leakage into the fire testchamber during the test.5.1.5.2 The lid shall be insulated with a minimal thicknessof 2 in. (51 mm) castable

38、 insulation or mineral compositematerial having physical characteristics comparable to thefollowing:Maximum effective use temperature ofat least: 1200F (650C)Bulk density 21 lb/ft3(336 kg m3)Thermal conductivity at 300 to 700F(149 to 371C)0.50 to 0.71 Btuin./hft2F (0.072 to0.102 W/mK)5.1.5.3 The ent

39、ire lid assembly shall be protected with flatsections of nominal14-in. (6.3-mm) fiber-cement board meet-ing the properties of Annex A3. This protective board shall bemaintained in sound condition through continued replacement.The protective board is to be secured to the furnace lid or placeon the ba

40、ck side of the test specimen.5.1.6 Gas Burners:5.1.6.1 One end of the test chamber shall be designated asthe “fire end”. This fire end shall be provided with two gasburners delivering flames upward against the surface of the testsample (see Fig. 2). The burners shall be spaced 12 in. (305mm) from th

41、e fire end of the test chamber, and 712 612 in.(190 6 13 mm) below the under surface of the test sample. Gasto the burners shall be provided through a single inlet pipe,distributed to each port burner through a tee-section. The outletshall be a34 in. NPT elbow. The plane of the port shall beparallel

42、 to the furnace floor, such that the gas is directedupward toward the specimen. Each port shall be positionedwith its centerline 4 612 in. (102 6 13 mm) on each side ofthe centerline of the furnace so that the flame is distributedevenly over the width of the exposed specimen surface (seeFig. 2).5.1.

43、6.2 The controls used to assure constant flow of gas tothe burners during period of use shall consist of a pressureregulator, a gas meter constructed to read in increments of notmore than 0.1 ft3(2.8 L), a manometer to indicate gas pressurein inches of water, a quick-acting gas shut-off valve, and a

44、 gasmetering valve.5.1.7 Air Intake:5.1.7.1 An air intake shutter shall be located 54 6 5 in.(1372 6 127 mm) upstream of the burner, as measured fromthe burner centerline to the outside surface of the shutter (seeFig. 1). The air intake is to be fitted with a vertically slidingshutter extending the

45、entire width of the test chamber. The7High-temperature furnace refractory. Zirconium silicate, or water-cooled steeltubing have been found suitable for this purpose.FIG. 1 Test Furnace, Showing Some Critical Dimensions (Not a Construction Drawing)E84163shutter shall be positioned so as to provide an

46、 air inlet port 3 6116 in. (76 6 2 mm) high measured from the floor level of thetest chamber at the air intake point.5.1.7.2 To provide air turbulance for proper combustion,turbulance baffling shall be provided by positioning six refrac-tory firebricks (as defined in 5.1.2) along the side walls of t

47、hechamber. With the long dimension vertical, 412 in. (114-mm)dimension along the wall, place the bricks as follows from thecenterline of the burner ports:On the window side at 7, 12, and 20 12 ft (2.1, 3.7, and 6.1 0.2 m)On the opposite side at 412,912, and 16 12 ft (1.3, 2.9, and 4.9 0.2 m)5.1.7.3

48、The movement of air shall be by an induced draftsystem having a total draft capacity of at least 0.15 in. (3.8mm) water column with the sample in place, the shutter at thefire end open the normal 3 6116 in. (76 6 2 mm), and thedamper in the wide open position. A draft gage tap to indicatestatic pres

49、sure shall be inserted through the top at the midwidthof the tunnel, 1 6 0.5 in. (25 6 12 mm) below the ceiling, 156 0.5 in. (381 6 12 mm) downstream from the inlet shutter(see Fig. 1).5.1.8 Exhaust End:5.1.8.1 The other end of the test chamber is designated asthe exhaust end. The exhaust end shall be fitted with a gradualrectangular-to-round transition piece, not less than 20 in. (508mm) in length, with a cross-sectional area of not less than 200in.2(1290 cm2) at any point (see Fig. 3).5.1.8.2 The trans